17 results (0,12899 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Wagner AD-05-0665 Basic Device Top Sens - 3 Alarms Per Detector

Wagner AD-10-5250 Detector Module TT f. Pro Sensnet amp SILENT

Wagner AD-05-0462 Basic Device Pro Sens net 2 Alarm per Detector

Wagner AD-10-5210 Detector Module TT f. Pro Sensnet amp SILENT

Wagner AD-10-5230 Detector Module TT for ProSensnet amp Silent

Wagner AD-05-4300 Detection Unit TITANUS MICROSENS - Basic Device

Wagner AD-05-4300 Detection Unit TITANUS MICROSENS - Basic Device

Wagner AD-05-4300 Detection Unit TITANUS MICROSENS - Basic DeviceWAGNERs smallest air sampling smoke detector the TITANUSMICROSENS is designed for small to medium-sized areas up to 400 m in size. This economical air sampling smoke detector is ideal for use in hotel rooms offices and prison cells. The optional ROOMIDENT feature can localise fires within up to five rooms.The pint-sized TITANUSMICROSENSprovides a wealth of options. It can be configured to use a single primary alarm or a two-stage system pre-alarm and main alarm. Options include a bar graph displaying smoke density levelsanda parallel display connection. Thanks to PIPE.GUARD HPLS light technology and LOGICSENS this air sampling smoke detection system is both highly sensitive and secure against false alarms.Key FeaturesThe primary alarm can be set to sensitivity levels as high as 0.1 obs.m.This air sampling smoke detectors 40 to 50m-long pipe system can have up to eight air sampling points 5 with ROOMIDENT.The TITANUSMICROSENShas a wide range of options so it can be customised to any number of situations.A second detector module can be incorporated to create a dual detector dependency configuration.Special versions are available for deep-freeze facilities temperatures as low as -40 C and noise-critical areas to 23 dB A.The plug-and-play system makes the air sampling smoke detector quick and easy to install.Maintenance work can be performed without entering the protected area.

GBP 801.89
1

Wagner AD-05-4000 Detection Unit TITANUS MICROSENS - Basic Device

Wagner AD-05-4000 Detection Unit TITANUS MICROSENS - Basic Device

Wagner AD-05-4000 Detection Unit TITANUS MICROSENS - Basic DeviceWAGNERs smallest air sampling smoke detector the TITANUSMICROSENS is designed for small to medium-sized areas up to 400 m in size. This economical air sampling smoke detector is ideal for use in hotel rooms offices and prison cells. The optional ROOMIDENT feature can localise fires within up to five rooms.The pint-sized TITANUSMICROSENSprovides a wealth of options. It can be configured to use a single primary alarm or a two-stage system pre-alarm and main alarm. Options include a bar graph displaying smoke density levelsanda parallel display connection. Thanks to PIPE.GUARD HPLS light technology and LOGICSENS this air sampling smoke detection system is both highly sensitive and secure against false alarms.Key FeaturesThe primary alarm can be set to sensitivity levels as high as 0.1 obs.m.This air sampling smoke detectors 40 to 50m-long pipe system can have up to eight air sampling points 5 with ROOMIDENT.The TITANUSMICROSENShas a wide range of options so it can be customised to any number of situations.A second detector module can be incorporated to create a dual detector dependency configuration.Special versions are available for deep-freeze facilities temperatures as low as -40 C and noise-critical areas to 23 dB A.The plug-and-play system makes the air sampling smoke detector quick and easy to install.Maintenance work can be performed without entering the protected area.

