353 results (0,15052 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Apollo 29600-799 Talentum Test Torch

Apollo SA5100-710APO Soteria Multi-Sensor Detector Dual OpticalHeat

Apollo SA5100-760APO Soteria Multi-Sensor Detector OpticalHeat

Apollo Orbis I.S. Multi-sensor Detector ORB-OH-53027-APO

Apollo 58002-350APO Discovery Base Sounder Visual Indicator White Flash

Apollo 58002-351APO Discovery Base Sounder Visual Indicator Red Flash

Apollo Orbis TimeSaver Diode Base - ORB-DB-00003-APO

Apollo SA5500-351APO Open-Area Sounder VID Red Body Red Flash

Apollo SA5100-810APO Soteria Tri-Sensor Detector Dual OpticalHeatCO

Apollo Isolator XP95 and Discovery 55000-720APO

Apollo SA5500-350APO Open-Area Sounder VID Red Body White Flash

Apollo SA5501-350APO Open-Area Sounder VID White Body White Flash

Apollo SA5501-351APO Open-Area Sounder VID White Body Red Flash

Apollo XP95 Sounder VAD Base DIN-Tone with Isolator 45681-707APO

Apollo Universal Bracket for Beam Detector Heads and Prisms 29600-527

Apollo Orbis Marine TimeSaver Base ORB-MB-00001-MAR

Apollo Orbis Marine Relay Base ORB-RB-40004-MAR

Apollo XPander Optical Smoke Detector and Mounting Base XPA-CB-12034-APO

Apollo XPander Sounder Beacon and CS Heat Detector XPA-CB-14022-APO

Apollo XPander Sounder Beacon and CS Heat Detector XPA-CB-14022-APO

Apollo XPander Sounder Beacon and CS Heat DetectorXPA-CB-14022-APOXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves.The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface. The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.OperationXPander sounders can be wall or ceiling mounted and use a bi-directional monitored radio platform to communicate. They feature 32 selectable tones including the Apollo tone and a self test which causes a fault signal to be sent if the sounders fail to operate. The self-test feature is activated by a DIL Switch. Individual parts may be ordered separately.Key Featuresmodern stylingloop-powered interface operating on 868MHzwireless addresses seen by control panel as normal addressesradio base with wireless circuitry and battery compartmentchamber designed to inhibit dirt penetration and thus reduce false alarmsautomatic drift compensation with DirtAlert warningalgorithms for transient alarm rejectionFasTest reduces time taken to test detectorsremote test facility3-5 years battery life

GBP 372.43
1

Apollo XPander Sounder Beacon and A1R Heat Detector XPA-CB-14021-APO

Apollo XPander Sounder Beacon and A1R Heat Detector XPA-CB-14021-APO

Apollo XPander Sounder Beacon and A1R Heat DetectorXPA-CB-14021-APOXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves.The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface. The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.OperationXPander sounders can be wall or ceiling mounted and use a bi-directional monitored radio platform to communicate. They feature 32 selectable tones including the Apollo tone and a self test which causes a fault signal to be sent if the sounders fail to operate. The self-test feature is activated by a DIL Switch. Individual parts may be ordered separately.Key Featuresmodern stylingloop-powered interface operating on 868MHzwireless addresses seen by control panel as normal addressesradio base with wireless circuitry and battery compartmentchamber designed to inhibit dirt penetration and thus reduce false alarmsautomatic drift compensation with DirtAlert warningalgorithms for transient alarm rejectionFasTest reduces time taken to test detectorsremote test facility3-5 years battery life

GBP 372.43
1

Apollo XPander Sounder Beacon and Optical Smoke Detector XPA-CB-14020-APO

Apollo XPander Sounder Beacon and Optical Smoke Detector XPA-CB-14020-APO

Apollo XPander Sounder Beacon and Optical Smoke DetectorXPA-CB-14020-APOXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. The interface communicates with the detection and alarm signalling devices by means of radio waves. The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface.The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.OperationXPander sounders can be wall or ceiling mounted and use a bi-directional monitored radio platform to communicate. They feature 32 selectable tones including the Apollo tone and a self test which causes a fault signal to be sent if the sounders fail to operate. The self-test feature is activated by a DIL Switch. Individual parts may be ordered separately.Key Featuresmodern stylingloop-powered interface operating on 868MHzwireless addresses seen by control panel as normal addressesradio base with wireless circuitry and battery compartmentchamber designed to inhibit dirt penetration and thus reduce false alarmsautomatic drift compensation with DirtAlert warningalgorithms for transient alarm rejectionFasTest reduces time taken to test detectors remote test facility3-5 years battery life

GBP 370.69
1

Apollo XPander Multisensor Detector and Mounting Base XPA-CB-13032-APO

Apollo XPander A1R Heat Detector and Mounting Base - XPA-CB-11170-APO

Apollo XPander A1R Heat Detector and Mounting Base - XPA-CB-11170-APO

Apollo XPander A1R Heat Detector and Mounting Base - XPA-CB-11170-APOThere are two heat detectors in the XPander range designed to suit a wide variety of operating conditions. A static heat detector CS responds only when a fixed temperature has been reached and a Rate-of-Rise Detector A1R which has a fixed upper limit but in addition measures the rate of increase in temperature.Brand InformationXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves. The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface.The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.Key Features WirelessCan be used in applications where smoke detectors are unsuitableIdeal for environments that are dirty or smoky under natural conditionsCS detectors are ideal for use in the environments with rapid temperature fluctuations such as boiler roomsBi-directional monitored radio platformFiveyear battery life using standard AA alkaline batteries

GBP 188.28
1

Apollo XPander CS Heat Detector and Mounting Base - XPA-CB-11171-APO

Apollo XPander CS Heat Detector and Mounting Base - XPA-CB-11171-APO

Apollo XPander CS Heat Detector and Mounting Base - XPA-CB-11171-APOThere are two heat detectors in the XPander range designed to suit a wide variety of operating conditions. A static heat detector CS responds only when a fixed temperature has been reached and a Rate-of-Rise Detector A1R which has a fixed upper limit but in addition measures the rate of increase in temperature.Brand InformationXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves. The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface.The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.Key Features WirelessCan be used in applications where smoke detectors are unsuitableIdeal for environments that are dirty or smoky under natural conditionsCS detectors are ideal for use in the environments with rapid temperature fluctuations such as boiler roomsBi-directional monitored radio platformFiveyear battery life using standard AA alkaline batteries

GBP 187.36
1