Gent S4-34741-50 Obscuration Test Card Set Gent S4-34741-50 Obscuration Test Card SetThe S4-34741-50 is an Obscuration Test Card Set designed for use with Gent Beam Detectors.Honeywell Gents S-Quad Beam Sensors provides an enhanced solution for linear beam detection for applications where point detection is either not practical or economic.Powered and controlled via the loop the beam is a market leading device with features such as one man alignment and commissioning which is achieved using the auto gain setting this ensure the optimum alignment is reached.Maintenance of the beam is enhanced with a key operated test feature which simulates the obscuration of the beam in a fire. The Gent loop powered beam is certified to EN54 parts 12 and 17.Key FeaturesS-Quad Beam pairs are loop powered supporting 16 pairs per loopEach beam can be set to one of 6 sensitivity states to provide a best fi t for individual applicationsThe beam provides increased resilience to interference from the sun and other light sourcesRemote key switch provides test facility at ground level without the need to gain access to beams mounted in high areasThe beam incorporates an LED array to indicate signal strength allowing accurate alignment during one person commissioningOptimum sensitivity is maintained by automatic gain setting triggered at the beam during alignmentThe optical lens design is intended to minimise build-up of dust to reduce the maintenance and cleaning requiredThe S-Quad beam is compatible with early versions of the Vigilon Beam using the S-Quad programming base avoiding the need to upgrade to latest control software GBP 32.03 1
Gent S4T-DEMO S4T Self Test Demonstration Kit Gent S4T-DEMO S4T Self Test Demonstration KitA S4T Self Test Demonstration Kit. GBP 450.82 1
Gent 14112-10 Call Point Test Key Pack of 10 Gent 14112-10 Call Point Test Key Pack of 10The 14112-10 is a replacement Test Key designed for older style Gent Manual Call Points.Key FeaturesPack of 10Compatible with the Old Type Square Gent Call PointsEnables the user to perform a weely fire test GBP 22.86 1
Gent S4T-720 S4 SELF TEST Heat Sensor Gent S4T-720 S4 SELF TEST Heat SensorThe GENT S4T-720 Self-Test Heat Sensor has a new IP21 external moulding new detector chamber design and a dual microprocessor PCB. This design delivers even better smoke detection and voice storage capacity. In addition the award-winning Self-Test feature allows both the heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Enables discrete functional testing and visual inspection of the fire alarm system by reducing the engineer toolset to just a mobile device phone or tablet. No more impact on building occupiers Tests both the heat and smoke sensors by heating the thermistor and introducing small amounts of smoke into the detection chamber Gently blows the smoke out of the detection chamber and smoke entry points to ensure they are not blocked Flexible testing options allow the engineer to test in different ways single device detection zone loops panels Allows up to 6 devices to be tested at once per loop and any number of loops can be tested simultaneously making the functional testing incredibly fast Device testing is fast enough to allow up to 4 functional tests to be performed per year for the lifespan of the device Eliminates all access issues when detector testing ensuring 100 functional testing is achieved Allows the system to remain active whilst testing as each detector is only offline for 60 seconds and outputs are not generated Any fires detected outside of the devices performing Self-Test will stop the Self-Test process and operate the fire systems Cause Effect Allows the engineer to easily locate the detector using the App and BLE to check the device number label zone description and detector type Allows simple device updates to be performed through the App including the correction of inaccurate device labels and loop mapping The app and BLE handshake verifies that the engineer has been within visual inspection range Optional Inspection prompt LEDs on the device let the engineer know what Self-Test devices need to be visually inspected and will automatically turn off when the visual inspection is complete Engineers can spend more time digitally capturing non-compliance issues and advising how to resolve them. This includes any issues causing false alarms Test Fire LED option in the App allows the fire LED to be tested a pending BS5839-1 testing requirement. This feature can additionally confirm that they are inspecting the correct device The CLSS App allows the engineer to simulate a fire and test the Cause Effect logic The CLSS App also allows the Cause Effect to be triggered through a successful Self-Test operation allowing a witness test to be performed using real smoke GBP 100.21 1
