51 results (0,14220 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

C-Tec FPROK1 FosMeter-Pro Hearing Loop Test Kit

C-Tec FPROK1 FosMeter-Pro Hearing Loop Test Kit

C-Tec FPROK1 FosMeter-Pro Hearing Loop Test KitSigNET recommends all its induction loop systems are tested using a Fosmeter Pro Induction Loop Test Kit FPROK1. Designed to simplify the setup of an induction loop system to the latest version of BS EN 60118-4 Magnetic field strength in audio-frequency induction loops for hearing aid purposes the kit includes an FPRO Fosmeter Pro induction loop tester cw intuitive display and simple to follow test menus a calibrated signal generator cw pre-loaded test tones and a set of headphones.As well as checking the magnetic field strength of an induction loop system it also measures background noise frequency response metal compensation AND allows you to listen to the loop signal. The tester and signal generator are each powered by a 9V PP3 battery and both are supplied in protective canvas carrying cases.Key FeaturesA must-have accessory for all AFILSinstallers and service engineers.Simplifies the setup of an induction loop system to BS EN 60118-4 Magnetic field strength in audio-frequency induction loops for hearing aid purposes.Includes an FPRO Fosmeter Pro induction loop tester cw intuitive display and simple to follow test menus a calibrated FPROSG Signal Generator cw pre-loaded test tones voice and music samples and a set of HEAD1 headphones.Checks the magnetic field strength of an induction loop system and measures background noise frequency responseandmetal compensation.Loop listening circuitry allows subjective listening tests to be carried out using the headphones supplied.Powered from a 9V PP3 battery.Supplied in a protective canvas carrying case.Auto power-off function helps to preserve battery life.

GBP 551.70
1

C-Tec FiTT EVC Line Tester

C-Tec FPROSG Calibrated Audio Signal Generator

C-Tec BF319 Fire Alarm Control Panel Mains Key Switch

C-Tec BF370R KAC Red Surface Mounting Crack Glass Fire Call Point

C-Tec DFL1001100 Fire Alarm Log Book

C-Tec BF370W KAC Red IP67 Waterproof Crack Glass Fire Call Point

C-Tec QT421 Quantec RF Integrity Transmitter

C-Tec QT422RX Quantec Mk2 Radio Receiver

C-Tec CA454AW CA Base Voice Sounder - White

C-Tec BF325 Alert Buddy Kit

C-Tec CFP 4 Zone Conventional Fire Panel LPCB Approved - CFP704-4

C-Tec CFP 4 Zone Conventional Fire Panel LPCB Approved - CFP704-4

C-Tec CFP 4 Zone Conventional Fire Panel LPCB Approved - CFP704-4LPCB certified to EN54-24 C-TECs CFP 4 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price. Supplied in an attractive flush or surface mountable plastic enclosure it includes two detector zones four conventional sounder circuits class change and alert inputs on-board fire and fault relays and combined keypadkey switch entry.A wide range of engineering functions are also provided including selectable zone delays coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided. Optional repeaters relay expansion boards and EN54-13 system compliance devices are also available.Key FeaturesThird-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board LPCB with optional EN54 part 13 compliance from the BSI.Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry.Manufactured by C-TEC in the UK.Two detector zone circuits.Four conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSU.Wide range of engineering functions including zone test coincidence zone delay and non-latching zones.Two on-board relays Fire and Fault.Two open-collector outputs Remote and Reset.Class change and alert inputs.Installer-friendly design.Attractive flush or surface mountable plastic lid and enclosure - no bezel required.Low 25mA quiescent current.Multiple indicators.System expansion connections provided for up to eight two-wire repeaters one CFP761 network card required per system optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.Space for two x 12V 3.3Ah VRLA batteries.Fully compatible with C-TECs ActiV range of conventional fire detectors.

