67 results (0,14593 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Baldwin Boxall Fire Panel Interface BVRDFPI

Baldwin Boxall Care2 EVC Network Expansion Panel C2CSNEP

Baldwin Boxall CARE2 Network Expansion Panel 4-way C2CBNEP

Baldwin Boxall Omnicare Mini EVC Control Panel 8-way BVOC8M

Baldwin Boxall Omnicare Mini EVC Control Panel 8-way BVOC8M

Baldwin Boxall Omnicare Mini EVC Control Panel 8-way BVOC8MOmnicare is a loop wired addressable emergency voice communication system that allows disabled refuge fire telephones steward telephones and disabled toilet alarms to be connected to one panel. Omnicare can be easily networked with the ability to add multiple control panels on a system. This enables local zonearea control with gatehousemanagement control on a master panel.The control panel features an output for an external call indicator. This is designed for use in situations where the control panel is mounted in an unmanned area. Using this output a remote indicator can be fitted in a location where it is visibleheard such as in a reception area. The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote lampbuzzer indicator.Panel options include sizes from four-way up to 128-way and are supplied with the relevant batteries for backup should the mains power fail. Four-way up to 128-way versions of the control panel available in either grey or stainless-steel finish. Omnicare has been designed and built to meet BS99992008 BS5839-92011 and BS83002009 for the disabled toilet alarm.Key FeaturesDigital audio full duplex or speech steered remote dependent.One master and multiple slaves can be networked on one system panels are configured on installation.Surface mountable or optional flush mounting with bezel.Dedicated button control for each outstation with status LED indicators.Lockable glazed door.Remote units are connected to the master control panel in a loop configuration using fire rated enhanced four-core cable. OmniCare cabling networking.Fully monitored and battery backed separate box to house batteries supplied with panels larger than 32-way.The system is addressable via the remote units.System BenefitsMultiple masterslave panels can be linked in one system.Full system monitoring.Choice of outstations including disabled toilet alarms addressable via the remote unit.Link to fire detection system prevents hoax disabled refuge calls toilet alarms and fire telephones remain active. Can be completely or partly overridden.Speech steered disabled refuge remotes and full duplex speech fire telephones and emergency telephones.Battery backed for use in the event of mains power failure 24 hours in standby plus three hours use as standard. These times can be increased if required. Please contact our Sales Department for advice.Wired in a loop configuration.

GBP 1729.13
1

Baldwin Boxall Omnicare Large EVC Control Panel 112-way BVOC112

Baldwin Boxall Omnicare Large EVC Control Panel 112-way BVOC112

Baldwin Boxall Omnicare Large EVC Control Panel 112-way BVOC112Omnicare is a loop wired addressable emergency voice communication system that allows disabled refuge fire telephones steward telephones and disabled toilet alarms to be connected to one panel. Omnicare can be easily networked with the ability to add multiple control panels on a system. This enables local zonearea control with gatehousemanagement control on a master panel.The control panel features an output for an external call indicator. This is designed for use in situations where the control panel is mounted in an unmanned area. Using this output a remote indicator can be fitted in a location where it is visibleheard such as in a reception area. The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote lampbuzzer indicator.Panel options include sizes from four-way up to 128-way and are supplied with the relevant batteries for backup should the mains power fail. Four-way up to 128-way versions of the control panel available in either grey or stainless-steel finish. Omnicare has been designed and built to meet BS99992008 BS5839-92011 and BS83002009 for the disabled toilet alarm.Key FeaturesDigital audio full duplex or speech steered remote dependent.One master and multiple slaves can be networked on one system panels are configured on installation.Surface mountable or optional flush mounting with bezel.Dedicated button control for each outstation with status LED indicators.Lockable glazed door.Remote units are connected to the master control panel in a loop configuration using fire rated enhanced four-core cable. OmniCare cabling networking.Fully monitored and battery backed separate box to house batteries supplied with panels larger than 32-way.The system is addressable via the remote units.System BenefitsMultiple masterslave panels can be linked in one system.Full system monitoring.Choice of outstations including disabled toilet alarms addressable via the remote unit.Link to fire detection system prevents hoax disabled refuge calls toilet alarms and fire telephones remain active. Can be completely or partly overridden.Speech steered disabled refuge remotes and full duplex speech fire telephones and emergency telephones.Battery backed for use in the event of mains power failure 24 hours in standby plus three hours use as standard. These times can be increased if required. Please contact our Sales Department for advice.Wired in a loop configuration.

