27 results (0,13838 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Apollo Discovery Multisensor Detector 58000-700APO

Apollo Discovery Multisensor Detector 58000-700APO

Apollo Discovery Multisensor Detector 58000-700APOThe Discovery Multisensor Detector consists of optical smoke and thermistor temperature sensors which give both a combined signal as well as a separate heat signal for improved false alarm management. The Discovery Multisensor construction is similar to that of the optical detector but uses a different lid and optical mouldings to accommodate the thermistor heat sensor.The Discovery OpticalHeat Multisensor Detector contains an optical smoke sensor and a thermistor temperature sensor whose outputs are combined to give the final analogue value. The way in which the signals from the two sensors are combined depends on the response mode selected. The five modes provide response behaviour which incorporates pure heat detection pure smoke detection and a combination of both.The multisensor is therefore useful over the widest range of applications. The signals from the optical smoke sensing element and the temperature sensor are independent and represent the smoke level and the air temperature respectively in the vicinity of the detector. The detectors micro-controller processes the two signals according to the mode selected.When the detector is operating as a multisensor i.e. modes 1 3 and 4 the temperature signal processing extracts only rate-of-rise information for combination with the optical signal. In these modes the detector will not respond to a slow temperature increase even if the temperature reaches a high level. A large sudden change in temperature can however cause an alarm without the presence of smoke if sustained for 20 seconds.Response ModesMode 1 has very high smoke sensitivity combined with high heat sensitivity. This gives a high overall sensitivity to both smouldering and flaming fires.Mode 2 has a smoke sensitivity similar to that of a normal optical smoke detector. This mode is therefore equivalent to a standard optical detector. It is suitable for applications in which wide temperature changes occur under normal conditions.Mode 3 has moderate smoke sensitivity combined with a moderate sensitivity to heat. This combination is considered the optimum for most general applications since it offers good response to both flaming and smouldering fires.Mode 4 has lower than normal smoke sensitivity combined with high heat sensitivity. This makes it suitable for applications in which a certain amount of fumes or smoke is considered normal.Mode 5 has no smoke sensitivity at all but gives a pure heat detector response meeting the response time requirements for a Class A1R detector in the European Standard EN 54- 5. In this mode the detector will respond to slowly changing temperatures and has a fixed temperature alarm threshold at 58OC. The analogue value in this mode will give the approximate air temperature over the range 15OC to 55C. In Mode 5 the smoke sensor is still active though it does not contribute to the analogue signal. As a consequence if the detector is used in a dirty or smoky environment the optical sensor drift flag may be activated in the heat only mode.Key FeaturesIdeal for a wide range of applicationsEnhanced false alarm managementRecommended in specific modes for hotel bedrooms and hospital wardsUnaffected by wind or atmospheric pressureWell-suited to sensitive environmentsFive EN 54 approved response modesHeat only and optical only optionsRemote test feature

GBP 50.32
1

Apollo XPander Multisensor Detector and Mounting Base XPA-CB-13032-APO

Apollo Conventional Dual IR Flame Detector 55000-060APO

Apollo Conventional Triple IR Flame Detector 55000-019APO

Apollo Conventional UV Dual IR Flame Detector 55000-064APO

Apollo Orbis I.S. Multi-sensor Detector ORB-OH-53027-APO

Apollo Wall Loop Powered VAD White Body White Flash 55000-744APO

Apollo Ceiling Loop Powered VAD White Body White Flash 55000-745APO

Apollo Ceiling Loop Powered VAD Red Body White Flash

Apollo Wall Loop Powered VAD Red Body White Flash 55000-741APO

Apollo Orbis Intrinsically Safe Optical Smoke Detector with Flashing LED ORB-OP-52028-APO