Gent S4T-710 S4 SELF TEST Optical Heat Sensor Gent S4T-710 S4 SELF TEST Optical Heat SensorThe GENT S4T-710 Self-Test Optical Heat Multisensor has a new IP21 external moulding new detector chamber design and a dual microprocessor PCB. This design delivers even better smoke detection and voice storage capacity. In addition the award-winning Self-Test feature allows both the heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Tests both the heat and smoke sensors by heating the thermistor and introducing small amounts of smoke into the detection chamber Gently blows the smoke out of the detection chamber and smoke entry points to ensure they are not blocked Flexible testing options allow the engineer to test in different ways single device detection zone loops panels Allows up to 6 devices to be tested at once per loop and any number of loops can be tested simultaneously making the functional testing incredibly fast Device testing is fast enough to allow up to 4 functional tests to be performed per year for the lifespan of the device Eliminates all access issues when detector testing ensuring 100 functional testing is achieved Allows the system to remain active whilst testing as each detector is only offline for 60 seconds and outputs are not generated Any fires detected outside of the devices performing Self-Test will stop the Self-Test process and operate the fire systems Cause Effect Allows the engineer to easily locate the detector using the App and BLE to check the device number label zone description and detector type Allows simple device updates to be performed through the App including the correction of inaccurate device labels and loop mapping The app and BLE handshake verifies that the engineer has been within visual inspection range Optional Inspection prompt LEDs on the device let the engineer know what Self-Test devices need to be visually inspected and will automatically turn off when the visual inspection is complete Engineers can spend more time digitally capturing non-compliance issues and advising how to resolve them. This includes any issues causing false alarms Test Fire LED option in the App allows the fire LED to be tested a pending BS5839-1 testing requirement. This feature can additionally confirm that they are inspecting the correct device The CLSS App allows the engineer to simulate a fire and test the Cause Effect logic The CLSS App also allows the Cause Effect to be triggered through a successful Self-Test operation allowing a witness test to be performed using real smoke GBP 105.31 1
Gent S4T-711 S4 SELF TEST Dual Optical Heat Sensor Gent S4T-711 S4 SELF TEST Dual Optical Heat SensorThe S4T-711 Self-Test Dual Optical Heat Multisensor has a new IP21 external moulding new detector chamber design and a dual microprocessor PCB. This design delivers even better smoke detection and voice storage capacity. In addition the award-winning Self-Test feature allows both the heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Enables discrete functional testing and visual inspection of the fire alarm system by reducing the engineer toolset to just a mobile device phone or tablet. No more impact on building occupiers Tests both the heat and smoke sensors by heating the thermistor and introducing small amounts of smoke into the detection chamber Gently blows the smoke out of the detection chamber and smoke entry points to ensure they are not blocked Flexible testing options allow the engineer to test in different ways single device detection zone loops panels Allows up to 6 devices to be tested at once per loop and any number of loops can be tested simultaneously making the functional testing incredibly fast Device testing is fast enough to allow up to 4 functional tests to be performed per year for the lifespan of the device Eliminates all access issues when detector testing ensuring 100 functional testing is achieved Allows the system to remain active whilst testing as each detector is only offline for 60 seconds and outputs are not generated Any fires detected outside of the devices performing Self-Test will stop the Self-Test process and operate the fire systems Cause Effect Allows the engineer to easily locate the detector using the App and BLE to check the device number label zone description and detector type Allows simple device updates to be performed through the App including the correction of inaccurate device labels and loop mapping The app and BLE handshake verifies that the engineer has been within visual inspection range Optional Inspection prompt LEDs on the device let the engineer know what Self-Test devices need to be visually inspected and will automatically turn off when the visual inspection is complete Engineers can spend more time digitally capturing non-compliance issues and advising how to resolve them. This includes any issues causing false alarms Test Fire LED option in the App allows the fire LED to be tested a pending BS5839-1 testing requirement. This feature can additionally confirm that they are inspecting the correct device The CLSS App allows the engineer to simulate a fire and test the Cause Effect logic The CLSS App also allows the Cause Effect to be triggered through a successful Self-Test operation allowing a witness test to be performed using real smoke GBP 121.45 1
