114 results (0,13562 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Zeta VDOT-ASD-100 Single Zone Aspirating Smoke Detector

Zeta VDOT-ASD-400 Four Pipes Scanning Aspirating Smoke Detector

Protec Cirrus Pro 200 Aspiration Detector EN54-20 Approved

Protec Cirrus Pro 200 Aspiration Detector EN54-20 Approved

Protec Cirrus Pro 200 Aspiration Detector EN54-20 ApprovedCirrus Pro Series Aspirating Fire Detectors provide a solution for almost any aspirating system project from a simple single pipe detector with minimum Fire and Fault LED indications to a multiple pipe scanning detector with multifunction quarter VGA backlit LCD display. Programming for each detector is via a laptop computer or from an onboard or remotely mounted LCD display.The sensitivity range is the key feature that makes the Cirrus Pro Series Fire Detector the worlds most versatile fire detection device. For over 20 years Cloud Chamber detectors have been known as the most sensitive fire detection device able to detect at the true incipient stage of a developing fire. The New Cirrus Pro Series Detectors have a vast sensitivity range capable of being even more sensitive than previous versions. In addition the detector may now be configured to be installed in heavily contaminated environments such as polluted production and warehousing facilities.High Sensitivity Applications includeComputer Rooms Clean Rooms Control Rooms Data Centres Valve Halls Archive Storage Anechoic Chambers EDP areas.General Sensitivity Applications includeHistoric Buildings Museums Hospitals Cathedrals Theatres Art Galleries Clean Warehouses Atria Indoor Stadiums.Harsh Environment Applications includeCold Storage Facilities Specialist Production Facilities Food Industry Facilities Paper Production Facilities Transportation Terminals Flight Simulators Aircraft Hangers Prisons Inaccessible Voids Dirty Warehouses.Key FeaturesCloud Chamber Detection PrincipleUp to 200 mtrs Sampling PipeProgrammable Pre-Alarm warning condition3 Programmable Fire warning conditionsAirflow MonitoringFault Diagnostic featureImmune to dust humidity temperature changesEN54-20 ApprovedFor use with up to a total of 200mtrs of 25mm diameter sampling pipeFour sampling pipe inlet ports single sampling pipe exhaust portLED status indication of Common Fault Power Pre-alarm Fire 1 Fire 2 Fire 3 alarm conditionsInternal buzzer Silence button detector alarm Reset ButtonMay be networked with other Cirrus Pro Series aspirating detectors

GBP 3223.80
1

Fireclass 516.016.173FC ProReact EN LHD Cable - 88C - 500m Reel

Fireclass 516.016.171FC ProReact EN LHD Cable - 78C - 500m Reel

Aritech DF962 Gate Disconnect Assembly Kit For Sliding Gates

2Kg Commander Clean Agent Extinguisher SE04

Apollo Intelligent Flameproof IR3 Flame Detector 55000-021APO

Apollo Intelligent Triple IR Flame Detector 55000-020APO

Apollo Flameproof Intelligent IR2 Flame Detector 55000-295APO

Apollo Intelligent Dual IR Flame Detector 55000-280APO

Morley LT-SEN-M Monitoring Sensor

Fireclass 557.200.955FC FC1D2 Display Only Repeater

Fireclass 557.200.955FC FC1D2 Display Only Repeater

Fireclass 557.200.955FC FC1D2 Display Only RepeaterThe FC700 Fireclass range of repeaters include both AC and DC powered models with the option for single or multiple zonal displays. The FC700 FC1D2 Display Only Repeater offers basic functionality and overview of the system status of the Fireclass fire detection system.FC700 Fireclass panels and repeaters feature an advanced TFT colour touchscreen user interface that is ergonomically engineered specifically for fire alarm control. It is designed for operation with or without gloves and provides easy-to-use intuitive and flexible user controls including keyless log-on using RFID tags coded for different access levels.Up to seven FC700 touch screen repeaters can be connected to each FC700 control panel. Each repeater gives full user control and functionality interfacing with the control panel using an Ethernet connection. The FC700 Fireclass repeaters uses a direct network connection local network WiFi wireless or VPN with a maximum distance between the panel and the network point or repeater and network point of 100 m.Key Features8.4 TFT colour touch screen multilingual user interface - architecturally attractive and fully ProgrammableErgonomic Icon Display - Simple to operate user interface eliminates operator errorsTouch sensitive status LEDs provide event summaryInformation - Instant access to detailed event informationContext sensitive help and on screen operator instructions - reduces the need for user trainingUser configurable on screen site maps - No need for additional site plansProgrammable graphic quiescent display - Opportunity for customer brandingComprehensive point management and disable functions - Gives the user full control and reduces service and maintenance effortSelectively view or print from the extensive 10000 event log using dynamic filters Effective event diagnostics to quickly resolve site investigationsKeyless log-on using RFID tags - Identifies and logs user actionsFlush mount kit available