GBP 6382.15
1

Baldwin Boxall Omnicare Large EVC Control Panel 80-way BVOC80

Baldwin Boxall Omnicare Large EVC Control Panel 80-way BVOC80

Baldwin Boxall Omnicare Large EVC Control Panel 80-way BVOC80Omnicare is a loop wired addressable emergency voice communication system that allows disabled refuge fire telephones steward telephones and disabled toilet alarms to be connected to one panel. Omnicare can be easily networked with the ability to add multiple control panels on a system. This enables local zonearea control with gatehousemanagement control on a master panel.The control panel features an output for an external call indicator. This is designed for use in situations where the control panel is mounted in an unmanned area. Using this output a remote indicator can be fitted in a location where it is visibleheard such as in a reception area. The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote lampbuzzer indicator.Panel options include sizes from four-way up to 128-way and are supplied with the relevant batteries for backup should the mains power fail. Four-way up to 128-way versions of the control panel available in either grey or stainless-steel finish. Omnicare has been designed and built to meet BS99992008 BS5839-92011 and BS83002009 for the disabled toilet alarm.Key FeaturesDigital audio full duplex or speech steered remote dependent.One master and multiple slaves can be networked on one system panels are configured on installation.Surface mountable or optional flush mounting with bezel.Dedicated button control for each outstation with status LED indicators.Lockable glazed door.Remote units are connected to the master control panel in a loop configuration using fire rated enhanced four-core cable. OmniCare cabling networking.Fully monitored and battery backed separate box to house batteries supplied with panels larger than 32-way.The system is addressable via the remote units.System BenefitsMultiple masterslave panels can be linked in one system.Full system monitoring.Choice of outstations including disabled toilet alarms addressable via the remote unit.Link to fire detection system prevents hoax disabled refuge calls toilet alarms and fire telephones remain active. Can be completely or partly overridden.Speech steered disabled refuge remotes and full duplex speech fire telephones and emergency telephones.Battery backed for use in the event of mains power failure 24 hours in standby plus three hours use as standard. These times can be increased if required. Please contact our Sales Department for advice.Wired in a loop configuration.

GBP 5857.79
1

Baldwin Boxall Omnicare Standard EVC Control Panel 64-way BVOC64

Baldwin Boxall Omnicare Standard EVC Control Panel 64-way BVOC64

Baldwin Boxall Omnicare Standard EVC Control Panel 64-way BVOC64Omnicare is a loop wired addressable emergency voice communication system that allows disabled refuge fire telephones steward telephones and disabled toilet alarms to be connected to one panel. Omnicare can be easily networked with the ability to add multiple control panels on a system. This enables local zonearea control with gatehousemanagement control on a master panel.The control panel features an output for an external call indicator. This is designed for use in situations where the control panel is mounted in an unmanned area. Using this output a remote indicator can be fitted in a location where it is visibleheard such as in a reception area. The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote lampbuzzer indicator.Panel options include sizes from four-way up to 128-way and are supplied with the relevant batteries for backup should the mains power fail. Four-way up to 128-way versions of the control panel available in either grey or stainless-steel finish. Omnicare has been designed and built to meet BS99992008 BS5839-92011 and BS83002009 for the disabled toilet alarm.Key FeaturesDigital audio full duplex or speech steered remote dependent.One master and multiple slaves can be networked on one system panels are configured on installation.Surface mountable or optional flush mounting with bezel.Dedicated button control for each outstation with status LED indicators.Lockable glazed door.Remote units are connected to the master control panel in a loop configuration using fire rated enhanced four-core cable. OmniCare cabling networking.Fully monitored and battery backed separate box to house batteries supplied with panels larger than 32-way.The system is addressable via the remote units.System BenefitsMultiple masterslave panels can be linked in one system.Full system monitoring.Choice of outstations including disabled toilet alarms addressable via the remote unit.Link to fire detection system prevents hoax disabled refuge calls toilet alarms and fire telephones remain active. Can be completely or partly overridden.Speech steered disabled refuge remotes and full duplex speech fire telephones and emergency telephones.Battery backed for use in the event of mains power failure 24 hours in standby plus three hours use as standard. These times can be increased if required. Please contact our Sales Department for advice.Wired in a loop configuration.

GBP 4292.87
1

Baldwin Boxall Omnicare Large EVC Control Panel 128-way BVOC128

Baldwin Boxall Omnicare Large EVC Control Panel 128-way BVOC128

Baldwin Boxall Omnicare Large EVC Control Panel 128-way BVOC128Omnicare is a loop wired addressable emergency voice communication system that allows disabled refuge fire telephones steward telephones and disabled toilet alarms to be connected to one panel. Omnicare can be easily networked with the ability to add multiple control panels on a system. This enables local zonearea control with gatehousemanagement control on a master panel.The control panel features an output for an external call indicator. This is designed for use in situations where the control panel is mounted in an unmanned area. Using this output a remote indicator can be fitted in a location where it is visibleheard such as in a reception area. The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote lampbuzzer indicator.Panel options include sizes from four-way up to 128-way and are supplied with the relevant batteries for backup should the mains power fail. Four-way up to 128-way versions of the control panel available in either grey or stainless-steel finish. Omnicare has been designed and built to meet BS99992008 BS5839-92011 and BS83002009 for the disabled toilet alarm.Key FeaturesDigital audio full duplex or speech steered remote dependent.One master and multiple slaves can be networked on one system panels are configured on installation.Surface mountable or optional flush mounting with bezel.Dedicated button control for each outstation with status LED indicators.Lockable glazed door.Remote units are connected to the master control panel in a loop configuration using fire rated enhanced four-core cable. OmniCare cabling networking.Fully monitored and battery backed separate box to house batteries supplied with panels larger than 32-way.The system is addressable via the remote units.System BenefitsMultiple masterslave panels can be linked in one system.Full system monitoring.Choice of outstations including disabled toilet alarms addressable via the remote unit.Link to fire detection system prevents hoax disabled refuge calls toilet alarms and fire telephones remain active. Can be completely or partly overridden.Speech steered disabled refuge remotes and full duplex speech fire telephones and emergency telephones.Battery backed for use in the event of mains power failure 24 hours in standby plus three hours use as standard. These times can be increased if required. Please contact our Sales Department for advice.Wired in a loop configuration.

