457 results (0,13932 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Fireclass 517.001.304FC MTL5525 IS Sounder Driver

Fireclass 517.001.304FC MTL5525 IS Sounder Driver

Fireclass 517.001.304FC MTL5525 IS Sounder DriverThe MTL5525 Isolating Sounder Driver enables an intrinsically safe sounder located in the hazardous area to be controlled from the safe area.The barrier is designed as a CE marked replacement for the existing MTL3021 barrier. It has one channel and is suitable for connecting loads in Zone 0 IIC T4-T6 hazardous areas if suitably certified. It enables an onoff device in a hazardous area to be controlled by a volt-free contact or logic signal in the safe area. It can drive loads such as solenoids alarms LEDs and other low power devices that are certified as intrinsically safe or are classified as nonenergy storing simple apparatus.MTL5500 Series isolating IS interface units offer a compact and easy-to-use means for communicating safely with process measuring indicating actuating and local control equipment in hazardous areas. The range of models handle analogue and binary signals in both directions amplifying or otherwise conditioning them as required and at the same time providing certified explosion protection for equipment and wiring in all zones and all explosive atmospheres. The range has been designed for reliability. It builds on the proven success of the MTL2000 3000 4000 and 5000 Series to bring the benefits of new developments in galvanic isolation without compromising the reliability of the designs from which it has evolved. It is designed from the outset to meet all relevant European Directives. Uniform appearance and connectability of the units and a comprehensive range of accessories and enclosures make planning a pleasure for the user.Key FeaturesInput Type VoltageOutput Type VoltageSignal Conditioner Type IsolationInput Range 1.4 - 4.5 V dcOutput Range 7.8 - 24 VMounting Type DIN RailMinimum Operating Temperature -20CMaximum Operating Temperature 60CNumber of Channels 1Module Type SolenoidAlarm DriverTermination CableOperating Temperature Range -20 - 60 CSeries MTL5000

GBP 213.74
1

Fireclass 516.016.170FC ProReact EN LHD Cable - 78C - 100m Reel

Fireclass 516.016.171FC ProReact EN LHD Cable - 78C - 500m Reel

Fireclass 516.016.173FC ProReact EN LHD Cable - 88C - 500m Reel

Fireclass 516.016.172FC ProReact EN LHD Cable - 88C - 100m Reel

Fireclass 547.004.002FC DIN Rail Mounting Bracket for FC470CV

Fireclass 557.202.708FC FC410MIM Fixing Kit for FireClass 1.9A7Ah PSUs

Fireclass FC500IP3 TCPIP Board for FC500 Fire Panels

Fireclass 557.200.954FC FC1DS Fully Functional Repeater

Fireclass 557.200.954FC FC1DS Fully Functional Repeater

Fireclass 557.200.954FC FC1DS Fully Functional RepeaterThe FC700 Fireclass range of repeaters include both AC and DC powered models with the option for single or multiple zonal displays. The FC700 FC1DS Fireclass fully functional Repeater is designed for applications where full functionality is required in a compact discrete and architecturally attractive package.FC700 FircClass panels and repeaters feature an advanced TFT colour touchscreen user interface that is ergonomically engineered specifically for fire alarm control. It is designed for operation with or without gloves and provides easy-to-use intuitive and flexible user controls including keyless log-on using RFID tags coded for different access levels.Up to seven FC700 touch screen repeaters can be connected to each FC700 control panel. Each repeater gives full user control and functionality interfacing with the control panel using an Ethernet connection. The FC700 Fireclass repeaters uses a direct network connection local network WiFi wireless or VPN with a maximum distance between the panel and the network point or repeater and network point of 100 m.Key Features8.4 TFT colour touch screen multilingual user interface - architecturally attractive and fully ProgrammableErgonomic Icon Display - Simple to operate user interface eliminates operator errorsTouch sensitive status LEDs provide event summaryInformation - Instant access to detailed event informationContext sensitive help and on screen operator instructions - reduces the need for user trainingUser configurable on screen site maps - No need for additional site plansProgrammable graphic quiescent display - Opportunity for customer brandingComprehensive point management and disable functions - Gives the user full control and reduces service and maintenance effortSelectively view or print from the extensive 10000 event log using dynamic filters Effective event diagnostics to quickly resolve site investigationsKeyless log-on using RFID tags - Identifies and logs user actionsFlush mount kit available