GBP 83.96
1

Apollo Orbis I.S. Optical Smoke Detector ORB-OP-52027-APO

Apollo XP95 Heat Detector High Temperature 55000-401APO

Apollo XP95 Heat Detector High Temperature 55000-401APO

Apollo XP95 Heat Detector High Temperature 55000-401APOThe XP95 Heat Detector monitors temperature by using a single thermistor which provides a count output proportional to the external air temperature. The XP95 range features two heat detectors standard and high temperature. The standard heat detector is classified as an A2S device and will report an alarm at 55C. The high temperature detector classified as a CS device will report an alarm at 90C.OperationThe XP95 heat detectors have a low air flow resistance case made of self-extinguishing white polycarbonate. The devices monitor heat by using a single thermistor network which provides a voltage output proportional to the external air temperature. The standard heat detectors 55000-400 and 55000-420 respond to increasing air temperature in such a way that they are classified as an A2S device. Both devices will give 55 counts at 55C. A high temperature CS heat detector 55000-401 which can be installed in a typical ambient temperature of 55C is available. This device will give 55 counts at 90C.ApplicationThe choice of detector from the XP95 range follows the well-established principles of system design. That is the optimum detector type will depend on the type of fire risk and fire load and the type of environment in which the detector is sited. For general use smoke detectors are recommended since these give the highest level of protection. Smoke detectors from the XP95 range may be optical or multisensor types. It is generally accepted that ionisation types have a high sensitivity to flaming fires whereas optical detectors have high sensitivity to smouldering fires.Key FeaturesIdeal in environments that are dirty or smoky under natural conditionsWell suited for warehouses loading bays and car-parksUnaffected by wind or atmospheric pressure

GBP 32.66
1

Apollo Exd Conventional Dual IR Flame Detector 55000-061APO

Apollo Exd Conventional UV Dual IR Flame Detector 55000-065APO

Apollo Exd Conventional Triple IR Flame Detector 55000-062APO

Apollo I.S. Conventional Triple IR Flame Detector 55000-063APO

Apollo Orbis I.S Multisensor with Flashing LED ORB-OH-53028-APO

Apollo Orbis Optical Smoke Detector with Flashing LED ORB-OP-12003-APO

Apollo Orbis Optical Smoke Detector with Flashing LED ORB-OP-12003-APO

Apollo Orbis Optical Smoke Detector with Flashing LED ORB-OP-12003-APO OperationApollos Orbis operates on the well-established light scatter principle. The remarkable optical design of the Orbis optical smoke detector allows it to respond to a wide spectrum of fires. The sensing chamber of the Orbis optical smoke detector contains an optical sensor which measures back-scattered light as well as the more usual forward-scattered light. Sensitivity to black smoke is greatly improved.The detector is calibrated so that Orbis is highly reliable in detecting fires but is much less likely to generate false alarms than earlier smoke detectors. The stability of the detectorhigh reliability low false alarm rateis further increased by the use of algorithms to decide when the detector should change to the alarm state. This removes the likelihood of a detector producing an alarm as a result of smoke from smoking materials or from another non-fire source.Brand FeaturesTimeSaver Base designed for fast installationStartUp for fast commissioningFasTest reduces maintenance timeautomatic drift compensation with DirtAlert warning to easily identify dirty detectorsSensAlert which indicates that the detector is not operating properlywide voltage and operating temperature rangesoptical sensor designed for high reliability and reduced false alarm incidencemultisensory smoke detector for detecting fast-burning firesflashing LED option

GBP 17.24
1

Apollo Orbis Non-Latching Optical Smoke Detector ORB-OP-02032-APO

Apollo XP95 Multisensor Detector 55000-885APO

Apollo XP95 Multisensor Detector 55000-885APO

Apollo XP95 Multisensor Detector 55000-885APOThe XP95 multisensor Detector contains an optical smoke sensor and a thermistor temperature sensor whose outputs are combined to give the final analogue value.The multisensor construction is similar to that of the optical detector but uses a different lid and optical mouldings to accommodate the thermistor temperature sensor. The sectional view shows the arrangement of the optical chamber and thermistor.The signals from the optical smoke sensing element and the temperature sensor are independent and represent the smoke level and the air temperature respectively in the vicinity of the detector.The detectors microcontroller processes the two signals.The temperature signal processing extracts only rate of rise information for combination with the optical signal. The detector will not respond to a slow temperature increase - even if the temperature reaches a high level. A large sudden change in temperature can however cause an alarm without the presence of smoke if sustained for 20 seconds.The processing algorithms in the multisensor incorporate drift compensation. The control panel must not have a drift compensation algorithm enabled. The sensitivity of the detector is considered the optimum for most general applications since it offers good response to both smouldering and flaming fires.Key FeaturesSensitive to a wide range of firesWell suited for environments such as hotel bedroomsUnaffected by wind or atmospheric pressureOther part codes include AD-2004