GBP 6592.62
1

Baldwin Boxall Omnicare Mini EVC Control Panel 32-way BVOC32M

Baldwin Boxall Omnicare Mini EVC Control Panel 32-way BVOC32M

Baldwin Boxall Omnicare Mini EVC Control Panel 32-way BVOC32MOmnicare is a loop wired addressable emergency voice communication system that allows disabled refuge fire telephones steward telephones and disabled toilet alarms to be connected to one panel. Omnicare can be easily networked with the ability to add multiple control panels on a system. This enables local zonearea control with gatehousemanagement control on a master panel.The control panel features an output for an external call indicator. This is designed for use in situations where the control panel is mounted in an unmanned area. Using this output a remote indicator can be fitted in a location where it is visibleheard such as in a reception area. The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote lampbuzzer indicator.Panel options include sizes from four-way up to 128-way and are supplied with the relevant batteries for backup should the mains power fail. Four-way up to 128-way versions of the control panel available in either grey or stainless-steel finish. Omnicare has been designed and built to meet BS99992008 BS5839-92011 and BS83002009 for the disabled toilet alarm.Key FeaturesDigital audio full duplex or speech steered remote dependent.One master and multiple slaves can be networked on one system panels are configured on installation.Surface mountable or optional flush mounting with bezel.Dedicated button control for each outstation with status LED indicators.Lockable glazed door.Remote units are connected to the master control panel in a loop configuration using fire rated enhanced four-core cable. OmniCare cabling networking.Fully monitored and battery backed separate box to house batteries supplied with panels larger than 32-way.The system is addressable via the remote units.System BenefitsMultiple masterslave panels can be linked in one system.Full system monitoring.Choice of outstations including disabled toilet alarms addressable via the remote unit.Link to fire detection system prevents hoax disabled refuge calls toilet alarms and fire telephones remain active. Can be completely or partly overridden.Speech steered disabled refuge remotes and full duplex speech fire telephones and emergency telephones.Battery backed for use in the event of mains power failure 24 hours in standby plus three hours use as standard. These times can be increased if required. Please contact our Sales Department for advice.Wired in a loop configuration.

GBP 2522.93
1

Baldwin Boxall Omnicare Large EVC Control Panel 96-way BVOC96

Baldwin Boxall Omnicare Large EVC Control Panel 96-way BVOC96

Baldwin Boxall Omnicare Large EVC Control Panel 96-way BVOC96Omnicare is a loop wired addressable emergency voice communication system that allows disabled refuge fire telephones steward telephones and disabled toilet alarms to be connected to one panel. Omnicare can be easily networked with the ability to add multiple control panels on a system. This enables local zonearea control with gatehousemanagement control on a master panel.The control panel features an output for an external call indicator. This is designed for use in situations where the control panel is mounted in an unmanned area. Using this output a remote indicator can be fitted in a location where it is visibleheard such as in a reception area. The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote lampbuzzer indicator.Panel options include sizes from four-way up to 128-way and are supplied with the relevant batteries for backup should the mains power fail. Four-way up to 128-way versions of the control panel available in either grey or stainless-steel finish. Omnicare has been designed and built to meet BS99992008 BS5839-92011 and BS83002009 for the disabled toilet alarm.Key FeaturesDigital audio full duplex or speech steered remote dependent.One master and multiple slaves can be networked on one system panels are configured on installation.Surface mountable or optional flush mounting with bezel.Dedicated button control for each outstation with status LED indicators.Lockable glazed door.Remote units are connected to the master control panel in a loop configuration using fire rated enhanced four-core cable. OmniCare cabling networking.Fully monitored and battery backed separate box to house batteries supplied with panels larger than 32-way.The system is addressable via the remote units.System BenefitsMultiple masterslave panels can be linked in one system.Full system monitoring.Choice of outstations including disabled toilet alarms addressable via the remote unit.Link to fire detection system prevents hoax disabled refuge calls toilet alarms and fire telephones remain active. Can be completely or partly overridden.Speech steered disabled refuge remotes and full duplex speech fire telephones and emergency telephones.Battery backed for use in the event of mains power failure 24 hours in standby plus three hours use as standard. These times can be increased if required. Please contact our Sales Department for advice.Wired in a loop configuration.

GBP 5951.23
1

Baldwin Boxall Omnicare Standard EVC Control Panel 48-way BVOC48

Baldwin Boxall Omnicare Standard EVC Control Panel 48-way BVOC48

Baldwin Boxall Omnicare Standard EVC Control Panel 48-way BVOC48Omnicare is a loop wired addressable emergency voice communication system that allows disabled refuge fire telephones steward telephones and disabled toilet alarms to be connected to one panel. Omnicare can be easily networked with the ability to add multiple control panels on a system. This enables local zonearea control with gatehousemanagement control on a master panel.The control panel features an output for an external call indicator. This is designed for use in situations where the control panel is mounted in an unmanned area. Using this output a remote indicator can be fitted in a location where it is visibleheard such as in a reception area. The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote lampbuzzer indicator.Panel options include sizes from four-way up to 128-way and are supplied with the relevant batteries for backup should the mains power fail. Four-way up to 128-way versions of the control panel available in either grey or stainless-steel finish. Omnicare has been designed and built to meet BS99992008 BS5839-92011 and BS83002009 for the disabled toilet alarm.Key FeaturesDigital audio full duplex or speech steered remote dependent.One master and multiple slaves can be networked on one system panels are configured on installation.Surface mountable or optional flush mounting with bezel.Dedicated button control for each outstation with status LED indicators.Lockable glazed door.Remote units are connected to the master control panel in a loop configuration using fire rated enhanced four-core cable. OmniCare cabling networking.Fully monitored and battery backed separate box to house batteries supplied with panels larger than 32-way.The system is addressable via the remote units.System BenefitsMultiple masterslave panels can be linked in one system.Full system monitoring.Choice of outstations including disabled toilet alarms addressable via the remote unit.Link to fire detection system prevents hoax disabled refuge calls toilet alarms and fire telephones remain active. Can be completely or partly overridden.Speech steered disabled refuge remotes and full duplex speech fire telephones and emergency telephones.Battery backed for use in the event of mains power failure 24 hours in standby plus three hours use as standard. These times can be increased if required. Please contact our Sales Department for advice.Wired in a loop configuration.

