100 results (0,15116 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Apollo 29600-799 Talentum Test Torch

Apollo SA7800-870APO Touch Screen Portable Test Set Unit

Apollo SA7800-870APO Touch Screen Portable Test Set Unit

Apollo SA7800-870APO Touch Screen Portable Test Set UnitThe Apollo Test Set is a portable test unit featuring a touch screen display capable of providing several functions in interrogating and controlling all devices connected to the unit either individual devices or compete circuits of analogue addressable devices in the Apollo ranges CoreProtocol Discovery and XP95.How does the product workThe standard view allows devices to be scanned and controlled through the manipulation of the devices output bits. Devices can also be self-tested using the test set and the different functionality modes can also be controlled. The unit may be powered from an AC mains charger unit or from its own internal batteries. The loop or individual address can be connected to the unit using loop connection ports which are located on the top of the device.What problem does this help solveThe device also has the functionality to test the diagnostics and integrity of the loop to find earth faults etc. The device offers fault finding capabilities which allows for time spent on site to be cut down during the commissioning stage of the system installation. The result of this is time reduced on site for the end user which reduces the overall costs of installing Apollo systems.Kit ContainsThe Apollo Test Set UnitA universal chargerTwo red connector cablesTwo black connector cablesTwo yellow connector cablesGreen connector cableXPERT 8 Intelligent Mounting BaseCarry strapQuick Start Guide

GBP 828.46
1

Apollo Cat O. XP95 Sounder VAD Base with Isolator 45681-705APO

GBP 72.02
1

Apollo 29600-664 Conventional Open-Area Sounder VAD Cat. W - Outdoor - Red Body Red Flash

Apollo 55000-739APO XP95 Open-Area VAD Cat. C - White Body Red Flash C-3-8

Apollo Cat O. XP95 VAD Base with Isolator 45681-709APO

Apollo Discovery Cat O. Discovery Sounder VAD Base with Isolator 45681-700APO

Apollo Discovery Cat O. Discovery Sounder VAD Base with Isolator 45681-700APO

Apollo Discovery Cat O. Discovery Sounder VAD Base with Isolator 45681-700APOThe Discovery Sounder VAD Base makes full use of the Discovery protocol. For ease of commissioning a Magnetic Wand can be used to test and adjust each sounder VAD locally.Key FeaturesEN54-23 certifiedFlash rate of 0.5HzIt is possible to set individual volume of the sounder from the panel15 pairs of tones including IMO code 1A General Emergency Alarm and IMO Code 2 All ClearBuilt in isolatorBrand InformationDiscovery is a range of high-specification analogue addressable fire detectors and alarm devices. Discovery detectors offer effective false alarm management by a combination of EN 54 approved operating modes and sophisticated algorithms. Drift compensation further reduces the likelihood of false alarms caused by a build-up of dust in the sensing chamber. In addition to the familiar smoke and heat detectors the Discovery range features two multisensor detectors. One is an opticalheat multisensor which can be used to protect against many types of fire risk. The other is a carbon monoxideheat multisensor which protects against both smouldering fires and those generating heat.OperationThe Discovery Multisensor construction is similar to that of the optical detector but uses a different lid and optical mouldings to accommodate the thermistor heat sensor. The Discovery OpticalHeat Multisensor Detector contains an optical smoke sensor and a thermistor temperature sensor whose outputs are combined to give the final analogue value. The way in which the signals from the two sensors are combined depends on the response mode selected.The five modes provide response behaviour which incorporates pure heat detection pure smoke detection and a combination of both. The multisensor is therefore useful over the widest range of applications. The signals from the optical smoke sensing element and the temperature sensor are independent and represent the smoke level and the air temperature respectively in the vicinity of the detector.The detectors micro-controller processes the two signals according to the mode selected. When the detector is operating as a multisensor the temperature signal processing extracts only rate-of-rise information for combination with the optical signal. In these modes the detector will not respond to a slow temperature increase even if the temperature reaches a high level. A large sudden change in temperature can however cause an alarm without the presence of smoke if sustained for 20 seconds.

