28 results (0,16320 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

C-Tec BF360BOX Ancillary Fire Alarm Equipment Box

C-Tec BF362BOX Ancillary Fire Alarm Equipment Box

C-Tec BF361BOX Ancillary Fire Alarm Equipment Box

C-Tec BF367 Auxiliary Device Isolator single gang

C-Tec BF367 Auxiliary Device Isolator single gang

BF367 Auxiliary Device Isolator single gangThe BF367 allows a 24V d.c. output from a fire alarm control panel to be remotely isolated to prevent external equipment such as auto diallers roller shutter doors etc from operating. This is a particularly useful function during routine test and maintenance as it safeguards against the inadvertent and potentially hazardous triggering of auxiliary equipment.To aid location the BF367s front label has a white write on panel allowing installers to add their own personalised text such as equipment locations. The unit will fit on 25mm deep flush or surface mount back boxes.Key FeaturesThe BF367 incorporates an isolating key switch and a high intensity amber LEDThe switch circuit has been designed so that if monitoring is used on the 24V d.c. output being controlled a fault condition will show at the fire panel when the BF367s key switch is in the ISOLATED position note that the key can be removed from the key switch in both the ON and ISOLATED positionsThe units amber LED can also be set-up to illuminate when the key switch is in the ISOLATED position provided sufficient voltage is presentAllows a 24 VDC output from a fire alarm control panel to be remotely isolated to prevent autodiallers water sprinklers rollershutters etc. from activatingDesigned so that if monitoring is used on the 24 VDC output being controlled a fault condition will show at the fire panel when the device is IsolatedLabel includes a white write on area allowing installers to add equipment locationsFits on standard UK 25mm flush or surface mount back boxes

GBP 21.18
1

C-Tec BF318 Remote LED Indicator Single Gang

C-Tec NC883D Conventional 12V Relay Unit

C-Tec OP-6510 PA Through Screen Speech Transfer System With Tactile Pad - English

