31 results (0,16433 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Cooper CFEAPULLKIT Toilet Alarm Full Kit including PSU

Cooper LP800KIT Loop Tester Kit

Cooper Menvier CFEAODI Emergency Assist Over Door Indicator

Cooper EAA16-LS Toilet Alarm Outstation Master - Light Grey - Surface Mount

Cooper Menvier CFEACORD Emergency Assist Pull Cord Accessory Pack

Cooper Menvier MDS824COV Sounder Cover Plates

Cooper EC0232 Lon to RS232 Adapter

Cooper FXROLPWR Wall VADSounder - Red

Cooper FXN824 Conventional Base Sounder

Cooper CAPT340 Intelligent Addressable Photo Thermal Sensor MAOH850 FNX722 400004FIRE-0004X

Cooper MCOM Micro Single Channel Output Unit recognised as a output unit

Cooper MCOM-R Micro Single Channel Output Unit 5 second reset pulse

Cooper FXSOLCWS Ceiling VAD White Shallow Base

Cooper MCOM-S Micro Single Channel Output Unit recognised as a sounder

Cooper FXSOLWRS Wall VAD Red Shallow Base

Cooper FXSOLWRD Wall VAD Red Deep Base

Cooper Menvier EFDAU500 Compact Wall Mounted Voice Alarm System

Cooper Menvier EFDAU500 Compact Wall Mounted Voice Alarm System

Cooper Menvier EFDAU500 Compact Wall Mounted Voice Alarm SystemThe networked voice alarm and public address system Compact DAU500 is based on the concept of a standalone or decentralised network topology with multi-channel amplifier and built-in local power backup. This state-of-the-art digital technology offers an audio distribution system which is a compact all-in-one wall-mounted solution where a flexible and easy to operate voice system installation.Compact DAU500 can be configured as a standalone or networked voice alarm system comprising of 6 loudspeaker circuits and consists of a central control unit with embedded amplifier cards 3 dual-channel amplifier cards EF-DA200 for 6 zones plus one dual-channel amplifier EF-DA200 for active back-up with integrated emergency power manager in accordance with EN54-4.Compact DAU500 is an optimised voice alarm andor public address system designed for small and medium sized applications. A standalone central control unit together with three EF-DA200 two channel amplifiers forms a complete voice alarm system for venues such as schools smaller hotels etc. The overall system achieves the performance requirements for voice alarm systems in accordance with EN54-16 and electro-acoustic emergency warning systems EN 50849.The Compact DAU500 central control unit has a built-in EN54-4 certified power supply equipment complete with 4 ampere intelligent charger and battery compartment.Each DAU500 panel supports memory storage for 22 pre-recorded messages of max. 5 minutes each they can be configured for alarm messages and signals evacuation alarm warning siren and attention signals siren chime. The volume of each source and each amplifier channel can be regulated using the 5-point parametric audio filter which is available for each input and output. Faults are recognized displayed and logged in compliance with standards within a few seconds.The Compact DAU500 central unit features 2 analogue balanced inputs for background music or an external analogue priority signal that can trigger an evacuation status.As standard the DAU500 panel is equipped with 6 independent amplifier channels which can operate a total of 6 loudspeaker circuits each loaded with a maximum of 100W. Amplifier channels can be bridged in pairs creating more powerful loudspeaker lines each capable of driving a 200W loudspeaker load. It is also possible to mix branch and loop line technology on the same central control unit. The number of loudspeaker circuits can be further expanded using the EF-HEXAPOD6 multiplexer units for phased evacuation applications the maximum number of loudspeaker circuits possible from a single DAU500 panel is 18 lines this limit can be extended further to 36 loudspeaker lines in non-phased evacuation applications.The Compact DAU500 directs two live stream audio channels and a serial data channel RS422 into remote zones via a redundant global network loop and controls a 6-channel message player that sends synchronized audio signals to the local zones. In this way each Compact DAU500 can play multiple audio messages simultaneously in the local zones. All announcement memory modules are synchronized between several Compact DAU500 panels supporting a wide area of warning message playback.Key FeaturesCompatible charger for 24 V DC backup batteries according to national standardsBattery backup storage for 24V battery from 10Ah to 55Ah2 x global network ports RJ45 for redundant ring monitored3 x local network ports RJ45 for local IO devices monitored2 x BGM one reserved for the fire station in the front panel8 x GPI terminal block opto-isolated8 x GPO terminal block open collectorSecured potential-free relay output EVAC FAULT RESETSecure input RESET SILENCE 6 x EVACLocal message player with storage of 22 audio files total length 110 minutesUSB interfacePre-programmed and exchangeable microSD cardControl and display board national language optionalFire station with access protection level 220kHz AC end-of-line monitoring with impedance deviation measurement EOLLoop line technology with LoopDrive 54-17 certified6x 100W or 3x 200W bridged continuous powerClass D 100V outputsOutput power at 230V mains voltage 6 x 100WOutput power with 24V DC emergency power supply 6 x 100WFrequency response 50Hz to 20KHz 3dBDistortion factor 0.1 at 1 kHz sineSignal to noise ratio 90dB A - weightedChannel separation 80dBEfficiency at maximum performance 80

