Gent S4T-711-V S4 SELF TEST Dual Optical Heat Sensor amp Voice Sounder Gent S4T-711-V S4 SELF TEST Dual Optical Heat Sensor Voice SounderThis device has a new IP21 external moulding new detector chamber design anda dual microprocessor PCB. This design delivers even better smoke detection andvoice storage capacity. In addition the award-winning Self-Test feature allows boththe heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Available in a large range of multi-sensorPart-23 VAD and sounder voice options. Enables discrete functional testing andvisual inspection of the fire alarm systemby reducing the engineer toolset to justa mobile device phone or tablet. Nomore impact on building occupiers. Tests both the heat and smokesensors by heating the thermistorand introducing small amounts ofsmoke into the detection chamber. Gently blows the smoke out of thedetection chamber and smoke entrypoints to ensure they are not blocked. Flexible testing options allow the engineerto test in different ways single devicedetection zone loops panels. Allows up to 6 devices to be tested atonce per loop and any number of loopscan be tested simultaneously makingthe functional testing incredibly fast. Device testing is fast enough to allowup to 4 functional tests to be performedper year for the lifespan of the device. Eliminates all access issues whendetector testing ensuring 100functional testing is achieved. Allows the system to remain active whilsttesting as each detector is only offline for60 seconds and outputs are not generated. Any fires detected outside of thedevices performing Self-Test will stopthe Self-Test process and operatethe fire systems Cause Effect. Allows the engineer to easily locatethe detector using the App and BLEto check the device number labelzone description and detector type. Allows simple device updates tobe performed through the Appincluding the correction of inaccuratedevice labels and loop mapping. The app and BLE handshakeverifies that the engineer has beenwithin visual inspection range. Optional Inspection prompt LEDs onthe device let the engineer know whatSelf-Test devices need to be visuallyinspected and will automatically turn offwhen the visual inspection is complete. Engineers can spend more time digitallycapturing non-compliance issues andadvising how to resolve them. Thisincludes any issues causing false alarms. Test Fire LED option in the App allowsthe fire LED to be tested a pendingBS5839-1 testing requirement. Thisfeature can additionally confirm thatthey are inspecting the correct device. The CLSS App allows the engineerto simulate a fire and test theCause Effect logic. The CLSS App also allows theCause Effect to be triggeredthrough a successful Self-Testoperation allowing a witness test tobe performed using real smoke. GBP 190.24 1
Gent S4T-711-VAD-HPR S4 SELF TEST Dual Optical Heat Sensor amp High Power Red VAD Gent S4T-711-VAD-HPR S4 SELF TEST Dual Optical Heat Sensor High Power Red VADThis device has a new IP21 external moulding new detector chamber design anda dual microprocessor PCB. This design delivers even better smoke detection andvoice storage capacity. In addition the award-winning Self-Test feature allows boththe heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Available in a large range of multi-sensorPart-23 VAD and sounder voice options. Enables discrete functional testing andvisual inspection of the fire alarm systemby reducing the engineer toolset to justa mobile device phone or tablet. Nomore impact on building occupiers. Tests both the heat and smokesensors by heating the thermistorand introducing small amounts ofsmoke into the detection chamber. Gently blows the smoke out of thedetection chamber and smoke entrypoints to ensure they are not blocked. Flexible testing options allow the engineerto test in different ways single devicedetection zone loops panels. Allows up to 6 devices to be tested atonce per loop and any number of loopscan be tested simultaneously makingthe functional testing incredibly fast. Device testing is fast enough to allowup to 4 functional tests to be performedper year for the lifespan of the device. Eliminates all access issues whendetector testing ensuring 100functional testing is achieved. Allows the system to remain active whilsttesting as each detector is only offline for60 seconds and outputs are not generated. Any fires detected outside of thedevices performing Self-Test will stopthe Self-Test process and operatethe fire systems