C-Tec DFL1001100 Fire Alarm Log Book

C-Tec PDA7SD 500m2 Free-Standing Hearing Loop Amplifier 7.5A

C-Tec BF560-24 Switch Mode 24v 1.5A EN54-4 Boxed PSU

C-Tec PDA11SW 1000m2 Wall-Mounting Hearing Loop Amplifier 11A

C-Tec PDA5SD 200m2 Free-Standing Hearing Loop Amplifier 4.75A

C-Tec PDA5SW 200m2 Wall-Mounting PDAS Hearing Loop Amplifier 4.75A

C-Tec PDA7SW 500m2 Wall-Mounting Hearing Loop Amplifier 7.5A

C-Tec PDA11SD 1000m2 Free-Standing Hearing Loop Amplifier 11A

C-Tec BF3593S Stainless Steel Glazed Enclosure

C-Tec 24V 5A EN54-4 Switch Mode PSU BF562-5

C-Tec BF562-1 Switch Mode 24v 1.5A EN54-4 Boxed Metal PSU

C-Tec BF562-1 Switch Mode 24v 1.5A EN54-4 Boxed Metal PSU

C-Tec BF562-1 Switch Mode 24v 1.5A EN54-4 Boxed Metal PSUThe BF562-1 is certified to EN54-4A2 by the LPCB and VdS AFNOR pending. It comes with a plastic cover on PSU PCB which guards against touching live parts. Includes a single-pole voltfree changeover relay that switches for any fault condition.Key FeaturesMultiple indicators - supply present general fault fault type aux. equipment faultTwo selectable battery charge currentsBattery fault impedance limits can be optimised to suit load current helps extend battery lifeMains fail simulation modeImproved on-board temperature sensor with optional remote sensorElectronic functions comply with EN50131-6 grades 1-4 for security applicationsBF562-1E caged BF562-1C PCB-only versions availableTYPICAL USESIdeal for poweringbeam detectors auto-dial communicators aspirating smoke detectors auto-open vent systems auxiliary sounder systems or any other device performing a mandatory function of a fire alarm system.PSU CUSTOMISATIONThe BF562-1can be customised to suit your exact requirements using a BF423 configurator PC. Configurable parameters include float voltage temperature compensation battery charge rate mA battery impedance and configurableInputOutput settings. It is important to note changing the PSUs parameters in this way isoutside the scope of EN54-4 and any changes mustbe tested by the responsible person for correctoperation.PSU STATUS LEDlocated on the PSU PCB1 flash Mains Failure.2 flashes Battery Voltage Low.3 flashes Battery Voltage Critical.4 flashes Charger Failure.5 flashes Charger OK Battery is either actively charging or in float charge.6 flashes No Batteries Fitted indicating DIP Switch 4 position.7 flashes Battery Resistance Fault Level set by DIP Switch 2 position.8flashes Output Over Voltage.BATTERY FAULT MONITORINGThe BF562-1 complies with EN54-4A2 and therefore must monitor battery resistance. The fault threshold is directly related to the ability of the battery to deliver the rated current to the load. For example batteries stored uncharged for long periods during shipment andor distribution degrade leading to increased internal resistance. If a degraded battery is fitted a fault will be shown by the PSU as mandated by EN54-4A2.DATA PORTData on the BF562-1s status can be extracted from the PSUsbi-directional data port. The data availableincludes thermistor measurements battery terminal voltage system voltage at load terminals battery charge current load current battery impedanceandASCII text string status messages. Extracting this data requires additional equipment and permissions - contact C-TEC for details.

GBP 155.72
1

C-Tec APQL Line Level Jack Plate 6.35mm

C-Tec APQL Line Level Jack Plate 6.35mm

C-Tec APQL Line Level Jack Plate 6.35mmThe Outreach Plate audio input extension system comprises a range of wall ceiling and desk mountable plates specifically designed to increase the audio input capability of any audio system. Covering the most common variants of audio connectors they work by mixing the signals from various audio input sources into a single balanced line level input on a compatible amplifier. Each input plate features a built-in mixer preamp input level control and balanced output.Typically up to 10Outreach plates any mix can be daisy-chained to one balanced line level connection with cable lengths up to 100m easily achievable using standard two-pair audio cable i.e. Belden 8723. Each plate requires four wires two balanced line LineA LineA one ground GND and one power connection V 12-32V d.c..Most of C-TECs PDA Range induction loop amplifiers are fitted with an Outreach connection socket as standard. For audio systems that do not have an Outreach socket straightforward network connection can be achieved using an APV 24V 250mA d.c. regulated power supply and an APXO 3 pin XLR balanced line output plate.Key FeaturesAccepts 6.35mm 14 jack feeds from audio equipment such as stage or church mixing desks etc.Part of C-TECs patented Outreach Plate audio input extension system.Compatible with C-TECs entire range of PDA102 200E Pro-Rangeand ML1 induction loop amplifiers.Can be connected to any third-party audio or induction loop amplifier using an APV 24V 250mA power supply.Mounts on a 25mm standard UK single gang back box.

GBP 49.57
1

C-Tec QT601-2 Quantec Controller

C-Tec QT601-2 Quantec Controller

C-Tec QT601-2 Quantec ControllerQuantec is a powerful yet easy to use addressable call system that helps ensure vital communication throughout a building. In environments where efficiency is paramount Quantec delivers helping save staff time minimising disturbance and improving the quality of patient customer or employee care. Whatever the application - be it a call system for a nursing home hospital hotel or leisure centre or a staff protection system for a high dependency unit prison factory shop school or council office - Quantec is the obvious choice.With its flexible call routing multiple call levels a unique data protocol that works down just two wires and a laptop programmable system controller Quantec can be tailored to suit the exact operational needs of any building. For example calls can be routed to different parts of a site at different times of the day and unanswered calls can be set to transfer to other areas after a pre-determined time. As well as a huge range of cost-effective call points ceiling pulls displays monitoring points sounders neck pendants and infrared transmitters the system includes a host of industry-leading features.The controller supplies power to and controls a Quantec Addressable Call System. Monitors all network devices and manages the routing and distribution of all calls. Provides connections for network wiring standby batteries a laptop for system programmingoptionalpagingDECT equipment anoptionalprinter orPC to run Quantecs QT707S Surveyor data management software.Key FeaturesIncludes a library of 40 pre-set 45 custom place names.System setup requires a laptop PC running Quantecs QT707 programming tools.Can be semi-flush mounted using an QT385 bezel or fully-flushed using a BF3593S stainless steel enclosure.System wiring requires one or more QT603 network splitters.Wiring should be made in a spine and limb arrangement using 1.5 to 2.5mm2 TE spines and 4 to 8 core stranded security cable limbs.