Gent S4T-780-S S4 SELF TEST Heat Sensor and Sounder Gent S4T-780-S S4 SELF TEST Heat Sensor and SounderThe GENT S4T-780-S Self-Test Heat Sensor with Integrated Sounder has a new IP21 external moulding new detector chamber design and a dual microprocessor PCB. This design delivers even better smoke detection and voice storage capacity. In addition the award-winning Self-Test feature allows both the heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Enables discrete functional testing and visual inspection of the fire alarm system by reducing the engineer toolset to just a mobile device phone or tablet. No more impact on building occupiers Tests both the heat and smoke sensors by heating the thermistor and introducing small amounts of smoke into the detection chamber Gently blows the smoke out of the detection chamber and smoke entry points to ensure they are not blocked Flexible testing options allow the engineer to test in different ways single device detection zone loops panels Allows up to 6 devices to be tested at once per loop and any number of loops can be tested simultaneously making the functional testing incredibly fast Device testing is fast enough to allow up to 4 functional tests to be performed per year for the lifespan of the device Eliminates all access issues when detector testing ensuring 100 functional testing is achieved Allows the system to remain active whilst testing as each detector is only offline for 60 seconds and outputs are not generated Any fires detected outside of the devices performing Self-Test will stop the Self-Test process and operate the fire systems Cause Effect Allows the engineer to easily locate the detector using the App and BLE to check the device number label zone description and detector type Allows simple device updates to be performed through the App including the correction of inaccurate device labels and loop mapping The app and BLE handshake verifies that the engineer has been within visual inspection range Optional Inspection prompt LEDs on the device let the engineer know what Self-Test devices need to be visually inspected and will automatically turn off when the visual inspection is complete Engineers can spend more time digitally capturing non-compliance issues and advising how to resolve them. This includes any issues causing false alarms Test Fire LED option in the App allows the fire LED to be tested a pending BS5839-1 testing requirement. This feature can additionally confirm that they are inspecting the correct device The CLSS App allows the engineer to simulate a fire and test the Cause Effect logic The CLSS App also allows the Cause Effect to be triggered through a successful Self-Test operation allowing a witness test to be performed using real smoke GBP 141.83 1
Gent S4T-770-S S4 SELF TEST Optical Heat Sensor amp Sounder Gent S4T-770-S S4 SELF TEST Optical Heat Sensor SounderThe GENT S4T-770-S Self-Test Optical Heat Multisensor with Integrated Sounder has a new IP21 external moulding new detector chamber design and a dual microprocessor PCB. This design delivers even better smoke detection and voice storage capacity. In addition the award-winning Self-Test feature allows both the heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Enables discrete functional testing and visual inspection of the fire alarm system by reducing the engineer toolset to just a mobile device phone or tablet. No more impact on building occupiers Tests both the heat and smoke sensors by heating the thermistor and introducing small amounts of smoke into the detection chamber Gently blows the smoke out of the detection chamber and smoke entry points to ensure they are not blocked Flexible testing options allow the engineer to test in different ways single device detection zone loops panels Allows up to 6 devices to be tested at once per loop and any number of loops can be tested simultaneously making the functional testing incredibly fast Device testing is fast enough to allow up to 4 functional tests to be performed per year for the lifespan of the device Eliminates all access issues when detector testing ensuring 100 functional testing is achieved Allows the system to remain active whilst testing as each detector is only offline for 60 seconds and outputs are not generated Any fires detected outside of the devices performing Self-Test will stop the Self-Test process and operate the fire systems Cause Effect Allows the engineer to easily locate the detector using the App and BLE to check the device number label zone description and detector type Allows simple device updates to be performed through the App including the correction of inaccurate device labels and loop mapping The app and BLE handshake verifies that the engineer has been within visual inspection range Optional Inspection prompt LEDs on the device let the engineer know what Self-Test devices need to be visually inspected and will automatically turn off when the visual inspection is complete Engineers can spend more time digitally capturing non-compliance issues and advising how to resolve them. This includes any issues causing false alarms Test Fire LED option in the App allows the fire LED to be tested a pending BS5839-1 testing requirement. This feature can additionally confirm that they are inspecting the correct device The CLSS App allows the engineer to simulate a fire and test the Cause Effect logic The CLSS App also allows the Cause Effect to be triggered through a successful Self-Test operation allowing a witness test to be performed using real smoke GBP 134.18 1
