27 results (0,13443 seconds)

Brand

Gender

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Gent S4T-711-V S4 SELF TEST Dual Optical Heat Sensor amp Voice Sounder

Gent S4T-711-V S4 SELF TEST Dual Optical Heat Sensor amp Voice Sounder

Gent S4T-711-V S4 SELF TEST Dual Optical Heat Sensor Voice SounderThis device has a new IP21 external moulding new detector chamber design anda dual microprocessor PCB. This design delivers even better smoke detection andvoice storage capacity. In addition the award-winning Self-Test feature allows boththe heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Available in a large range of multi-sensorPart-23 VAD and sounder voice options. Enables discrete functional testing andvisual inspection of the fire alarm systemby reducing the engineer toolset to justa mobile device phone or tablet. Nomore impact on building occupiers. Tests both the heat and smokesensors by heating the thermistorand introducing small amounts ofsmoke into the detection chamber. Gently blows the smoke out of thedetection chamber and smoke entrypoints to ensure they are not blocked. Flexible testing options allow the engineerto test in different ways single devicedetection zone loops panels. Allows up to 6 devices to be tested atonce per loop and any number of loopscan be tested simultaneously makingthe functional testing incredibly fast. Device testing is fast enough to allowup to 4 functional tests to be performedper year for the lifespan of the device. Eliminates all access issues whendetector testing ensuring 100functional testing is achieved. Allows the system to remain active whilsttesting as each detector is only offline for60 seconds and outputs are not generated. Any fires detected outside of thedevices performing Self-Test will stopthe Self-Test process and operatethe fire systems Cause Effect. Allows the engineer to easily locatethe detector using the App and BLEto check the device number labelzone description and detector type. Allows simple device updates tobe performed through the Appincluding the correction of inaccuratedevice labels and loop mapping. The app and BLE handshakeverifies that the engineer has beenwithin visual inspection range. Optional Inspection prompt LEDs onthe device let the engineer know whatSelf-Test devices need to be visuallyinspected and will automatically turn offwhen the visual inspection is complete. Engineers can spend more time digitallycapturing non-compliance issues andadvising how to resolve them. Thisincludes any issues causing false alarms. Test Fire LED option in the App allowsthe fire LED to be tested a pendingBS5839-1 testing requirement. Thisfeature can additionally confirm thatthey are inspecting the correct device. The CLSS App allows the engineerto simulate a fire and test theCause Effect logic. The CLSS App also allows theCause Effect to be triggeredthrough a successful Self-Testoperation allowing a witness test tobe performed using real smoke.

GBP 190.24
1

Gent S4T-711-VAD-HPR S4 SELF TEST Dual Optical Heat Sensor amp High Power Red VAD

Gent S4T-711-VAD-HPR S4 SELF TEST Dual Optical Heat Sensor amp High Power Red VAD

Gent S4T-711-VAD-HPR S4 SELF TEST Dual Optical Heat Sensor High Power Red VADThis device has a new IP21 external moulding new detector chamber design anda dual microprocessor PCB. This design delivers even better smoke detection andvoice storage capacity. In addition the award-winning Self-Test feature allows boththe heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Available in a large range of multi-sensorPart-23 VAD and sounder voice options. Enables discrete functional testing andvisual inspection of the fire alarm systemby reducing the engineer toolset to justa mobile device phone or tablet. Nomore impact on building occupiers. Tests both the heat and smokesensors by heating the thermistorand introducing small amounts ofsmoke into the detection chamber. Gently blows the smoke out of thedetection chamber and smoke entrypoints to ensure they are not blocked. Flexible testing options allow the engineerto test in different ways single devicedetection zone loops panels. Allows up to 6 devices to be tested atonce per loop and any number of loopscan be tested simultaneously makingthe functional testing incredibly fast. Device testing is fast enough to allowup to 4 functional tests to be performedper year for the lifespan of the device. Eliminates all access issues whendetector testing ensuring 100functional testing is achieved. Allows the system to remain active whilsttesting as each detector is only offline for60 seconds and outputs are not generated. Any fires detected outside of thedevices performing Self-Test will stopthe Self-Test process and operatethe fire systems Cause Effect. Allows the engineer to easily locatethe detector using the App and BLEto check the device number labelzone description and detector type. Allows simple device updates tobe performed through the Appincluding the correction of inaccuratedevice labels and loop mapping. The app and BLE handshakeverifies that the engineer has beenwithin visual inspection range. Optional Inspection prompt LEDs onthe device let the engineer know whatSelf-Test devices need to be visuallyinspected and will automatically turn offwhen the visual inspection is complete. Engineers can spend more time digitallycapturing non-compliance issues andadvising how to resolve them. Thisincludes any issues causing false alarms. Test Fire LED option in the App allowsthe fire LED to be tested a pendingBS5839-1 testing requirement. Thisfeature can additionally confirm thatthey are inspecting the correct device. The CLSS App allows the engineerto simulate a fire and test theCause Effect logic. The CLSS App also allows theCause Effect to be triggeredthrough a successful Self-Testoperation allowing a witness test tobe performed using real smoke.