GBP 426.65
1

C-Tec BF560-12 Switch Mode 12v 2A EN54-4 Boxed PSU

C-Tec BF560-12 Switch Mode 12v 2A EN54-4 Boxed PSU

C-Tec BF560-12 Switch Mode 12v 2A EN54-4 Boxed PSUThe C-Tec BF560-12 12V 2A EN54-4 Switch Mode PSU is ideal for connecting to 12V security STUs to provide BS5839-1 compliant remote monitoring facilities. It is certified to EN54-4A2 by the LPCB VdS AFNOR pending.Key FeaturesMultiple indicators - supply present general fault fault type aux. equipment fault.Two selectable battery charge currents.Battery fault impedance limits can be optimised to suit load current helps extend battery life.Mains fail simulation mode.Improved on-board temperature sensor with optional remote sensor.Ideal for connecting to 12V security STUs to provide BS5839-1 compliant remote monitoring facilities.Electronic functions comply with EN50131-6 grades 1-4 for security applications.BF560-12E Caged BF560-12C PCB-only versions available.Plastic cover on PSU PCB guards against touching live parts.Includes a single-pole voltfree changeover relay that switches for any fault condition.Additional InformationPSU CUSTOMISATIONThe BF560-12can be customised to suit your exact requirements using a BF423 configurator PC. Configurable parameters include float voltage temperature compensation battery charge rate mA battery impedance and configurableInputOutput settings. It is important to note changing the PSUs parameters in this way isoutside the scope of EN54-4 and any changes mustbe tested by the responsible person for correctoperation.12V SECURITY STUUSED PURELY FOR FIRE ALARM SIGNALLINGThe BF560-12 can help combat an area of fire alarm system non-compliance that is often overlooked - their connection to remote monitoring centres via 12V security STUs or autodiallers. Firesystems that require such monitoring are typically connected to 12V security STUs. Unfortunately PSUs used to power these STUs normally only offer 12 hours standby are notconnected to a dedicated mains supply and do not include the features demanded by EN54-4 such as battery impedance monitoring temperature compensated charging CPR compliance etc. TheBF560-12 solves these problems by allowing the use of 12V STUs with a cost-effective EN54-4 compliant PSU thereby facilitating compliance with BS5839-1 or European equivalents. Tofurther assist this application an optional STU mounting plate is available for inside the BF560-12 order code BF360SP.PSU STATUS LEDlocated on the PSU PCB1 flash Mains Failure.2 flashes Battery Voltage Low.3 flashes Battery Voltage Critical.4 flashes Charger Failure.5 flashes Charger OK Battery is either actively charging or in float charge.6 flashes No Batteries Fitted indicating DIP Switch 4 position.7 flashes Battery Resistance Fault Level set by DIP Switch 2 position.8flashes Output Over Voltage.BATTERY FAULT MONITORINGThe BF560-12 complies with EN54-4A2 and therefore must monitor battery resistance. The fault threshold is directly related to the ability of the battery to deliver the rated current to the load. For example batteries stored uncharged for long periods during shipment andor distribution degrade leading to increased internal resistance. If a degraded battery is fitted a fault will be shown by the PSU as mandated by EN54-4A2.EN50131-6 POWER SUPPLIES FOR INTRUSION HOLD UP ALARMS CAPABILITYThe power supply inside the BF560-12 has all the electrical functions required to comply with EN50131-6 Grade 4which includes Grades 3 2 and 1. However the BF560-12s enclosure isnot designed to comply with the standardsrequirements totriggeranalarm if someone tries to force the box open. OEM security companies interested in utilising the BF560-12s PSUPCB inside their own EN50131-6 compliant tamper-resistant enclosures should contact our marketing departmentfor further detailson costs and approvals.DATA PORTData on the BF560-12s status can be extracted from the PSUsbi-directional data port. The data availableincludes thermistor measurements battery terminal voltage system voltage at load terminals battery charge current load current battery impedanceandASCII text string status messages. Extracting this data requires additional equipment and permissions -call C-TEC for details.