GBP 8409.46
1

Cooper NCDR Dual Redundant Network Card

Cooper NCDR Dual Redundant Network Card

Cooper NCDR Dual Redundant Network CardThe NCDR is the heart beat of the Cooper true Pier-to Pier fault tolerant network. It allows information from any Cooper input and output device to be passed over the network and display on any Cooper Addressable Fire panels or remote display such the Sire monitor or the Cooper Graphic Package. Information such as Fire General Alarm Pre-alarm Faults Disablement and status information from any panel is accessible on the Cooper Pier to Pier network thus allowing site wide cause and effect functionality.Simply by adding and connecting the NCDR network card allows any Cooper addressable Fire Alarm control Panel to be networked. All other panels on the network will be instantly aware of a panel as soon as it is given valid network address thus allowing additional panels to be added at any time with a minimum amount of re-programming. The NCDR dual channel serial gateway consists of two channels each using a FT3150 Smart transceiver and FT-X1 communication transformer.Each Neuron supports a serial 232 interface allowing the Master Neuron to communicate with the host equipment and also to send messages to and receive messages from the Slave Neuron. This allows nodes to communicate using 2 separate networks simultaneously thereby providing continuous communication in the event of open or short circuit faults on either network. Software prevents the duplication of messages. The network can be mounted inside the cooper addressable fire panels.

GBP 318.67
1

Cooper Menvier 400003FIRE-0003X Addressable Multi-Mode Heat Sensor

Cooper Menvier 400003FIRE-0003X Addressable Multi-Mode Heat Sensor

Cooper Menvier 400003FIRE-0003X Addressable Multi-Mode HeatSensorThis range of intelligent addressable sensors have been specificallydesigned to operate with Eatons intelligent addressable fire systems.All sensors are third party approved to the relevant sectionof EN54 part 7 for smoke detectors part 5 for heat detectors and part 17 forshort circuit isolators. The optical sensor CAP320 is suitable for most applicationsgiving the fastest response to slow burning or smouldering fires which giverise to large visible smoke particles.The photo-thermal sensor CAPT340 will respond quickly tofast clean burning fires yet maintain the advantage of optical sensors whendetecting smouldering fires The thermal enhancement of this sensor allows ahigher alarm threshold which provides a greater rejection of false alarms. Thesensor will also raise an alarm at temperatures exceeding 60C.The CAPT340 has daynight modes available programmable fromthe site installer software. The day mode uses the heat aspect of the sensorfor areas which may have smoky environments during for example working hours.The night mode uses a combination of A2S and smoke detection. If notprogrammed the sensor defaults to dual mode.The heat sensor CAH330 can be set to one of 3 modes 77C 92C and rate of rise. These sensors are designed to be used in environmentswhere the ambient conditions might cause false alarms if smoke detection wereto be used for example where there is a high level of dust fumes steam orsmoke under normal conditions.Key FeaturesSoft addressedIntegral short circuit isolatorSingle addressWide range of sensor types360 visibility LED using lightpipe technologyDrift compensation

GBP 34.94
1