91 results (0,14317 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Global Fire CHAMELEON-REP Chameleon Control Repeater cw RS422 Network Card

Global Fire CHAMELEON-REPBLK Chameleon Control Repeater cw RS422 Network Card - Black

Global Fire Equipment GFE-ADII GFE Addressable Stand-Alone Loop Isolator

Global Fire Equipment GFE-MIO Mains Switching IO Module CW Isolator

Global Fire OCTO-4 Loop Control Panel

Global Fire OCTO-4 Loop Control Panel

Global Fire OCTO-4 Loop Control PanelThe OCTO Fire Alarm Control Panel is built on the pedigree of the worldwide known JUNO NET. Now featuring a fully peer-to-peer multi-master networking solution.This new Chameleon Network solution enables extreme resilience in very large distributed systems. On a Chameleon Network system each network NODE has in its internal configuration memory the whole system information i.e. in the unlikely event of a communication loss there is no performance degradation of individual NODE.The network layout is usually configured in a closed loop or having physical multi-paths for communications redundancy which can use either RS422 or Fibre-Optic mediums.It can also use Ethernet interfaces which can use the existing networking infrastructure.A Chameleon Network can accommodate up to 32 NODE. Each OCTO panel can support from 1 to 4 addressable loops giving a total of 128 loops in a single systemNaturally it also supports remote access with our proprietary ODYSSEY Graphics Interface as well as integration with third party Building Management Systems through a Modbus output.The graphic backlit LCD display accommodates any type of custom characters or graphic symbols allowing multi-language support as well as pictorial and customisable elements.Housed in an aluminium back box with a reversible plastic lid it comprises a PSU a Front End Display for visualisation of the CI equipment status a NODE unit with the loop card fitted and networking interfaces if necessary.For each 4 loops there is space for installing up to 12 AH 24V DC Sealed Lead Acid backup batteries more than enough to provide up to 24 H battery supply to the NODE and ZEOS associated devices which boast extremely low current consumption.Take into account that all networked panels share the complete system knowledge. On a multi OCTO networked panels as far as the network architecture is concerned if no human-machine Interface is needed at a specific location instead of using a complete OCTO panel with display built in a simple NODE panel can be used.By having the same 4 Loops available and housed in the same aluminium back box without the Front End Display built in the lid the NODE offers the possibility to extend the system keeping the human interface access only available at specific locations.In addition to this each NODE has provision to communicate with a remote Repeater unit using any of the networking interfaces.The Cause and Effect programming as well as customer specific Configurations can be uploaded to any OCTO panel in the network using the CHAMELEON CONNECTOR software tool. This is done by USB connection. Later the updated panel can broadcast the same configuration to all other Chameleon Network panels.Key Features1 to 4 loops panelUp to 250 devices per loop 125 address limitUp to 95 VULCAN 2 addressable ultra low current base sounders 32 address limitSupports connection to Repeaters via RS422 Fibre-Optic or TCPIPNetworked system up to 128 loopsChameleon Peer-to-Peer Advanced Networking Protocol with up to 32 NODE32 individually programmable sounder addressesSupport of Non-European languages Mandarin Arabic Hindu Urdu Farsi etc.Full Self-Addressable Devices supportBuilt in Fire Fault relays2 conventional alarm outputs individually programmableDetection loops monitored for integrity384 fully programmable multi loop zones512 fully programmable sounder groups512 IO groupsEvent log rolling 10000 entriesRemovable Chassis