GBP 113.64
1

C-Tec PDA103R Small Room Hearing Loop Kit for Suspended Ceilings 50m2

C-Tec PDA103R Small Room Hearing Loop Kit for Suspended Ceilings 50m2

C-Tec PDA103R Small Room Hearing Loop Kit for Suspended Ceilings 50m2Hearing loop systems allow hearing impaired people to hear more clearly. Most hearing aids have a T or MT switch which allows them to pick up the electromagnetic field generated by a hearing loop system. The hearing aid converts this signal into a sound suited to its users specific hearing requirements.Any person with a hearing aid positioned within or near the loop can hear the loop signal by switching their hearing aid to the correct position allowing them to participate more effectively in general conversation ordering goods or services listening to public performances etc.Everything you need to create a high-quality hearing loop system for a room up to 50m2 7m x 7m. Ideal for small meeting rooms council chambers etc.where equipment needs be mounted above suspended ceilings etc.Key FeaturesPDA103 amplifier includes a 3.5mm microphone input for connectingthetiedesk mic. supplied a line level input and an outreach socket.Metal compensation controlhelps improve intelligibility in rooms with high metal contentAdjustable mic line level and outreach controls.Drive level control allows the amplifiers output stage to be set-up to suit the exact characteristics of the application.State-of-the-art audio processor features an automatic gain control which compensates for poor microphone techniques and helps suppress loud noises hisses and clicks.Limit Peak Loop Fault and Power On indicatorsDesigned to be wall-mounted using the keyholes provided.Exceeds the requirements of BS7594 and EN60118-4 when correctly installed.Technical SpecificationHearing loop type wall mountable. Plug top mains lead supplied.Coverage 50m2 approx.Amplifier dimensions W135mm x H13mm x D35mm including controls. Weight 380g amplifier only.Kit box dimensions W340mm x H250mm x D70mm.Inputs 1 x 3.5mm mic. Socket 1 x 3.5mm line level socket 1 x Outreach socket.Indicators Limit Peak Loop Fault Power On.Controls Mic Line Outreach Metal Compensation Loop Drive Level.Kit Contains PDA103 amplifier PL1PSU1 plugtop power supply APM plated microphone 6m Belden cable 40m loop cable Hearing Loop Fitted sticker.