GBP 724.86
1

Fireclass OSID-WGFC Wire Guard for OSID Imager or Emitter

Fireclass 517.001.301FC MTL7728 Zener Safety Barrier for Conventional Detection Circuits

Fireclass 517.001.301FC MTL7728 Zener Safety Barrier for Conventional Detection Circuits

Fireclass 517.001.301FC MTL7728 Zener Safety Barrier for Conventional Detection CircuitsThe MTL7728 is an intrinsically safe zone-powered Zener-diode barrier for use in conventional fire detection systems for protection within hazardous areas.Each Zone contains two stages of pulse-tested Zener or forward- connected diodes and an infallible terminating resistor. In the event of an electrical fault in the safe area the diodes limit the voltage that can reach the hazardous area and the resistor limits the current. A fuse protects the diodes and the two stages of voltage limitation ensure continued safety if either stage should fail. No active output-current limiting circuits are employed.Model MTL7728 is certified ia for all zones and IIC for all explosive atmospheres.The MTL7700 Series intrinsically safe shunt-diode safety barriers are innovative devices designed to provide exceptionally high packing densities straightforward installation and simplified connection commissioning and maintenance facilities. The MTL7700 Series include secondary replaceable fuses. These are useful where there is the possibility of faults occurring during commissioning which would otherwise blow the barriers internal safety fuses.One secondary replaceable fuse for each barrier channel is provided and is lower in value than the safety related fuse. Fuses are packaged in small mouldings which can be latched in a disconnect position to break the safe and hazardous areas during commissioning maintenance and fault finding thus avoiding the need for additional disconnect terminals.Key FeaturesRemovable colour-coded terminalsBussed power feed to other modulesRelay and solid state switch modulesDual channel variants - 6.3mm per channelProximity detector inputsCompatible terminal numbering and safety descriptionsDimensions 105 x 90 x 12.6mmNumber of Channels 1Supply Voltage 28 V dcSafety Voltage Maximum 26 V dcSafety Current Resistance 300ohmSafety Current Maximum 93mASignal Type AnalogueMinimum Operating Temperature -20CMaximum Operating Temperature 65CHazardous Area Certification ATEXOperating Temperature Range Maximum of 65 C

GBP 77.08
1

Fireclass 557.200.955FC FC1D2 Display Only Repeater

Fireclass 557.200.955FC FC1D2 Display Only Repeater

Fireclass 557.200.955FC FC1D2 Display Only RepeaterThe FC700 Fireclass range of repeaters include both AC and DC powered models with the option for single or multiple zonal displays. The FC700 FC1D2 Display Only Repeater offers basic functionality and overview of the system status of the Fireclass fire detection system.FC700 Fireclass panels and repeaters feature an advanced TFT colour touchscreen user interface that is ergonomically engineered specifically for fire alarm control. It is designed for operation with or without gloves and provides easy-to-use intuitive and flexible user controls including keyless log-on using RFID tags coded for different access levels.Up to seven FC700 touch screen repeaters can be connected to each FC700 control panel. Each repeater gives full user control and functionality interfacing with the control panel using an Ethernet connection. The FC700 Fireclass repeaters uses a direct network connection local network WiFi wireless or VPN with a maximum distance between the panel and the network point or repeater and network point of 100 m.Key Features8.4 TFT colour touch screen multilingual user interface - architecturally attractive and fully ProgrammableErgonomic Icon Display - Simple to operate user interface eliminates operator errorsTouch sensitive status LEDs provide event summaryInformation - Instant access to detailed event informationContext sensitive help and on screen operator instructions - reduces the need for user trainingUser configurable on screen site maps - No need for additional site plansProgrammable graphic quiescent display - Opportunity for customer brandingComprehensive point management and disable functions - Gives the user full control and reduces service and maintenance effortSelectively view or print from the extensive 10000 event log using dynamic filters Effective event diagnostics to quickly resolve site investigationsKeyless log-on using RFID tags - Identifies and logs user actionsFlush mount kit available

GBP 672.68
1

Fireclass FC500PS PSTN Board for FC500 Fire Panels