GBP 3689.58
1

Baldwin Boxall Omnicare Mini EVC Control Panel 16-way BVOC16M

Baldwin Boxall Omnicare Mini EVC Control Panel 16-way BVOC16M

Baldwin Boxall Omnicare Mini EVC Control Panel 16-way BVOC16MOmnicare is a loop wired addressable emergency voice communication system that allows disabled refuge fire telephones steward telephones and disabled toilet alarms to be connected to one panel. Omnicare can be easily networked with the ability to add multiple control panels on a system. This enables local zonearea control with gatehousemanagement control on a master panel.The control panel features an output for an external call indicator. This is designed for use in situations where the control panel is mounted in an unmanned area. Using this output a remote indicator can be fitted in a location where it is visibleheard such as in a reception area. The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote lampbuzzer indicator.Panel options include sizes from four-way up to 128-way and are supplied with the relevant batteries for backup should the mains power fail. Four-way up to 128-way versions of the control panel available in either grey or stainless-steel finish. Omnicare has been designed and built to meet BS99992008 BS5839-92011 and BS83002009 for the disabled toilet alarm.Key FeaturesDigital audio full duplex or speech steered remote dependent.One master and multiple slaves can be networked on one system panels are configured on installation.Surface mountable or optional flush mounting with bezel.Dedicated button control for each outstation with status LED indicators.Lockable glazed door.Remote units are connected to the master control panel in a loop configuration using fire rated enhanced four-core cable. OmniCare cabling networking.Fully monitored and battery backed separate box to house batteries supplied with panels larger than 32-way.The system is addressable via the remote units.System BenefitsMultiple masterslave panels can be linked in one system.Full system monitoring.Choice of outstations including disabled toilet alarms addressable via the remote unit.Link to fire detection system prevents hoax disabled refuge calls toilet alarms and fire telephones remain active. Can be completely or partly overridden.Speech steered disabled refuge remotes and full duplex speech fire telephones and emergency telephones.Battery backed for use in the event of mains power failure 24 hours in standby plus three hours use as standard. These times can be increased if required. Please contact our Sales Department for advice.Wired in a loop configuration.

GBP 1843.43
1

Baldwin Boxall Omnicare Mini EVC Control Panel 4-way BVOC4M

Baldwin Boxall Omnicare Mini EVC Control Panel 4-way BVOC4M

Baldwin Boxall Omnicare Mini EVC Control Panel 4-way BVOC4MOmnicare is a loop wired addressable emergency voice communication system that allows disabled refuge fire telephones steward telephones and disabled toilet alarms to be connected to one panel. Omnicare can be easily networked with the ability to add multiple control panels on a system. This enables local zonearea control with gatehousemanagement control on a master panel.The control panel features an output for an external call indicator. This is designed for use in situations where the control panel is mounted in an unmanned area. Using this output a remote indicator can be fitted in a location where it is visibleheard such as in a reception area. The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote lampbuzzer indicator.Panel options include sizes from four-way up to 128-way and are supplied with the relevant batteries for backup should the mains power fail. Four-way up to 128-way versions of the control panel available in either grey or stainless-steel finish. Omnicare has been designed and built to meet BS99992008 BS5839-92011 and BS83002009 for the disabled toilet alarm.Key FeaturesDigital audio full duplex or speech steered remote dependent.One master and multiple slaves can be networked on one system panels are configured on installation.Surface mountable or optional flush mounting with bezel.Dedicated button control for each outstation with status LED indicators.Lockable glazed door.Remote units are connected to the master control panel in a loop configuration using fire rated enhanced four-core cable. OmniCare cabling networking.Fully monitored and battery backed separate box to house batteries supplied with panels larger than 32-way.The system is addressable via the remote units.System BenefitsMultiple masterslave panels can be linked in one system.Full system monitoring.Choice of outstations including disabled toilet alarms addressable via the remote unit.Link to fire detection system prevents hoax disabled refuge calls toilet alarms and fire telephones remain active. Can be completely or partly overridden.Speech steered disabled refuge remotes and full duplex speech fire telephones and emergency telephones.Battery backed for use in the event of mains power failure 24 hours in standby plus three hours use as standard. These times can be increased if required. Please contact our Sales Department for advice.Wired in a loop configuration.