GBP 78.12
1

Apollo RW1500-210APO Reach Open-Area Sounder VAD Cat. W White Body White-Flash W-2.5-7

Apollo RW1500-220APO Reach Open-Area Sounder VAD Cat. W Red Body White Flash W-2.5-7

Apollo Series 65 Optical Smoke Detector with Flashing LED and Magnetic Test Switch 55000-315APO

Apollo Series 65 Optical Smoke Detector with Flashing LED and Magnetic Test Switch 55000-315APO

Apollo Series 65 Optical Smoke Detector with Flashing LED and Magnetic Test Switch 55000-315APOThe Series 65 Optical Smoke Detector incorporates a pulsing LED located within the housing of the detector. The external detector moulding is identical to that of the ionisation detector and has an indicator LED which is clear in quiescent state but produces a red light in alarm.OperationThe Series 65 Optical Smoke Detector has a moulded self-extinguishing white polycarbonate case with wind resistant smoke inlets. Nickel-plated stainless-steel wiper contacts connect the detector to the base. Inside the case a printed circuit board has the optical system mounted on one side and the signal processing electronics on the other. The sensing chamber is a black moulding configured as a labyrinth which prevents penetration of ambient light. The labyrinth has a fine gauze insect-resistant cover. The chamber houses an infrared light emitting diode LED and a photo-diode which has an integral visible-light filter as extra protection against ambient light. Every three seconds the LED emits a burst of collimated light modulated at 4kHz. In clear air light from the LED does not fall directly on the diode because the LED is positioned at an obtuse angle to the diode. When smoke enters the chamber a fraction of the collimated light is scattered onto the photo-diode. If the resulting signal from the photo-diode is above a pre-set threshold the LED emits two more bursts of light this time at two-second intervals. If light is scattered onto the photo-diode by both these pulses due to the presence of smoke the detector signals an alarm state by switching the alarm latch on increasing the current drawn from the supply from about 40A to a maximum of 75mA. This fall in the impedance of the detector is recognised by the control panel as an alarm signal. The alarm current also illuminates the detector integral LED. A remote indicator connected between the L1 IN terminal and the R terminal will have a voltage equal to the supply voltage less 1 volt across it and so will illuminate. To ensure correct operation of the detector the control panel must be arranged to supply a maximum of 33 Volts dc and a minimum of 9 Volts dc in normal operation. The supply may fall to 6 Volts dc in alarm conditions if a supply current of at least 10mA is available at this voltage. To ensure effective illumination of the integral LED and any remote indicator the supply to the detector should exceed 12 Volts. To restore the detector to quiescent condition it is necessary to expel any smoke and interrupt the electrical supply to the detector for a minimum of one second.Key FeaturesResponds well to slow-burning smouldering firesWell-suited to bedrooms and escape routesUnaffected by wind or atmospheric pressureFlashing LED and magnet operated test switch option

GBP 19.98
1

Apollo Conventional Waterproof Call Point without LED - 55100-003APO

Apollo XPander Sounder Beacon and Optical Smoke Detector XPA-CB-14020-APO

Apollo XPander Sounder Beacon and Optical Smoke Detector XPA-CB-14020-APO

Apollo XPander Sounder Beacon and Optical Smoke DetectorXPA-CB-14020-APOXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. The interface communicates with the detection and alarm signalling devices by means of radio waves. The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface.The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.OperationXPander sounders can be wall or ceiling mounted and use a bi-directional monitored radio platform to communicate. They feature 32 selectable tones including the Apollo tone and a self test which causes a fault signal to be sent if the sounders fail to operate. The self-test feature is activated by a DIL Switch. Individual parts may be ordered separately.Key Featuresmodern stylingloop-powered interface operating on 868MHzwireless addresses seen by control panel as normal addressesradio base with wireless circuitry and battery compartmentchamber designed to inhibit dirt penetration and thus reduce false alarmsautomatic drift compensation with DirtAlert warningalgorithms for transient alarm rejectionFasTest reduces time taken to test detectors remote test facility3-5 years battery life