Gent S4T-771-S S4 SELF TEST Dual Optical Heat Sensor amp Sounder Gent S4T-771-S S4 SELF TEST Dual Optical Heat Sensor SounderThe GENT S4T-771-S Self-Test Dual Optical Heat Multisensor with Integrated Sounder has a new IP21 external moulding new detector chamber design and a dual microprocessor PCB. This design delivers even better smoke detection and voice storage capacity. In addition the award-winning Self-Test feature allows both the heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Enables discrete functional testing and visual inspection of the fire alarm system by reducing the engineer toolset to just a mobile device phone or tablet. No more impact on building occupiers Tests both the heat and smoke sensors by heating the thermistor and introducing small amounts of smoke into the detection chamber Gently blows the smoke out of the detection chamber and smoke entry points to ensure they are not blocked Flexible testing options allow the engineer to test in different ways single device detection zone loops panels Allows up to 6 devices to be tested at once per loop and any number of loops can be tested simultaneously making the functional testing incredibly fast Device testing is fast enough to allow up to 4 functional tests to be performed per year for the lifespan of the device Eliminates all access issues when detector testing ensuring 100 functional testing is achieved Allows the system to remain active whilst testing as each detector is only offline for 60 seconds and outputs are not generated Any fires detected outside of the devices performing Self-Test will stop the Self-Test process and operate the fire systems Cause Effect Allows the engineer to easily locate the detector using the App and BLE to check the device number label zone description and detector type Allows simple device updates to be performed through the App including the correction of inaccurate device labels and loop mapping The app and BLE handshake verifies that the engineer has been within visual inspection range Optional Inspection prompt LEDs on the device let the engineer know what Self-Test devices need to be visually inspected and will automatically turn off when the visual inspection is complete Engineers can spend more time digitally capturing non-compliance issues and advising how to resolve them. This includes any issues causing false alarms Test Fire LED option in the App allows the fire LED to be tested a pending BS5839-1 testing requirement. This feature can additionally confirm that they are inspecting the correct device The CLSS App allows the engineer to simulate a fire and test the Cause Effect logic The CLSS App also allows the Cause Effect to be triggered through a successful Self-Test operation allowing a witness test to be performed using real smoke GBP 156.26 1
Gent S4T-711-V S4 SELF TEST Dual Optical Heat Sensor amp Voice Sounder Gent S4T-711-V S4 SELF TEST Dual Optical Heat Sensor Voice SounderThis device has a new IP21 external moulding new detector chamber design anda dual microprocessor PCB. This design delivers even better smoke detection andvoice storage capacity. In addition the award-winning Self-Test feature allows boththe heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Available in a large range of multi-sensorPart-23 VAD and sounder voice options. Enables discrete functional testing andvisual inspection of the fire alarm systemby reducing the engineer toolset to justa mobile device phone or tablet. Nomore impact on building occupiers. Tests both the heat and smokesensors by heating the thermistorand introducing small amounts ofsmoke into the detection chamber. Gently blows the smoke out of thedetection chamber and smoke entrypoints to ensure they are not blocked. Flexible testing options allow the engineerto test in different ways single devicedetection zone loops panels. Allows up to 6 devices to be tested atonce per loop and any number of loopscan be tested simultaneously makingthe functional testing incredibly fast. Device testing is fast enough to allowup to 4 functional tests to be performedper year for the lifespan of the device. Eliminates all access issues whendetector testing ensuring 100functional testing is achieved. Allows the system to remain active whilsttesting as each detector is only offline for60 seconds and outputs are not generated. Any fires detected outside of thedevices performing Self-Test will stopthe Self-Test process and operatethe fire systems Cause Effect. Allows the engineer to easily locatethe detector using the App and BLEto check the device number labelzone description and detector type. Allows simple device updates tobe performed through the Appincluding the correction of inaccuratedevice labels and loop mapping. The app and BLE handshakeverifies that the engineer has beenwithin visual inspection range. Optional Inspection prompt LEDs onthe device let the engineer know whatSelf-Test devices need to be visuallyinspected and will automatically turn offwhen the visual inspection is complete. Engineers can spend more time digitallycapturing non-compliance issues andadvising how to resolve them. Thisincludes any issues causing false alarms. Test Fire LED option in the App allowsthe fire LED to be tested a pendingBS5839-1 testing requirement. Thisfeature can additionally confirm thatthey are inspecting the correct device. The CLSS App allows the engineerto simulate a fire and test theCause Effect logic. The CLSS App also allows theCause Effect to be triggeredthrough a successful Self-Testoperation allowing a witness test tobe performed using real smoke. GBP 190.24 1