GBP 192.79
1

Gent S4T-720-V-VAD-HPR S4 SELF TEST Heat Sensor amp Voice Sounder amp High Power Red VAD

Gent S4T-720-V-VAD-HPR S4 SELF TEST Heat Sensor amp Voice Sounder amp High Power Red VAD

Gent S4T-720-V-VAD-HPR S4 SELF TEST Heat Sensor Voice Sounder High Power Red VADThis device has a new IP21 external moulding new detector chamber design anda dual microprocessor PCB. This design delivers even better smoke detection andvoice storage capacity. In addition the award-winning Self-Test feature allows boththe heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Available in a large range of multi-sensorPart-23 VAD and sounder voice options. Enables discrete functional testing andvisual inspection of the fire alarm systemby reducing the engineer toolset to justa mobile device phone or tablet. Nomore impact on building occupiers. Tests both the heat and smokesensors by heating the thermistorand introducing small amounts ofsmoke into the detection chamber. Gently blows the smoke out of thedetection chamber and smoke entrypoints to ensure they are not blocked. Flexible testing options allow the engineerto test in different ways single devicedetection zone loops panels. Allows up to 6 devices to be tested atonce per loop and any number of loopscan be tested simultaneously makingthe functional testing incredibly fast. Device testing is fast enough to allowup to 4 functional tests to be performedper year for the lifespan of the device. Eliminates all access issues whendetector testing ensuring 100functional testing is achieved. Allows the system to remain active whilsttesting as each detector is only offline for60 seconds and outputs are not generated. Any fires detected outside of thedevices performing Self-Test will stopthe Self-Test process and operatethe fire systems Cause Effect. Allows the engineer to easily locatethe detector using the App and BLEto check the device number labelzone description and detector type. Allows simple device updates tobe performed through the Appincluding the correction of inaccuratedevice labels and loop mapping. The app and BLE handshakeverifies that the engineer has beenwithin visual inspection range. Optional Inspection prompt LEDs onthe device let the engineer know whatSelf-Test devices need to be visuallyinspected and will automatically turn offwhen the visual inspection is complete. Engineers can spend more time digitallycapturing non-compliance issues andadvising how to resolve them. Thisincludes any issues causing false alarms. Test Fire LED option in the App allowsthe fire LED to be tested a pendingBS5839-1 testing requirement. Thisfeature can additionally confirm thatthey are inspecting the correct device. The CLSS App allows the engineerto simulate a fire and test theCause Effect logic. The CLSS App also allows theCause Effect to be triggeredthrough a successful Self-Testoperation allowing a witness test tobe performed using real smoke.

GBP 189.40
1

Gent S4T-711-V-VAD-HPR S4 SELF TEST Dual Optical Heat Sensor amp Voice Sounder amp High Power Red

Gent S4T-711-V-VAD-HPR S4 SELF TEST Dual Optical Heat Sensor amp Voice Sounder amp High Power Red