Cause Effect. Allows the engineer to easily locatethe detector using the App and BLEto check the device number labelzone description and detector type. Allows simple device updates tobe performed through the Appincluding the correction of inaccuratedevice labels and loop mapping. The app and BLE handshakeverifies that the engineer has beenwithin visual inspection range. Optional Inspection prompt LEDs onthe device let the engineer know whatSelf-Test devices need to be visuallyinspected and will automatically turn offwhen the visual inspection is complete. Engineers can spend more time digitallycapturing non-compliance issues andadvising how to resolve them. Thisincludes any issues causing false alarms. Test Fire LED option in the App allowsthe fire LED to be tested a pendingBS5839-1 testing requirement. Thisfeature can additionally confirm thatthey are inspecting the correct device. The CLSS App allows the engineerto simulate a fire and test theCause Effect logic. The CLSS App also allows theCause Effect to be triggeredthrough a successful Self-Testoperation allowing a witness test tobe performed using real smoke. GBP 192.79 1
Gent S4T-720-V-VAD-HPR S4 SELF TEST Heat Sensor amp Voice Sounder amp High Power Red VAD Gent S4T-720-V-VAD-HPR S4 SELF TEST Heat Sensor Voice Sounder High Power Red VADThis device has a new IP21 external moulding new detector chamber design anda dual microprocessor PCB. This design delivers even better smoke detection andvoice storage capacity. In addition the award-winning Self-Test feature allows boththe heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Available in a large range of multi-sensorPart-23 VAD and sounder voice options. Enables discrete functional testing andvisual inspection of the fire alarm systemby reducing the engineer toolset to justa mobile device phone or tablet. Nomore impact on building occupiers. Tests both the heat and smokesensors by heating the thermistorand introducing small amounts ofsmoke into the detection chamber. Gently blows the smoke out of thedetection chamber and smoke entrypoints to ensure they are not blocked. Flexible testing options allow the engineerto test in different ways single devicedetection zone loops panels. Allows up to 6 devices to be tested atonce per loop and any number of loopscan be tested simultaneously makingthe functional testing incredibly fast. Device testing is fast enough to allowup to 4 functional tests to be performedper year for the lifespan of the device. Eliminates all access issues whendetector testing ensuring 100functional testing is achieved. Allows the system to remain active whilsttesting as each detector is only offline for60 seconds and outputs are not generated. Any fires detected outside of thedevices performing Self-Test will stopthe Self-Test process and operatethe fire systems Cause Effect. Allows the engineer to easily locatethe detector using the App and BLEto check the device number labelzone description and detector type. Allows simple device updates tobe performed through the Appincluding the correction of inaccuratedevice labels and loop mapping. The app and BLE handshakeverifies that the engineer has beenwithin visual inspection range. Optional Inspection prompt LEDs onthe device let the engineer know whatSelf-Test devices need to be visuallyinspected and will automatically turn offwhen the visual inspection is complete. Engineers can spend more time digitallycapturing non-compliance issues andadvising how to resolve them. Thisincludes any issues causing false alarms. Test Fire LED option in the App allowsthe fire LED to be tested a pendingBS5839-1 testing requirement. Thisfeature can additionally confirm thatthey are inspecting the correct device. The CLSS App allows the engineerto simulate a fire and test theCause Effect logic. The CLSS App also allows theCause Effect to be triggeredthrough a successful Self-Testoperation allowing a witness test tobe performed using real smoke. GBP 189.40 1