Gent S4-34899 Test Key for S4-34800 Range of MCP Pack of 25 Gent S4-34899 Test Key for S4-34800 Range of MCP Pack of 25The S4-34899 is a pack of call point keys for use with the new type Gent Vigilon Call Points.These keys allow the user to perform a test on a call point without breaking the glass in the unit. They also allow the front of the call point to be removed to allow access to the terminal connections within the call point.Key FeaturesPack of 25 GBP 45.01 1
Gent S4T-711-VAD-HPR S4 SELF TEST Dual Optical Heat Sensor amp High Power Red VAD Gent S4T-711-VAD-HPR S4 SELF TEST Dual Optical Heat Sensor High Power Red VADThis device has a new IP21 external moulding new detector chamber design anda dual microprocessor PCB. This design delivers even better smoke detection andvoice storage capacity. In addition the award-winning Self-Test feature allows boththe heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Available in a large range of multi-sensorPart-23 VAD and sounder voice options. Enables discrete functional testing andvisual inspection of the fire alarm systemby reducing the engineer toolset to justa mobile device phone or tablet. Nomore impact on building occupiers. Tests both the heat and smokesensors by heating the thermistorand introducing small amounts ofsmoke into the detection chamber. Gently blows the smoke out of thedetection chamber and smoke entrypoints to ensure they are not blocked. Flexible testing options allow the engineerto test in different ways single devicedetection zone loops panels. Allows up to 6 devices to be tested atonce per loop and any number of loopscan be tested simultaneously makingthe functional testing incredibly fast. Device testing is fast enough to allowup to 4 functional tests to be performedper year for the lifespan of the device. Eliminates all access issues whendetector testing ensuring 100functional testing is achieved. Allows the system to remain active whilsttesting as each detector is only offline for60 seconds and outputs are not generated. Any fires detected outside of thedevices performing Self-Test will stopthe Self-Test process and operatethe fire systems Cause Effect. Allows the engineer to easily locatethe detector using the App and BLEto check the device number labelzone description and detector type. Allows simple device updates tobe performed through the Appincluding the correction of inaccuratedevice labels and loop mapping. The app and BLE handshakeverifies that the engineer has beenwithin visual inspection range. Optional Inspection prompt LEDs onthe device let the engineer know whatSelf-Test devices need to be visuallyinspected and will automatically turn offwhen the visual inspection is complete. Engineers can spend more time digitallycapturing non-compliance issues andadvising how to resolve them. Thisincludes any issues causing false alarms. Test Fire LED option in the App allowsthe fire LED to be tested a pendingBS5839-1 testing requirement. Thisfeature can additionally confirm thatthey are inspecting the correct device. The CLSS App allows the engineerto simulate a fire and test theCause Effect logic. The CLSS App also allows theCause Effect to be triggeredthrough a successful Self-Testoperation allowing a witness test tobe performed using real smoke. GBP 192.79 1
Gent S4T-720-V-VAD-HPR S4 SELF TEST Heat Sensor amp Voice Sounder amp High Power Red VAD Gent S4T-720-V-VAD-HPR S4 SELF TEST Heat Sensor Voice Sounder High Power Red VADThis device has a new IP21 external moulding new detector chamber design anda dual microprocessor PCB. This design delivers even better smoke detection andvoice storage capacity. In addition the award-winning Self-Test feature allows boththe heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Available in a large range of multi-sensorPart-23 VAD and sounder voice options. Enables discrete functional testing andvisual inspection of the fire alarm systemby reducing the engineer toolset to justa mobile device phone or tablet. Nomore impact on building occupiers. Tests both the heat and smokesensors by heating the thermistorand introducing small amounts ofsmoke into the detection chamber. Gently blows the smoke out of thedetection chamber and smoke entrypoints to ensure they are not blocked. Flexible testing options allow the engineerto test in different ways single devicedetection zone loops panels. Allows up to 6 devices to be tested atonce per loop and any number of loopscan be tested simultaneously