Gent S4T-711-V-VAD-HPR S4 SELF TEST Dual Optical Heat Sensor Voice Sounder High Power RedThis device has a new IP21 external moulding new detector chamber design anda dual microprocessor PCB. This design delivers even better smoke detection andvoice storage capacity. In addition the award-winning Self-Test feature allows boththe heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Available in a large range of multi-sensorPart-23 VAD and sounder voice options. Enables discrete functional testing andvisual inspection of the fire alarm systemby reducing the engineer toolset to justa mobile device phone or tablet. Nomore impact on building occupiers. Tests both the heat and smokesensors by heating the thermistorand introducing small amounts ofsmoke into the detection chamber. Gently blows the smoke out of thedetection chamber and smoke entrypoints to ensure they are not blocked. Flexible testing options allow the engineerto test in different ways single devicedetection zone loops panels. Allows up to 6 devices to be tested atonce per loop and any number of loopscan be tested simultaneously makingthe functional testing incredibly fast. Device testing is fast enough to allowup to 4 functional tests to be performedper year for the lifespan of the device. Eliminates all access issues whendetector testing ensuring 100functional testing is achieved. Allows the system to remain active whilsttesting as each detector is only offline for60 seconds and outputs are not generated. Any fires detected outside of thedevices performing Self-Test will stopthe Self-Test process and operatethe fire systems Cause Effect. Allows the engineer to easily locatethe detector using the App and BLEto check the device number labelzone description and detector type. Allows simple device updates tobe performed through the Appincluding the correction of inaccuratedevice labels and loop mapping. The app and BLE handshakeverifies that the engineer has beenwithin visual inspection range. Optional Inspection prompt LEDs onthe device let the engineer know whatSelf-Test devices need to be visuallyinspected and will automatically turn offwhen the visual inspection is complete. Engineers can spend more time digitallycapturing non-compliance issues andadvising how to resolve them. Thisincludes any issues causing false alarms. Test Fire LED option in the App allowsthe fire LED to be tested a pendingBS5839-1 testing requirement. Thisfeature can additionally confirm thatthey are inspecting the correct device. The CLSS App allows the engineerto simulate a fire and test theCause Effect logic. The CLSS App also allows theCause Effect to be triggeredthrough a successful Self-Testoperation allowing a witness test tobe performed using real smoke.

GBP 235.25
1

Gent S4TB-711-V-VAD-HPR S4 SELF TEST Black Dual Optical Heat Sensor amp Voice Sounder amp High Power Red VAD - Black

Gent S4TB-711-V-VAD-HPR S4 SELF TEST Black Dual Optical Heat Sensor amp Voice Sounder amp High Power Red VAD - Black

Gent S4TB-711-V-VAD-HPR S4 SELF TEST Black Dual Optical Heat Sensor Voice Sounder High Power Red VAD - BlackThis device has a new IP21 external moulding new detector chamber design anda dual microprocessor PCB. This design delivers even better smoke detection andvoice storage capacity. In addition the award-winning Self-Test feature allows boththe heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Available in a large range of multi-sensorPart-23 VAD and sounder voice options. Enables discrete functional testing andvisual inspection of the fire alarm systemby reducing the engineer toolset to justa mobile device phone or tablet. Nomore impact on building occupiers. Tests both the heat and smokesensors by heating the thermistorand introducing small amounts ofsmoke into the detection chamber. Gently blows the smoke out of thedetection chamber and smoke entrypoints to ensure they are not blocked. Flexible testing options allow the engineerto test in different ways single devicedetection zone loops panels. Allows up to 6 devices to be tested atonce per loop and any number of loopscan be tested simultaneously makingthe functional testing incredibly fast. Device testing is fast enough to allowup to 4 functional tests to be performedper year for the lifespan of the device. Eliminates all access issues whendetector testing ensuring 100functional testing is achieved. Allows the system to remain active whilsttesting as each detector is only offline for60 seconds and outputs are not generated. Any fires detected outside of thedevices performing Self-Test will stopthe Self-Test process and operatethe fire systems Cause Effect. Allows the engineer to easily locatethe detector using the App and BLEto check the device number labelzone description and detector type. Allows simple device updates tobe performed through the Appincluding the correction of inaccuratedevice labels and loop mapping. The app and BLE handshakeverifies that the engineer has beenwithin visual inspection range. Optional Inspection prompt LEDs onthe device let the engineer know whatSelf-Test devices need to be visuallyinspected and will automatically turn offwhen the visual inspection is complete. Engineers can spend more time digitallycapturing non-compliance issues andadvising how to resolve them. Thisincludes any issues causing false alarms. Test Fire LED option in the App allowsthe fire LED to be tested a pendingBS5839-1 testing requirement. Thisfeature can additionally confirm thatthey are inspecting the correct device. The CLSS App allows the engineerto simulate a fire and test theCause Effect logic. The CLSS App also allows theCause Effect to be triggeredthrough a successful Self-Testoperation allowing a witness test tobe performed using real smoke.