GBP 1578.53
1

Baldwin Boxall BVOC16M72 Omnicare Mini EVC Control Panel 16-Way - 72 Hours

Baldwin Boxall BVOC16M72 Omnicare Mini EVC Control Panel 16-Way - 72 Hours

Baldwin Boxall BVOC16M72 Omnicare Mini EVC Control Panel 16-Way - 72 HoursOmnicare is a loop wired addressable emergency voice communication system that allows disabled refuge fire telephones steward telephones and disabled toilet alarms to be connected to one panel. Omnicare can be easily networked with the ability to add multiple control panels on a system. This enables local zonearea control with gatehousemanagement control on a master panel.The control panel features an output for an external call indicator. This is designed for use in situations where the control panel is mounted in an unmanned area. Using this output a remote indicator can be fitted in a location where it is visibleheard such as in a reception area. The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote lampbuzzer indicator.Panel options include sizes from four-way up to 128-way and are supplied with the relevant batteries for backup should the mains power fail. Four-way up to 128-way versions of the control panel available in either grey or stainless-steel finish. Omnicare has been designed and built to meet BS99992008 BS5839-92011 and BS83002009 for the disabled toilet alarm.Key FeaturesDigital audio full duplex or speech steered remote dependent.One master and multiple slaves can be networked on one system panels are configured on installation.Surface mountable or optional flush mounting with bezel.Dedicated button control for each outstation with status LED indicators.Lockable glazed door.Remote units are connected to the master control panel in a loop configuration using fire rated enhanced four-core cable. OmniCare cabling networking.Fully monitored and battery backed separate box to house batteries supplied with panels larger than 32-way.The system is addressable via the remote units.System BenefitsMultiple masterslave panels can be linked in one system.Full system monitoring.Choice of outstations including disabled toilet alarms addressable via the remote unit.Link to fire detection system prevents hoax disabled refuge calls toilet alarms and fire telephones remain active. Can be completely or partly overridden.Speech steered disabled refuge remotes and full duplex speech fire telephones and emergency telephones.Battery backed for use in the event of mains power failure 24 hours in standby plus three hours use as standard. These times can be increased if required. Please contact our Sales Department for advice.Wired in a loop configuration.

GBP 2017.61
1

Baldwin Boxall BVOCTSC16 OmnicarePLUS Local Control Panel 16-Way

Baldwin Boxall BVOCTSC16 OmnicarePLUS Local Control Panel 16-Way

Baldwin Boxall BVOCTSC16 OmnicarePLUS Local Control Panel 16-WayOmnicarePLUS makes it possible for very large disabled refuge fire telephone EVC systems to be installed.Up until now it has not been possible to install super large EVC systems. However this has all changed you can now have as many as 8064 outstations on a single system We agree that it is extremely unlikely that a system of this size would be required but what it means is that the restrictions have now been liftedOverall site-wide system master control is carried out by the use of a graphic layout on a touch screen PC. The graphic on the screen is multi-layer providing the user with an easy-to-use and instantly recognisable interface for the system.OmnicarePLUS is not limited to a single touch screen control point additional ones can be added to the system enabling placement in alternative control or security rooms. These will be slavesmimic panels unless full control is transferred to the panel due to compromise of the master control point or if required by the users.For local area control i.e. control of the outstations on a single floorareabuilding block specially designed Omnicare panels are employed. Up to 64 outstations can be connected to a local area control panel. Each local area control panel is able to communicate with the outstations connected to that unit.A standard Omnicare system has the ability to connect to a maximum of 127 outstations. The development of OmnicarePLUS has enabled the installation of much larger scale systems. OmnicarePLUS is made up of multiple BS5839-9 compliant local systems which are then connected to form a network. The benefit of OmnicarePLUS is the ability to communicate with any outstation on any part of the network from a single point. This sitewide control is via a graphical touch screensKey FeaturesAbility to connect up to 125 local control points each with 64 outstations - making it possible to connect up to 8000 remotes.Compatible with the entire range of Omnicare outstations.Choice of copper and fibre single or multi-mode networking.Multi-layer graphical touch screen control - see the location of the remote calling.Automatic incoming call queuing with indication of number of waiting calls.Multiple touch screen control locations with optional mimicking of status and faults.Incoming call logging and audio recording via touch screen control locations.All site wiring fully monitored for faults and any faults will be reported and recorded in a time and date stamped log.The network is fault tolerant so that the system will continue to operate in the presence of a single fault.Calls can be accepted locally at Omnicare panels.Optional pin number-based access control at touch screen control locations.Activity reporting including faults detected with date and time stamp.All call announcements can be made via an MCP - paging will be heard at all fire telephones steward telephones and occupied disabled refuge points.A conference call can be initiated from the MCP or an LCP to communicate with the fire and steward telephones connected to a single LCP.System DesignEach OmnicarePLUS project is unique. We have a qualified team that will design build and test the system to suit your specification. If you have a requirement for a particularly large EVC system then please contact our Sales Team who will be happy to discuss your options.

