48 results (0,13025 seconds)

Brand

Size

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Amplivox - IP30-10 Insert Earphones (IP30 10 Ohm)

Amplivox - SPIROLAB Spirometer

Amplivox - ER75 Electro-acoustic ear simulator

Amplivox - ER75 Electro-acoustic ear simulator

Product Properties The ER-75 electro-acoustic ear simulator is the perfect solution for performing objective validation of audiometers and audiometric equipment, ensuring optimum performance when testing for hearing loss. Testing Tests provide repeatable thresholds over the frequency range of 0.25kHz to 8kHz, thereby simulating the patient response and enabling the user to identify hearing loss issues. This ensures compliance at all hearing test frequencies used in an actual hearing assessment. Fast and efficient Instrument validation can be completed in under 5 minutes, allowing users to identify if the audiometric facility (audiometer, booth, headset and all associated cables) are performing in an accurate manner. Any changes to the measurements can then be identified by comparing with previous results and remedial actions can be taken to ensure test accuracy. Automatic As the simulator is completely automatic, validations are carried out using standard and Audiocup configured audiometry headphones (connected to the audiometer), which are placed over the ER-75’s built-in microphones. Portability At only 500g (1.1lbs), battery powered and with a lightweight and compact design, the ER-75 can be used for both static and mobile requirements. Key Features Automatic audiometer validation in under 5 minutes Repeatable thresholds over 0.25-8kHz Battery powered Compact, lightweight and portable Please note: The circumference of a headset must be big enough to sit comfortably on the ER-75 to form a seal (the unit is not considered suitable for a Pelter headset). Validation testing should be considered as an essential part of the test programme and can be required should there be an audit of the medical services.

GBP 930.00
1

Amplivox - A200 Insert Earphones (Eartone 5A 10 Ohm)

Amplivox - Otoaccess Database

Amplivox - Otoaccess Database

Product Properties Data management  for seamless patient handling OtoAccess ®  is a patient data management system which enables easy and secure patient data handling - all in one system.  Together with our Amplisuite audiometry and tympanometry modules, OtoAccess ®  covers all integration needs by seamlessly integrating with software suites as well as Electronic Health Record (EHR) systems to allow for patient data transfer between major healthcare facilities. Combining advanced functionality with a simple user experience, it is an ideal solution for any healthcare professional. Consists of three integration solutions: OtoAccess ®  Database, OtoAccess ®  Worklist HL7 and OtoAccess ®  API.  OtoAccess ®   supports the full line of Amplivox audiology products, allowing you to access all patient data in one common interface. This makes it easier and faster for you to gather a holistic overview of your patient without having to switch between different modules. With quick session previews and one-click access to reports, you can easily access information about each individual patient all in one interface, freeing up time for what actually matters: your patients.  Covering all your patient data needs No PDF exports. No uploads. No printouts. No scanning. Optimised workflows and robust data handling can also be achieved with OtoAccess ®   Worklist HL7 and if you use another database, OtoAccess ®   API can integrate your solutions with third-party databases. Images for illustration purposes only, actual product may differ .

GBP 650.25
1

Amplivox - 116 Manual screening audiometer - optional audiocups and battery, Not required

Amplivox - 116 Manual screening audiometer - optional audiocups and battery, Not required

Product Properties Cost-effective and easy-to-use, the Model 116 is an essential tool for completing hearing tests within schools, primary care and GP surgeries. Ergonomic design Designed with the operator in mind, the Model 116 has a clear display panel and dedicated soft key layout, allowing total focus on the test subject and reducing the time it takes to complete hearing assessments.  Time saving The audiometer includes all test frequencies and attenuation ranges required to perform a wide range of pure tone audiometry, such as standard threshold or sweep testing for school screening. It offers pure, pulsed, warble and continuous tones which allow for the testing and identification of hearing issues in subjects with tinnitus, presbycusis and noise induced hearing loss (NIHL). Automatic threshold results saving significantly reduces operator test times and increases attention of the test subject for more accurate results.  Portability At only 720g (1.58lbs), the lightweight and robust design of the Model 116 is perfect for healthcare professionals who need to travel. It also comes supplied with a custom carry case and all standard accessories. The optional battery power function can be used in all test settings, offering additional flexibility Data management Test results can be manually recorded, printed via the optional portable printer and or transferred to PC applications such as Amplivox Amplisuite or Audibase to create both PDF or printed copy. This ensures results can be saved within third-party Electronic medical record (EMR) systems typically used within primary care. Key Features Compact, lightweight and portable Extended frequency range: 125 – 8000Hz Attenuation range: -10 – 100 dBHL Automatic threshold saving Single, pulsed, warble or continuous PC Software included Intuitive and ergonomic design Mains and optional battery power

