191 results (0,15403 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

C-Tec BF319 Fire Alarm Control Panel Mains Key Switch

C-Tec FF396-2 FP10 10Z Fire Repeater Panel

C-Tec FPROK1 FosMeter-Pro Hearing Loop Test Kit

C-Tec FPROK1 FosMeter-Pro Hearing Loop Test Kit

C-Tec FPROK1 FosMeter-Pro Hearing Loop Test KitSigNET recommends all its induction loop systems are tested using a Fosmeter Pro Induction Loop Test Kit FPROK1. Designed to simplify the setup of an induction loop system to the latest version of BS EN 60118-4 Magnetic field strength in audio-frequency induction loops for hearing aid purposes the kit includes an FPRO Fosmeter Pro induction loop tester cw intuitive display and simple to follow test menus a calibrated signal generator cw pre-loaded test tones and a set of headphones.As well as checking the magnetic field strength of an induction loop system it also measures background noise frequency response metal compensation AND allows you to listen to the loop signal. The tester and signal generator are each powered by a 9V PP3 battery and both are supplied in protective canvas carrying cases.Key FeaturesA must-have accessory for all AFILSinstallers and service engineers.Simplifies the setup of an induction loop system to BS EN 60118-4 Magnetic field strength in audio-frequency induction loops for hearing aid purposes.Includes an FPRO Fosmeter Pro induction loop tester cw intuitive display and simple to follow test menus a calibrated FPROSG Signal Generator cw pre-loaded test tones voice and music samples and a set of HEAD1 headphones.Checks the magnetic field strength of an induction loop system and measures background noise frequency responseandmetal compensation.Loop listening circuitry allows subjective listening tests to be carried out using the headphones supplied.Powered from a 9V PP3 battery.Supplied in a protective canvas carrying case.Auto power-off function helps to preserve battery life.

GBP 551.70
1

C-Tec CFP708-4 8 Zone Conventional Fire Panel LPCB Approved

C-Tec CFP708-4 8 Zone Conventional Fire Panel LPCB Approved

C-Tec CFP 8 Zone Conventional Fire Panel LPCB Approved - CFP708-4LPCB certified to EN54-24 C-TECs CFP 8 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price. Supplied in an attractive flush or surface mountable plastic enclosure it includes two detector zones four conventional sounder circuits class change and alert inputs on-board fire and fault relays and combined keypadkey switch entry.A wide range of engineering functions are also provided including selectable zone delays coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided. Optional repeaters relay expansion boards and EN54-13 system compliance devices are also available.Key FeaturesThird-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board LPCB with optional EN54 part 13 compliance from the BSI.Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry.Manufactured by C-TEC in the UK.Two detector zone circuits.Four conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSU.Wide range of engineering functions including zone test coincidence zone delay and non-latching zones.Two on-board relays Fire and Fault.Two open-collector outputs Remote and Reset.Class change and alert inputs.Installer-friendly design.Attractive flush or surface mountable plastic lid and enclosure - no bezel required.Low 25mA quiescent current.Multiple indicators.System expansion connections provided for up to eight two-wire repeaters one CFP761 network card required per system optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.Space for two x 12V 3.3Ah VRLA batteries.Fully compatible with C-TECs ActiV range of conventional fire detectors.

