13 results (0,12445 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Baldwin Boxall VIGIL Eclipse4 Voice Alarm Public Address System BVECASE4

Baldwin Boxall VIGIL Eclipse4 Voice Alarm Public Address System BVECASE4

Baldwin Boxall VIGIL Eclipse4 Voice Alarm Public Address System BVECASE4The VIGIL Eclipse4 is a stand-alone EN54 certified voice alarmpublic address system. It is a complete fully monitored system which takes up less floor space and is ideal for fitting into building risers or places where space is restricted.VIGIL Eclipse4 is the next generation product in this range. It uses the new VIGIL3 transformerless amplifiers and the new VIGIL3 battery charger with VIGIL2 EVAS routeing technology.What are the benefits of the Eclipse SystemQuite simply the Eclipse is a fully integrated voice alarm system which takes up minimal floor space and is secured by bolting to a wall or other suitable solid upright structure. It is ideal for fitting within building risers and is easily networked to form a comprehensive voice alarm or public-address system.The modular nature of the system provides adaptability and is suitable for many types of building. In addition to its usefulness for high-rise style structures the Eclipse also fits well as a tenant system for landlordtenant voice alarm system solutions.Key FeaturesStand-alone system with an IP30 rated housing complete with integral battery backup For some systems a bolt on battery enclosure is required to house additional batteries.The unit includes a BVRD2M4 DSP-controlled VIGIL2 EVAS router and has space for up to four VIGIL3 amplifiers.Up to six flash stored 57 second messages with independent level surveillance and timing.Ideal for decentralised networking or tenant systems.Battery charger amplifiers batteries and BEL1 end-of-line modules to be ordered separately as required.Up to 126 units can be networked.Requires a direct non-switchable power supply - preferably via a Class D circuit breaker.Space for up to four VIGIL3 amplifiers purchased separatelyDimensions mm 500w x 900h x 200dKit ContainsEclipse4 caseBVRD2M4 DSP controlled routerBVMBC VIGIL3 mains battery chargerWiring loomand four messages evac alert start of test end of test from Baldwin Boxalls standard list.

GBP 4399.92
1

Baldwin Boxall 3-part White Disabled Toilet Alarm Kit DTAKIT

Baldwin Boxall 3-part Stainless Steel Disabled Toilet Alarm Kit DTASKIT

Baldwin Boxall Disabled Toilet Alarm Assistance Call Kit BVOCDTA

Baldwin Boxall Disabled Toilet Alarm Assistance Call Kit BVOCDTA

Baldwin Boxall Disabled Toilet Alarm Assistance Call Kit BVOCDTAThe BS83002009 standard requires that all new disabled WC installations are fitted with an emergency assistance alarm. This Disabled WC Alarm Kit provides a compliant reliable and easy to use disabled persons toilet alarm which contains a controller ceiling pull switch reset point overdoor light.The Controller should be located so that it is easily seen heard by people able to give assistance indicates where help is required. The unit is not suitable for exterior location unless suitably protected against water ingress.The Ceiling Pull Switch must be located so that it can be operated from the WC and from an adjacent floor area. The Ceiling Pull Switch is supplied with two G pulls one should be set a height between 800 1000mm the other set 100mm above the floor level.The Overdoor Light Sounder should be located so that it is easily seen and heard by people able to give assistance and indicates where help is required. Normally above the door outside the WC.The Reset Point should be located inside the WC area so that it is reachable from both a wheelchair and the WC.Key FeaturesIntegral mains powered PSU.Relay Output option.BS83002009 Acknowledge Feature.Includes Backup Battery.Powerful LEDs Sounder.Supply Healthy LED.Reset Button EnableDisable.Self-Test Facility.Twin G-Pulls LED.Reset Point with Re-Assurance LED.Overdoor Light with Sounder.White Material Finish.

