13.069 results (0,17606 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Testifire XTR2 TESTIFIRE-ADAP-001 Adaptor for ASD and Flat Detectors

Testifire XTR2 TESTIFIRE-MEML-001 Membrane for USA amp Middle East Regions

Zeta ZT-MH Zeta Mains Heat Detector with 9V Battery Back-Up LPCB Approved

Zeta ZT-MSH Zeta Mains Smoke amp Heat Detector with 9V Battery Backup LPCB Approved

Testifire XTR2 TES3-6PACK-001 Smoke Cartridge - Pack Of 6

Testifire XTR2 TES3-3PACK-001 Smoke Cartridge - Pack Of 3

Ziton ZP1-F2-MB ZP1 Main Board - 2 Zone Replacement Main PCB for the ZP1-F2-xx

Ziton ZP1-F2-MB ZP1 Main Board - 2 Zone Replacement Main PCB for the ZP1-F2-xx

Ziton ZP1-F2-MB ZP1 Main Board - 2 Zone Replacement Main PCB for the ZP1-F2-xxThe ZP1-F2-MB is a ZP1 Main Board - 2 Zone Replcement Main PCB designed for theZP1-F2 range.ZP1 fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mid-sized conventional applications. They feature an attractive contemporary design that fits with any decor. The gently curved door front offers a distinctive flair. Operator controls are inset in a striking blue lexan.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.The PanelThe ZP1-F2 is a conventional fire alarm control panel. It is supplied in local language with 2 zones that support up to 32 devices per zone as well as up to 2 supervised relay outputs dedicated to sounder control. In addition 2 conventional relay outputs dedicated to common fire and fault conditions as well as two user configurable inputs for monitoring and control are available.OptionsThe panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 8 additional outputs.Approvals ComplianceThe product line carries the following accreditationsRoHS compliantWEEE compliantNEN2535 NBNS21-100 and BS5839-1 compliantCPD certifiedEN542 EN544 and CE approvedType class conditions 3K5 of IEC 60721-3-3Key FeaturesModern elegant designEasy removable parts for quick and clean installationDefault regional setup modesNormal head-out intrinsically safe zone supportSupervised alarm notification outputsEN54 compliant potential free fire fault relaysClass change daynight remote reset facilitiesAuxiliary 24VDC supply output with reset supportDefault support for special functions such as - EN54 compliant user access levels - mixed zones - full front panel diagnostics - one-man walk testAuxiliary standard supervised relay output boardsNetworkable up to 64 zones

GBP 180.13
1

Ziton ZR4ST-3 ZR4 Series 868 MHz Site Survey Tool for Wireless Installations

Ziton ZR4ST-3 ZR4 Series 868 MHz Site Survey Tool for Wireless Installations

Ziton ZR4ST-3 ZR4 Series 868 MHz Site Survey Tool for Wireless InstallationsThe ZR4ST-3 is a portable radio survey kit to assist in the validation of an 868 MHz wireless fire alarm system prior to installation. A site survey is always required prior to installation for all wireless devices to ensure full system operability after installation.Operating PrincipleFire systems are often required in buildings where cable wiring presents a challenge because the fabric of the building or where the interior design would be negatively affected by the use of cables. It could also be difficult to introduce cable runs into old buildings that were not designed with a modern cable infrastructure. It is in these architecturally sensitive buildings that wireless fire detection is ideal.The ZR4ST-3 survey tool helps establish the viability of a wireless installation in such buildings by allowing a pre-installation survey to be conducted within the standard operating parameters of the system. The ZR4ST-3 confirms the signal strength at every desired location and helps with the overall system design by providing clear go no-go location information.The RangeA typical 868 MHz fire system may consist ofWired or wireless interface modulesWireless fire detectorsWireless notification devicesWireless detectornotification device combinationsWireless manual call pointsWireless inputoutput modulesAll of these require validation for signal strength prior to installation.

GBP 647.00
1

Vox Ignis ViAC-RTK-SS Assist Call Remote Kit

Kidde 1X-F4-03 Conv Fire Panel With UI and EOL Units - 4 Zone English UK

Ziton FD310H - Additional Detector Pair 5 - 120m for FD310

Ziton FD310H - Additional Detector Pair 5 - 120m for FD310

ZitonFD310H - Additional Detector Pair 5 - 120m for FD310The FD310 End to End infrared Optical Beam Smoke Detector OBSD has been designed using the latest optical technology incorporating modern industrial electronic and software techniques. This detector offers cost effective protection of large open area spaces with high ceilings. It is also very suited to applications where access to ceiling mounted smoke detectors presents practical difficulties.OperationThe system comprises a modern looking Transmitter head which emits a narrow beam of infra-red light to an associated Receiver head with a compact Low Level Controller. Once smoke crosses through and thus obscures the IR beam path the signal strength at the Receiver drops below a preset level which in turn results in an alarm condition. Both the detector heads Transmitter and Receiver have integrated alignment thumbwheels for ease of alignment. Using these thumbwheels provides a smooth and repeatable alignment process. The detector heads have up to 10 degrees of adjustment in both planes. For further adjustment a bespoke Adjustment Bracket is available which offers up to 180 degrees movement in both planes as well as a full 360-degree rotation.The FD310 has been designed so that it can be installed by one operator with its laser assisted alignment method combined with easy to use alignment LEDs offering a visual feedback. Integrated laser alignment aid can be activated at the Controller or at the Receiver head.The low level Controller incorporates a LCD display which offers a full icon-based easy-to-use interface unit. This Controller enables ease of commissioning testing and maintenance of the beam detection system. During commissioning the detector sensitivity and fire thresholds can be selected along with the user variable time to fire and time to fault settings.Key FeaturesSeparate Transmitter and Receiver HeadsRange 5 to 120 metres configurable per set of DetectorsIntegral Laser Alignment in Receiver2-wire Interface between Controller and ReceiverSingle and Twin Detector optionsSeparate Fire and Fault Relays per DetectorLow Level Controller with LCD displayProgrammable Sensitivity and Fire ThresholdAutomatic Gain Control AGC for drift compensationFirst Fix concept for Transmitter Receiver and ControllerMultiple cable gland knockouts for ease of wiringOptional Transmitter powering from Controller

GBP 789.20
1

Zeta ZT-MSH Zeta Mains Smoke amp Heat Detector with 9V Battery Backup LPCB Approved

Ziton ZP2-F2 Addressable Fire Panel With User Interface 2 Loop

Ziton ZP2-F1-S Addressable Fire Panel With User Interface 1 Loop Small Cabinet

Ziton ZP2-F1 Addressable Fire Panel With User Interface 1 Loop

Ziton ZP2-F2-S Addressable Fire Panel With User Interface 2 Loop Small Cabinet

Apollo Orbis TimeSaver Base - ORB-MB-00001-APO

Apollo Orbis TimeSaver Sav-Wire Base ORB-SW-10005-APO

Apollo Orbis TimeSaver Deep Base - ORB-MB-00019-APO