24 results (0,13687 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

STI STI-9705 Damage Stopper For HornStrobeSpeaker Flush Mount

STI STI-9635 Small 12in Clock-Bell Damage Stopper Guard

STI STI-9635-SS Small Wire Cage for Clocks - Stainless Steel Special

STI STI-9714 Steel Cage for SPECTRAlert Horns

C-Tec QT616 Quantec InfraredRadio Fall Sensor

C-Tec BF560-24 Switch Mode 24v 1.5A EN54-4 Boxed PSU

STI STI-9637-SS Large Wire Cage for Clocks - Stainless Steel

STI STI-9637 Large 24in Clock-Bell Damage Stopper Guard

C-Tec 24V 5A EN54-4 Switch Mode PSU BF562-5

STI 9605 Deep Steel Smoke Detector Cage

STI STI-14200NR-Z003 Universal Stopper Cover And Quickstop Fire Sprinkler Tool

C-Tec 24V 5A 5 Series Encased Power Supply PCB ONLY BF562-5E

STI 9604 Low Profile Steel Smoke Detector Cage 315-001

C-Tec 24V 1.5A 5 Series Encased Power Supply PCB ONLY BF560-24E

C-Tec 24V 3A 5 Series Encased Power Supply PCB ONLY BF562-3E

STI STI-14000NC Universal Stopper- Low Profile Without Horn Housing - Flush

STI STI-14000NC Universal Stopper- Low Profile Without Horn Housing - Flush

STI STI-14000NC Universal Stopper- Low Profile Without Horn Housing - FlushThis unique Indooroutdoor polycarbonate cover helps stop false fire alarms without restricting legitimate operation of pull stations. This tough polycarbonate cover is ideal for schools hospitals nursing homes stores hotels and public buildings of almost every kind. The strong durable construction takes the toughest knocks while it guards against accidental or intentional physical damage. The cover is 4 inches in depth and clear flush mount with a clear housing. Sized to fit most pull stations. It protects pull stations keypads intercom stations emergency buttons electrical light switches etc. It is ADA Compliant and ULCUL Listed for US and Canadian safety standards. Stopper is UV-Stabilized to keep cover clear from the elements. There are mounting options that consist of a flush mount cover or a waterproof Type 4X enclosed back box or low profile surface mount cover with a clear conduit spacer. Three year guarantee against breakage of polycarbonate in normal use. Polycarbonate rated -40 F to 250 F -40 C to 121 C. STI We protect the things that protect you.Key FeaturesIndoor outdoor low profile cover for flush mount protects against vandalism and accidental damageProtects keypads intercom stations emergency buttons electrical light switches duplex plugs. etc. from accidental activationCover molded from thick tough polycarbonate materialHigh strength continuous hingeThree year guarantee against breakage of the polycarbonate in normal use

GBP 45.44
1

STI EM362408WA Grey Metal Cabinet Window Door - 110V AH

STI EM362408WA Grey Metal Cabinet Window Door - 110V AH

STI EM362408WA Grey Metal Cabinet Window Door - 110V AHThis ACheated enclosure allows alarm control panels to be protected from extreme temperatures or other areas requiring UL Type 4 protection.The extra large super tough heavy-duty metal enclosure guards against vandalism either accidental or intentional as well as dirt dust and grime. Its size allows the enclosure to house significantly sized electronic devices with space to spare. This UL Type 4 enclosure mounts to the wall enabling the units to be protected in their designated location.Unlike competitive models this enclosure is available with a clear window allowing the unit within to be quickly identified. Both the enclosure and ACheater unit have a durable finish to help protect against corrosion. The enclosure has two turn latches to help prevent unauthorized entry.Key FeaturesLocks sold separatelyConstructed of super tough heavy-duty 14 gauge metal with baked enamel finishProtects fire alarm control panels and large electronic devices from extreme temperaturesACHeater unit is externally mounted to minimize space intrusionACHeater unit cycles and a fan runs continuously to sustain a uniform temperature inside the enclosureCost effective low maintenance and compact designIncludes mounting plateTwo 14 turn latches help prevent unauthorized entryMounts to the wall enabling units to be protected in their designated locationCabinet is Type 4 UL Listed CEACHeater unit ULcUL Listed CE36 in H x 24 in W x 8 in D