GBP 275.78
1

Baldwin Boxall Disabled Toilet Alarm Assistance Call Kit Full Stainless-Steel BVOCDTAS2

Baldwin Boxall Disabled Toilet Alarm Assistance Call Kit Full Stainless-Steel BVOCDTAS2

Baldwin Boxall Disabled Toilet Alarm Assistance Call Kit Full Stainless-Steel BVOCDTAS2The BS83002009 standard requires that all new disabled WC installations are fitted with an emergency assistance alarm. This Disabled WC Alarm Kit provides a compliant reliable and easy to use disabled persons toilet alarm which contains a controller ceiling pull switch reset point overdoor light.The Controller should be located so that it is easily seen heard by people able to give assistance indicates where help is required. The unit is not suitable for exterior location unless suitably protected against water ingress.The Ceiling Pull Switch must be located so that it can be operated from the WC and from an adjacent floor area. The Ceiling Pull Switch is supplied with two G pulls one should be set a height between 800 1000mm the other set 100mm above the floor level.The Overdoor Light Sounder should be located so that it is easily seen and heard by people able to give assistance and indicates where help is required. Normally above the door outside the WC.The Reset Point should be located inside the WC area so that it is reachable from both a wheelchair and the WC.Key FeaturesIntegral mains powered PSU.Relay Output option.BS83002009 Acknowledge Feature.Includes Backup Battery.Powerful LEDs Sounder.Supply Healthy LED.Reset Button EnableDisable.Self-Test Facility.Twin G-Pulls LED.Reset Point with Re-Assurance LED.Overdoor Light with Sounder.All components have a stainless-steel finish

GBP 701.27
1

Baldwin Boxall Line Vox Unit BT10

Baldwin Boxall BVOCODL BVOCDTA Kit SpareOver-Door Light

Baldwin Boxall BVOCODL BVOCDTA Kit SpareOver-Door Light

Baldwin Boxall BVOCODL BVOCDTA Kit SpareOver-Door LightBaldwin Boxall OmniCare CARE2 Disabled Toilet Alarm Assistance Call Kit WhiteThe BS83002009 standard requires that all new disabled WC installations are fitted with an emergency assistance alarm. This Disabled WC Alarm Kit provides a compliant reliable and easy to use disabled persons toilet alarm which contains a controller ceiling pull switch reset point overdoor light.The Controller should be located so that it is easily seen heard by people able to give assistance indicates where help is required. The unit is not suitable for exterior location unless suitably protected against water ingress.The Ceiling Pull Switch must be located so that it can be operated from the WC and from an adjacent floor area. The Ceiling Pull Switch is supplied with two G pulls one should be set a height between 800 1000mm the other set 100mm above the floor level.The Overdoor Light Sounder should be located so that it is easily seen and heard by people able to give assistance and indicates where help is required. Normally above the door outside the WC. The Reset Point should be located inside the WC area so that it is reachable from both a wheelchair and the WC.Kit contains combined power supply and controller with reset button and high visibility LED ceiling mounted G pull cord with LED reset button and LED to reset calls locally overdoor triangular lens lightsounderKey FeaturesIntegral mains powered PSURelay Output optionBS83002009 Acknowledge FeatureIncludes Backup BatteryPowerful LEDs SounderSupply Healthy LEDReset Button EnableDisableSelf-Test FacilityTwin G-Pulls LEDReset Point with Re-Assurance LEDOverdoor Light with SounderWhite Material FinishDisabled Toilet Alarm Assistance Call KitWhiteFully compliant to BS83002009