Gent S4T-711-V-VAD-HPR S4 SELF TEST Dual Optical Heat Sensor amp Voice Sounder amp High Power Red Gent S4T-711-V-VAD-HPR S4 SELF TEST Dual Optical Heat Sensor Voice Sounder High Power RedThis device has a new IP21 external moulding new detector chamber design anda dual microprocessor PCB. This design delivers even better smoke detection andvoice storage capacity. In addition the award-winning Self-Test feature allows boththe heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Available in a large range of multi-sensorPart-23 VAD and sounder voice options. Enables discrete functional testing andvisual inspection of the fire alarm systemby reducing the engineer toolset to justa mobile device phone or tablet. Nomore impact on building occupiers. Tests both the heat and smokesensors by heating the thermistorand introducing small amounts ofsmoke into the detection chamber. Gently blows the smoke out of thedetection chamber and smoke entrypoints to ensure they are not blocked. Flexible testing options allow the engineerto test in different ways single devicedetection zone loops panels. Allows up to 6 devices to be tested atonce per loop and any number of loopscan be tested simultaneously makingthe functional testing incredibly fast. Device testing is fast enough to allowup to 4 functional tests to be performedper year for the lifespan of the device. Eliminates all access issues whendetector testing ensuring 100functional testing is achieved. Allows the system to remain active whilsttesting as each detector is only offline for60 seconds and outputs are not generated. Any fires detected outside of thedevices performing Self-Test will stopthe Self-Test process and operatethe fire systems Cause Effect. Allows the engineer to easily locatethe detector using the App and BLEto check the device number labelzone description and detector type. Allows simple device updates tobe performed through the Appincluding the correction of inaccuratedevice labels and loop mapping. The app and BLE handshakeverifies that the engineer has beenwithin visual inspection range. Optional Inspection prompt LEDs onthe device let the engineer know whatSelf-Test devices need to be visuallyinspected and will automatically turn offwhen the visual inspection is complete. Engineers can spend more time digitallycapturing non-compliance issues andadvising how to resolve them. Thisincludes any issues causing false alarms. Test Fire LED option in the App allowsthe fire LED to be tested a pendingBS5839-1 testing requirement. Thisfeature can additionally confirm thatthey are inspecting the correct device. The CLSS App allows the engineerto simulate a fire and test theCause Effect logic. The CLSS App also allows theCause Effect to be triggeredthrough a successful Self-Testoperation allowing a witness test tobe performed using real smoke. GBP 235.25 1
Gent S4TB-711-V-VAD-HPR S4 SELF TEST Black Dual Optical Heat Sensor amp Voice Sounder amp High Power Red VAD - Black Gent S4TB-711-V-VAD-HPR S4 SELF TEST Black Dual Optical Heat Sensor Voice Sounder High Power Red VAD - BlackThis device has a new IP21 external moulding new detector chamber design anda dual microprocessor PCB. This design delivers even better smoke detection andvoice storage capacity. In addition the award-winning Self-Test feature allows boththe heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Available in a large range of multi-sensorPart-23 VAD and sounder voice options. Enables discrete functional testing andvisual inspection of the fire alarm systemby reducing the engineer toolset to justa mobile device phone or tablet. Nomore impact on building occupiers. Tests both the heat and smokesensors by heating the thermistorand introducing small amounts ofsmoke into the detection chamber. Gently blows the smoke out of thedetection chamber and smoke entrypoints to ensure they are not blocked. Flexible testing options allow the engineerto test in different ways single devicedetection zone loops panels. Allows up to 6 devices to be tested atonce per loop and any number of loopscan be tested simultaneously makingthe functional testing incredibly fast. Device testing is fast enough to allowup to 4 functional tests to be performedper year for the lifespan of the device. Eliminates all access issues whendetector testing ensuring 100functional testing is achieved. Allows the system to remain active whilsttesting as each detector is only offline for60 seconds and outputs are not generated. Any fires detected outside of thedevices performing Self-Test will stopthe Self-Test process and operatethe fire systems Cause Effect. Allows the engineer to easily locatethe detector using the App and BLEto check the device number labelzone description and detector type. Allows simple device updates tobe performed through the Appincluding the correction of inaccuratedevice labels and loop mapping. The app and BLE handshakeverifies that the engineer has beenwithin visual inspection range. Optional Inspection prompt