makingthe functional testing incredibly fast. Device testing is fast enough to allowup to 4 functional tests to be performedper year for the lifespan of the device. Eliminates all access issues whendetector testing ensuring 100functional testing is achieved. Allows the system to remain active whilsttesting as each detector is only offline for60 seconds and outputs are not generated. Any fires detected outside of thedevices performing Self-Test will stopthe Self-Test process and operatethe fire systems Cause Effect. Allows the engineer to easily locatethe detector using the App and BLEto check the device number labelzone description and detector type. Allows simple device updates tobe performed through the Appincluding the correction of inaccuratedevice labels and loop mapping. The app and BLE handshakeverifies that the engineer has beenwithin visual inspection range. Optional Inspection prompt LEDs onthe device let the engineer know whatSelf-Test devices need to be visuallyinspected and will automatically turn offwhen the visual inspection is complete. Engineers can spend more time digitallycapturing non-compliance issues andadvising how to resolve them. Thisincludes any issues causing false alarms. Test Fire LED option in the App allowsthe fire LED to be tested a pendingBS5839-1 testing requirement. Thisfeature can additionally confirm thatthey are inspecting the correct device. The CLSS App allows the engineerto simulate a fire and test theCause Effect logic. The CLSS App also allows theCause Effect to be triggeredthrough a successful Self-Testoperation allowing a witness test tobe performed using real smoke. GBP 189.40 1
Gent S4T-711-V-VAD-HPR S4 SELF TEST Dual Optical Heat Sensor amp Voice Sounder amp High Power Red Gent S4T-711-V-VAD-HPR S4 SELF TEST Dual Optical Heat Sensor Voice Sounder High Power RedThis device has a new IP21 external moulding new detector chamber design anda dual microprocessor PCB. This design delivers even better smoke detection andvoice storage capacity. In addition the award-winning Self-Test feature allows boththe heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Available in a large range of multi-sensorPart-23 VAD and sounder voice options. Enables discrete functional testing andvisual inspection of the fire alarm systemby reducing the engineer toolset to justa mobile device phone or tablet. Nomore impact on building occupiers. Tests both the heat and smokesensors by heating the thermistorand introducing small amounts ofsmoke into the detection chamber. Gently blows the smoke out of thedetection chamber and smoke entrypoints to ensure they are not blocked. Flexible testing options allow the engineerto test in different ways single devicedetection zone loops panels. Allows up to 6 devices to be tested atonce per loop and any number of loopscan be tested simultaneously makingthe functional testing incredibly fast. Device testing is fast enough to allowup to 4 functional tests to be performedper year for the lifespan of the device. Eliminates all access issues whendetector testing ensuring 100functional testing is achieved. Allows the system to remain active whilsttesting as each detector is only offline for60 seconds and outputs are not generated. Any fires detected outside of thedevices performing Self-Test will stopthe Self-Test process and operatethe fire systems Cause Effect. Allows the engineer to easily locatethe detector using the App and BLEto check the device number labelzone description and detector type. Allows simple device updates tobe performed through the Appincluding the correction of inaccuratedevice labels and loop mapping. The app and BLE handshakeverifies that the engineer has beenwithin visual inspection range. Optional Inspection prompt LEDs onthe device let the engineer know whatSelf-Test devices need to be visuallyinspected and will automatically turn offwhen the visual inspection is complete. Engineers can spend more time digitallycapturing non-compliance issues andadvising how to resolve them. Thisincludes any issues causing false alarms. Test Fire LED option in the App allowsthe fire LED to be tested a pendingBS5839-1 testing requirement. Thisfeature can additionally confirm thatthey are inspecting the correct device. The CLSS App allows the engineerto simulate a fire and test theCause Effect logic. The CLSS App also allows theCause Effect to be triggeredthrough a successful Self-Testoperation allowing a witness test tobe performed using real smoke. GBP 235.25 1