GBP 672.68
1

Patol ASD531 Single Sensor Standard Display with SSD531 Detector

Patol ASD531 Single Sensor Standard Display with SSD531 Detector

Patol ASD531 Single Sensor Standard Display with SSD531 DetectorThe ASD 531 Aspirating Smoke Detector is the new generation of a highly sensitive active smoke detection system. It is based on the successful ASD 535 and is particularly well suited for monitoring smaller areas and sampling distances where a reduced sampling pipe network is sufficient. The ASD 531 consists of a fan a highly sensitive smoke sensor an airflow measurement system and evaluation electronics. The fan draws in air through sampling holes from the room or facility being monitored and then through a sampling pipe to the evaluating processor unit.Here the air samples are continually monitored for smoke particles by the smoke sensor. Airflow monitoring ensures that the sampling pipe is constantly checked for pipe breakage and any obstruction of the sampling holes. The display and control panel of the evaluating processor unit indicates alarm fault and status reports. Any increase in the smoke concentration levels are detected very early. Three fixed pre-alarms and one main alarm which can be forwarded to a fire alarm control panel via volt free relays contacts.The ASD 531 is used whenever conventional point-type smoke detectors cannot be used. This may be due for example to ambient conditions too hot too cold too dirty or because operating conditions are such that access is highly restricted Elevator Shafts prisons false ceilings clean rooms laboratories etc.Key Features1 sampling pipe 1 detectorEN 54-20 classes A B and C4 alarm levels 1 fire alarm 3 fixed pre-alarms 30 50 70 when using RIM36 ModuleResponse sensitivity settable from 0.00610mInsensitive to dirt particles due to particle suppressionLow noise level compliant with ISO 11690-1Perfected smoke detection with HD sensor high-dynamic technologyLow power consumptionOnboard ConfigurationASD PipeFlow calculation toolIndividually Replaceable Components Sensors PCBs etc

GBP 1031.52
1

Fireclass 557.200.954FC FC1DS Fully Functional Repeater

Fireclass 557.200.954FC FC1DS Fully Functional Repeater

Fireclass 557.200.954FC FC1DS Fully Functional RepeaterThe FC700 Fireclass range of repeaters include both AC and DC powered models with the option for single or multiple zonal displays. The FC700 FC1DS Fireclass fully functional Repeater is designed for applications where full functionality is required in a compact discrete and architecturally attractive package.FC700 FircClass panels and repeaters feature an advanced TFT colour touchscreen user interface that is ergonomically engineered specifically for fire alarm control. It is designed for operation with or without gloves and provides easy-to-use intuitive and flexible user controls including keyless log-on using RFID tags coded for different access levels.Up to seven FC700 touch screen repeaters can be connected to each FC700 control panel. Each repeater gives full user control and functionality interfacing with the control panel using an Ethernet connection. The FC700 Fireclass repeaters uses a direct network connection local network WiFi wireless or VPN with a maximum distance between the panel and the network point or repeater and network point of 100 m.Key Features8.4 TFT colour touch screen multilingual user interface - architecturally attractive and fully ProgrammableErgonomic Icon Display - Simple to operate user interface eliminates operator errorsTouch sensitive status LEDs provide event summaryInformation - Instant access to detailed event informationContext sensitive help and on screen operator instructions - reduces the need for user trainingUser configurable on screen site maps - No need for additional site plansProgrammable graphic quiescent display - Opportunity for customer brandingComprehensive point management and disable functions - Gives the user full control and reduces service and maintenance effortSelectively view or print from the extensive 10000 event log using dynamic filters Effective event diagnostics to quickly resolve site investigationsKeyless log-on using RFID tags - Identifies and logs user actionsFlush mount kit available