LEDs onthe device let the engineer know whatSelf-Test devices need to be visuallyinspected and will automatically turn offwhen the visual inspection is complete. Engineers can spend more time digitallycapturing non-compliance issues andadvising how to resolve them. Thisincludes any issues causing false alarms. Test Fire LED option in the App allowsthe fire LED to be tested a pendingBS5839-1 testing requirement. Thisfeature can additionally confirm thatthey are inspecting the correct device. The CLSS App allows the engineerto simulate a fire and test theCause Effect logic. The CLSS App also allows theCause Effect to be triggeredthrough a successful Self-Testoperation allowing a witness test tobe performed using real smoke. GBP 319.33 1
Gent 8 Zone Auto Reset Fire Alarm Control Panel Gent 8 Zone Auto Reset Fire Alarm Control Panel, Auto Reset: Yes, Control Types: Cancel, Disable Zone, Fault Buzzer, Lamp Test, Reset, Silence Alarms, Sound Alarms, MPN: 75585-08 GBP 362.50 1
Gent 2 Zone Auto Reset Fire Alarm Control Panel Gent 2 Zone Auto Reset Fire Alarm Control Panel, Auto Reset: Yes, Control Types: Cancel, Disable Zone, Fault Buzzer, Lamp Test, Reset, Silence Alarms, Sound Alarms, MPN: 75585-02 GBP 213.20 1
Gent Programmer Base for S4 and S3 Voice Sounder Devices S4-BASE-PROGRAM Gent Programmer Base for S4 and S3 Voice Sounder Devices S4-BASE-PROGRAMThis S-Quad programming tool S4-BASE-PROGRAM is used to test and programme S-Quad speech products. GBP 284.51 1
Gent 803374.EX Intrinsically Safe Dual Angle Optical Heat Detector Gent 803374.EX Intrinsically Safe Dual Angle Optical Heat DetectorScattered-light smoke detector for reliable early recognition of fires. Responds well to slow-burning smouldering fires. Intelligent fire detector with decentralized intelligence automatic function self-test emergency mode storage of alarm and operating data alarm display. Soft addressing and separate operational display is only possible when operating an esserbusesserbus-PLus IQ8Quad detector without loop isolator especially for usage in explosion zones. GBP 222.52 1
Gent S4-34805-EP IP67 Vigilon Manual Call Point with Resettable Element Gent S4-34805-EP IP67 Vigilon Manual Call Point with Resettable ElementThe Gent S4-34805-EP is an IP67 Rated addressable manual call point designed for use with the Gent Vigilon range of analogue addressable control panels. It is IP67 rated and comes complete with resettable element test key and a lift-up protective cover.Key FeaturesWeatherproofIP67 ratedComplete with hinged plastic coverResettable elementTest key includedLift up protective coverBuilt in isolatorSupplied with back boxFor use with the Gent Vigilon range of analogue addressable control panels GBP 226.76 1
Gent 13271-08LB 8 Zone Xenex Conventional Fire Alarm Repeat Panel EN54 Less Batteries Gent 13271-08LB 8 Zone Xenex Conventional Fire Alarm Repeat Panel EN54 Less BatteriesBSI approved to EN54 Parts 2 4 the Xenex control panel can be used on installations meeting BS 5839Part1. Control panel options for 2-8 zones can be specified.Designed to simplify system installation each Xenex panel contains an integral power supply to drive up to 8 alarm sounder circuits 2 auxiliary relay contacts a zone disablement facility and also one-man test and commissioning features.Utilising LPCB approved conventional smoke or heat detectors Xenex offers exceptional value for money.Key FeaturesXenex deploys devices on conventional radial wiring layouts using standard 2-core cableDevice options include a full range of smoke detectors optical beam and duct types heat detectors fixed temperature or rate of rise types sounders strobes and bellsSounder options include shallow base deep base and bedhead sounder typesFor installations where a high degree of weatherproofing is required IP55 rated sounders sirens and bells are availableCommon accessories such as manual call points standard IP54 rated or key operated anti-vandal types available as either surface mounted or flush-fitted models door release units and Xenon flashers can all be accommodatedSpare test keys for testing manual call points without breaking the glass spare glasses packs of 10 and False alarm verification feature to filter out false alarms is selectable through softwarePlease note This product requires2 x 12v 3.2Ah Batteries NP3.2-12. GBP 349.91 1