GBP 1368.00
1

Amplivox - 116 Manual screening audiometer - optional audiocups and battery, Battery Function and Audiocups fitted

Amplivox - 116 Manual screening audiometer - optional audiocups and battery, Battery Function and Audiocups fitted

Product Properties Cost-effective and easy-to-use, the Model 116 is an essential tool for completing hearing tests within schools, primary care and GP surgeries. Ergonomic design Designed with the operator in mind, the Model 116 has a clear display panel and dedicated soft key layout, allowing total focus on the test subject and reducing the time it takes to complete hearing assessments.  Time saving The audiometer includes all test frequencies and attenuation ranges required to perform a wide range of pure tone audiometry, such as standard threshold or sweep testing for school screening. It offers pure, pulsed, warble and continuous tones which allow for the testing and identification of hearing issues in subjects with tinnitus, presbycusis and noise induced hearing loss (NIHL). Automatic threshold results saving significantly reduces operator test times and increases attention of the test subject for more accurate results.  Portability At only 720g (1.58lbs), the lightweight and robust design of the Model 116 is perfect for healthcare professionals who need to travel. It also comes supplied with a custom carry case and all standard accessories. The optional battery power function can be used in all test settings, offering additional flexibility Data management Test results can be manually recorded, printed via the optional portable printer and or transferred to PC applications such as Amplivox Amplisuite or Audibase to create both PDF or printed copy. This ensures results can be saved within third-party Electronic medical record (EMR) systems typically used within primary care. Key Features Compact, lightweight and portable Extended frequency range: 125 – 8000Hz Attenuation range: -10 – 100 dBHL Automatic threshold saving Single, pulsed, warble or continuous PC Software included Intuitive and ergonomic design Mains and optional battery power

GBP 1728.00
1

Amplivox - 116 Manual screening audiometer - optional audiocups and battery, Battery Function

Amplivox - 116 Manual screening audiometer - optional audiocups and battery, Battery Function

Product Properties Cost-effective and easy-to-use, the Model 116 is an essential tool for completing hearing tests within schools, primary care and GP surgeries. Ergonomic design Designed with the operator in mind, the Model 116 has a clear display panel and dedicated soft key layout, allowing total focus on the test subject and reducing the time it takes to complete hearing assessments.  Time saving The audiometer includes all test frequencies and attenuation ranges required to perform a wide range of pure tone audiometry, such as standard threshold or sweep testing for school screening. It offers pure, pulsed, warble and continuous tones which allow for the testing and identification of hearing issues in subjects with tinnitus, presbycusis and noise induced hearing loss (NIHL). Automatic threshold results saving significantly reduces operator test times and increases attention of the test subject for more accurate results.  Portability At only 720g (1.58lbs), the lightweight and robust design of the Model 116 is perfect for healthcare professionals who need to travel. It also comes supplied with a custom carry case and all standard accessories. The optional battery power function can be used in all test settings, offering additional flexibility Data management Test results can be manually recorded, printed via the optional portable printer and or transferred to PC applications such as Amplivox Amplisuite or Audibase to create both PDF or printed copy. This ensures results can be saved within third-party Electronic medical record (EMR) systems typically used within primary care. Key Features Compact, lightweight and portable Extended frequency range: 125 – 8000Hz Attenuation range: -10 – 100 dBHL Automatic threshold saving Single, pulsed, warble or continuous PC Software included Intuitive and ergonomic design Mains and optional battery power

GBP 1548.00
1

Amplivox - 116 Manual screening audiometer - optional audiocups and battery, Audiocups

Amplivox - 116 Manual screening audiometer - optional audiocups and battery, Audiocups