GBP 1420.31
1

Wagner AD-05-4020 Detection Unit TITANUS MICROSENS - Bar Graph

Wagner AD-05-4020 Detection Unit TITANUS MICROSENS - Bar Graph

Wagner AD-05-4020 Detection Unit TITANUS MICROSENS - Bar GraphWagner AD-05-4020 Titanus MicroSens Detection Unit Bar Graph Version - DM-TM-B-10WAGNERs smallest air sampling smoke detector the TITANUSMICROSENS is designed for small to medium-sized areas up to 400 m in size. This economical air sampling smoke detector is ideal for use in hotel rooms offices and prison cells. The optional ROOMIDENT feature can localise fires within up to five rooms.The pint-sized TITANUSMICROSENSprovides a wealth of options. It can be configured to use a single primary alarm or a two-stage system pre-alarm and main alarm. Options include a bar graph displaying smoke density levelsanda parallel display connection. Thanks to PIPE.GUARD HPLS light technology and LOGICSENS this air sampling smoke detection system is both highly sensitive and secure against false alarms.Key FeaturesThe primary alarm can be set to sensitivity levels as high as 0.1 obs.m.This air sampling smoke detectors 40 to 50m-long pipe system can have up to eight air sampling points 5 with ROOMIDENT.The TITANUSMICROSENShas a wide range of options so it can be customised to any number of situations.A second detector module can be incorporated to create a dual detector dependency configuration.Special versions are available for deep-freeze facilities temperatures as low as -40 C and noise-critical areas to 23 dB A.The plug-and-play system makes the air sampling smoke detector quick and easy to install.Maintenance work can be performed without entering the protected area.

GBP 1729.51
1

Wagner AD-05-4320 Detection Unit TITANUS MICROSENS - Bar Graph

Wagner AD-05-4320 Detection Unit TITANUS MICROSENS - Bar Graph

Wagner AD-05-4320 Detection Unit TITANUS MICROSENS - Bar GraphWagner AD-05-4320 Titanus MicroSens Detection Unit Bar Graph Version - DM-TM-B-50WAGNERs smallest air sampling smoke detector the TITANUSMICROSENS is designed for small to medium-sized areas up to 400 m in size. This economical air sampling smoke detector is ideal for use in hotel rooms offices and prison cells. The optional ROOMIDENT feature can localise fires within up to five rooms.The pint-sized TITANUSMICROSENSprovides a wealth of options. It can be configured to use a single primary alarm or a two-stage system pre-alarm and main alarm. Options include a bar graph displaying smoke density levelsanda parallel display connection. Thanks to PIPE.GUARD HPLS light technology and LOGICSENS this air sampling smoke detection system is both highly sensitive and secure against false alarms.Key FeaturesThe primary alarm can be set to sensitivity levels as high as 0.1 obs.m.This air sampling smoke detectors 40 to 50m-long pipe system can have up to eight air sampling points 5 with ROOMIDENT.The TITANUSMICROSENShas a wide range of options so it can be customised to any number of situations.A second detector module can be incorporated to create a dual detector dependency configuration.Special versions are available for deep-freeze facilities temperatures as low as -40 C and noise-critical areas to 23 dB A.The plug-and-play system makes the air sampling smoke detector quick and easy to install.Maintenance work can be performed without entering the protected area.

GBP 1114.49
1

Wagner AD-05-4700 Titanus RackSens 1U - 0.50m Sensitivity

Wagner AD-05-4700 Titanus RackSens 1U - 0.50m Sensitivity

Wagner AD-05-4700 Titanus RackSens 1U - 0.50m SensitivityThe Titanus RackSens is Wagners air sampling smoke detector for monitoring 19 equipment such as server and control cabinets. The fire detection unit can also be expanded to include fire suppression using either integrated or externally attached extinguishing gas cylinders. Ten air sampling points provide cost-effective false alarm-proof monitoring of up to five server cabinets. This special fire detector is available in two different installation heights one or two U and using either NovecTM or nitrogen as its extinguishing gas.A three-stage safety concept provides a combination of early fire detection and fire suppression.The earliest possible high-sensitivity smoke detection - Minimise fire damage by getting a maximum head start.Automatic system shut down - Withdrawal of necessary support energy required to prevent fires from spreading and data backup via soft shutdown or virtual server management live migration.Optimised gas extinguishing - Targeted extinguishing at the exact source of the fire.Key FeaturesThe Titanus RackSens combines fire detection and suppression into a single unit 88.9 mm construction height 2UThanks to HPLS light source technology this air sampling smoke detector reaches sensitivity levels of 0.1 obs.m making it up to 400 times more sensitive than conventional smoke detectorsProven Logic.Sens fire pattern recognition technology provides excellent security against false alarmsA second detector module can also be incorporated into a dual detector dependency configuration each with two alarm stages providing maximum flexibility in system response behaviourMaintenance and interactive diagnostics can be performed without interrupting operationsA network interface card slot allows central monitoring remote diagnostics and remote maintenance via Ethernet SNMP