Gent S4TB-711-V-VAD-HPR S4 SELF TEST Black Dual Optical Heat Sensor amp Voice Sounder amp High Power Red VAD - Black Gent S4TB-711-V-VAD-HPR S4 SELF TEST Black Dual Optical Heat Sensor Voice Sounder High Power Red VAD - BlackThis device has a new IP21 external moulding new detector chamber design anda dual microprocessor PCB. This design delivers even better smoke detection andvoice storage capacity. In addition the award-winning Self-Test feature allows boththe heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Available in a large range of multi-sensorPart-23 VAD and sounder voice options. Enables discrete functional testing andvisual inspection of the fire alarm systemby reducing the engineer toolset to justa mobile device phone or tablet. Nomore impact on building occupiers. Tests both the heat and smokesensors by heating the thermistorand introducing small amounts ofsmoke into the detection chamber. Gently blows the smoke out of thedetection chamber and smoke entrypoints to ensure they are not blocked. Flexible testing options allow the engineerto test in different ways single devicedetection zone loops panels. Allows up to 6 devices to be tested atonce per loop and any number of loopscan be tested simultaneously makingthe functional testing incredibly fast. Device testing is fast enough to allowup to 4 functional tests to be performedper year for the lifespan of the device. Eliminates all access issues whendetector testing ensuring 100functional testing is achieved. Allows the system to remain active whilsttesting as each detector is only offline for60 seconds and outputs are not generated. Any fires detected outside of thedevices performing Self-Test will stopthe Self-Test process and operatethe fire systems Cause Effect. Allows the engineer to easily locatethe detector using the App and BLEto check the device number labelzone description and detector type. Allows simple device updates tobe performed through the Appincluding the correction of inaccuratedevice labels and loop mapping. The app and BLE handshakeverifies that the engineer has beenwithin visual inspection range. Optional Inspection prompt LEDs onthe device let the engineer know whatSelf-Test devices need to be visuallyinspected and will automatically turn offwhen the visual inspection is complete. Engineers can spend more time digitallycapturing non-compliance issues andadvising how to resolve them. Thisincludes any issues causing false alarms. Test Fire LED option in the App allowsthe fire LED to be tested a pendingBS5839-1 testing requirement. Thisfeature can additionally confirm thatthey are inspecting the correct device. The CLSS App allows the engineerto simulate a fire and test theCause Effect logic. The CLSS App also allows theCause Effect to be triggeredthrough a successful Self-Testoperation allowing a witness test tobe performed using real smoke. GBP 319.33 1
Gent 800371 Conventional S-Quad Optical Smoke Detector Gent 800371 Conventional S-Quad Optical Smoke DetectorThe new ES Detect range S Quad conventional has been developed to operate with the Xenex panel. The ES Detect range replaces the Vision 2020 range.The Gent detector is a scattered-light smoke detector for reliable early detection of fires. Fire detector with decentralized intelligence automatic function self-test automatic environmental adaptation alarm and operating data storage and alarm display.A remote indicator can also be connected.Key FeaturesUniform response sensitivity of the detector for all different types of fire for the multi-sensor detectorsLarge distance between signal and interference magnitudes due to special sensor and electronics design for suppressing electromagnetic influencesAutomatic adaptation to varying environmental influencesElectronic compensation of long-term influences of contamination or aging GBP 27.44 1
Gent 800177 Conventional S-Quad High Temperature Fixed Heat Detector Gent 800177 Conventional S-Quad High Temperature Fixed Heat DetectorThe ES Detect range S Quad conventional has been developed to operate with the Xenex panel. The ES Detect range replaces the Vision 2020 range.The heat detector is an automatic heat detector with fast semiconductor sensor for reliable detection of fires with distinctive heat. Fire detector with decentralized intelligence automatic function self-test alarm and operations data storage and alarm display. A remote indicator can also be connected.Key FeaturesUniform response sensitivity of the detector for all different types of fire for the multi-sensor detectorsLarge distance between signal and interference magnitudes due to special sensor and electronics design for suppressing electromagnetic influencesAutomatic adaptation to varying environmental influencesElectronic compensation of long-term influences of contamination or aging GBP 41.28 1
Gent 800271 Conventional S-Quad Rate of Rise Heat Detector Gent 800271 Conventional S-Quad Rate of Rise Heat DetectorThe ES Detect range S Quad conventional has been developed to operate with the Xenex panel. The ES Detect range replaces the Vision 2020 range.Automatic heat detector with fast semiconductor sensor for reliable detection of fires with rapid temperature rise and integrated maximum value function for the recognition of fires with slow temperature rises. Fire detector with decentralized intelligence automatic function self-test alarm and operations data storage and alarm display. A remote indicator can also be connected.Key FeaturesUniform response sensitivity of the detector for all different types of fire for the multi-sensor detectorsLarge distance between signal and interference magnitudes due to special sensor and electronics design for suppressing electromagnetic influencesAutomatic adaptation to varying environmental influencesElectronic compensation of long-term influences of contamination or aging GBP 27.52 1