GBP 227.69
1

C-Tec EP203 3 Zone Automatic Extinguisher Panel LPCB Certified - EP203

C-Tec EP203 3 Zone Automatic Extinguisher Panel LPCB Certified - EP203

C-Tec EP203 3 Zone Automatic Extinguisher Panel LPCB Certified - EP203The EP203 three zone automatic extinguisher panel has been specifically designed for use in areas housing expensive dangerous or irreplaceable items of equipment. Third-party approved by the LPCB to EN 12094-1 the European standard for Fixed Firefighting Systems - Components for Gas Extinguishing Systems and EN54 parts 2 and 4 the panel epitomises quality durability and reliability.Featuring an intuitive 128 x 64 pixel two-colour graphic display that gives clear and concise feedback to the user installer and commissioning engineer the panel also includes six monitored inputs including hold and abort a time stamped log adjustable flood times and volt-free changeover relays for fire local fire 1st stage active 2nd stage active extractor fan and fault.The panel is supplied in an elegantly styled durable enclosure with all of its electronics - apart from its powerful 3A EN54-4 switch mode PSU - mounted on a detachable metal bridge plate for ease of installation. A wide range of ancillaries are also available including remote status units hold-off and abort buttons line terminators and output expansion relay boards.Key FeaturesThird-party LPCB certificated to EN 12094 part 1 and EN54 parts 2 and 4Functions as a standard three zone fire panel with additional circuitry for controlling the release of fire-suppressing gas into protected areasUnique 128 x 64 pixel graphical display facilitates straightforward system programmingAny combination of activated zones can be programmed to automatically start the panels extinguishant release sequenceIncludes a pull-down front-panel manual release button and two keyswitches for accessing the panels functions and toggling between automanual modeThree conventional sounder circuits two x 1st stage one x 2nd stagePowerful 3A EN54-4 compliant switch mode PSULow quiescent current - less than 40mA on mains failWide range of monitored inputs and auxiliary outputs see schematicAbort and hold inputs allow the panels release sequence to be cancelled or suspended at any timeTime-stamped event logRS485 connections for up to eight flush or surface remote status units with their own LCDs manual release and mode automanual switches. Single gang economy status units without an LCD are also available.Extensive range of commissioning and engineering functionsOptional relay expansion boards and single gang abort and hold buttonsIdeal for use in computer rooms telecommunication centres archive storage areas chemical plants generator rooms museums etc..System line terminator included with all panels

GBP 399.43
1

C-Tec BF560-12E Switch Mode 12v 2A Caged PSU PCB

C-Tec BF560-12E Switch Mode 12v 2A Caged PSU PCB

C-Tec BF560-12E Switch Mode 12v 2A Caged PSU PCBTheBF560-12E is apowerful switch modedigital hybrid PSU that can be customised to suit your exact requirements. The plasticcoveron PSU PCB guards against touching live parts to VDE 0100-410. Includes the same electronics as the BF560-12 LPCBcertified EN54-4A2 boxed 12V 2A PSU.Key FeaturesMetal base platefacilitatesstraightforwardmountinginside third-party OEMenclosures.Includes a single-pole voltfree changeover relay that switches for any fault condition.Includes afault type hazardous voltages present LED.Two selectable battery charge currents.Battery fault impedance limits can be optimised to suit load current helps extend battery life.Mains fail simulation mode.Improved on-board temperature sensor with optional remote sensor.Electronic functions comply with EN50131-6 grades 1-4 for security applications.Additional InformationEN50131-6 POWER SUPPLIES FOR INTRUSION HOLD UP ALARMS CAPABILITYThe BF560-12E has all the electrical functions required to comply with EN50131-6 Grade 4which includes Grades 3 2 and 1. OEM security companies interested in utilising the BF560-12E inside their own EN50131-6 compliant tamper-resistant enclosures should contact our marketing departmentfor further detailson costs and approvals.PSU CUSTOMISATIONThe BF560-12Ecan be customised to suit your exact requirements using a BF423 configurator PC. Configurable parameters include float voltage temperature compensation battery charge rate mA battery impedance and configurableInputOutput settingsPSU STATUS LEDlocated on the PSU PCB1 flash Mains Failure.2 flashes Battery Voltage Low.3 flashes Battery Voltage Critical.4 flashes Charger Failure.5 flashes Charger OK Battery is either actively charging or in float charge.6 flashes No Batteries Fitted indicating DIP Switch 4 position.7 flashes Battery Resistance Fault Level set by DIP Switch 2 position.8flashes Output Over Voltage.BATTERY FAULT MONITORINGThe BF560-12E monitors battery resistance to the requirements of EN54-4A2. The fault threshold is directly related to the ability of the battery to deliver the rated current to the load. For example batteries stored uncharged for long periods during shipment andor distribution degrade leading to increased internal resistance. If a degraded battery is fitted a fault will be shown by the PSU as mandated by EN54-4A2.DATA PORTData on the BF560-12Es status can be extracted from the PSUsbi-directional data port. The data availableincludes thermistor measurements battery terminal voltage system voltage at load terminals battery charge current load current battery impedanceandASCII text string status messages. Extracting this data requires additional equipment and permissions - contact C-TEC for details.

GBP 70.52
1