GBP 208.82
1

C-Tec CFP702-4 2 Zone Conventional Fire Panel LPCB Approved

C-Tec CFP702-4 2 Zone Conventional Fire Panel LPCB Approved

C-Tec CFP 2 Zone Conventional Fire Panel LPCB Approved - CFP702-4LPCB certified to EN54-24 C-TECs CFP 2 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price. Supplied in an attractive flush or surface mountable plastic enclosure it includes two detector zones four conventional sounder circuits class change and alert inputs on-board fire and fault relays and combined keypadkey switch entry.A wide range of engineering functions are also provided including selectable zone delays coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided. Optional repeaters relay expansion boards and EN54-13 system compliance devices are also available.Key FeaturesThird-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board LPCB with optional EN54 part 13 compliance from the BSI.Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry.Manufactured by C-TEC in the UK.Two detector zone circuits.Four conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSU.Wide range of engineering functions including zone test coincidence zone delay and non-latching zones.Two on-board relays Fire and Fault.Two open-collector outputs Remote and Reset.Class change and alert inputs.Installer-friendly design.Attractive flush or surface mountable plastic lid and enclosure - no bezel required.Low 25mA quiescent current.Multiple indicators.System expansion connections provided for up to eight two-wire repeaters one CFP761 network card required per system optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.Space for two x 12V 3.3Ah VRLA batteries.Fully compatible with C-TECs ActiV range of conventional fire detectors.

GBP 130.25
1

C-Tec CFP 4 Zone Conventional Fire Panel LPCB Approved - CFP704-4

C-Tec CFP 4 Zone Conventional Fire Panel LPCB Approved - CFP704-4

C-Tec CFP 4 Zone Conventional Fire Panel LPCB Approved - CFP704-4LPCB certified to EN54-24 C-TECs CFP 4 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price. Supplied in an attractive flush or surface mountable plastic enclosure it includes two detector zones four conventional sounder circuits class change and alert inputs on-board fire and fault relays and combined keypadkey switch entry.A wide range of engineering functions are also provided including selectable zone delays coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided. Optional repeaters relay expansion boards and EN54-13 system compliance devices are also available.Key FeaturesThird-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board LPCB with optional EN54 part 13 compliance from the BSI.Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry.Manufactured by C-TEC in the UK.Two detector zone circuits.Four conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSU.Wide range of engineering functions including zone test coincidence zone delay and non-latching zones.Two on-board relays Fire and Fault.Two open-collector outputs Remote and Reset.Class change and alert inputs.Installer-friendly design.Attractive flush or surface mountable plastic lid and enclosure - no bezel required.Low 25mA quiescent current.Multiple indicators.System expansion connections provided for up to eight two-wire repeaters one CFP761 network card required per system optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.Space for two x 12V 3.3Ah VRLA batteries.Fully compatible with C-TECs ActiV range of conventional fire detectors.

GBP 148.46
1

C-Tec XFP510-32 XFP Repeater Panel 32 Zone

C-Tec XFP510-32 XFP Repeater Panel 32 Zone

C-Tec XFP510-32 XFP Repeater Panel 32 ZoneCan be used to repeat the functions of an XFP Main panel at remote parts of a site e.g. all potential fire service entrances. Offers all of the functions and controls of an XFP Main panel access levels 1 2 and 3. Includes an on-board fault relay. Requires its own dedicated Mains power and battery back-up supply.A maximum of eight XFP Repeaters can be connected to one non-networked XFP Main panel. Communication between the XFP Main panel and Repeater requires an AFP711 network driver card fitted as standard in all XFP510-32s available as an optional extra on Main XFP 32 Zone panels. Repeater network wired in 1.5 mm2 two-core screened fire resistant cable. Network length must not exceed 500 metres.Key FeaturesCan be used to repeat the functions of an XFP Main panel at remote parts of a site e.g. all potential fire service entrances.Offers all of the functions and controls of an XFP Main panel access levels 1 2 and 3.Includes an on-board fault relay.Requires its own dedicated Mains power and battery back-up supply.A maximum of eight XFP Repeaters can be connected to one non-networked XFP Main panel.Communication between the XFP Main panel and Repeater requires an AFP711 network driver card fitted as standard in all XFP510-32s available as an optional extra on Main XFP 32 Zone panels.Repeater network is non-redundant and wired in 1.5 mm2 two-core screened fire resistant cable. Network length must not exceed 500 metres.