GBP 65.32
1

Baldwin Boxall BVOCTSC64 OmnicarePLUS Local Control Panel 64-Way

Baldwin Boxall BVOCTSC64 OmnicarePLUS Local Control Panel 64-Way

Baldwin Boxall BVOCTSC64 OmnicarePLUS Local Control Panel 64-WayOmnicarePLUS makes it possible for very large disabled refuge fire telephone EVC systems to be installed.Up until now it has not been possible to install super large EVC systems. However this has all changed you can now have as many as 8064 outstations on a single system We agree that it is extremely unlikely that a system of this size would be required but what it means is that the restrictions have now been liftedOverall site-wide system master control is carried out by the use of a graphic layout on a touch screen PC. The graphic on the screen is multi-layer providing the user with an easy-to-use and instantly recognisable interface for the system.OmnicarePLUS is not limited to a single touch screen control point additional ones can be added to the system enabling placement in alternative control or security rooms. These will be slavesmimic panels unless full control is transferred to the panel due to compromise of the master control point or if required by the users.For local area control i.e. control of the outstations on a single floorareabuilding block specially designed Omnicare panels are employed. Up to 64 outstations can be connected to a local area control panel. Each local area control panel is able to communicate with the outstations connected to that unit.A standard Omnicare system has the ability to connect to a maximum of 127 outstations. The development of OmnicarePLUS has enabled the installation of much larger scale systems. OmnicarePLUS is made up of multiple BS5839-9 compliant local systems which are then connected to form a network. The benefit of OmnicarePLUS is the ability to communicate with any outstation on any part of the network from a single point. This sitewide control is via a graphical touch screensKey FeaturesAbility to connect up to 125 local control points each with 64 outstations - making it possible to connect up to 8000 remotes.Compatible with the entire range of Omnicare outstations.Choice of copper and fibre single or multi-mode networking.Multi-layer graphical touch screen control - see the location of the remote calling.Automatic incoming call queuing with indication of number of waiting calls.Multiple touch screen control locations with optional mimicking of status and faults.Incoming call logging and audio recording via touch screen control locations.All site wiring fully monitored for faults and any faults will be reported and recorded in a time and date stamped log.The network is fault tolerant so that the system will continue to operate in the presence of a single fault.Calls can be accepted locally at Omnicare panels.Optional pin number-based access control at touch screen control locations.Activity reporting including faults detected with date and time stamp.All call announcements can be made via an MCP - paging will be heard at all fire telephones steward telephones and occupied disabled refuge points.A conference call can be initiated from the MCP or an LCP to communicate with the fire and steward telephones connected to a single LCP.System DesignEach OmnicarePLUS project is unique. We have a qualified team that will design build and test the system to suit your specification. If you have a requirement for a particularly large EVC system then please contact our Sales Team who will be happy to discuss your options.

GBP 8371.64
1

Baldwin Boxall BVOCTSC32 OmnicarePLUS Local Control Panel 32-Way

Baldwin Boxall BVOCTSC32 OmnicarePLUS Local Control Panel 32-Way

Baldwin Boxall BVOCTSC32 OmnicarePLUS Local Control Panel 32-WayOmnicarePLUS makes it possible for very large disabled refuge fire telephone EVC systems to be installed.Up until now it has not been possible to install super large EVC systems. However this has all changed you can now have as many as 8064 outstations on a single system We agree that it is extremely unlikely that a system of this size would be required but what it means is that the restrictions have now been liftedOverall site-wide system master control is carried out by the use of a graphic layout on a touch screen PC. The graphic on the screen is multi-layer providing the user with an easy-to-use and instantly recognisable interface for the system.OmnicarePLUS is not limited to a single touch screen control point additional ones can be added to the system enabling placement in alternative control or security rooms. These will be slavesmimic panels unless full control is transferred to the panel due to compromise of the master control point or if required by the users.For local area control i.e. control of the outstations on a single floorareabuilding block specially designed Omnicare panels are employed. Up to 64 outstations can be connected to a local area control panel. Each local area control panel is able to communicate with the outstations connected to that unit.A standard Omnicare system has the ability to connect to a maximum of 127 outstations. The development of OmnicarePLUS has enabled the installation of much larger scale systems. OmnicarePLUS is made up of multiple BS5839-9 compliant local systems which are then connected to form a network. The benefit of OmnicarePLUS is the ability to communicate with any outstation on any part of the network from a single point. This sitewide control is via a graphical touch screensKey FeaturesAbility to connect up to 125 local control points each with 64 outstations - making it possible to connect up to 8000 remotes.Compatible with the entire range of Omnicare outstations.Choice of copper and fibre single or multi-mode networking.Multi-layer graphical touch screen control - see the location of the remote calling.Automatic incoming call queuing with indication of number of waiting calls.Multiple touch screen control locations with optional mimicking of status and faults.Incoming call logging and audio recording via touch screen control locations.All site wiring fully monitored for faults and any faults will be reported and recorded in a time and date stamped log.The network is fault tolerant so that the system will continue to operate in the presence of a single fault.Calls can be accepted locally at Omnicare panels.Optional pin number-based access control at touch screen control locations.Activity reporting including faults detected with date and time stamp.All call announcements can be made via an MCP - paging will be heard at all fire telephones steward telephones and occupied disabled refuge points.A conference call can be initiated from the MCP or an LCP to communicate with the fire and steward telephones connected to a single LCP.System DesignEach OmnicarePLUS project is unique. We have a qualified team that will design build and test the system to suit your specification. If you have a requirement for a particularly large EVC system then please contact our Sales Team who will be happy to discuss your options.

