290 results (0,15813 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Fireclass 2501234FC Conventional Manual Call Point with Plastic Element with Back Box

Fireclass 2501013FC Conventional Manual Call Point with Glass Element with Back Box

Fireclass 517.001.248FC DX070 Enclosure with 70mm DIN Rail

Fireclass 557.200.039FC TLI800ENG with PSU

Fireclass ROSHRDSRFC ROSHNI Sounder Complete with Deep Base Red

Fireclass 517.001.247FC DX170 Enclosure with 170mm DIN Rail

Fireclass 508.031.751FC MUB-RV Universal 5quot Base with Relay

Fireclass DPK6 Duct Probe with 4B-C 4quot Continuity Base

Fireclass DPK6 Duct Probe with 4B-C 4quot Continuity Base

Fireclass DPK6 Duct Probe with 4B-C 4 Continuity BaseThe DPK6 duct probe units have been developed to detect smoke in ventilation ducts and offer significant benefits in terms of performance and installation. For most applications smoke or combustion products are likely to have travelled some distance ageing the smoke prior to reaching the probe unit. It is therefore normally recommended that an optical smoke detector be fitted and this is often a requirement of building regulations. The DPK6 duct probe units use FC460PH Multi Sensor Smoke Detectors.The DPK6 Duct Probe units are not normally mounted directly inside ducts because the airflow only allows the detector to sample air from a small section of the duct and such detectors would rapidly become dirty. Instead ducting is protected by the use of probe units which gather air from a cross section of the duct and pass it through a smoke detector head.The system comprises only one single duct probe tube which improves efficiency and reduces installation time. The DPK6 duct smoke detector housing is designed to comply with the stringent demands of new European standard EN 54-27. The system fulfils all the requirements for safe fire detection with airflow speeds from 15 ms to 20 ms. For the airflow through the adaptor to be representative of the airflow in the ventilation duct the detector should be installed at a place where normally flow meters etc. are sited.Key FeaturesDPK6 for use with FC460PH with built-in 4B-C 4 continuity base.Designed to comply with EN 54-27.One-pipe air sampling system.Patented Cap-up Venturi pipe and duct housing.Test hole on cover.Simple installation.Sensitive flow indicator.Simple service and maintenance.Range of aluminium probe tubes are available for ducts up to 2700 mm.

GBP 134.30
1

Fireclass 516.016.016FC ProReact Analogue Controller with Display

Fireclass 516.016.016FC ProReact Analogue Controller with Display

Fireclass 516.016.016FC ProReact Analogue Controller with DisplayProReact Analogue Heat Detector system consists of a control module and four core detection cable designed to interface to a conventional fire alarm panel or DIM800 or DDM800 addressable module. The control module monitors the resistance of specially doped polymers within the sensor cable which change as a function of temperature. An abnormal change in resistance along the detection cable triggers either a Pre- Alarm or Alarm on the interface module.The system is intended to simplify system design and be uncomplicated and straightforward to install. Commissioning of the controller can be done using a laptop computer or through an optional built-in self-programming module. The sensor cable has been designed to be physically and electronically rugged to suite a range of environments with options for PVC Polypropylene or Nylon coatings or a strong stainless steel braid.The ProReact technology offers an alternative solution to heat protection in a wide range of applications and industries from power generation to oil and gas.Typical applicationsCar parksFactories processing plantsWarehousesCable traysConveyor beltsKey FeaturesAlarm Pre-Alarm temperature ranges from 54-100CProgrammable on-site adjustment of sensitivityUp to 500 m continuous lengthAlarm hot-spot length equal to 3 of zone lengthSeparate Alarm and Pre-alarm volt-free outputsNo nomograms or other scales to interpretSimple 3-Step InstallationAmbient temperature compensation maintains alarm temperature accuracySelf-Restorable after fire event up to 125CFlexible cable for easy mechanical installationReliable signalling of open and short circuit conditionsExtrusion and Braiding options to satisfy both mechanical and environmental conditions