Gent 13270-02LB 2 Zone Conventional Xenex Fire Panel Gent 13270-02LB 2 Zone Conventional Xenex Fire PanelBSI approved to EN54 Parts 2 4 the Xenex control panel can be used on installations meeting BS 5839Part1. Control panel options for 2-8 zones can be specified.Designed to simplify system installation each Xenex panel contains an integral power supply to drive up to 8 alarm sounder circuits 2 auxiliary relay contacts a zone disablement facility and also one-man test and commissioning features.Utilising LPCB approved conventional smoke or heat detectors Xenex offers exceptional value for money.Key FeaturesXenex deploys devices on conventional radial wiring layouts using standard 2-core cableDevice options include a full range of smoke detectors optical beam and duct types heat detectors fixed temperature or rate of rise types sounders strobes and bellsSounder options include shallow base deep base and bedhead sounder typesFor installations where a high degree of weatherproofing is required IP55 rated sounders sirens and bells are availableCommon accessories such as manual call points standard IP54 rated or key operated anti-vandal types available as either surface mounted or flush-fitted models door release units and Xenon flashers can all be accommodatedSpare test keys for testing manual call points without breaking the glass spare glasses packs of 10 and False alarm verification feature to filter out false alarms is selectable through softwarePlease note This product requires2 x 12v 2.1Ah Batteries NP2.1-12. GBP 256.49 1
Gent 13270-04LB 4 Zone Conventional Xenex Fire Panel Gent 13270-04LB 4 Zone Conventional Xenex Fire PanelBSI approved to EN54 Parts 2 4 the Xenex control panel can be used on installations meeting BS 5839Part1. Control panel options for 2-8 zones can be specified.Designed to simplify system installation each Xenex panel contains an integral power supply to drive up to 8 alarm sounder circuits 2 auxiliary relay contacts a zone disablement facility and also one-man test and commissioning features.Utilising LPCB approved conventional smoke or heat detectors Xenex offers exceptional value for money.Key FeaturesXenex deploys devices on conventional radial wiring layouts using standard 2-core cableDevice options include a full range of smoke detectors optical beam and duct types heat detectors fixed temperature or rate of rise types sounders strobes and bellsSounder options include shallow base deep base and bedhead sounder typesFor installations where a high degree of weatherproofing is required IP55 rated sounders sirens and bells are availableCommon accessories such as manual call points standard IP54 rated or key operated anti-vandal types available as either surface mounted or flush-fitted models door release units and Xenon flashers can all be accommodatedSpare test keys for testing manual call points without breaking the glass spare glasses packs of 10 and False alarm verification feature to filter out false alarms is selectable through softwarePlease note This product requires2 x 12v 2.1Ah Batteries NP2.1-12. GBP 345.66 1
Gent S4 CO Dual Optical Heat Sensor Voice Sounder High Power Red VAD S4-911-V-VAD-HPR Gent S4 CO Dual Optical Heat Sensor Voice Sounder High Power Red VAD S4-911-V-VAD-HPRThe S4-911-V-VAD-HPR Dual Optical Heat Multi Sensor Voice and High Power Red VAD features a unique combination of sensing elements to provide easy and quick intelligent fire decisions. This device is designed for use with the Gent Vigilon range of analogue addressable fire alarm control panels.Key FeaturesComplete range of sensors with combinations of advanced sensing technologies including heat dual angle optical scatter and carbon monoxide COCombined sensing of carbon monoxide with dual angle optical scatter and heat allows a higher level of false alarm immunity in presence of steam and while still maintaining the integrity of detecting firesEach sensor has certified sensitivity settings that suit certain environments applications and may be programmed for different times of the day if requiredShort circuit Isolator in each deviceConfigurable input output connection for remote indicator or supervisory input fully synchronised sound patterns via the control panelSensor sounders have adjustable sound level and tones to match system soundersSounder element monitoring and over-load protection to ensure operation even in event of cable faultSound output synchronised and compatible with S-Quad range of EN54-23 VADs GBP 245.45 1