GBP 370.69
1

Apollo XPander Sounder Beacon and CS Heat Detector XPA-CB-14022-APO

Apollo XPander Sounder Beacon and CS Heat Detector XPA-CB-14022-APO

Apollo XPander Sounder Beacon and CS Heat DetectorXPA-CB-14022-APOXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves.The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface. The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.OperationXPander sounders can be wall or ceiling mounted and use a bi-directional monitored radio platform to communicate. They feature 32 selectable tones including the Apollo tone and a self test which causes a fault signal to be sent if the sounders fail to operate. The self-test feature is activated by a DIL Switch. Individual parts may be ordered separately.Key Featuresmodern stylingloop-powered interface operating on 868MHzwireless addresses seen by control panel as normal addressesradio base with wireless circuitry and battery compartmentchamber designed to inhibit dirt penetration and thus reduce false alarmsautomatic drift compensation with DirtAlert warningalgorithms for transient alarm rejectionFasTest reduces time taken to test detectorsremote test facility3-5 years battery life

GBP 372.43
1

Apollo XPander Sounder Beacon and A1R Heat Detector XPA-CB-14021-APO

Apollo XPander Sounder Beacon and A1R Heat Detector XPA-CB-14021-APO

Apollo XPander Sounder Beacon and A1R Heat DetectorXPA-CB-14021-APOXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves.The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface. The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.OperationXPander sounders can be wall or ceiling mounted and use a bi-directional monitored radio platform to communicate. They feature 32 selectable tones including the Apollo tone and a self test which causes a fault signal to be sent if the sounders fail to operate. The self-test feature is activated by a DIL Switch. Individual parts may be ordered separately.Key Featuresmodern stylingloop-powered interface operating on 868MHzwireless addresses seen by control panel as normal addressesradio base with wireless circuitry and battery compartmentchamber designed to inhibit dirt penetration and thus reduce false alarmsautomatic drift compensation with DirtAlert warningalgorithms for transient alarm rejectionFasTest reduces time taken to test detectorsremote test facility3-5 years battery life

GBP 372.43
1

Apollo Conventional Waterproof Manual Call Point without LED Yellow - 55100-004APO

Apollo Series 65 Indoor Manual Call Point without LED - 55100-001APO

Apollo XPander White Sounder with Mounting Base XPA-CB-14002-APO

Apollo XPander White Sounder with Mounting Base XPA-CB-14002-APO

Apollo XPander White Sounder with Mounting Base XPA-CB-14002-APOThe XPander Sounder and Sounder Base is wireless and designed to be used with XPander detectors and manual call points.Brand InformationXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves. The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface.The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.OperationXPander sounders can be wall or ceiling mounted and use a bi-directional monitored radio platform to communicate. They feature 32 selectable tones including the Apollo tone and a self test which causes a fault signal to be sent if the sounders fail to operate. The self-test feature is activated by a DIL Switch. Individual parts may be ordered separately.Key Featuresmodern stylingloop-powered interface operating on 868MHzwireless addresses seen by control panel as normal addressesradio base with wireless circuitry and battery compartmentchamber designed to inhibit dirt penetration and thus reduce false alarmsautomatic drift compensation with DirtAlert warningalgorithms for transient alarm rejectionFasTest reduces time taken to test detectorsremote test facility3-5 years battery life

GBP 240.92
1

Apollo Intelligent Open Area Red Sounder Sonos - 55000-001APO

Apollo Intelligent Red Open-Area Sounder Beacon - 55000-005APO

Apollo XPander Sounder Visual Indicator Clear and Optical Smoke Detector XPA-CB-14024-APO

Apollo XPander Sounder Visual Indicator Clear and Optical Smoke Detector XPA-CB-14024-APO

Apollo XPander Sounder Visual Indicator Clear and Optical Smoke Detector XPA-CB-14024-APOThe XPander Sounder and Sounder Base is wireless and designed to be used with XPander detectors and manual call points.OperationXPander sounders can be wall or ceiling mounted and use a bi-directional monitored radio platform to communicate. They feature 32 selectable tones including the Apollo tone and a self-test which causes a fault signal to be sent if the sounders fail to operate. The self-test feature is activated by a DIL Switch.Brand InformationXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves.The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface. The detectors incorporate drift compensation and report any compensation limit occurring.The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.Key FeaturesWirelessBi-directional monitored radio platformChoice of 32 selectable tonesAudible self-test availableOutput is between 92 and 106dbA at 1m dependent on tone setting

GBP 372.43
1

Apollo Series 65 BR Heat Detector with Flashing LED - 55000-126APO

Apollo Discovery Red Open-Area Voice Sounder - 58000-010APO

Apollo Discovery Red Open-Area Voice Sounder Beacon - 58000-030APO