GBP 433.36
1

C-Tec XFP510-16 XFP Repeater Panel 16 Zone

C-Tec XFP510-16 XFP Repeater Panel 16 Zone

C-Tec XFP510-16 XFP Repeater Panel 16 ZoneCan be used to repeat the functions of an XFP Main panel at remote parts of a site e.g. all potential fire service entrances. Offers all of the functions and controls of an XFP Main panel access levels 1 2 and 3. Includes an on-board fault relay. Requires its own dedicated Mains power and battery back-up supply.A maximum of eight XFP Repeaters can be connected to one non-networked XFP Main panel. Communication between the XFP Main panel and Repeater requires a CFP761 network driver card fitted as standard in all XFP510-16s available as an optional extra on Main XFP 16 Zone panels. Repeater network wired in 1.5 mm2 two-core screened fire resistant cable. Network length must not exceed 500 metres.Key FeaturesCan be used to repeat the functions of an XFP Main panel at remote parts of a site e.g. all potential fire service entrances.Offers all of the functions and controls of an XFP Main panel access levels 1 2 and 3.Includes an on-board fault relay.Requires its own dedicated Mains power and battery back-up supply.A maximum of eight XFP Repeaters can be connected to one non-networked XFP Main panel.Communication between the XFP Main panel and Repeater requires a CFP761 network driver card fitted as standard in all XFP510-16s available as an optional extra on Main XFP 16 Zone panels.Repeater network wired in 1.5 mm2 two-core screened fire resistant cable. Network length must not exceed 500 metres.

GBP 315.26
1

C-Tec SAP501ECA SAP Sprinkler Panel 1 Loop 16z CAST

C-Tec CFP704-2 CFP Two Wire 4 Zone AlarmSense Control Panel

C-Tec CFP704-2 CFP Two Wire 4 Zone AlarmSense Control Panel

C-Tec CFP Two Wire 4 Zone AlarmSense Control Panel - CFP704-2C-TECs LPCB certified two-wire CFP AlarmSense fire panel is designed to work with Apollos AlarmSense range of detectors call points sounders and beacons. Most conventional fire systems are designed to work with two pairs of wires per zone one pair for detection devices such as smoke detectors heat detectors and manual call points the other for alarm devices such as bells sounders or strobes. By using different voltage bands for quiescent and alarm states AlarmSense components can be connected to the same pair of supply wires.When powered and controlled by the CFP two-wire fire panel this reliable technology takes all the complexity out of fire alarm system design leading to quicker less expensive and more flexible installation. Indeed research shows an AlarmSense two-wire system can achieve a 20-25 reduction of labour over a standard four wire conventional system. AlarmSense devices are acceptable for BS 5839-1 and BS 5839-6 systems making them particularly useful for fire protection in Houses of Multiple Occupation HMOs.Key FeaturesLPCB certified to EN54 parts 2 and 4Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry to access level 22 4 or 8 AlarmSense zone circuits dependent on model purchasedFour conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSUWide range of engineering functions including zone test coincidence zone delay and non- latching zonesTwo on-board relays Fire and FaultTwo open-collector outputs Remote and ResetClass change and alert inputsInstaller-friendly design accommodates easy first fix and straightforward maintenanceAttractive flush or surface mountable plastic lid and enclosure - no bezel requiredLow quiescent currentMultiple indicatorsEnd of line units included one per zoneAncillary system expansion connections provided for up to eight two-wire repeaters one CFP761 network driver card required per system and optional CFP relay boardsSpace for two x 12V 3.3Ah VRLA batteries