GBP 2103.90
1

Wagner AD-05-4355 Detection Unit TITANUS MICROSENS - Room Ident S1

Wagner AD-05-4355 Detection Unit TITANUS MICROSENS - Room Ident S1

Wagner AD-05-4355 Detection Unit TITANUS MICROSENS - Room Ident S1The Wagner AD-05-4355 is an Air Sampling detector which is part of their Titanus MicroSens detection range.WAGNERs smallest air sampling smoke detector the TITANUSMICROSENS is designed for small to medium-sized areas up to 400 m in size. This economical air sampling smoke detector is ideal for use in hotel rooms offices and prison cells. The optional ROOMIDENT feature can localise fires within up to five rooms.The pint-sized TITANUSMICROSENSprovides a wealth of options. It can be configured to use a single primary alarm or a two-stage system pre-alarm and main alarm. Options include a bar graph displaying smoke density levelsanda parallel display connection. Thanks to PIPE.GUARD HPLS light technology and LOGICSENS this air sampling smoke detection system is both highly sensitive and secure against false alarms.Key FeaturesThe primary alarm can be set to sensitivity levels as high as 0.1 obs.m.This air sampling smoke detectors 40 to 50m-long pipe system can have up to eight air sampling points 5 with ROOMIDENT.The TITANUSMICROSENShas a wide range of options so it can be customised to any number of situations.A second detector module can be incorporated to create a dual detector dependency configuration.Special versions are available for deep-freeze facilities temperatures as low as -40 C and noise-critical areas to 23 dB A.The plug-and-play system makes the air sampling smoke detector quick and easy to install.Maintenance work can be performed without entering the protected area.

GBP 1111.10
1

Wagner AD-05-4310 Detection Unit TITANUS MICROSENS Room Ident

Wagner AD-05-4310 Detection Unit TITANUS MICROSENS Room Ident

Wagner AD-05-4310 Detection Unit TITANUS MICROSENS Room IdentThe Wagner AD-05-4310 is an Air Sampling detector which is part of their Titanus MicroSens detection range.WAGNERs smallest air sampling smoke detector the TITANUSMICROSENS is designed for small to medium-sized areas up to 400 m in size. This economical air sampling smoke detector is ideal for use in hotel rooms offices and prison cells. The optional ROOMIDENT feature can localise fires within up to five rooms.The pint-sized TITANUSMICROSENSprovides a wealth of options. It can be configured to use a single primary alarm or a two-stage system pre-alarm and main alarm. Options include a bar graph displaying smoke density levelsanda parallel display connection. Thanks to PIPE.GUARD HPLS light technology and LOGICSENS this air sampling smoke detection system is both highly sensitive and secure against false alarms.Key FeaturesThe primary alarm can be set to sensitivity levels as high as 0.1 obs.m.This air sampling smoke detectors 40 to 50m-long pipe system can have up to eight air sampling points 5 with ROOMIDENT.The TITANUSMICROSENShas a wide range of options so it can be customised to any number of situations.A second detector module can be incorporated to create a dual detector dependency configuration.Special versions are available for deep-freeze facilities temperatures as low as -40 C and noise-critical areas to 23 dB A.The plug-and-play system makes the air sampling smoke detector quick and easy to install.Maintenance work can be performed without entering the protected area.