GBP 6600.86
1

C-Tec BF560-12E Switch Mode 12v 2A Caged PSU PCB

C-Tec BF560-12E Switch Mode 12v 2A Caged PSU PCB

C-Tec BF560-12E Switch Mode 12v 2A Caged PSU PCBTheBF560-12E is apowerful switch modedigital hybrid PSU that can be customised to suit your exact requirements. The plasticcoveron PSU PCB guards against touching live parts to VDE 0100-410. Includes the same electronics as the BF560-12 LPCBcertified EN54-4A2 boxed 12V 2A PSU.Key FeaturesMetal base platefacilitatesstraightforwardmountinginside third-party OEMenclosures.Includes a single-pole voltfree changeover relay that switches for any fault condition.Includes afault type hazardous voltages present LED.Two selectable battery charge currents.Battery fault impedance limits can be optimised to suit load current helps extend battery life.Mains fail simulation mode.Improved on-board temperature sensor with optional remote sensor.Electronic functions comply with EN50131-6 grades 1-4 for security applications.Additional InformationEN50131-6 POWER SUPPLIES FOR INTRUSION HOLD UP ALARMS CAPABILITYThe BF560-12E has all the electrical functions required to comply with EN50131-6 Grade 4which includes Grades 3 2 and 1. OEM security companies interested in utilising the BF560-12E inside their own EN50131-6 compliant tamper-resistant enclosures should contact our marketing departmentfor further detailson costs and approvals.PSU CUSTOMISATIONThe BF560-12Ecan be customised to suit your exact requirements using a BF423 configurator PC. Configurable parameters include float voltage temperature compensation battery charge rate mA battery impedance and configurableInputOutput settingsPSU STATUS LEDlocated on the PSU PCB1 flash Mains Failure.2 flashes Battery Voltage Low.3 flashes Battery Voltage Critical.4 flashes Charger Failure.5 flashes Charger OK Battery is either actively charging or in float charge.6 flashes No Batteries Fitted indicating DIP Switch 4 position.7 flashes Battery Resistance Fault Level set by DIP Switch 2 position.8flashes Output Over Voltage.BATTERY FAULT MONITORINGThe BF560-12E monitors battery resistance to the requirements of EN54-4A2. The fault threshold is directly related to the ability of the battery to deliver the rated current to the load. For example batteries stored uncharged for long periods during shipment andor distribution degrade leading to increased internal resistance. If a degraded battery is fitted a fault will be shown by the PSU as mandated by EN54-4A2.DATA PORTData on the BF560-12Es status can be extracted from the PSUsbi-directional data port. The data availableincludes thermistor measurements battery terminal voltage system voltage at load terminals battery charge current load current battery impedanceandASCII text string status messages. Extracting this data requires additional equipment and permissions - contact C-TEC for details.