Gent S4-34740 Beam Sensor Pair Transmitter and Receiver Excluding Bracket and Base Gent S4-34740 Beam Sensor Pair Transmitter and Receiver Excluding Bracket and BaseGent S4-34740 S-Quad Addressable Loop Powered Beam Sensor Pair provides an enhanced solution for linear beam detection for applications where Gent S4 Vigilon point detection is either not practical or economic.Powered and controlled via the loop the beam is a market leading device with features such as one man alignment and commissioning which is achieved using the auto gain setting this ensure the optimum alignment is reached.Maintenance of the beam is enhanced with a key operated test feature which simulates the obscuration of the beam in a fire.The Gent loop powered beam is certified to EN54 parts 12 and 17. Compatible with the full range of Vigilon and Nano control panels the S-Quad beam uses the panel software to ensure a fast response to fire while offering software filters to reduce the number of unwanted alarms.Key FeaturesS-Quad Beam pairs are loop powered supporting 16 pairs per loopEach beam can be set to one of 6 sensitivity states to provide a best fit for individual applicationsThe beam provides increased resilience to interference from the sun and other light sourcesRemote key switch provides test facility at ground level without the need to gain access to beams mounted in high areasThe beam incorporates an LED array to indicate signal strength allowing accurate alignment during one person commissioningOptimum sensitivity is maintained by automatic gain setting triggered at the beam during alignmentThe optical lens design is intended to minimise build-up of dust to reduce the maintenance and cleaning requiredThe S-Quad beam is compatible with early versions of the Vigilon Beam using the S-Quad programming base avoiding the need to upgrade to latest control software GBP 871.37 1
Gent S4-34741 Beam Sensor Transmitter Gent S4-34741 Beam Sensor TransmitterThe S4-34741 from Gent is a Beam Sensor Emitter.Vigilons loop powered technology allows up to 16 beam pairs to be connected to the same loop circuit each covering a distance of up to 100m without the need for an external Power Supply Unit wiring or interfacing.Compatible with the full range of Vigilon and Nano control panels the S-Quad beam uses the panel software to ensure a fast response to fi re while offering software filters to reduce the number of unwanted alarms.What is a Beam SensorA beam sensor works when theemittersends out abeamof light most often a pulsed infrared visible red or laser that diffuses in all directions filling a detection area. The target then enters the area and deflects part of thebeamback to the receiver.If anything is detected it will signal an alarm.Key FeaturesEach beam can be set to one of 6 sensitivity states to provide a best fi t for individual applicationsThe beam provides increased resilience to interference from the sun and other light sourcesRemote key switch provides test facility at ground level without the need to gain access to beams mounted in high areasThe beam incorporates an LED array to indicate signal strength allowing accurate alignment during one person commissioningOptimum sensitivity is maintained by automatic gain setting triggered at the beam during alignmentThe optical lens design is intended to minimise build up of dust to reduce the maintenance and cleaning requiredThe S-Quad beam is compatible with early versions of the Vigilon Beam using the S-Quad programming base avoiding the need to upgrade to latest control software GBP 755.02 1
Gent 8 Zone Auto Reset Fire Alarm Control Panel Gent 8 Zone Auto Reset Fire Alarm Control Panel, Auto Reset: Yes, Control Types: Cancel, Disable Zone, Fault Buzzer, Lamp Test, Reset, Silence Alarms, Sound Alarms, MPN: 75585-08 GBP 362.50 1
Gent 2 Zone Auto Reset Fire Alarm Control Panel Gent 2 Zone Auto Reset Fire Alarm Control Panel, Auto Reset: Yes, Control Types: Cancel, Disable Zone, Fault Buzzer, Lamp Test, Reset, Silence Alarms, Sound Alarms, MPN: 75585-02 GBP 213.20 1
Gent Programmer Base for S4 and S3 Voice Sounder Devices S4-BASE-PROGRAM Gent Programmer Base for S4 and S3 Voice Sounder Devices S4-BASE-PROGRAMThis S-Quad programming tool S4-BASE-PROGRAM is used to test and programme S-Quad speech products. GBP 284.51 1
Gent 704952 Yellow Fascia for Key Switch MCP For Use With S4-34807 Gent 704952 Yellow Fascia for Key Switch MCP For Use With S4-34807The Gent 704952 is a Fascia designed for use with the Gent S4-34807 Vigilon Key-Switch Call Point.Key FeaturesComes in the colour yellowFlat designPlug-in connection terminalsOptional terminalTriple key function test open reset GBP 36.61 1
Gent 704982 Yellow Surface Mount Back Box for Key Switch MCP For Use With S4-34807 Gent 704982 Yellow Surface Mount Back Box for Key Switch MCP For Use With S4-34807The 704982 is a Surface Mount Back Box designed for use with the Gent S4-34807 Vigilon Key-Switch Call Point.Key FeaturesComes in the colour yellowFlat designPlug-in connection terminalsOptional terminalTriple key function test open reset GBP 21.16 1