GBP 724.86
1

Apollo Exd Conventional Triple IR Flame Detector 55000-062APO

Apollo I.S. Conventional Triple IR Flame Detector 55000-063APO

Wagner AD-05-0665 Basic Device Top Sens - 3 Alarms Per Detector

Wagner AD-10-5250 Detector Module TT f. Pro Sensnet amp SILENT

Wagner AD-05-0462 Basic Device Pro Sens net 2 Alarm per Detector

Wagner AD-10-5210 Detector Module TT f. Pro Sensnet amp SILENT

Patol ASD535-3 Single Sensor Full Display with SSD535-3 Detector

Patol ASD535-3 Single Sensor Full Display with SSD535-3 Detector

Patol ASD535-3 Single Sensor Full Display with SSD535-3 DetectorThe ASD 535 Aspirating Smoke Detector is the new generation of highly sensitive active smoke detection system. It offers application specific sensitivity adjustment alongside pre-signalling and pollution analyses. The ASD 535 detects even minuscule glowing and smouldering fires and can be deployed practically anywhere.The ASD 535 consists of one or two independent sampling lines with sampling apertures each with a highly sensitive smoke sensor. Air flow monitoring ensures that the sampling lines are constantly checked for pipe breakage and the sampling holes monitored for pollution. A high-performance ventilator draws the air from the room or facility being monitored through the sampling line to the evaluating processor unit.There the air is continuously evaluated by the smoke sensors. The display and control panel of the evaluating processor unit indicates the smoke concentration of the sampled air and other alarm fault and status messages. Any increase in the smoke concentration is detected very early. Three pre-alarms and two main alarms can be programmed for each and signalled via volt free relays contacts. There are four expansion slots for accommodating modular 1 x network card 1 x memory card and 2 relay cards.The ASD 535 is ideal for property and space surveillance thanks to its excellent response behaviour and is used whenever conventional point-type smoke detectors cannot be used. This may be due for example to ambient conditions too hot too cold too dirty or because operating conditions are such that access is highly restricted prisons false ceilings clean rooms laboratories high rack storage facilities etc.. Or because lightning-fast detection is required e.g. in data centres.Key FeaturesLatest generation of universal aspiration smoke detectors1 or 2 sampling lines with separate sensors and air flow monitoringEN54-20 classes A B and CVds certified calculation software ASD PipeFlow enables efficient asymmetrical pipe layout4 alarm levels 3 pre-alarms and 2 alarmsResolution 0.001mInsensitive to pollutants thanks to particle suppressionAuto-learning functionLow noise level compliant with ISO 11690-1Refined smoke detection thanks to HD sensor high-dynamic technologyLow power consumptionHigh performance suction 400 Pa vacuumIndividually replaceable

GBP 2424.24
1

Patol ASD535-4 Dual Sensor Full Display with SSD535-3 Detectors

Patol ASD535-4 Dual Sensor Full Display with SSD535-3 Detectors

Patol ASD535-4 Dual Sensor Full Display with SSD535-3 DetectorsThe ASD 535 Aspirating Smoke Detector is the new generation of highly sensitive active smoke detection system. It offers application specific sensitivity adjustment alongside pre-signalling and pollution analyses. The ASD 535 detects even minuscule glowing and smouldering fires and can be deployed practically anywhere.The ASD 535 consists of one or two independent sampling lines with sampling apertures each with a highly sensitive smoke sensor. Air flow monitoring ensures that the sampling lines are constantly checked for pipe breakage and the sampling holes monitored for pollution. A high-performance ventilator draws the air from the room or facility being monitored through the sampling line to the evaluating processor unit.There the air is continuously evaluated by the smoke sensors. The display and control panel of the evaluating processor unit indicates the smoke concentration of the sampled air and other alarm fault and status messages. Any increase in the smoke concentration is detected very early. Three pre-alarms and two main alarms can be programmed for each and signalled via volt free relays contacts. There are four expansion slots for accommodating modular 1 x network card 1 x memory card and 2 relay cards.The ASD 535 is ideal for property and space surveillance thanks to its excellent response behaviour and is used whenever conventional point-type smoke detectors cannot be used. This may be due for example to ambient conditions too hot too cold too dirty or because operating conditions are such that access is highly restricted prisons false ceilings clean rooms laboratories high rack storage facilities etc.. Or because lightning-fast detection is required e.g. in data centres.Key FeaturesLatest generation of universal aspiration smoke detectors1 or 2 sampling lines with separate sensors and air flow monitoringEN54-20 classes A B and CVds certified calculation software ASD PipeFlow enables efficient asymmetrical pipe layout4 alarm levels 3 pre-alarms and 2 alarmsResolution 0.001mInsensitive to pollutants thanks to particle suppressionAuto-learning functionLow noise level compliant with ISO 11690-1Refined smoke detection thanks to HD sensor high-dynamic technologyLow power consumptionHigh performance suction 400 Pa vacuumIndividually replaceable