GBP 70.52
1

C-Tec BF562-1 Switch Mode 24v 1.5A EN54-4 Boxed Metal PSU

C-Tec BF562-1 Switch Mode 24v 1.5A EN54-4 Boxed Metal PSU

C-Tec BF562-1 Switch Mode 24v 1.5A EN54-4 Boxed Metal PSUThe BF562-1 is certified to EN54-4A2 by the LPCB and VdS AFNOR pending. It comes with a plastic cover on PSU PCB which guards against touching live parts. Includes a single-pole voltfree changeover relay that switches for any fault condition.Key FeaturesMultiple indicators - supply present general fault fault type aux. equipment faultTwo selectable battery charge currentsBattery fault impedance limits can be optimised to suit load current helps extend battery lifeMains fail simulation modeImproved on-board temperature sensor with optional remote sensorElectronic functions comply with EN50131-6 grades 1-4 for security applicationsBF562-1E caged BF562-1C PCB-only versions availableTYPICAL USESIdeal for poweringbeam detectors auto-dial communicators aspirating smoke detectors auto-open vent systems auxiliary sounder systems or any other device performing a mandatory function of a fire alarm system.PSU CUSTOMISATIONThe BF562-1can be customised to suit your exact requirements using a BF423 configurator PC. Configurable parameters include float voltage temperature compensation battery charge rate mA battery impedance and configurableInputOutput settings. It is important to note changing the PSUs parameters in this way isoutside the scope of EN54-4 and any changes mustbe tested by the responsible person for correctoperation.PSU STATUS LEDlocated on the PSU PCB1 flash Mains Failure.2 flashes Battery Voltage Low.3 flashes Battery Voltage Critical.4 flashes Charger Failure.5 flashes Charger OK Battery is either actively charging or in float charge.6 flashes No Batteries Fitted indicating DIP Switch 4 position.7 flashes Battery Resistance Fault Level set by DIP Switch 2 position.8flashes Output Over Voltage.BATTERY FAULT MONITORINGThe BF562-1 complies with EN54-4A2 and therefore must monitor battery resistance. The fault threshold is directly related to the ability of the battery to deliver the rated current to the load. For example batteries stored uncharged for long periods during shipment andor distribution degrade leading to increased internal resistance. If a degraded battery is fitted a fault will be shown by the PSU as mandated by EN54-4A2.DATA PORTData on the BF562-1s status can be extracted from the PSUsbi-directional data port. The data availableincludes thermistor measurements battery terminal voltage system voltage at load terminals battery charge current load current battery impedanceandASCII text string status messages. Extracting this data requires additional equipment and permissions - contact C-TEC for details.

GBP 155.72
1

Scope PTPRO2R PageTek Pro 2 Paging transmitter

Scope PTPRO2R PageTek Pro 2 Paging transmitter

Please note The image is for illustrative purposes only - thistransmitter does not come with an aerial included. Compatible aerials can bepurchased separately please see related products below.Scope PTPRO2R PageTek Pro 2 Paging transmitterThe PTPRO2R manufactured by Scope is a high-power pagetransmitter for hard of hearing.Scope PageTek Pro 2 Industrial Strength paging systems designed for use with professional Fire and Security systems installed in commercialindustrial premises. The system is primarily designed to alert the hearing impaired in the event of a fire or other emergency where an audible sounder is the normal means of indication. Main users include factories offices universities schools hospitals hotels and public buildings.The Pagetek Pro System is designed to comply with the recommendations detailed in BS5839-1 2013 for alerting the hearing impaired to the activation of a Fire Alarm System. The system can also be used in conjunction with a security alarm panel to alert guards who might be located remote from the main premises.The interface to the host Fire alarm system comprises of multiple prioritised Fire inputs and a further input to provide for fault indication from the Fire panel. For ease of installation a monitored interface cable is provided with the system which also includes a common fault relay output back to the host Fire alarm panel. This will activate if the PageTek Pro suffers a mains failure transmitter fault antenna mismatch link failure low battery or missing battery condition.Upon activation of any Fire Zone input the PageTek Pro system will enter the fire alert condition prioritising and transmitting the Fire message to all pagers. The transmissions will be repeated until the fire condition is reset. Special format Scope pagers ensure that users are alerted by distinct vibrate patterns and clear text messages.Key Features2.0W RF outputRequires aerial pagers 18Ah batteryBS5839-1 certifiedUHF radio link for maximum licensable protectionUnique coding avoids neighbouring system clashesSelf-monitoring of system healthRugged steel enclosure to IP65Backlit 2 line Text Display continuously reports system statusAdditional Visible Audible status indicatorsPrioritised Fire Alarm Inputs and Fault inputsAutomated test calls alert pagers to loss of radio signalFault notification to the host Control Equipment via monitored linkKey locked System Test facility for routine confidence checkingOver 90 hours backup operation with internally fitted batteryAdd on AnswerTek Pro receiver system for additional monitoring reporting of radio signal IntegrityRS232 serial input for other messagingOptional Ethernet card and additional RS232 inputHigh power transmitter provides 2w ERP RF output for enhanced coverage of large sites