GBP 6913.78
1

Baldwin Boxall BVOCTSC08 OmnicarePLUS Local Control Panel 8-Way

Baldwin Boxall BVOCTSC08 OmnicarePLUS Local Control Panel 8-Way

Baldwin Boxall BVOCTSC08 OmnicarePLUS Local Control Panel 8-WayOmnicarePLUS makes it possible for very large disabled refuge fire telephone EVC systems to be installed.Up until now it has not been possible to install super large EVC systems. However this has all changed you can now have as many as 8064 outstations on a single system We agree that it is extremely unlikely that a system of this size would be required but what it means is that the restrictions have now been liftedOverall site-wide system master control is carried out by the use of a graphic layout on a touch screen PC. The graphic on the screen is multi-layer providing the user with an easy-to-use and instantly recognisable interface for the system.OmnicarePLUS is not limited to a single touch screen control point additional ones can be added to the system enabling placement in alternative control or security rooms. These will be slavesmimic panels unless full control is transferred to the panel due to compromise of the master control point or if required by the users.For local area control i.e. control of the outstations on a single floorareabuilding block specially designed Omnicare panels are employed. Up to 64 outstations can be connected to a local area control panel. Each local area control panel is able to communicate with the outstations connected to that unit.A standard Omnicare system has the ability to connect to a maximum of 127 outstations. The development of OmnicarePLUS has enabled the installation of much larger scale systems. OmnicarePLUS is made up of multiple BS5839-9 compliant local systems which are then connected to form a network. The benefit of OmnicarePLUS is the ability to communicate with any outstation on any part of the network from a single point. This sitewide control is via a graphical touch screensKey FeaturesAbility to connect up to 125 local control points each with 64 outstations - making it possible to connect up to 8000 remotes.Compatible with the entire range of Omnicare outstations.Choice of copper and fibre single or multi-mode networking.Multi-layer graphical touch screen control - see the location of the remote calling.Automatic incoming call queuing with indication of number of waiting calls.Multiple touch screen control locations with optional mimicking of status and faults.Incoming call logging and audio recording via touch screen control locations.All site wiring fully monitored for faults and any faults will be reported and recorded in a time and date stamped log.The network is fault tolerant so that the system will continue to operate in the presence of a single fault.Calls can be accepted locally at Omnicare panels.Optional pin number-based access control at touch screen control locations.Activity reporting including faults detected with date and time stamp.All call announcements can be made via an MCP - paging will be heard at all fire telephones steward telephones and occupied disabled refuge points.A conference call can be initiated from the MCP or an LCP to communicate with the fire and steward telephones connected to a single LCP.System DesignEach OmnicarePLUS project is unique. We have a qualified team that will design build and test the system to suit your specification. If you have a requirement for a particularly large EVC system then please contact our Sales Team who will be happy to discuss your options.

GBP 6586.27
1

Baldwin Boxall BVOCTSC64 OmnicarePLUS Local Control Panel 64-Way

Baldwin Boxall BVOCTSC64 OmnicarePLUS Local Control Panel 64-Way

Baldwin Boxall BVOCTSC64 OmnicarePLUS Local Control Panel 64-WayOmnicarePLUS makes it possible for very large disabled refuge fire telephone EVC systems to be installed.Up until now it has not been possible to install super large EVC systems. However this has all changed you can now have as many as 8064 outstations on a single system We agree that it is extremely unlikely that a system of this size would be required but what it means is that the restrictions have now been liftedOverall site-wide system master control is carried out by the use of a graphic layout on a touch screen PC. The graphic on the screen is multi-layer providing the user with an easy-to-use and instantly recognisable interface for the system.OmnicarePLUS is not limited to a single touch screen control point additional ones can be added to the system enabling placement in alternative control or security rooms. These will be slavesmimic panels unless full control is transferred to the panel due to compromise of the master control point or if required by the users.For local area control i.e. control of the outstations on a single floorareabuilding block specially designed Omnicare panels are employed. Up to 64 outstations can be connected to a local area control panel. Each local area control panel is able to communicate with the outstations connected to that unit.A standard Omnicare system has the ability to connect to a maximum of 127 outstations. The development of OmnicarePLUS has enabled the installation of much larger scale systems. OmnicarePLUS is made up of multiple BS5839-9 compliant local systems which are then connected to form a network. The benefit of OmnicarePLUS is the ability to communicate with any outstation on any part of the network from a single point. This sitewide control is via a graphical touch screensKey FeaturesAbility to connect up to 125 local control points each with 64 outstations - making it possible to connect up to 8000 remotes.Compatible with the entire range of Omnicare outstations.Choice of copper and fibre single or multi-mode networking.Multi-layer graphical touch screen control - see the location of the remote calling.Automatic incoming call queuing with indication of number of waiting calls.Multiple touch screen control locations with optional mimicking of status and faults.Incoming call logging and audio recording via touch screen control locations.All site wiring fully monitored for faults and any faults will be reported and recorded in a time and date stamped log.The network is fault tolerant so that the system will continue to operate in the presence of a single fault.Calls can be accepted locally at Omnicare panels.Optional pin number-based access control at touch screen control locations.Activity reporting including faults detected with date and time stamp.All call announcements can be made via an MCP - paging will be heard at all fire telephones steward telephones and occupied disabled refuge points.A conference call can be initiated from the MCP or an LCP to communicate with the fire and steward telephones connected to a single LCP.System DesignEach OmnicarePLUS project is unique. We have a qualified team that will design build and test the system to suit your specification. If you have a requirement for a particularly large EVC system then please contact our Sales Team who will be happy to discuss your options.