GBP 39.53
1

Apollo Orbis Multi-sensor Detector with Flashing LED ORB-OH-13003-APO

Apollo Orbis Multi-sensor Detector with Flashing LED ORB-OH-13003-APO

Apollo Orbis Multi-sensor Detector with Flashing LED ORB-OH-13003-APOOrbis multi-sensor smoke detectors are recognized as good detectors for general use but are additionally more sensitive to fast burning flaming firesincluding liquid firesthan optical detectors. They can be readily used instead of optical smoke detectors but should be used as the detector of choice for areas where the fire risk is likely to include heat at an early stage in the development of the fire.As with Orbis optical smoke detectors the increased reliability of detection is combined with high immunity to false alarms.OperationThe multi-sensor smoke detector has two sensors one for smoke one for heat and the alarm decision is derived from either sensor or a combination of both. The multi-sensor is a development of the Orbis optical detector described in the previous chapter and goes further in its capabilities of fire detection.The optical sensor is identical to the one in the Orbis optical detector. Its sensitivity is however influenced by a heat sensing element which makes the detector more responsive to fast-burning flaming fires.Key FeaturesResponds well to fast-burning flaming firesTransient rejection algorithms reduce false alarmsAutomatic drift compensation with DirtAlert a yellow flashing LED to easily identify dirty detectorsRed flashing LED at StartUp confirms that the device is operating. SensAlert yellow flashing LED indicates faulty operationFasTest takes just 4 seconds to test and confirm detectors are functioning correctlyDustDefy system prevents dust ingress while maintaining airflow

GBP 23.71
1

Apollo Orbis Marine Multi-Sensor Detector with Flashing LED ORB-OH-43003-MAR

Apollo Orbis Marine Multi-Sensor Detector with Flashing LED ORB-OH-43003-MAR

Apollo Orbis Marine Multi-Sensor Detector with Flashing LED ORB-OH-43003-MARThe Orbis Marine Multisensor Detector benefits from the same false alarm reduction technology as the optical detector with the addition of a heat sensing element.OperationMultisensor Smoke Detectors are recognized as good detectors for general use but are additionally more sensitive to fast burning flaming fires including liquid fires than optical detectors. They can be readily used instead of optical smoke detectors but should be used as the detector of choice for areas where the fire risk is likely to include heat at an early stage in the development of the fire. As with Orbis Marine optical smoke detectors the increased reliability of detection is combined with high immunity to false alarms.The Obis Marine multisensor smoke detector has two sensors one for smoke one for heat and the alarm decision is derived from either sensor or a combination of both. The multisensor is a development of the Orbis Marine optical detector described in the previous chapter and goes further in its capabilities of fire detection. The optical sensor is identical to the one in the Orbis optical detector. Its sensitivity is however influenced by a heat sensing element which makes the detector more responsive to fast-burning flaming fires.Key FeaturesResponds well to fast burning flaming firesReduced false alarms Increased reliability of detectionSensing chamber keeps out dust and other airborne contaminantsOperates over a broad range of voltages at extremes of temperatureFlashing LED option