Product Properties Cost-effective and easy-to-use, the Model 116 is an essential tool for completing hearing tests within schools, primary care and GP surgeries. Ergonomic design Designed with the operator in mind, the Model 116 has a clear display panel and dedicated soft key layout, allowing total focus on the test subject and reducing the time it takes to complete hearing assessments.  Time saving The audiometer includes all test frequencies and attenuation ranges required to perform a wide range of pure tone audiometry, such as standard threshold or sweep testing for school screening. It offers pure, pulsed, warble and continuous tones which allow for the testing and identification of hearing issues in subjects with tinnitus, presbycusis and noise induced hearing loss (NIHL). Automatic threshold results saving significantly reduces operator test times and increases attention of the test subject for more accurate results.  Portability At only 720g (1.58lbs), the lightweight and robust design of the Model 116 is perfect for healthcare professionals who need to travel. It also comes supplied with a custom carry case and all standard accessories. The optional battery power function can be used in all test settings, offering additional flexibility Data management Test results can be manually recorded, printed via the optional portable printer and or transferred to PC applications such as Amplivox Amplisuite or Audibase to create both PDF or printed copy. This ensures results can be saved within third-party Electronic medical record (EMR) systems typically used within primary care. Key Features Compact, lightweight and portable Extended frequency range: 125 – 8000Hz Attenuation range: -10 – 100 dBHL Automatic threshold saving Single, pulsed, warble or continuous PC Software included Intuitive and ergonomic design Mains and optional battery power

GBP 1548.00
1

Amplivox - PC850U - PC-based automatic screening audiometer, Audiocups

Amplivox - PC850U - PC-based automatic screening audiometer, Audiocups

Product Properties The leading PC based audiometer that provides a customised and flexible solution for all screening audiometry requirements within occupational health and safety critical roles. Proven to provide a streamlined and efficient hearing conservation programme. Comprehensive testing The PC850 is a reliable choice for occupational health professionals who require a vast range of screening modes. It includes automatic (computer / Békésy) and manual operation options to measure and assess hearing thresholds in accordance with safety critical hearing standards. It also has configurable options so the test can be customised to the users’ specific requirements, ensuring accurate and efficient testing. Designed to connect directly to a PC or as a stand-alone manual audiometer. Test assessment and management The suppled Audibase PC software offers custom built educational tools with a predictive hearing level and hearing loss indicator, providing a clear explanation to test subjects, and enabling a greater level of assessment. All tests can be automatically categorised in accordance with HSE standards. Portability Compact and lightweight at only 710g (1.56lbs), the PC850 is completely portable, making it ideal for both clinic and mobile audiometry use. EMR connectivity Offering seamless PC connectivity, the PC850 includes our Audibase data management software, allowing all test results to be stored and available for future review in a single application. Extensive data and trend analysis provides business intelligence to support the delivery of a successful hearing conservation programme and identify at risk individuals. The PC850 can also be interfaced to a number of leading OH Electronic Medical Record (EMR) systems to provide a paperless and seamless health screening programme that maximises workflow efficiencies. Key features Automatic and manual test modes (inc. Békésy test) HSE categorisation Unique educational and assessment tools Extensive data analysis and trending Communication channel Third-party EMR connectivity Intuitive and ergonomic design Compact, lightweight and portable Included Standard audiometric headset Patient response switch Power supply with country adaptors Carry case USB stick (manuals and Audibase software) USB cable (PC connection)

GBP 4272.00
1

Amplivox - PC850U - PC-based automatic screening audiometer, Not required

Amplivox - PC850U - PC-based automatic screening audiometer, Not required

Product Properties The leading PC based audiometer that provides a customised and flexible solution for all screening audiometry requirements within occupational health and safety critical roles. Proven to provide a streamlined and efficient hearing conservation programme. Comprehensive testing The PC850 is a reliable choice for occupational health professionals who require a vast range of screening modes. It includes automatic (computer / Békésy) and manual operation options to measure and assess hearing thresholds in accordance with safety critical hearing standards. It also has configurable options so the test can be customised to the users’ specific requirements, ensuring accurate and efficient testing. Designed to connect directly to a PC or as a stand-alone manual audiometer. Test assessment and management The suppled Audibase PC software offers custom built educational tools with a predictive hearing level and hearing loss indicator, providing a clear explanation to test subjects, and enabling a greater level of assessment. All tests can be automatically categorised in accordance with HSE standards. Portability Compact and lightweight at only 710g (1.56lbs), the PC850 is completely portable, making it ideal for both clinic and mobile audiometry use. EMR connectivity Offering seamless PC connectivity, the PC850 includes our Audibase data management software, allowing all test results to be stored and available for future review in a single application. Extensive data and trend analysis provides business intelligence to support the delivery of a successful hearing conservation programme and identify at risk individuals. The PC850 can also be interfaced to a number of leading OH Electronic Medical Record (EMR) systems to provide a paperless and seamless health screening programme that maximises workflow efficiencies. Key features Automatic and manual test modes (inc. Békésy test) HSE categorisation Unique educational and assessment tools Extensive data analysis and trending Communication channel Third-party EMR connectivity Intuitive and ergonomic design Compact, lightweight and portable Included Standard audiometric headset Patient response switch Power supply with country adaptors Carry case USB stick (manuals and Audibase software) USB cable (PC connection)