GBP 8371.64
1

Baldwin Boxall BVOCTSC32 OmnicarePLUS Local Control Panel 32-Way

Baldwin Boxall BVOCTSC32 OmnicarePLUS Local Control Panel 32-Way

Baldwin Boxall BVOCTSC32 OmnicarePLUS Local Control Panel 32-WayOmnicarePLUS makes it possible for very large disabled refuge fire telephone EVC systems to be installed.Up until now it has not been possible to install super large EVC systems. However this has all changed you can now have as many as 8064 outstations on a single system We agree that it is extremely unlikely that a system of this size would be required but what it means is that the restrictions have now been liftedOverall site-wide system master control is carried out by the use of a graphic layout on a touch screen PC. The graphic on the screen is multi-layer providing the user with an easy-to-use and instantly recognisable interface for the system.OmnicarePLUS is not limited to a single touch screen control point additional ones can be added to the system enabling placement in alternative control or security rooms. These will be slavesmimic panels unless full control is transferred to the panel due to compromise of the master control point or if required by the users.For local area control i.e. control of the outstations on a single floorareabuilding block specially designed Omnicare panels are employed. Up to 64 outstations can be connected to a local area control panel. Each local area control panel is able to communicate with the outstations connected to that unit.A standard Omnicare system has the ability to connect to a maximum of 127 outstations. The development of OmnicarePLUS has enabled the installation of much larger scale systems. OmnicarePLUS is made up of multiple BS5839-9 compliant local systems which are then connected to form a network. The benefit of OmnicarePLUS is the ability to communicate with any outstation on any part of the network from a single point. This sitewide control is via a graphical touch screensKey FeaturesAbility to connect up to 125 local control points each with 64 outstations - making it possible to connect up to 8000 remotes.Compatible with the entire range of Omnicare outstations.Choice of copper and fibre single or multi-mode networking.Multi-layer graphical touch screen control - see the location of the remote calling.Automatic incoming call queuing with indication of number of waiting calls.Multiple touch screen control locations with optional mimicking of status and faults.Incoming call logging and audio recording via touch screen control locations.All site wiring fully monitored for faults and any faults will be reported and recorded in a time and date stamped log.The network is fault tolerant so that the system will continue to operate in the presence of a single fault.Calls can be accepted locally at Omnicare panels.Optional pin number-based access control at touch screen control locations.Activity reporting including faults detected with date and time stamp.All call announcements can be made via an MCP - paging will be heard at all fire telephones steward telephones and occupied disabled refuge points.A conference call can be initiated from the MCP or an LCP to communicate with the fire and steward telephones connected to a single LCP.System DesignEach OmnicarePLUS project is unique. We have a qualified team that will design build and test the system to suit your specification. If you have a requirement for a particularly large EVC system then please contact our Sales Team who will be happy to discuss your options.

GBP 7660.39
1

Baldwin Boxall BVOCTSC48 OmnicarePLUS Local Control Panel 48-Way

Baldwin Boxall BVOCTSC48 OmnicarePLUS Local Control Panel 48-Way

Baldwin Boxall BVOCTSC48 OmnicarePLUS Local Control Panel 48-WayOmnicarePLUS makes it possible for very large disabled refuge fire telephone EVC systems to be installed.Up until now it has not been possible to install super large EVC systems. However this has all changed you can now have as many as 8064 outstations on a single system We agree that it is extremely unlikely that a system of this size would be required but what it means is that the restrictions have now been liftedOverall site-wide system master control is carried out by the use of a graphic layout on a touch screen PC. The graphic on the screen is multi-layer providing the user with an easy-to-use and instantly recognisable interface for the system.OmnicarePLUS is not limited to a single touch screen control point additional ones can be added to the system enabling placement in alternative control or security rooms. These will be slavesmimic panels unless full control is transferred to the panel due to compromise of the master control point or if required by the users.For local area control i.e. control of the outstations on a single floorareabuilding block specially designed Omnicare panels are employed. Up to 64 outstations can be connected to a local area control panel. Each local area control panel is able to communicate with the outstations connected to that unit.A standard Omnicare system has the ability to connect to a maximum of 127 outstations. The development of OmnicarePLUS has enabled the installation of much larger scale systems. OmnicarePLUS is made up of multiple BS5839-9 compliant local systems which are then connected to form a network. The benefit of OmnicarePLUS is the ability to communicate with any outstation on any part of the network from a single point. This sitewide control is via a graphical touch screensKey FeaturesAbility to connect up to 125 local control points each with 64 outstations - making it possible to connect up to 8000 remotes.Compatible with the entire range of Omnicare outstations.Choice of copper and fibre single or multi-mode networking.Multi-layer graphical touch screen control - see the location of the remote calling.Automatic incoming call queuing with indication of number of waiting calls.Multiple touch screen control locations with optional mimicking of status and faults.Incoming call logging and audio recording via touch screen control locations.All site wiring fully monitored for faults and any faults will be reported and recorded in a time and date stamped log.The network is fault tolerant so that the system will continue to operate in the presence of a single fault.Calls can be accepted locally at Omnicare panels.Optional pin number-based access control at touch screen control locations.Activity reporting including faults detected with date and time stamp.All call announcements can be made via an MCP - paging will be heard at all fire telephones steward telephones and occupied disabled refuge points.A conference call can be initiated from the MCP or an LCP to communicate with the fire and steward telephones connected to a single LCP.System DesignEach OmnicarePLUS project is unique. We have a qualified team that will design build and test the system to suit your specification. If you have a requirement for a particularly large EVC system then please contact our Sales Team who will be happy to discuss your options.

GBP 7952.52
1

Baldwin Boxall CARE2 EVC Control Panel 4-way C2CB4

Baldwin Boxall CARE2 EVC Control Panel 4-way C2CB4

Baldwin Boxall CARE2 EVC Control Panel 4-way C2CB4Care2 is a radial wired emergency voice communication system built to the high standard you expect from Baldwin Boxall. It is stylish versatile and easy to use and offers an alternative to our well-established loop-wired Omnicare range.Key FeaturesCARE2 is an all-in-one Emergency Voice Communication EVC system.Fully monitored and battery-backed 24 hours quiescent and three hours functional.Fully compliant to BS5839-92011. Assists companies with compliance to BS99992008.Remote units are wired in a radial star configuration using two core fire resisting enhancednon-enhanced cable.Fully networkable. Networked panels are wired in a loop configuration using 2 x two core fire resisting enhanced cable.In the event of a break in the network loop the system will continue to function.All outstations are powered from the line including the roaming telephone enclosure and disabled toilet alarms.Optional link to fire detection system prevents hoax disabled refuge calls C2CFPE required. Firefighter roaming telephones and toilet alarms remain active.Speech steered disabled refuge outstations.Full duplex speech firefighter and emergencysteward telephones.Any combination of the following outstations can be installed on a single system Disabled refuge Type B outstations Fire telephones Type A outstations Steward emergency telephones Type A outstations Roaming telephones Disabled toilet alarms.BenefitsStylish versatile and simple to navigate and control.Suitable for small or large systems - fully networkable.Monitored roaming telephone handsets - enables use with confidence.System configuration via SD card front panel or PC connection.Facilitates clear communication during an emergency event.Ideal for retro-fitting old star-wired systems.Quality built robust system.Activityfault log.Outstations including toilet alarms powered directly from the line - no local power needed.Any combination of outstation on one system.