GBP 7660.39
1

Baldwin Boxall BVOCTSC48 OmnicarePLUS Local Control Panel 48-Way

Baldwin Boxall BVOCTSC48 OmnicarePLUS Local Control Panel 48-Way

Baldwin Boxall BVOCTSC48 OmnicarePLUS Local Control Panel 48-WayOmnicarePLUS makes it possible for very large disabled refuge fire telephone EVC systems to be installed.Up until now it has not been possible to install super large EVC systems. However this has all changed you can now have as many as 8064 outstations on a single system We agree that it is extremely unlikely that a system of this size would be required but what it means is that the restrictions have now been liftedOverall site-wide system master control is carried out by the use of a graphic layout on a touch screen PC. The graphic on the screen is multi-layer providing the user with an easy-to-use and instantly recognisable interface for the system.OmnicarePLUS is not limited to a single touch screen control point additional ones can be added to the system enabling placement in alternative control or security rooms. These will be slavesmimic panels unless full control is transferred to the panel due to compromise of the master control point or if required by the users.For local area control i.e. control of the outstations on a single floorareabuilding block specially designed Omnicare panels are employed. Up to 64 outstations can be connected to a local area control panel. Each local area control panel is able to communicate with the outstations connected to that unit.A standard Omnicare system has the ability to connect to a maximum of 127 outstations. The development of OmnicarePLUS has enabled the installation of much larger scale systems. OmnicarePLUS is made up of multiple BS5839-9 compliant local systems which are then connected to form a network. The benefit of OmnicarePLUS is the ability to communicate with any outstation on any part of the network from a single point. This sitewide control is via a graphical touch screensKey FeaturesAbility to connect up to 125 local control points each with 64 outstations - making it possible to connect up to 8000 remotes.Compatible with the entire range of Omnicare outstations.Choice of copper and fibre single or multi-mode networking.Multi-layer graphical touch screen control - see the location of the remote calling.Automatic incoming call queuing with indication of number of waiting calls.Multiple touch screen control locations with optional mimicking of status and faults.Incoming call logging and audio recording via touch screen control locations.All site wiring fully monitored for faults and any faults will be reported and recorded in a time and date stamped log.The network is fault tolerant so that the system will continue to operate in the presence of a single fault.Calls can be accepted locally at Omnicare panels.Optional pin number-based access control at touch screen control locations.Activity reporting including faults detected with date and time stamp.All call announcements can be made via an MCP - paging will be heard at all fire telephones steward telephones and occupied disabled refuge points.A conference call can be initiated from the MCP or an LCP to communicate with the fire and steward telephones connected to a single LCP.System DesignEach OmnicarePLUS project is unique. We have a qualified team that will design build and test the system to suit your specification. If you have a requirement for a particularly large EVC system then please contact our Sales Team who will be happy to discuss your options.