GBP 319.33
1

Gent 803374.EX Intrinsically Safe Dual Angle Optical Heat Detector

Gent S4-34805-EP IP67 Vigilon Manual Call Point with Resettable Element

Gent 13270-02LB 2 Zone Conventional Xenex Fire Panel

Gent 13270-02LB 2 Zone Conventional Xenex Fire Panel

Gent 13270-02LB 2 Zone Conventional Xenex Fire PanelBSI approved to EN54 Parts 2 4 the Xenex control panel can be used on installations meeting BS 5839Part1. Control panel options for 2-8 zones can be specified.Designed to simplify system installation each Xenex panel contains an integral power supply to drive up to 8 alarm sounder circuits 2 auxiliary relay contacts a zone disablement facility and also one-man test and commissioning features.Utilising LPCB approved conventional smoke or heat detectors Xenex offers exceptional value for money.Key FeaturesXenex deploys devices on conventional radial wiring layouts using standard 2-core cableDevice options include a full range of smoke detectors optical beam and duct types heat detectors fixed temperature or rate of rise types sounders strobes and bellsSounder options include shallow base deep base and bedhead sounder typesFor installations where a high degree of weatherproofing is required IP55 rated sounders sirens and bells are availableCommon accessories such as manual call points standard IP54 rated or key operated anti-vandal types available as either surface mounted or flush-fitted models door release units and Xenon flashers can all be accommodatedSpare test keys for testing manual call points without breaking the glass spare glasses packs of 10 and False alarm verification feature to filter out false alarms is selectable through softwarePlease note This product requires2 x 12v 2.1Ah Batteries NP2.1-12.

GBP 256.49
1

Gent 13271-08LB 8 Zone Xenex Conventional Fire Alarm Repeat Panel EN54 Less Batteries

Gent 13271-08LB 8 Zone Xenex Conventional Fire Alarm Repeat Panel EN54 Less Batteries

Gent 13271-08LB 8 Zone Xenex Conventional Fire Alarm Repeat Panel EN54 Less BatteriesBSI approved to EN54 Parts 2 4 the Xenex control panel can be used on installations meeting BS 5839Part1. Control panel options for 2-8 zones can be specified.Designed to simplify system installation each Xenex panel contains an integral power supply to drive up to 8 alarm sounder circuits 2 auxiliary relay contacts a zone disablement facility and also one-man test and commissioning features.Utilising LPCB approved conventional smoke or heat detectors Xenex offers exceptional value for money.Key FeaturesXenex deploys devices on conventional radial wiring layouts using standard 2-core cableDevice options include a full range of smoke detectors optical beam and duct types heat detectors fixed temperature or rate of rise types sounders strobes and bellsSounder options include shallow base deep base and bedhead sounder typesFor installations where a high degree of weatherproofing is required IP55 rated sounders sirens and bells are availableCommon accessories such as manual call points standard IP54 rated or key operated anti-vandal types available as either surface mounted or flush-fitted models door release units and Xenon flashers can all be accommodatedSpare test keys for testing manual call points without breaking the glass spare glasses packs of 10 and False alarm verification feature to filter out false alarms is selectable through softwarePlease note This product requires2 x 12v 3.2Ah Batteries NP3.2-12.

GBP 349.91
1

Gent 13270-04LB 4 Zone Conventional Xenex Fire Panel

Gent 13270-04LB 4 Zone Conventional Xenex Fire Panel

Gent 13270-04LB 4 Zone Conventional Xenex Fire PanelBSI approved to EN54 Parts 2 4 the Xenex control panel can be used on installations meeting BS 5839Part1. Control panel options for 2-8 zones can be specified.Designed to simplify system installation each Xenex panel contains an integral power supply to drive up to 8 alarm sounder circuits 2 auxiliary relay contacts a zone disablement facility and also one-man test and commissioning features.Utilising LPCB approved conventional smoke or heat detectors Xenex offers exceptional value for money.Key FeaturesXenex deploys devices on conventional radial wiring layouts using standard 2-core cableDevice options include a full range of smoke detectors optical beam and duct types heat detectors fixed temperature or rate of rise types sounders strobes and bellsSounder options include shallow base deep base and bedhead sounder typesFor installations where a high degree of weatherproofing is required IP55 rated sounders sirens and bells are availableCommon accessories such as manual call points standard IP54 rated or key operated anti-vandal types available as either surface mounted or flush-fitted models door release units and Xenon flashers can all be accommodatedSpare test keys for testing manual call points without breaking the glass spare glasses packs of 10 and False alarm verification feature to filter out false alarms is selectable through softwarePlease note This product requires2 x 12v 2.1Ah Batteries NP2.1-12.