GBP 226.68
1

C-Tec CFP Two Wire 2 Zone AlarmSense Control Panel - CFP702-2

C-Tec CFP Two Wire 2 Zone AlarmSense Control Panel - CFP702-2

C-Tec CFP Two Wire 2 Zone AlarmSense Control Panel - CFP702-2C-TECs LPCB certified two-wire CFP AlarmSense fire panel is designed to work with Apollos AlarmSense range of detectors call points sounders and beacons. Most conventional fire systems are designed to work with two pairs of wires per zone one pair for detection devices such as smoke detectors heat detectors and manual call points the other for alarm devices such as bells sounders or strobes. By using different voltage bands for quiescent and alarm states AlarmSense components can be connected to the same pair of supply wires.When powered and controlled by the CFP two-wire fire panel this reliable technology takes all the complexity out of fire alarm system design leading to quicker less expensive and more flexible installation. Indeed research shows an AlarmSense two-wire system can achieve a 20-25 reduction of labour over a standard four wire conventional system. AlarmSense devices are acceptable for BS 5839-1 and BS 5839-6 systems making them particularly useful for fire protection in Houses of Multiple Occupation HMOs.Key FeaturesLPCB certified to EN54 parts 2 and 4Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry to access level 22 4 or 8 AlarmSense zone circuits dependent on model purchasedFour conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSUWide range of engineering functions including zone test coincidence zone delay and non- latching zonesTwo on-board relays Fire and FaultTwo open-collector outputs Remote and ResetClass change and alert inputsInstaller-friendly design accommodates easy first fix and straightforward maintenanceAttractive flush or surface mountable plastic lid and enclosure - no bezel requiredLow quiescent currentMultiple indicatorsEnd of line units included one per zoneAncillary system expansion connections provided for up to eight two-wire repeaters one CFP761 network driver card required per system and optional CFP relay boardsSpace for two x 12V 3.3Ah VRLA batteries

GBP 182.66
1

C-Tec CFP708-2 CFP Two Wire 8 Zone AlarmSense Control Panel

C-Tec CFP708-2 CFP Two Wire 8 Zone AlarmSense Control Panel

C-Tec CFP Two Wire 8 Zone AlarmSense Control Panel - CFP708-2C-TECs LPCB certified two-wire CFP AlarmSense fire panel is designed to work with Apollos AlarmSense range of detectors call points sounders and beacons. Most conventional fire systems are designed to work with two pairs of wires per zone one pair for detection devices such as smoke detectors heat detectors and manual call points the other for alarm devices such as bells sounders or strobes. By using different voltage bands for quiescent and alarm states AlarmSense components can be connected to the same pair of supply wires.When powered and controlled by the CFP two-wire fire panel this reliable technology takes all the complexity out of fire alarm system design leading to quicker less expensive and more flexible installation. Indeed research shows an AlarmSense two-wire system can achieve a 20-25 reduction of labour over a standard four wire conventional system. AlarmSense devices are acceptable for BS 5839-1 and BS 5839-6 systems making them particularly useful for fire protection in Houses of Multiple Occupation HMOs.Key FeaturesLPCB certified to EN54 parts 2 and 4Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry to access level 22 4 or 8 AlarmSense zone circuits dependent on model purchasedFour conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSUWide range of engineering functions including zone test coincidence zone delay and non- latching zonesTwo on-board relays Fire and FaultTwo open-collector outputs Remote and ResetClass change and alert inputsInstaller-friendly design accommodates easy first fix and straightforward maintenanceAttractive flush or surface mountable plastic lid and enclosure - no bezel requiredLow quiescent currentMultiple indicatorsEnd of line units included one per zoneAncillary system expansion connections provided for up to eight two-wire repeaters one CFP761 network driver card required per system and optional CFP relay boardsSpace for two x 12V 3.3Ah VRLA batteries