GBP 148.46
1

C-Tec CFP702-4 2 Zone Conventional Fire Panel LPCB Approved

C-Tec CFP702-4 2 Zone Conventional Fire Panel LPCB Approved

C-Tec CFP 2 Zone Conventional Fire Panel LPCB Approved - CFP702-4LPCB certified to EN54-24 C-TECs CFP 2 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price. Supplied in an attractive flush or surface mountable plastic enclosure it includes two detector zones four conventional sounder circuits class change and alert inputs on-board fire and fault relays and combined keypadkey switch entry.A wide range of engineering functions are also provided including selectable zone delays coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided. Optional repeaters relay expansion boards and EN54-13 system compliance devices are also available.Key FeaturesThird-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board LPCB with optional EN54 part 13 compliance from the BSI.Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry.Manufactured by C-TEC in the UK.Two detector zone circuits.Four conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSU.Wide range of engineering functions including zone test coincidence zone delay and non-latching zones.Two on-board relays Fire and Fault.Two open-collector outputs Remote and Reset.Class change and alert inputs.Installer-friendly design.Attractive flush or surface mountable plastic lid and enclosure - no bezel required.Low 25mA quiescent current.Multiple indicators.System expansion connections provided for up to eight two-wire repeaters one CFP761 network card required per system optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.Space for two x 12V 3.3Ah VRLA batteries.Fully compatible with C-TECs ActiV range of conventional fire detectors.

GBP 130.25
1

C-Tec BF366 Isolatable Relay on a Plate 24v 5A

C-Tec BF366 Isolatable Relay on a Plate 24v 5A

C-Tec BF366 Isolatable Relay on a Plate 24v 5AThe BF366 is a double-pole 24V 5A polarised relay specifically designed for use in 24V fire alarm systems. It includes a key switch isolation facility allowing the relay operation to be temporarily disabled from the fire alarm signal during routine test and maintenance to prevent auto diallers water sprinklers roller shutters etc. from activating.Mountable on a 25mm flush or surface mount back box the relay is trigger able via a control panels open collector output or a standard polarised fire alarm sounder circuit. If connecting to a sounder circuit note that the relay will return to its normal state when the fire condition is cleared or silenced. Check with the approving authority that the proposed arrangement is acceptable prior to installation.Key FeaturesA 24V 5A polarised relay designed for use in 24V fire alarm systemsIncludes a keyswitch isolation facility allowing the relay operation to be temporarily disabled during routine test and maintenance to prevent auto diallers water sprinklers roller shutters etc. from activatingWhen isolated the units Isolated LED will flash and a warning beeper will sound every 8 seconds to ensure devices are not inadvertently left in the isolated stateRelay is triggerable via a control panels open collector output or a standard polarised fire alarm sounder circuit if connecting to a sounder circuit the relay will return to its normal state when the fire condition is cleared or silenced - check with the approving authority that this arrangement is acceptable prior to installationFits on standard UK 25mm flush or surface mount back boxes

GBP 23.32
1

C-Tec CFP708-4 8 Zone Conventional Fire Panel LPCB Approved

C-Tec CFP708-4 8 Zone Conventional Fire Panel LPCB Approved

C-Tec CFP 8 Zone Conventional Fire Panel LPCB Approved - CFP708-4LPCB certified to EN54-24 C-TECs CFP 8 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price. Supplied in an attractive flush or surface mountable plastic enclosure it includes two detector zones four conventional sounder circuits class change and alert inputs on-board fire and fault relays and combined keypadkey switch entry.A wide range of engineering functions are also provided including selectable zone delays coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided. Optional repeaters relay expansion boards and EN54-13 system compliance devices are also available.Key FeaturesThird-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board LPCB with optional EN54 part 13 compliance from the BSI.Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry.Manufactured by C-TEC in the UK.Two detector zone circuits.Four conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSU.Wide range of engineering functions including zone test coincidence zone delay and non-latching zones.Two on-board relays Fire and Fault.Two open-collector outputs Remote and Reset.Class change and alert inputs.Installer-friendly design.Attractive flush or surface mountable plastic lid and enclosure - no bezel required.Low 25mA quiescent current.Multiple indicators.System expansion connections provided for up to eight two-wire repeaters one CFP761 network card required per system optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.Space for two x 12V 3.3Ah VRLA batteries.Fully compatible with C-TECs ActiV range of conventional fire detectors.

GBP 208.82
1

C-Tec KAC Red No Break Surface Mounting Fire Call Point BF370MR

C-Tec CA457AW CA C Class Base Voice Sounder VAD - White