Gent 803371.EX Intrinsically Safe Optical Smoke Detector Gent 803371.EX Intrinsically Safe Optical Smoke DetectorScattered-light smoke detector for reliable early recognition of fires. Responds well to slow-burning smouldering fires. Intelligent fire detector with decentralized intelligence automatic function self-test emergency mode storage of alarm and operating data alarm display.Soft addressing and separate operational display is only possible when operating an esserbus esserbus-PLus IQ8Quad detector without loop isolator especially for usage in explosion zones. Operation with individual addressing at Ex barrier Part No. 804744 and as standard detector at Ex barrier Part No. 764744.Please use base 805590.Key FeaturesOperating voltage 8 - 42 V DQuiescent current 19 V DC 50 AAlarm current 9 V DC 18 mAArea to be monitored 110 mHeight to be monitored 12 mApplication temperature -20 C - 70 CStorage temperature -25 C - 75 CAir humidity 95 Type of protection IP 40 with base up to IP 43 incl. base optionMaterial ABSColour white similar to RAL 9010 W.Dimensions 117 mm H 49 mm 62 mm incl. base GBP 208.08 1
Gent S4 Dual Optical Heat Sensor Voice Sounder Black Body S4BK-711-V Gent S4 Dual Optical Heat Sensor Voice Sounder Black Body S4BK-711-VGent S4BK-711-V Dual Optical Black Heat Sensor with Voice is a Gent Vigilon S-Quad sensor with a unique combination of sensing elements to provide quick intelligent fire decisions. Smoke detection is enhanced using patented dual optical scatter technology. This allows it to be configured to filter specific risks such as steam and dust resulting in significantly reduced false alarms.Voice messages stored on a memory chip in the sensor can be triggered to give clearly understood messages leading to quicker and safer evacuation.Key FeaturesComplete range of sensors with combinations of advanced sensing technologies including heat dual angle optical scatter and carbon monoxide COCombined sensing of carbon monoxide with dual angle optical scatter and heat allows a higher level of false alarm immunity in presence of steam and while still maintaining the integrity of detecting firesEach sensor has certified sensitivity settings that suit certain environments applications and may be programmed for different times of the day if requiredShort circuit Isolator in each deviceConfigurable inputoutput connection for remote indicator or supervisory input fully synchronised sound patterns via the control panelSensor sounders have adjustable sound level and tones to match system soundersSounder element monitoring and over-load protection to ensure operation even in event of cable faultSound output synchronised and compatible with S-Quad range of EN54-23 VADs GBP 236.95 1
Gent S4-34741-01 34740 Angle Bracket and Base Gent S4-34741-01 34740 Angle Bracket and Base The Gent S4-34741-01 Beam Detector Angle Bracket Base is designed for use in areas where the S4-34740 beam detector will not be installed to a vertical surface or where the beam path is not perpendicular to the installation surface. It is supplied with a pre-installed S-Quad base.Gents S-Quad Beam Sensors provides an enhanced solution for linear beam detection for applications where point detection is either not practical or economic.Powered and controlled via the loop the beam is a market leading device with features such as one man alignment and commissioning which is achieved using the auto gain setting this ensure the optimum alignment is reached.Maintenance of the beam is enhanced with a key operated test feature which simulates the obscuration of the beam in a fire. The Gent loop powered beam is certified to EN54 parts 12 and 17.Key FeaturesAngle Bracket for difficult applications allowing wide angle adjustment up to - 30Multi angle fittingSupplied with baseSimple alignment GBP 180.05 1
Gent SAFE-WHITE-S-SPARE SAFE 1 Button White Plus Loom Gent SAFE-WHITE-S-SPARE SAFE 1 Button White Plus LoomThe SAFE-WHITE-S-SPARE is a spare SAFE 1 Stainless Steel Button.SAFE is a fully engineered solution for your building to allow you to bridge the gap between BS5839 Part 1 and BS5839 Part 6 without the risk of generating multiple false evacuations.Using our industry leading S-Quads and through the power of voice it enables clear alert and evacuation guidance to any building occupant.EN54 Part 2 Type B Dependency Approved.The SAFE buttons allows the occupants to control their local alarms in their alarm areas.The SAFE buttons allows the occupant to silence and test their local alarms. A confirmation LED is included to visually inform occupants that action has taken place.The button delays are fully configurable within the Vigilon Panel to cater for many applications where events can be managed by the user.In the landlords areas this will be designed to BS5839 Part 1 standards and in the residential areas to BS5839 Part 6 allowing you to manage your buildings installation to the appropriate standard. GBP 197.88 1