GBP 3385.20
1

Patol ASD535-2 Dual Sensor Standard Display with Two SSD535-3 Detectors

Patol ASD535-2 Dual Sensor Standard Display with Two SSD535-3 Detectors

Patol ASD535-2 Dual Sensor Standard Display with Two SSD535-3 DetectorsThe ASD 535 Aspirating Smoke Detector is the new generation of highly sensitive active smoke detection system. It offers application specific sensitivity adjustment alongside pre-signalling and pollution analyses. The ASD 535 detects even minuscule glowing and smouldering fires and can be deployed practically anywhere.The ASD 535 consists of one or two independent sampling lines with sampling apertures each with a highly sensitive smoke sensor. Air flow monitoring ensures that the sampling lines are constantly checked for pipe breakage and the sampling holes monitored for pollution. A high-performance ventilator draws the air from the room or facility being monitored through the sampling line to the evaluating processor unit.There the air is continuously evaluated by the smoke sensors. The display and control panel of the evaluating processor unit indicates the smoke concentration of the sampled air and other alarm fault and status messages. Any increase in the smoke concentration is detected very early. Three pre-alarms and two main alarms can be programmed for each and signalled via volt free relays contacts. There are four expansion slots for accommodating modular 1 x network card 1 x memory card and 2 relay cards.The ASD 535 is ideal for property and space surveillance thanks to its excellent response behaviour and is used whenever conventional point-type smoke detectors cannot be used. This may be due for example to ambient conditions too hot too cold too dirty or because operating conditions are such that access is highly restricted prisons false ceilings clean rooms laboratories high rack storage facilities etc.. Or because lightning-fast detection is required e.g. in data centres.Key FeaturesLatest generation of universal aspiration smoke detectors1 or 2 sampling lines with separate sensors and air flow monitoringEN54-20 classes A B and CVds certified calculation software ASD PipeFlow enables efficient asymmetrical pipe layout4 alarm levels 3 pre-alarms and 2 alarmsResolution 0.001mInsensitive to pollutants thanks to particle suppressionAuto-learning functionLow noise level compliant with ISO 11690-1Refined smoke detection thanks to HD sensor high-dynamic technologyLow power consumptionHigh performance suction 400 Pa vacuumIndividually replaceable

GBP 3114.72
1

Patol ASD535-1 Single Sensor Standard Display with SSD535-3 Detector

Patol ASD535-1 Single Sensor Standard Display with SSD535-3 Detector

Patol ASD535-1 Single Sensor Standard Display with SSD535-3 DetectorThe ASD 535 Aspirating Smoke Detector is the new generation of highly sensitive active smoke detection system. It offers application specific sensitivity adjustment alongside pre-signalling and pollution analyses. The ASD 535 detects even minuscule glowing and smouldering fires and can be deployed practically anywhere.The ASD 535 consists of one or two independent sampling lines with sampling apertures each with a highly sensitive smoke sensor. Air flow monitoring ensures that the sampling lines are constantly checked for pipe breakage and the sampling holes monitored for pollution. A high-performance ventilator draws the air from the room or facility being monitored through the sampling line to the evaluating processor unit.There the air is continuously evaluated by the smoke sensors. The display and control panel of the evaluating processor unit indicates the smoke concentration of the sampled air and other alarm fault and status messages. Any increase in the smoke concentration is detected very early. Three pre-alarms and two main alarms can be programmed for each and signalled via volt free relays contacts. There are four expansion slots for accommodating modular 1 x network card 1 x memory card and 2 relay cards.The ASD 535 is ideal for property and space surveillance thanks to its excellent response behaviour and is used whenever conventional point-type smoke detectors cannot be used. This may be due for example to ambient conditions too hot too cold too dirty or because operating conditions are such that access is highly restricted prisons false ceilings clean rooms laboratories high rack storage facilities etc.. Or because lightning-fast detection is required e.g. in data centres.Key FeaturesLatest generation of universal aspiration smoke detectors1 or 2 sampling lines with separate sensors and air flow monitoringEN54-20 classes A B and CVds certified calculation software ASD PipeFlow enables efficient asymmetrical pipe layout4 alarm levels 3 pre-alarms and 2 alarmsResolution 0.001mInsensitive to pollutants thanks to particle suppressionAuto-learning functionLow noise level compliant with ISO 11690-1Refined smoke detection thanks to HD sensor high-dynamic technologyLow power consumptionHigh performance suction 400 Pa vacuumIndividually replaceable

GBP 2073.12
1