GBP 272.59
1

C-Tec EP203 3 Zone Automatic Extinguisher Panel LPCB Certified - EP203

C-Tec EP203 3 Zone Automatic Extinguisher Panel LPCB Certified - EP203

C-Tec EP203 3 Zone Automatic Extinguisher Panel LPCB Certified - EP203The EP203 three zone automatic extinguisher panel has been specifically designed for use in areas housing expensive dangerous or irreplaceable items of equipment. Third-party approved by the LPCB to EN 12094-1 the European standard for Fixed Firefighting Systems - Components for Gas Extinguishing Systems and EN54 parts 2 and 4 the panel epitomises quality durability and reliability.Featuring an intuitive 128 x 64 pixel two-colour graphic display that gives clear and concise feedback to the user installer and commissioning engineer the panel also includes six monitored inputs including hold and abort a time stamped log adjustable flood times and volt-free changeover relays for fire local fire 1st stage active 2nd stage active extractor fan and fault.The panel is supplied in an elegantly styled durable enclosure with all of its electronics - apart from its powerful 3A EN54-4 switch mode PSU - mounted on a detachable metal bridge plate for ease of installation. A wide range of ancillaries are also available including remote status units hold-off and abort buttons line terminators and output expansion relay boards.Key FeaturesThird-party LPCB certificated to EN 12094 part 1 and EN54 parts 2 and 4Functions as a standard three zone fire panel with additional circuitry for controlling the release of fire-suppressing gas into protected areasUnique 128 x 64 pixel graphical display facilitates straightforward system programmingAny combination of activated zones can be programmed to automatically start the panels extinguishant release sequenceIncludes a pull-down front-panel manual release button and two keyswitches for accessing the panels functions and toggling between automanual modeThree conventional sounder circuits two x 1st stage one x 2nd stagePowerful 3A EN54-4 compliant switch mode PSULow quiescent current - less than 40mA on mains failWide range of monitored inputs and auxiliary outputs see schematicAbort and hold inputs allow the panels release sequence to be cancelled or suspended at any timeTime-stamped event logRS485 connections for up to eight flush or surface remote status units with their own LCDs manual release and mode automanual switches. Single gang economy status units without an LCD are also available.Extensive range of commissioning and engineering functionsOptional relay expansion boards and single gang abort and hold buttonsIdeal for use in computer rooms telecommunication centres archive storage areas chemical plants generator rooms museums etc..System line terminator included with all panels

GBP 399.43
1

C-Tec ZFP2X Standard 2 Loop Touchscreen Panel with Blank Module

C-Tec ZFP2X Standard 2 Loop Touchscreen Panel with Blank Module

C-Tec ZFP Standard 2 Loop Touchscreen Panel with Blank ModuleCreated with the input of some of the worlds leading fire alarm and life safety experts the ZFP is the powerful touchscreen controlled fire alarm panel that everyones been waiting for.Designed and built in the UK the panel can be configured to suit any application. From small one out all out systems to large multi-loop networked systems with sophisticated cause and effects the ZFP can handle them all with ease.Simply tap the option you require and away you go. Whether youre the responsible person on site the installer the commissioning engineer or the emergency services you can access the information you require quickly and easily - all at the touch of a virtual button.Creating a sophisticated fire alarm system for an airport hospital university tower block hotel football stadium or other large building is just a few steps up from establishing a simple one out all out system for a small factory unit.All this and full compliance with EN54 parts 2 and 4 means that the ZFP is rapidly becoming the fire panel of choice for the fire industry worldwide.Key FeaturesCertified to EN54 parts 2 and 4 by Intertek.Apollo XP95Discovery protocol.Attractive 450 x 462 x 127mm cabinet medium and large sized cabinets also available.Up to 4 loops per panel 6 to 8 loops available in medium and large sized cabinets.Up to 64 eight-loop peer to peer panel network capacity.Hi-integrity and singlepath networking options.Very flexible cause and effects.Wide range of Switch Indicator modules.Multiple A-Bus expansion PCBs IO Units Relays etc.User-friendly full colour touchscreen with dynamic buttons and virtual QWERTY keyboard.Up to 100 separate and programmable zonal LEDs 200 on medium and large sized cabinets.10000 programmable and indicatable detection zones.Up to 38 characters of custom text per loop device.Automatic daylight saving BSTGMT mode.20000 event memory filterable by fire fault date.Non-fire supervisory event functionality.Optional thermal printers.Well-designed cabinets with easily removable electronics chassis.20-way heavy-duty brass earth bar as standard.72-hour standby 30 min alarm in standard cabinets.Built-in loop status current-reading.Powerful engineering and commissioning functions including SafeMode and DeviceManager.Attractive Compact Controllers.Wide range of flush-fit bezels and attractive glazed stainless steel framesFULLY compatible with C-TEC manufactured addressable ancillaries Hush Buttons Sounders Voice Sounders and BeaconsPowerful and intuitive PC programming toolsWide range of supported languages

GBP 1458.20
1