Gent SAFE-WHITE-D-SPARE SAFE 2 Button White Plus Loom Gent SAFE-WHITE-D-SPARE SAFE 2 Button White Plus LoomThe SAFE-WHITE-D-SPARE is a spare SAFE 2 Button in the colour white.SAFE is a fully engineered solution for your building to allow you to bridge the gap between BS5839 Part 1 and BS5839 Part 6 without the risk of generating multiple false evacuations.Using our industry leading S-Quads and through the power of voice it enables clear alert and evacuation guidance to any building occupant.EN54 Part 2 Type B Dependency Approved.The SAFE buttons allows the occupants to control their local alarms in their alarm areas.The SAFE buttons allows the occupant to silence and test their local alarms. A confirmation LED is included to visually inform occupants that action has taken place.The button delays are fully configurable within the Vigilon Panel to cater for many applications where events can be managed by the user.In the landlords areas this will be designed to BS5839 Part 1 standards and in the residential areas to BS5839 Part 6 allowing you to manage your buildings installation to the appropriate standard. GBP 197.88 1
Gent SAFE-RED-D-SPARE SAFE 2 Button Red Plus Loom Gent SAFE-RED-D-SPARE SAFE 2 Button Red Plus LoomThe SAFE-RED-D-SPARE is a spare SAFE 2 Button in the colour red.SAFE is a fully engineered solution for your building to allow you to bridge the gap between BS5839 Part 1 and BS5839 Part 6 without the risk of generating multiple false evacuations.Using our industry leading S-Quads and through the power of voice it enables clear alert and evacuation guidance to any building occupant.EN54 Part 2 Type B Dependency Approved.The SAFE buttons allows the occupants to control their local alarms in their alarm areas.The SAFE buttons allows the occupant to silence and test their local alarms. A confirmation LED is included to visually inform occupants that action has taken place.The button delays are fully configurable within the Vigilon Panel to cater for many applications where events can be managed by the user.In the landlords areas this will be designed to BS5839 Part 1 standards and in the residential areas to BS5839 Part 6 allowing you to manage your buildings installation to the appropriate standard. GBP 207.23 1
Gent SAFE-SS-D-KIT SAFE 2 Button Stainless Steel Plus Interface Gent SAFE-SS-D-KIT SAFE 2 Button Stainless Steel Plus InterfaceSAFE is a fully engineered solution for your building to allow you to bridge the gap between BS5839 Part 1 and BS5839 Part 6 without the risk of generating multiple false evacuations.Using our industry leading S-Quads and through the power of voice it enables clear alert and evacuation guidance to any building occupant.EN54 Part 2 Type B Dependency Approved.The SAFE buttons allows the occupants to control their local alarms in their alarm areas.The SAFE buttons allows the occupant to silence and test their local alarms. A confirmation LED is included to visually inform occupants that action has taken place.The button delays are fully configurable within the Vigilon Panel to cater for many applications where events can be managed by the user.In the landlords areas this will be designed to BS5839 Part 1 standards and in the residential areas to BS5839 Part 6 allowing you to manage your buildings installation to the appropriate standard.The SAFE 2 position switch kit containsSAFE Switch4 Channel InterfaceWiring loom Does not include interface enclosure GBP 300.65 1
Gent SAFE-SS-D-SPARE SAFE 2 Button Stainless Steel Plus Loom Gent SAFE-SS-D-SPARE SAFE 2 Button Stainless Steel Plus LoomThe SAFE-SS-D-SPAREis a spare SAFE 2 Stainless Steel Button.SAFE is a fully engineered solution for your building to allow you to bridge the gap between BS5839 Part 1 and BS5839 Part 6 without the risk of generating multiple false evacuations.Using our industry leading S-Quads and through the power of voice it enables clear alert and evacuation guidance to any building occupant.EN54 Part 2 Type B Dependency Approved.The SAFE buttons allows the occupants to control their local alarms in their alarm areas.The SAFE buttons allows the occupant to silence and test their local alarms. A confirmation LED is included to visually inform occupants that action has taken place.The button delays are fully configurable within the Vigilon Panel to cater for many applications where events can be managed by the user.In the landlords areas this will be designed to BS5839 Part 1 standards and in the residential areas to BS5839 Part 6 allowing you to manage your buildings installation to the appropriate standard. GBP 207.23 1