GBP 1904.76
1

Scope PTPRO2RM PageTek Pro 2 High Power Paging Transmitter

Scope PTPRO2RM PageTek Pro 2 High Power Paging Transmitter

Please contact us to confirm panel compatibility andconfiguration before orderingScope PTPRO2RM PageTek Pro 2 High Power Paging TransmitterThe PTPRO2RM manufactured by Scope is a high-power pagetransmitter for hard of hearing.Scope PageTek Pro 2 Industrial Strength paging systems designed for use with professional Fire and Security systems installed in commercialindustrial premises. The system is primarily designed to alert the hearing impaired in the event of a fire or other emergency where an audible sounder is the normal means of indication. Main users include factories offices universities schools hospitals hotels and public buildings.The Pagetek Pro System is designed to comply with the recommendations detailed in BS5839-1 2013 for alerting the hearing impaired to the activation of a Fire Alarm System. The system can also be used in conjunction with a security alarm panel to alert guards who might be located remote from the main premises.The interface to the host Fire alarm system comprises of multiple prioritised Fire inputs and a further input to provide for fault indication from the Fire panel. For ease of installation a monitored interface cable is provided with the system which also includes a common fault relay output back to the host Fire alarm panel. This will activate if the PageTek Pro suffers a mains failure transmitter fault antenna mismatch link failure low battery or missing battery condition.Upon activation of any Fire Zone input the PageTek Pro system will enter the fire alert condition prioritising and transmitting the Fire message to all pagers. The transmissions will be repeated until the fire condition is reset. Special format Scope pagers ensure that users are alerted by distinct vibrate patterns and clear text messages.Key Features2.0W RF output with serial input from third-party panelRequires aerial pagers 18Ah batteryBS5839-1 certifiedUHF radio link for maximum licensable protectionUnique coding avoids neighbouring system clashesSelf-monitoring of system healthRugged steel enclosure to IP65Backlit 2 line Text Display continuously reports system statusAdditional Visible Audible status indicatorsPrioritised Fire Alarm Inputs and Fault inputsAutomated test calls alert pagers to loss of radio signalFault notification to the host Control Equipment via monitored linkKey locked System Test facility for routine confidence checkingOver 90 hours backup operation with internally fitted batteryAdd on AnswerTek Pro receiver system for additional monitoring reporting of radio signal IntegrityRS232 serial input for other messagingOptional Ethernet card and additional RS232 inputHigh power transmitter provides 2w ERP RF output for enhanced coverage of large sitesPlease note The image is for illustrative purposes only - thistransmitter does not come with an aerial included. Compatible aerials can bepurchased separately please see related products below.

GBP 2007.72
1

Scope PTPRO2L PageTek Pro 2 Paging Transmitter For The Hard Of Hearing - 1.0W RF Output

Scope PTPRO2L PageTek Pro 2 Paging Transmitter For The Hard Of Hearing - 1.0W RF Output

