15 results (0,13408 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Apollo XPander Sounder Beacon and Optical Smoke Detector XPA-CB-14020-APO

Apollo XPander Sounder Beacon and Optical Smoke Detector XPA-CB-14020-APO

Apollo XPander Sounder Beacon and Optical Smoke DetectorXPA-CB-14020-APOXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. The interface communicates with the detection and alarm signalling devices by means of radio waves. The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface.The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.OperationXPander sounders can be wall or ceiling mounted and use a bi-directional monitored radio platform to communicate. They feature 32 selectable tones including the Apollo tone and a self test which causes a fault signal to be sent if the sounders fail to operate. The self-test feature is activated by a DIL Switch. Individual parts may be ordered separately.Key Featuresmodern stylingloop-powered interface operating on 868MHzwireless addresses seen by control panel as normal addressesradio base with wireless circuitry and battery compartmentchamber designed to inhibit dirt penetration and thus reduce false alarmsautomatic drift compensation with DirtAlert warningalgorithms for transient alarm rejectionFasTest reduces time taken to test detectors remote test facility3-5 years battery life

GBP 370.69
1

Apollo XPander Sounder Beacon and CS Heat Detector XPA-CB-14022-APO

Apollo XPander Sounder Beacon and CS Heat Detector XPA-CB-14022-APO

Apollo XPander Sounder Beacon and CS Heat DetectorXPA-CB-14022-APOXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves.The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface. The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.OperationXPander sounders can be wall or ceiling mounted and use a bi-directional monitored radio platform to communicate. They feature 32 selectable tones including the Apollo tone and a self test which causes a fault signal to be sent if the sounders fail to operate. The self-test feature is activated by a DIL Switch. Individual parts may be ordered separately.Key Featuresmodern stylingloop-powered interface operating on 868MHzwireless addresses seen by control panel as normal addressesradio base with wireless circuitry and battery compartmentchamber designed to inhibit dirt penetration and thus reduce false alarmsautomatic drift compensation with DirtAlert warningalgorithms for transient alarm rejectionFasTest reduces time taken to test detectorsremote test facility3-5 years battery life

GBP 372.43
1

Apollo XPander Sounder Beacon and A1R Heat Detector XPA-CB-14021-APO

Apollo XPander Sounder Beacon and A1R Heat Detector XPA-CB-14021-APO

Apollo XPander Sounder Beacon and A1R Heat DetectorXPA-CB-14021-APOXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves.The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface. The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.OperationXPander sounders can be wall or ceiling mounted and use a bi-directional monitored radio platform to communicate. They feature 32 selectable tones including the Apollo tone and a self test which causes a fault signal to be sent if the sounders fail to operate. The self-test feature is activated by a DIL Switch. Individual parts may be ordered separately.Key Featuresmodern stylingloop-powered interface operating on 868MHzwireless addresses seen by control panel as normal addressesradio base with wireless circuitry and battery compartmentchamber designed to inhibit dirt penetration and thus reduce false alarmsautomatic drift compensation with DirtAlert warningalgorithms for transient alarm rejectionFasTest reduces time taken to test detectorsremote test facility3-5 years battery life

GBP 372.43
1

Apollo XPander White Sounder with Mounting Base XPA-CB-14002-APO

Apollo XPander White Sounder with Mounting Base XPA-CB-14002-APO

Apollo XPander White Sounder with Mounting Base XPA-CB-14002-APOThe XPander Sounder and Sounder Base is wireless and designed to be used with XPander detectors and manual call points.Brand InformationXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves. The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface.The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.OperationXPander sounders can be wall or ceiling mounted and use a bi-directional monitored radio platform to communicate. They feature 32 selectable tones including the Apollo tone and a self test which causes a fault signal to be sent if the sounders fail to operate. The self-test feature is activated by a DIL Switch. Individual parts may be ordered separately.Key Featuresmodern stylingloop-powered interface operating on 868MHzwireless addresses seen by control panel as normal addressesradio base with wireless circuitry and battery compartmentchamber designed to inhibit dirt penetration and thus reduce false alarmsautomatic drift compensation with DirtAlert warningalgorithms for transient alarm rejectionFasTest reduces time taken to test detectorsremote test facility3-5 years battery life

GBP 240.92
1

Apollo XPander Sounder Visual Indicator Clear and Optical Smoke Detector XPA-CB-14024-APO

Apollo XPander Sounder Visual Indicator Clear and Optical Smoke Detector XPA-CB-14024-APO

Apollo XPander Sounder Visual Indicator Clear and Optical Smoke Detector XPA-CB-14024-APOThe XPander Sounder and Sounder Base is wireless and designed to be used with XPander detectors and manual call points.OperationXPander sounders can be wall or ceiling mounted and use a bi-directional monitored radio platform to communicate. They feature 32 selectable tones including the Apollo tone and a self-test which causes a fault signal to be sent if the sounders fail to operate. The self-test feature is activated by a DIL Switch.Brand InformationXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves.The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface. The detectors incorporate drift compensation and report any compensation limit occurring.The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.Key FeaturesWirelessBi-directional monitored radio platformChoice of 32 selectable tonesAudible self-test availableOutput is between 92 and 106dbA at 1m dependent on tone setting