GBP 650.09
1

Fireclass 516.016.024FC ProReact Analogue Cable With Additional Nylon Coating 500m

Fireclass 516.016.023FC ProReact Analogue Cable With Additional Nylon Coating 200m

Fireclass 516.016.022FC ProReact Analogue Cable With Additional Polypropylene Coating 500m

Fireclass 516.300.413FC FV413F Triple Infrared Flame Detector with NTSC Camera

Fireclass 516.300.413FC FV413F Triple Infrared Flame Detector with NTSC Camera

Fireclass 516.300.413FC FV413F Triple Infrared Flame Detector with NTSC CameraThe FV300 range uses Infra-Red Array based sensing technology to provide the ultimate programmable flame detector. An array of 256 infra-red sensors plus two optical channels view the protected area. Powerful algorithms running on a Digital Signal Processor DSP are tuned to the characteristics of a fire and analyse the signals from these channels to quickly and reliably identify fires. A key advantage of using an array is that the detector can accurately identify the location of the flame within the field of view.The location information is used to overlay a marker on the live video output to highlight the fire location. The user can quickly see the location of one fire or multiple fires and decide on the appropriate action. The location information is also available on the field network interface. User defined areas within the field of view can be masked and un-masked dynamically to improve reliability and maintain maximum coverage at all times.The detector can be supplied with an optional integral colour video camera to display a live image of the field of view this is in addition to the alarm location and status information which is available as standard on the video output.Key FeaturesAdvanced array-based detectorPowerful signal processing on DSP with algorithms to give reliable flame detectionDetection range Over 50 m for 0.1 m2n-heptane panfireField of view 90 horizontal 85 vertical with full range maintainedHigh immunity to false alarmsSolar blindMasking of areas in field of viewAutomatic optical path monitoringAdvanced self-test and service featuresBuilt-in video camera option View protected area with alarm location and status overlayIEC 61508 Approved SIL2

GBP 4983.64
1

Fireclass 20-118FC Combined Roshni Sounder Strobe Complete with Deep Base IP65 VID

Fireclass 516.016.025FC ProReact Analogue Cable with Additional Stainless Steel Braid - 200m

Fireclass 516.016.026FC ProReact Analogue Cable with Additional Stainless Steel Braid - 500m

Fireclass 516.016.224FC ProReact L Clip with Edge Clip - Zintec Pack of 100

Fireclass 514.800.805FC FC420CP-I Indoor Call Point with Isolator

Fireclass 514.800.805FC FC420CP-I Indoor Call Point with Isolator

Fireclass 514.800.805FC FC420CP-I Indoor Call Point with IsolatorA comprehensive range of call points for use with FireClass addressable systems using the robust and reliable FireClass open protocol. All the callpoints are designed to enable an alarm signal to be given by a plastic resettable element which means that the call point can be easily reset after it has been activated. Any change in the status of the switch is immediately communicated to the FireClass Control and Indicating Equipment CIE. All call points have an integral short-circuit isolator for monitoring the addressable loop wiring.The integral LED indicator is normally off. When the frangible element is broken an alarm is registered and the LED will illuminate red. If a section of the loop wiring adjacent to the call point is shorted the built-in short-circuit isolator trips isolating the shorted section and the LED is illuminated yellow. The status remains until the short is removed. If required an optional transparent hinged cover may be installed to guard against accidental operation. Both indoor and outdoor versions are available.FC420CP-I Addressable Indoor Call Point is designed to monitor and signal the condition of a switch contact that is operated by activating the deformable plastic element. A short circuit isolator is embedded.Key FeaturesIntegral Short Circuit IsolatorDual Colour LED IndicationEN54-11 CertificationCompact Modern StylingTest Key for Fast TestingIP67 Ingress Protection models for external applications

GBP 38.47
1