GBP 1111.10
1

Wagner AD-05-4010 Detection Unit TITANUS MICROSENS Room Ident

Wagner AD-05-4010 Detection Unit TITANUS MICROSENS Room Ident

Wagner AD-05-4010 Detection Unit TITANUS MICROSENS Room IdentThe Wagner AD-05-4010 is an Air Sampling detector which is part of their Titanus MicroSens detection range.WAGNERs smallest air sampling smoke detector the TITANUSMICROSENS is designed for small to medium-sized areas up to 400 m in size. This economical air sampling smoke detector is ideal for use in hotel rooms offices and prison cells. The optional ROOMIDENT feature can localise fires within up to five rooms.The pint-sized TITANUSMICROSENSprovides a wealth of options. It can be configured to use a single primary alarm or a two-stage system pre-alarm and main alarm. Options include a bar graph displaying smoke density levelsanda parallel display connection. Thanks to PIPE.GUARD HPLS light technology and LOGICSENS this air sampling smoke detection system is both highly sensitive and secure against false alarms.Key FeaturesThe primary alarm can be set to sensitivity levels as high as 0.1 obs.m.This air sampling smoke detectors 40 to 50m-long pipe system can have up to eight air sampling points 5 with ROOMIDENT.The TITANUSMICROSENShas a wide range of options so it can be customised to any number of situations.A second detector module can be incorporated to create a dual detector dependency configuration.Special versions are available for deep-freeze facilities temperatures as low as -40 C and noise-critical areas to 23 dB A.The plug-and-play system makes the air sampling smoke detector quick and easy to install.Maintenance work can be performed without entering the protected area.

GBP 1729.51
1

Wagner AD-05-1220 Basic Device - Top Sens - 3 Alarms Bargraph Per Detector

Wagner AD-05-1220 Basic Device - Top Sens - 3 Alarms Bargraph Per Detector

Wagner AD-05-1220 Basic Device - Top Sens - 3 Alarms Bargraph Per DetectorThe Titanus TopSens is an air sampling smoke detector with all the bells and whistles. It has all the features of the ProSens plus a network card slot to allow network capability via Ethernet SNMP connection. This premium product includes a bar graph to display smoke density levels in the event of fire.Thanks to a combination of highly sensitive HPLS optical technology and Logic Sens fire pattern recognition the Titanus TopSens combines maximum sensitivity and maximum security against false alarms in rooms as large as 5760 m. A second detector module can be used to create a dual detector dependency setup or to monitor a second area independently. Each detector module can be configured with up to three alarm levels. An additional connection socket makes parallel display possible.Key FeaturesThe Titanus TopSens features a graded alarm-activation concept with up to three alarms per detector module.Smoke levels can optionally be displayed on the unit as a bar graph.The pipe network can be configured with up to 1 x 100 or 2 x 72 air sampling points.An extensive range of DIN EN 54-20 certified accessories allow operators to tailor their systems to their individual needs.The systems modular design makes it a customisable and cost-effective solution.Versions for noise-critical areas 23 dB A and up or cold storage as low as -40 C are available as well.TianusPipeXpress Secure project planning and configuration is just five mouse clicks away.

GBP 2590.42
1

Wagner AD-05-4705 Titanus RackSens 1U - 0.10m Sensitivity

Wagner AD-05-4705 Titanus RackSens 1U - 0.10m Sensitivity

Wagner AD-05-4705 Titanus RackSens 1U - 0.10m SensitivityThe Titanus RackSens is Wagners air sampling smoke detector for monitoring 19 equipment such as server and control cabinets. The fire detection unit can also be expanded to include fire suppression using either integrated or externally attached extinguishing gas cylinders. Ten air sampling points provide cost-effective false alarm-proof monitoring of up to five server cabinets. This special fire detector is available in two different installation heights one or two U and using either NovecTM or nitrogen as its extinguishing gas.A three-stage safety concept provides a combination of early fire detection and fire suppression.The earliest possible high-sensitivity smoke detection - Minimise fire damage by getting a maximum head start.Automatic system shut down - Withdrawal of necessary support energy required to prevent fires from spreading and data backup via soft shutdown or virtual server management live migration.Optimised gas extinguishing - Targeted extinguishing at the exact source of the fire.Key FeaturesThe Titanus RackSens combines fire detection and suppression into a single unit 88.9 mm construction height 2UThanks to HPLS light source technology this air sampling smoke detector reaches sensitivity levels of 0.1 obs.m making it up to 400 times more sensitive than conventional smoke detectorsProven Logic.Sens fire pattern recognition technology provides excellent security against false alarmsA second detector module can also be incorporated into a dual detector dependency configuration each with two alarm stages providing maximum flexibility in system response behaviourMaintenance and interactive diagnostics can be performed without interrupting operationsA network interface card slot allows central monitoring remote diagnostics and remote maintenance via Ethernet SNMP