GBP 4092.00
1

Amplivox - AUD06 Audibase 5.5

Amplivox - AUD06 Audibase 5.5

Product Properties An occupational health database application designed to interface to Amplivox screening audiometers to facilitate the storage, interpretation and analysis of air conduction (AC) screening results. The Audibase5 software program facilitates the electronic storage of audiometric test records on a PC. Audibase5 is designed to be intuitive and easy to use with standard windows icons used throughout. Records can be reviewed on screen, printed, exported to other PC applications, or transferred to an Amplivox CA850 audiometer for inclusion in future audiograms. Access to the audiogram records contained within Audibase5 is restricted to authorised personnel only. Audiograms are automatically categorised in accordance with HSE recommendations. The user definable recall function provides for an effective means of organising an annual audiogram test program. The implementation of pro-active hearing conservation programs is possible with extensive data analysis features. ”At risk” individuals and user defined reporting groups can be easily identified and monitored. Designed to link with designated Amplivox screening audiometers, Audibase provides a cost effective solution for the electronic storage, management and analysis of audiometric test results. Connectivity Audibase5.5 can interface with the following Amplivox audiometers Amplivox 116 manual screening audiometer Amplivox 170 automatic audiometer Amplivox CA850 series 5 automatic audiometer Amplivox PC850 PC based automatic audiometer Amplivox Otosure PC based automatic audiometer PC Requirements Computer: A Pentium processor or equivalent Memory: Internal memory and available disk space as required by the PC operating system Operating system: Stand-Alone PC with Windows 7 or higher Disc Drives: CD and a hard disc drive are required Printer: The printer designated by the operating system will be used as the default printer Software: The programme will be supplied on a CD A minimum screen resolution of 1024 x 768 is required Images for illustration purposes only, actual product may differ.

GBP 901.19
1

Amplivox - 170 - Manual and automatic screening audiometer, Not required

Amplivox - 170 - Manual and automatic screening audiometer, Not required

Product Properties Cost-effective and easy-to-use, the Model 170 is the preferred tool of choice for hearing care professionals who complete hearing tests within schools, primary care, GP surgeries and industry. Ergonomic design Designed with the operator in mind, the Model 170 has a clear display panel and dedicated soft key layout, allowing complete focus on the test subject and reducing the time it takes to do examinations. Time saving The audiometer includes test frequencies and attenuation ranges required to perform a wide range of pure tone audiometry, such as standard threshold or sweep testing for school screening. Automatic test routines with pure and pulsed test tones enable large-scale screening programmes to be delivered effectively. Portability At only 710g (1.52lbs), the lightweight and robust design of the Model 170 benefits any hearing care professional who frequently travels. This instrument is supplied with a custom carry case and all standard accessories. Data management Results can be manually recorded, printed with the optional portable printer, saved in internal memory and or transferred to a PC application, thus giving a comprehensive range of data management choices. The audiometer also offers integration to a number of third-party Electronic Medical Record (EMR) systems. This enables the seamless transfer of results and data, for improved workflow efficiency. For specific occupational health screening programmes, the Model 170 can also be supplied with the Amplivox Audibase data management software which will automatically categorise hearing tests. Key Features Manual and automatic screening Compact, lightweight and portable Extended frequency range: 125 – 8000Hz Attenuation range: -10 – 100 dBHL User defined test routines Automatic threshold saving PC Software included Intuitive and ergonomic design Included Standard audiometric headset Patient response switch Audiogram cards (50) Power supply with country adaptors Carry case USB stick (manuals and Amplisuite software)

GBP 2610.00
1