Please note The image is for illustrative purposes only - this transmitter does not come with an aerial included. Compatible aerials can be purchased separately please see related products below.Scope PTPRO2L PageTek Pro 2 Paging Transmitter For The Hard Of Hearing - 1.0W RF OutputThe PTPRO2L is a PageTek Pro 2 Paging Transmitter For The Hard Of Hearing - 1.0W RF Output.Scope PageTek Pro 2 Industrial Strength paging systems designed for use with professional Fire and Security systems installed in commercialindustrial premises. The system is primarily designed to alert the hearing impaired in the event of a fire or other emergency where an audible sounder is the normal means of indication. Main users include factories offices universities schools hospitals hotels and public buildings.The Pagetek Pro System is designed to comply with the recommendations detailed in BS5839-1 2013 for alerting the hearing impaired to the activation of a Fire Alarm System. The system can also be used in conjunction with a security alarm panel to alert guards who might be located remote from the main premises.The interface to the host Fire alarm system comprises of multiple prioritised Fire inputs and a further input to provide for fault indication from the Fire panel. For ease of installation a monitored interface cable is provided with the system which also includes a common fault relay output back to the host Fire alarm panel. This will activate if the PageTek Pro suffers a mains failure transmitter fault antenna mismatch link failure low battery or missing battery condition.Upon activation of any Fire Zone input the PageTek Pro system will enter the fire alert condition prioritising and transmitting the Fire message to all pagers. The transmissions will be repeated until the fire condition is reset. Special format Scope pagers ensure that users are alerted by distinct vibrate patterns and clear text messages.Key FeaturesUHF radio link for maximum licensable protectionUnique coding avoids neighbouring system clashesSelf-monitoring of system healthRugged steel enclosure to IP65Backlit 2 line Text Display continuously reports system statusAdditional Visible Audible status indicatorsPrioritised Fire Alarm Inputs and Fault inputsAutomated test calls alert pagers to loss of radio signalFault notification to the host Control Equipment via monitored linkKey locked System Test facility for routine confidence checkingOver 90 hours backup operation with internally fitted batteryAdd on AnswerTek Pro receiver system for additional monitoring reporting of radio signal IntegrityRS232 serial input for other messagingOptional Ethernet card and additional RS232 inputHigh power transmitter provides 2w ERP RF output for enhanced coverage of large sites

GBP 1801.80
1

Scope PTPRO2LM PageTek Pro 2 Paging Transmitter For The Hard Of Hearing - With Serial

Scope PTPRO2LM PageTek Pro 2 Paging Transmitter For The Hard Of Hearing - With Serial

Please note The image is for illustrative purposes only - thistransmitter does not come with an aerial included. Compatible aerials can bepurchased separately please see related products below.Scope PTPRO2LM PageTek Pro 2 Paging Transmitter For The Hard Of Hearing - With SerialThe PTPRO2LM is a PageTek Pro 2 Paging Transmitter For The Hard Of Hearing - With Serial.Scope PageTek Pro 2 Industrial Strength paging systems designed for use with professional Fire and Security systems installed in commercialindustrial premises. The system is primarily designed to alert the hearing impaired in the event of a fire or other emergency where an audible sounder is the normal means of indication. Main users include factories offices universities schools hospitals hotels and public buildings.The Pagetek Pro System is designed to comply with the recommendations detailed in BS5839-1 2013 for alerting the hearing impaired to the activation of a Fire Alarm System. The system can also be used in conjunction with a security alarm panel to alert guards who might be located remote from the main premises.The interface to the host Fire alarm system comprises of multiple prioritised Fire inputs and a further input to provide for fault indication from the Fire panel. For ease of installation a monitored interface cable is provided with the system which also includes a common fault relay output back to the host Fire alarm panel. This will activate if the PageTek Pro suffers a mains failure transmitter fault antenna mismatch link failure low battery or missing battery condition.Upon activation of any Fire Zone input the PageTek Pro system will enter the fire alert condition prioritising and transmitting the Fire message to all pagers. The transmissions will be repeated until the fire condition is reset. Special format Scope pagers ensure that users are alerted by distinct vibrate patterns and clear text messages.Key FeaturesUHF radio link for maximum licensable protectionUnique coding avoids neighbouring system clashesSelf-monitoring of system healthRugged steel enclosure to IP65Backlit 2 line Text Display continuously reports system statusAdditional Visible Audible status indicatorsPrioritised Fire Alarm Inputs and Fault inputsAutomated test calls alert pagers to loss of radio signalFault notification to the host Control Equipment via monitored linkKey locked System Test facility for routine confidence checkingOver 90 hours backup operation with internally fitted batteryAdd on AnswerTek Pro receiver system for additional monitoring reporting of radio signal IntegrityRS232 serial input for other messagingOptional Ethernet card and additional RS232 inputHigh power transmitter provides 2w ERP RF output for enhanced coverage of large sites