GBP 345.66
1

Gent 803371.EX Intrinsically Safe Optical Smoke Detector

Gent SAFE-SS-D-SPARE SAFE 2 Button Stainless Steel Plus Loom

Gent SAFE-WHITE-D-SPARE SAFE 2 Button White Plus Loom

Gent S4-34741-01 34740 Angle Bracket and Base

Gent SAFE-WHITE-S-SPARE SAFE 1 Button White Plus Loom

Gent SAFE-RED-D-SPARE SAFE 2 Button Red Plus Loom

Gent SAFE-WHITE-D-KIT SAFE 2 Button White Plus Interface

Gent SAFE-SS-D-KIT SAFE 2 Button Stainless Steel Plus Interface

Gent SAFE-RED-D-KIT SAFE 2 Button Red Plus Interface

Gent SAFE-WHITE-S-KIT SAFE 1 Button White Plus Interface

Gent IP66 Weatherproof Red Body High Power Voice Sounder with Red VAD - S3EP-V-VAD-HPR-R

Gent IP66 Weatherproof Red Body High Power Voice Sounder with Red VAD - S3EP-V-VAD-HPR-R

Gent IP66 Weatherproof Red Body High Power Voice Sounder with Red VAD - S3EP-V-VAD-HPR-RS-Cubed offers a comprehensive range of loop powered alarm sounders with integrated voice and EN54-23 certified visual alarms. Combined with flexible configuration from the Gent by Honeywell fire control panels this loop powered device can give a differentiated combination of audible and visual alarms for alert and general evacuation.Very low power consumption means that the Vigilon system offers more high performance sounders and VADs on the loop than any other manufacturerKey FeaturesEach loop can support up to 200 voice sounders 100 visual alarm devices VADs and up to 70 combined sounder VADsEN54-23 VADs with adjustable light coverage matching the sounder outputComprehensive and easy to use design and commissioning toolsFour voice phrases and a bell tone available as standardVoice and tone modes can be freely configured within the same sounderActive background monitoring of sounder and VAD circuitsAdjust the sounder volume via the commissioning tool the panel or the HandiLink infrared remote controlStandard Voice Messages Alert Message female voice An incident has been reported in the building please await further instructions.Alarm Message 1 female voice Attention please this is an emergency. Please leave the building by the nearest available exit.Alarm Message 2 male voice This is a fire alarm Please leave the building immediately by the nearest available exit.Test Message female voice This is a test message no action is required.

GBP 212.32
1

Gent 803271.EX Intrinsically Safe Heat Detector Rate of Rise

Gent 803271.EX Intrinsically Safe Heat Detector Rate of Rise

Gent 803271.EX Intrinsically Safe Heat Detector Rate of RiseAutomatic heat detector with a single thermistor to sense the air temperature around the detector. The fast semiconductor sensor for the reliable recognition of fires with a single thermistor to sense the air temperature around the detector.The fast semiconductor quick rate of temperature rise as well as integrated fixed temperature heat function for the recognition of fires with slow temperature rise. Ideal for sensing in environments that are dirty or smoky under normal conditions as well it is unaffected by wind or atmospheric pressure. Intelligent fire detector with decentralized intelligence automatic function self-test emergency mode storage of alarm and operating data alarm display.Soft addressing and separate operational display is only possible when operating an esserbus esserbus-PLus IQ8Quad detector without loop isolator especially for usage in explosion zones. Operation with individual addressing at Ex barrier Part No. 804744 and as standard detector at Ex barrier Part No. 764744.Please use base 8055.Key FeaturesOperating voltage 8 - 42 V DCQuiescent current 19 V DC 40 AAlarm current 9 V DC 18 mAArea to be monitored 30 mHeight to be monitored 7.5 mApplication temperature -20 C - 50 CStorage temperature -25 C - 75 CAir humidity 95 Type of protection IP 40 with base up to IP 43 incl. base optionMaterial ABSColor white similar to RAL 9010Dimensions 117 mm H 49 mm 62 mm incl. base

GBP 179.20
1