GBP 34.07
1

Apollo Orbis Marine Multisensor Detector ORB-OH-43001-MAR

Apollo Orbis Marine Multisensor Detector ORB-OH-43001-MAR

Apollo Orbis Marine Multisensor Detector ORB-OH-43001-MARThe Orbis Marine Multisensor Detector benefits from the same false alarm reduction technology as the optical detector with the addition of a heat sensing element.OperationMulti-sensor Smoke Detectors are recognized as good detectors for general use but are additionally more sensitive to fast burning flaming fires including liquid fires than optical detectors.They can be readily used instead of optical smoke detectors but should be used as the detector of choice for areas where the fire risk is likely to include heat at an early stage in the development of the fire. As with Orbis Marine optical smoke detectors the increased reliability of detection is combined with high immunity to false alarms.The Obis Marine multi-sensor smoke detector has two sensors one for smoke one for heat and the alarm decision is derived from either sensor or a combination of both. The multi-sensor is a development of the Orbis Marine optical detector described in the previous chapter and goes further in its capabilities of fire detection.The optical sensor is identical to the one in the Orbis optical detector. Its sensitivity is however influenced by a heat sensing element which makes the detector more responsive to fast-burning flaming fires.Key FeaturesResponds well to fast burning flaming firesReduced false alarmsIncreased reliability of detectionSensing chamber keeps out dust and other airborne contaminantsOperates over a broad range of voltages at extremes of temperature

GBP 34.07
1

Apollo Discovery Carbon Monoxide CO Detector 58000-300APO

Apollo Discovery Carbon Monoxide CO Detector 58000-300APO

Apollo Discovery Carbon Monoxide CO Detector 58000-300APODiscovery CO fire detectors contain a long-life electro-chemical carbon monoxide sensor which is tolerant of low levels of common vapours and household products. The sensing technology is fast accurate and needs only very low power. The detection capabilities are enhanced by a rate-sensitive response. Fast rises in the carbon monoxide level are often associated with hot fires and the detector will respond earlier under these conditions. The analogue reply from the detector is rate limited to remove nuisance alarms resulting from short-term high levels caused by sources such as pipe smokers or gas flame ignition.Brand InformationDiscovery is a range of high-specification analogue addressable fire detectors and alarm devices. Discovery detectors offer effective false alarm management by a combination of EN 54 approved operating modes and sophisticated algorithms. Drift compensation further reduces the likelihood of false alarms caused by a build-up of dust in the sensing chamber. In addition to the familiar smoke and heat detectors the Discovery range features two multisensor detectors. One is an opticalheat multisensor which can be used to protect against many types of fire risk. The other is a carbon monoxideheat multisensor which protects against both smouldering fires and those generating heat.OperationThe Discovery CO detector has five operating modes each having a set combination of sensitivity and response delay which the user can select for any given application.ApplicationCO detectors do not detect smoke particles or heat and are not universal replacements for smoke detectors. Apollo does not endorse the use of CO detectors as the main method of fire detection if the protected area is an escape route there is a requirement to detect overheating of electrical equipment or cables the protected area is exposed to sources of CO such as vehicle exhausts or to hydrogen or to high levels of alcohol vapour as emitted by some cleaning agents there is a requirement to detect fires involving flammable liquids CO fire detectors are particularly suitable for supplementing smoke detection when there is a deep seated smouldering fire risk a risk of fire starting in an enclosed space a likelihood of stratification taking place Carbon monoxide detectors may be used as the primary fire detector in areas where the following conditions exist the main risk is smouldering fires optical smoke detectors are deemed unsuitable see FALSE ALARMS below the fire compartment is not greater than 50m2 Typical applications include hotel bedrooms halls of residence sheltered accommodation and hospital wards.CommunicationDiscovery uses a digital communications protocol which has been developed from the XP95 protocol but differs in that it allows communication in three different modes Normal Read and Write to allow a more extensive exchange of information and commands than previous analogue addressable ranges. In addition Discovery can store data in non-volatile memory. The Normal mode is identical to the XP95 protocol with the exception that the five additional analogue value bits in the XP95 protocol extension have been re-defined so that the fire control panel is able to distinguish between Discovery and XP95 devices. The Read mode is used to check information stored in the non-volatile memory of each detector. It is accessed by using a simple extension to the Normal mode communication method from the fire control panel to the detector. In Write mode the fire control panel is able to write information to the detector by extending the communication method in the same way as in Read mode. During Read or Write modes a detector can signal an alarm by means of the alarm flag and alarm address bits. Discovery detectors are compatible with XP95 and Soteria. It should be noted however that Discovery features will not be available when Discovery is used with XP95 fire control panels. Fire control panels with drift compensation algorithms should disable the algorithms when communicating with Discovery. For fire control panels running CoreProtocol please refer to the fire control panel manufacturers operating instructions.

GBP 62.71
1