Gent SAFE-WHITE-D-KIT SAFE 2 Button White Plus Interface Gent SAFE-WHITE-D-KIT SAFE 2 Button White Plus InterfaceSAFE is a fully engineered solution for your building to allow you to bridge the gap between BS5839 Part 1 and BS5839 Part 6 without the risk of generating multiple false evacuations.Using our industry leading S-Quads and through the power of voice it enables clear alert and evacuation guidance to any building occupant.EN54 Part 2 Type B Dependency Approved.The SAFE buttons allows the occupants to control their local alarms in their alarm areas.The SAFE buttons allows the occupant to silence and test their local alarms. A confirmation LED is included to visually inform occupants that action has taken place.The button delays are fully configurable within the Vigilon Panel to cater for many applications where events can be managed by the user.In the landlords areas this will be designed to BS5839 Part 1 standards and in the residential areas to BS5839 Part 6 allowing you to manage your buildings installation to the appropriate standard.The SAFE 2 position switch kit containsSAFE Switch4 Channel InterfaceWiring loom Does not include interface enclosure GBP 318.48 1
Gent SAFE-RED-D-KIT SAFE 2 Button Red Plus Interface Gent SAFE-RED-D-KIT SAFE 2 Button Red Plus InterfaceSAFE is a fully engineered solution for your building to allow you to bridge the gap between BS5839 Part 1 and BS5839 Part 6 without the risk of generating multiple false evacuations.Using our industry leading S-Quads and through the power of voice it enables clear alert and evacuation guidance to any building occupant.EN54 Part 2 Type B Dependency Approved.The SAFE buttons allows the occupants to control their local alarms in their alarm areas.The SAFE buttons allows the occupant to silence and test their local alarms. A confirmation LED is included to visually inform occupants that action has taken place.The button delays are fully configurable within the Vigilon Panel to cater for many applications where events can be managed by the user.In the landlords areas this will be designed to BS5839 Part 1 standards and in the residential areas to BS5839 Part 6 allowing you to manage your buildings installation to the appropriate standard.The SAFE 2 position switch kit containsSAFE Switch4 Channel InterfaceWiring loom Does not include interface enclosure GBP 349.91 1
Gent S4 Dual Optical Heat Sensor Voice Sounder High Power Red VAD Black Body S4BK-711-V-VAD-HPR Gent S4 Dual Optical Heat Sensor Voice Sounder High Power Red VAD Black Body S4BK-711-V-VAD-HPRGent S4BK-711-V-VAD-HPR Dual Optical Black Heat Sensor with Voice and High Power Red VAD is a Gent Vigilon S-Quad sensor with a unique combination of sensing elements to provide quick intelligent fire decisions. Smoke detection is enhanced using patented dual optical scatter technology. This allows it to be configured to filter specific risks such as steam and dust resulting in significantly reduced false alarms.The Gent S4-711-V-VAD-HPR provides a cost effective solution for alarm signalling.Key FeaturesComplete range of sensors with combinations of advanced sensing technologies including heat dual angle optical scatter and carbon monoxide COCombined sensing of carbon monoxide with dual angle optical scatter and heat allows a higher level of false alarm immunity in presence of steam and while still maintaining the integrity of detecting firesEach sensor has certified sensitivity settings that suit certain environments applications and may be programmed for different times of the day if requiredShort circuit Isolator in each deviceConfigurable inputoutput connection for remote indicator or supervisory input fully synchronised sound patterns via the control panelSensor sounders have adjustable sound level and tones to match system soundersSounder element monitoring and over-load protection to ensure operation even in event of cable faultSound output synchronised and compatible with S-Quad range of EN54-23 VADs GBP 304.04 1