GBP 1539.52
1

Baldwin Boxall CARE2 EVC Control Panel 4-way Stainless Steel C2CS4

Baldwin Boxall CARE2 EVC Control Panel 4-way Stainless Steel C2CS4

Baldwin Boxall CARE2 EVC Control Panel 4-way Stainless Steel C2CS4Care2 is a radial wired emergency voice communication system built to the high standard you expect from Baldwin Boxall. It is stylish versatile and easy to use and offers an alternative to our well-established loop-wired Omnicare range.Key FeaturesCARE2 is an all-in-one Emergency Voice Communication EVC system.Fully monitored and battery-backed 24 hours quiescent and three hours functional.Fully compliant to BS5839-92011. Assists companies with compliance to BS99992008.Remote units are wired in a radial star configuration using two core fire resisting enhancednon-enhanced cable.Fully networkable. Networked panels are wired in a loop configuration using 2 x two core fire resisting enhanced cable.In the event of a break in the network loop the system will continue to function.All outstations are powered from the line including the roaming telephone enclosure and disabled toilet alarms.Optional link to fire detection system prevents hoax disabled refuge calls C2CFPE required. Firefighter roaming telephones and toilet alarms remain active.Speech steered disabled refuge outstations.Full duplex speech firefighter and emergencysteward telephones.Any combination of the following outstations can be installed on a single system Disabled refuge Type B outstations Fire telephones Type A outstations Steward emergency telephones Type A outstations Roaming telephones Disabled toilet alarms.BenefitsStylish versatile and simple to navigate and control.Suitable for small or large systems - fully networkable.Monitored roaming telephone handsets - enables use with confidence.System configuration via SD card front panel or PC connection.Facilitates clear communication during an emergency event.Ideal for retro-fitting old star-wired systems.Quality built robust system.Activityfault log.Outstations including toilet alarms powered directly from the line - no local power needed.Any combination of outstation on one system.

GBP 1771.76
1

Baldwin Boxall Omnicare Type A Red Fire Telephone with Lock Door BVOCFL

Baldwin Boxall Omnicare Type A Red Fire Telephone with Lock Door BVOCFL

Baldwin Boxall Omnicare Type A Red Fire Telephone with Lock Door BVOCFLThe OmniCare system offers a choice of outstation units which can be wired on the same loop from the control panel. The BVOCFL red fire telephone unit is one of the options available on this versatile system.Fire telephones are used by fire officers and those responsible for the evacuation of a building during an emergency. They provide essential communication for those in control. When operated by opening the door of the enclosure the persons managing the evacuation at the control panel can immediately see the location of the caller as this is indicated on the panel. The fire officer at the telephone point can relay the situation and confirm if that area is clear of personnelpublic before moving to the next levelarea.The fire telephone is connected to the control panel in a loop circuit and can be included with disabled refuge outstations on the same panel if these are required. As an option the Omnicare system also has a combined outstation which includes both a fire telephone and a disabled refuge unit in the same enclosure.Key FeaturesProvides two-way full duplex speech communication.Self-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Red finish also available in stainless steel BVOCFSL.Slot lock door push catch version available BVOCF.Addressable unit.The enclosure contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple fire telephones is available via the operator at the control panel.All outstations are in a loop circuit from control panels.Surface mountable or flush mount with optional bezel.

GBP 576.98
1

Baldwin Boxall Omnicare Type A Stainless Steel Fire Telephone with Lock Door BVOCFSL

Baldwin Boxall Omnicare Type A Stainless Steel Fire Telephone with Lock Door BVOCFSL

Baldwin Boxall Omnicare Type A Stainless Steel Fire Telephone with Lock Door BVOCFSLThe OmniCare system offers a choice of outstation units which can be wired on the same loop from the control panel. The BVOCFSL fire telephone unit with stainless steel finish is one of the options available on this versatile system.Fire telephones are used by fire officers and those responsible for the evacuation of a building during an emergency. They provide essential communication for those in control. When operated by opening the door of the enclosure the persons managing the evacuation at the control panel can immediately see the location of the caller as this is indicated on the panel. The fire officer at the telephone point can relay the situation and confirm if that area is clear of personnelpublic before moving to the next levelarea.The fire telephone is connected to the control panel in a loop circuit and can be included with disabled refuge outstations on the same panel if these are required. As an option the Omnicare system also has a combined outstation which includes both a fire telephone and a disabled refuge unit in the same enclosure.Key FeaturesProvides two-way full duplex speech communication.Self-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Stainless steel finish also available in red BVOCFL.Slot lock door push catch version available BVOCFS.Addressable unit.The enclosure contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple fire telephones is available via the operator at the control panel.All outstations are in a loop circuit from control panels.Surface mountable or flush mount with optional bezel.Please note Stainless steel products are not intended for installation in humid areas.

GBP 799.25
1