GBP 1904.76
1

C-Tec BF560-12 Switch Mode 12v 2A EN54-4 Boxed PSU

C-Tec BF560-12 Switch Mode 12v 2A EN54-4 Boxed PSU

C-Tec BF560-12 Switch Mode 12v 2A EN54-4 Boxed PSUThe C-Tec BF560-12 12V 2A EN54-4 Switch Mode PSU is ideal for connecting to 12V security STUs to provide BS5839-1 compliant remote monitoring facilities. It is certified to EN54-4A2 by the LPCB VdS AFNOR pending.Key FeaturesMultiple indicators - supply present general fault fault type aux. equipment fault.Two selectable battery charge currents.Battery fault impedance limits can be optimised to suit load current helps extend battery life.Mains fail simulation mode.Improved on-board temperature sensor with optional remote sensor.Ideal for connecting to 12V security STUs to provide BS5839-1 compliant remote monitoring facilities.Electronic functions comply with EN50131-6 grades 1-4 for security applications.BF560-12E Caged BF560-12C PCB-only versions available.Plastic cover on PSU PCB guards against touching live parts.Includes a single-pole voltfree changeover relay that switches for any fault condition.Additional InformationPSU CUSTOMISATIONThe BF560-12can be customised to suit your exact requirements using a BF423 configurator PC. Configurable parameters include float voltage temperature compensation battery charge rate mA battery impedance and configurableInputOutput settings. It is important to note changing the PSUs parameters in this way isoutside the scope of EN54-4 and any changes mustbe tested by the responsible person for correctoperation.12V SECURITY STUUSED PURELY FOR FIRE ALARM SIGNALLINGThe BF560-12 can help combat an area of fire alarm system non-compliance that is often overlooked - their connection to remote monitoring centres via 12V security STUs or autodiallers. Firesystems that require such monitoring are typically connected to 12V security STUs. Unfortunately PSUs used to power these STUs normally only offer 12 hours standby are notconnected to a dedicated mains supply and do not include the features demanded by EN54-4 such as battery impedance monitoring temperature compensated charging CPR compliance etc. TheBF560-12 solves these problems by allowing the use of 12V STUs with a cost-effective EN54-4 compliant PSU thereby facilitating compliance with BS5839-1 or European equivalents. Tofurther assist this application an optional STU mounting plate is available for inside the BF560-12 order code BF360SP.PSU STATUS LEDlocated on the PSU PCB1 flash Mains Failure.2 flashes Battery Voltage Low.3 flashes Battery Voltage Critical.4 flashes Charger Failure.5 flashes Charger OK Battery is either actively charging or in float charge.6 flashes No Batteries Fitted indicating DIP Switch 4 position.7 flashes Battery Resistance Fault Level set by DIP Switch 2 position.8flashes Output Over Voltage.BATTERY FAULT MONITORINGThe BF560-12 complies with EN54-4A2 and therefore must monitor battery resistance. The fault threshold is directly related to the ability of the battery to deliver the rated current to the load. For example batteries stored uncharged for long periods during shipment andor distribution degrade leading to increased internal resistance. If a degraded battery is fitted a fault will be shown by the PSU as mandated by EN54-4A2.EN50131-6 POWER SUPPLIES FOR INTRUSION HOLD UP ALARMS CAPABILITYThe power supply inside the BF560-12 has all the electrical functions required to comply with EN50131-6 Grade 4which includes Grades 3 2 and 1. However the BF560-12s enclosure isnot designed to comply with the standardsrequirements totriggeranalarm if someone tries to force the box open. OEM security companies interested in utilising the BF560-12s PSUPCB inside their own EN50131-6 compliant tamper-resistant enclosures should contact our marketing departmentfor further detailson costs and approvals.DATA PORTData on the BF560-12s status can be extracted from the PSUsbi-directional data port. The data availableincludes thermistor measurements battery terminal voltage system voltage at load terminals battery charge current load current battery impedanceandASCII text string status messages. Extracting this data requires additional equipment and permissions -call C-TEC for details.

GBP 113.64
1