GBP 7952.52
1

Baldwin Boxall BVOCTSC16 OmnicarePLUS Local Control Panel 16-Way

Baldwin Boxall BVOCTSC16 OmnicarePLUS Local Control Panel 16-Way

Baldwin Boxall BVOCTSC16 OmnicarePLUS Local Control Panel 16-WayOmnicarePLUS makes it possible for very large disabled refuge fire telephone EVC systems to be installed.Up until now it has not been possible to install super large EVC systems. However this has all changed you can now have as many as 8064 outstations on a single system We agree that it is extremely unlikely that a system of this size would be required but what it means is that the restrictions have now been liftedOverall site-wide system master control is carried out by the use of a graphic layout on a touch screen PC. The graphic on the screen is multi-layer providing the user with an easy-to-use and instantly recognisable interface for the system.OmnicarePLUS is not limited to a single touch screen control point additional ones can be added to the system enabling placement in alternative control or security rooms. These will be slavesmimic panels unless full control is transferred to the panel due to compromise of the master control point or if required by the users.For local area control i.e. control of the outstations on a single floorareabuilding block specially designed Omnicare panels are employed. Up to 64 outstations can be connected to a local area control panel. Each local area control panel is able to communicate with the outstations connected to that unit.A standard Omnicare system has the ability to connect to a maximum of 127 outstations. The development of OmnicarePLUS has enabled the installation of much larger scale systems. OmnicarePLUS is made up of multiple BS5839-9 compliant local systems which are then connected to form a network. The benefit of OmnicarePLUS is the ability to communicate with any outstation on any part of the network from a single point. This sitewide control is via a graphical touch screensKey FeaturesAbility to connect up to 125 local control points each with 64 outstations - making it possible to connect up to 8000 remotes.Compatible with the entire range of Omnicare outstations.Choice of copper and fibre single or multi-mode networking.Multi-layer graphical touch screen control - see the location of the remote calling.Automatic incoming call queuing with indication of number of waiting calls.Multiple touch screen control locations with optional mimicking of status and faults.Incoming call logging and audio recording via touch screen control locations.All site wiring fully monitored for faults and any faults will be reported and recorded in a time and date stamped log.The network is fault tolerant so that the system will continue to operate in the presence of a single fault.Calls can be accepted locally at Omnicare panels.Optional pin number-based access control at touch screen control locations.Activity reporting including faults detected with date and time stamp.All call announcements can be made via an MCP - paging will be heard at all fire telephones steward telephones and occupied disabled refuge points.A conference call can be initiated from the MCP or an LCP to communicate with the fire and steward telephones connected to a single LCP.System DesignEach OmnicarePLUS project is unique. We have a qualified team that will design build and test the system to suit your specification. If you have a requirement for a particularly large EVC system then please contact our Sales Team who will be happy to discuss your options.

GBP 6913.78
1

Baldwin Boxall BVOCTSC08 OmnicarePLUS Local Control Panel 8-Way

Baldwin Boxall BVOCTSC08 OmnicarePLUS Local Control Panel 8-Way

Baldwin Boxall BVOCTSC08 OmnicarePLUS Local Control Panel 8-WayOmnicarePLUS makes it possible for very large disabled refuge fire telephone EVC systems to be installed.Up until now it has not been possible to install super large EVC systems. However this has all changed you can now have as many as 8064 outstations on a single system We agree that it is extremely unlikely that a system of this size would be required but what it means is that the restrictions have now been liftedOverall site-wide system master control is carried out by the use of a graphic layout on a touch screen PC. The graphic on the screen is multi-layer providing the user with an easy-to-use and instantly recognisable interface for the system.OmnicarePLUS is not limited to a single touch screen control point additional ones can be added to the system enabling placement in alternative control or security rooms. These will be slavesmimic panels unless full control is transferred to the panel due to compromise of the master control point or if required by the users.For local area control i.e. control of the outstations on a single floorareabuilding block specially designed Omnicare panels are employed. Up to 64 outstations can be connected to a local area control panel. Each local area control panel is able to communicate with the outstations connected to that unit.A standard Omnicare system has the ability to connect to a maximum of 127 outstations. The development of OmnicarePLUS has enabled the installation of much larger scale systems. OmnicarePLUS is made up of multiple BS5839-9 compliant local systems which are then connected to form a network. The benefit of OmnicarePLUS is the ability to communicate with any outstation on any part of the network from a single point. This sitewide control is via a graphical touch screensKey FeaturesAbility to connect up to 125 local control points each with 64 outstations - making it possible to connect up to 8000 remotes.Compatible with the entire range of Omnicare outstations.Choice of copper and fibre single or multi-mode networking.Multi-layer graphical touch screen control - see the location of the remote calling.Automatic incoming call queuing with indication of number of waiting calls.Multiple touch screen control locations with optional mimicking of status and faults.Incoming call logging and audio recording via touch screen control locations.All site wiring fully monitored for faults and any faults will be reported and recorded in a time and date stamped log.The network is fault tolerant so that the system will continue to operate in the presence of a single fault.Calls can be accepted locally at Omnicare panels.Optional pin number-based access control at touch screen control locations.Activity reporting including faults detected with date and time stamp.All call announcements can be made via an MCP - paging will be heard at all fire telephones steward telephones and occupied disabled refuge points.A conference call can be initiated from the MCP or an LCP to communicate with the fire and steward telephones connected to a single LCP.System DesignEach OmnicarePLUS project is unique. We have a qualified team that will design build and test the system to suit your specification. If you have a requirement for a particularly large EVC system then please contact our Sales Team who will be happy to discuss your options.

GBP 6586.27
1