GBP 2806.93
1

Wagner AD-05-4710 Titanus RackSens 2U - 0.50m Sensitivity cw Integral Novec 1230 Extinguishant

Wagner AD-05-4710 Titanus RackSens 2U - 0.50m Sensitivity cw Integral Novec 1230 Extinguishant

Wagner AD-05-4710 Titanus RackSens 2U - 0.50m Sensitivity comes with Integral Novec 1230 ExtinguishantThe Titanus RackSens is Wagners air sampling smoke detector for monitoring 19 equipment such as server and control cabinets. The fire detection unit can also be expanded to include fire suppression using either integrated or externally attached extinguishing gas cylinders. Ten air sampling points provide cost-effective false alarm-proof monitoring of up to five server cabinets. This special fire detector is available in two different installation heights one or two U and using either NovecTM or nitrogen as its extinguishing gas.A three-stage safety concept provides a combination of early fire detection and fire suppression.The earliest possible high-sensitivity smoke detection - Minimise fire damage by getting a maximum head start.Automatic system shut down - Withdrawal of necessary support energy required to prevent fires from spreading and data backup via soft shutdown or virtual server management live migration.Optimised gas extinguishing - Targeted extinguishing at the exact source of the fire.Key FeaturesThe Titanus RackSens combines fire detection and suppression into a single unit 88.9 mm construction height 2UThanks to HPLS light source technology this air sampling smoke detector reaches sensitivity levels of 0.1 obs.m making it up to 400 times more sensitive than conventional smoke detectorsProven Logic.Sens fire pattern recognition technology provides excellent security against false alarmsA second detector module can also be incorporated into a dual detector dependency configuration each with two alarm stages providing maximum flexibility in system response behaviourMaintenance and interactive diagnostics can be performed without interrupting operationsA network interface card slot allows central monitoring remote diagnostics and remote maintenance via Ethernet SNMP

GBP 4501.02
1

Wagner AD-05-4715 Titanus RackSens 2U - 0.10m Sensitivity cw Integral Novec 1230 Extinguishant

Wagner AD-05-4715 Titanus RackSens 2U - 0.10m Sensitivity cw Integral Novec 1230 Extinguishant

Wagner AD-05-4715 Titanus RackSens 2U - 0.10m Sensitivity comes with Integral Novec 1230 ExtinguishantThe Titanus RackSens is Wagners air sampling smoke detector for monitoring 19 equipment such as server and control cabinets. The fire detection unit can also be expanded to include fire suppression using either integrated or externally attached extinguishing gas cylinders. Ten air sampling points provide cost-effective false alarm-proof monitoring of up to five server cabinets. This special fire detector is available in two different installation heights one or two U and using either NovecTM or nitrogen as its extinguishing gas.A three-stage safety concept provides a combination of early fire detection and fire suppression.The earliest possible high-sensitivity smoke detection - Minimise fire damage by getting a maximum head start.Automatic system shut down - Withdrawal of necessary support energy required to prevent fires from spreading and data backup via soft shutdown or virtual server management live migration.Optimised gas extinguishing - Targeted extinguishing at the exact source of the fire.Key FeaturesThe Titanus RackSens combines fire detection and suppression into a single unit 88.9 mm construction height 2UThanks to HPLS light source technology this air sampling smoke detector reaches sensitivity levels of 0.1 obs.m making it up to 400 times more sensitive than conventional smoke detectorsProven Logic.Sens fire pattern recognition technology provides excellent security against false alarmsA second detector module can also be incorporated into a dual detector dependency configuration each with two alarm stages providing maximum flexibility in system response behaviourMaintenance and interactive diagnostics can be performed without interrupting operationsA network interface card slot allows central monitoring remote diagnostics and remote maintenance via Ethernet SNMP

GBP 4645.42
1