GBP 372.43
1

Apollo XPander Red Sounder with Mounting Base - XPA-CB-14001-APO

Apollo XPander Red Sounder with Mounting Base - XPA-CB-14001-APO

Apollo XPander Red Sounder with Mounting Base - XPA-CB-14001-APOThe XPander Sounder and Sounder Base is a wireless and designed to be used with XPander detectors and manual call points.Brand InformationXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves. The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface.The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.OperationXPander sounders can be wall or ceiling mounted and use a bi-directional monitored radio platform to communicate. They feature 32 selectable tones including the Apollo tone and a self test which causes a fault signal to be sent if the sounders fail to operate. The self-test feature is activated by a DIL Switch. Individual parts may be ordered separately.Key Features WirelessBi-directional monitored radio platformChoice of 32 selectable tonesAudible self-test availableOutput is between 92 and 106dBA at 1m - dependent on tone setting

GBP 237.64
1

Apollo Weatherproof Manual Call Point with Isolator Red 58100-951APO

Apollo XP95 I.S. Intrinsically Safe Manual Call Point - 55200-940APO

Apollo XP95 I.S. Intrinsically Safe Manual Call Point - 55200-940APO

Apollo XP95 I.S. Intrinsically Safe Manual Call Point - 55200-940APOThe XP95 I.S. Manual Call Point has been designed to operate on a loop of intelligent fire detection devices and when activated interrupts the polling cycle for a very fast response. When activated the intrinsically safe call point not only interrupts the polling cycle to indicate to the control panel that it has been operated but also reports its address. Thus an alarm and its location can be reported in less than 0.2 seconds. Full details of the principles of operation and the electrical description are published in the XP95 Engineering Product Guide.XP95 I.S. manual call points have the same operating characteristics as the standard versions. They are available in two types of housing and in a number of versions. Designed specifically for use in atmospheres in which explosive mixtures are or may be present certain design considerations must be observed. The standard red I.S. manual call point is EN54-112001 compliant and has a resettable element. The range uses an IP67 weatherproof polycarbonate housing and is available in colours other than red.OperationThe address of each call point is set at the commissioning stage by means of a seven-segment DIL switch. A red alarm LED is provided on the call point. This LED is controlled independently of the call point by the control panel. This Manual Call Point helps reduce installation time as all the initial installation cabling is wired to a terminal block which fits neatly in the back of the Call Point. Once activated the XP95 IS Manual Call Point can be reset by inserting the test key into the bottom of the unit until the key clicks into position. Remove the test key and push the front cover up until it clicks homeKey FeaturesPlug and Play terminal connections for fast wiringContinuity link for wiring test before commissioningReports an alarm in under 0.2 secondsResettable element

GBP 183.65
1

Apollo XPander Amber Beacon with White Mounting Base - XPA-CB-14004-APO

Apollo XPander Amber Beacon with White Mounting Base - XPA-CB-14004-APO

Apollo XPander Amber Beacon with White Mounting Base - XPA-CB-14004-APOThe XPander Sounder and Sounder Base is wireless and designed to be used with XPander detectors and manual call points.Brand InformationXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves. The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface.The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.Key Featuresmodern stylingloop-powered interface operating on 868MHzwireless addresses seen by control panel as normal addressesradio base with wireless circuitry and battery compartmentchamber designed to inhibit dirt penetration and thus reduce false alarmsautomatic drift compensation with DirtAlert warningalgorithms for transient alarm rejectionFasTest reduces time taken to test detectorsremote test facility3-5 years battery life

GBP 321.25
1

Apollo XP95 I.S. Manual Call Point - 55100-940APO

Apollo XP95 I.S. Manual Call Point - 55100-940APO

Apollo XP95 I.S. Manual Call Point - 55100-940APOThe XP95 IS Manual Call Point has been designed to operate on a loop of intelligent fire detection devices and when activated interrupts the polling cycle for a very fast response the intrinsically safe call point not only interrupts the polling cycle to indicate to the control panel that it has been operated but also reports its address and therefore an alarm and its location can be reported in less than 0.2 seconds.The XP95 IS manual call points have the same operating characteristics as the standard versions. They are available in two types of housing and in a number of versions. Designed specifically for use in atmospheres in which explosive mixtures are or may be present certain design considerations must be observed. The standard red IS manual call point is EN54-112001 compliant and has a resettable element. The range uses an IP67 weatherproof polycarbonate housing and is available in colours other than red.Key FeaturesReports an alarm in under 0.2 secondsWaterproof weatherproofIP67Designed for explosive mixture atmosphereOperationThe address of each call point is set at the commissioning stage by means of a seven-segment DIL switch. A red alarm LED is provided on the call point. This LED is controlled independently of the call point by the control panel.This Manual Call Point helps reduce installation time as all the initial installation cabling is wired to a terminal block which fits neatly in the back of the Call Point. Once activated the XP95 IS Manual Call Point can be reset by inserting the test key into the bottom of the unit until the key clicks into position. Remove the test key and push the front cover up until it clicks home

GBP 234.79
1

Apollo XPA-CB-14027-APO XPander Multisensor Detector with Sounder VID Base White Flash

Apollo Discovery Marine Waterproof Manual Call Point with Isolator 58100-976MAR

Apollo XPA-CB-14023-APO XPander Multisensor Detector with Sounder VID Base Red Flash

Apollo XPA-CB-14019-APO XPander Multisensor Detector with Sounder Base

Apollo XPander Red Beacon with Red Mounting Base - XPA-CB-14003-APO