GBP 1446.26
1

Global Fire OCTO-2 OCTO 2 Loop Control Panel

Global Fire OCTO-2 OCTO 2 Loop Control Panel

Global Fire OCTO-2 OCTO 2 Loop Control PanelThe OCTO Fire Alarm Control Panel is built on the pedigree of the worldwide known JUNO NET. Now featuring a fully peer-to-peer multi-master networking solution.This new Chameleon Network solution enables extreme resilience in very large distributed systems. On a Chameleon Network system each network NODE has in its internal configuration memory the whole system information i.e. in the unlikely event of a communication loss there is no performance degradation of individual NODE.The network layout is usually configured in a closed loop or having physical multi-paths for communications redundancy which can use either RS422 or Fibre-Optic mediums.It can also use Ethernet interfaces which can use the existing networking infrastructure.A Chameleon Network can accommodate up to 32 NODE. Each OCTO panel can support from 1 to 4 addressable loops giving a total of 128 loops in a single systemNaturally it also supports remote access with our proprietary ODYSSEY Graphics Interface as well as integration with third party Building Management Systems through a Modbus output.The graphic backlit LCD display accommodates any type of custom characters or graphic symbols allowing multi-language support as well as pictorial and customisable elements.Housed in an aluminium back box with a reversible plastic lid it comprises a PSU a Front End Display for visualisation of the CI equipment status a NODE unit with the loop card fitted and networking interfaces if necessary.For each 4 loops there is space for installing up to 12 AH 24V DC Sealed Lead Acid backup batteries more than enough to provide up to 24 H battery supply to the NODE and ZEOS associated devices which boast extremely low current consumption.Take into account that all networked panels share the complete system knowledge. On a multi OCTO networked panels as far as the network architecture is concerned if no human-machine Interface is needed at a specific location instead of using a complete OCTO panel with display built in a simple NODE panel can be used.By having the same 4 Loops available and housed in the same aluminium back box without the Front End Display built in the lid the NODE offers the possibility to extend the system keeping the human interface access only available at specific locations.In addition to this each NODE has provision to communicate with a remote Repeater unit using any of the networking interfaces.The Cause and Effect programming as well as customer specific Configurations can be uploaded to any OCTO panel in the network using the CHAMELEON CONNECTOR software tool. This is done by USB connection. Later the updated panel can broadcast the same configuration to all other Chameleon Network panels.Key Features1 to 4 loops panelUp to 250 devices per loop 125 address limitUp to 95 VULCAN 2 addressable ultra low current base sounders 32 address limitSupports connection to Repeaters via RS422 Fibre-Optic or TCPIPNetworked system up to 128 loopsChameleon Peer-to-Peer Advanced Networking Protocol with up to 32 NODE32 individually programmable sounder addressesSupport of Non-European languages Mandarin Arabic Hindu Urdu Farsi etc.Full Self-Addressable Devices supportBuilt in Fire Fault relays2 conventional alarm outputs individually programmableDetection loops monitored for integrity384 fully programmable multi loop zones512 fully programmable sounder groups512 IO groupsEvent log rolling 10000 entriesRemovable Chassis

GBP 1157.02
1

Global Fire Equipment OCTO-4BLK 4 Loop Control Panel - Anthracite

Global Fire Equipment OCTO-4BLK 4 Loop Control Panel - Anthracite

Global Fire Equipment OCTO-4BLK 4 Loop Control Panel - AnthraciteThe OCTO Fire Alarm Control Panel is built on the pedigree of the worldwide known JUNO NET. Now featuring a fully peer-to-peer multi-master networking solution.This new Chameleon Network solution enables extreme resilience in very large distributed systems. On a Chameleon Network system each network NODE has in its internal configuration memory the whole system information i.e. in the unlikely event of a communication loss there is no performance degradation of individual NODE.The network layout is usually configured in a closed loop or having physical multi-paths for communications redundancy which can use either RS422 or Fibre-Optic mediums.It can also use Ethernet interfaces which can use the existing networking infrastructure.A Chameleon Network can accommodate up to 32 NODE. Each OCTO panel can support from 1 to 4 addressable loops giving a total of 128 loops in a single systemNaturally it also supports remote access with our proprietary ODYSSEY Graphics Interface as well as integration with third party Building Management Systems through a Modbus output.The graphic backlit LCD display accommodates any type of custom characters or graphic symbols allowing multi-language support as well as pictorial and customisable elements.Housed in an aluminium back box with a reversible plastic lid it comprises a PSU a Front End Display for visualisation of the CI equipment status a NODE unit with the loop card fitted and networking interfaces if necessary.For each 4 loops there is space for installing up to 12 AH 24V DC Sealed Lead Acid backup batteries more than enough to provide up to 24 H battery supply to the NODE and ZEOS associated devices which boast extremely low current consumption.Take into account that all networked panels share the complete system knowledge. On a multi OCTO networked panels as far as the network architecture is concerned if no human-machine Interface is needed at a specific location instead of using a complete OCTO panel with display built in a simple NODE panel can be used.By having the same 4 Loops available and housed in the same aluminium back box without the Front End Display built in the lid the NODE offers the possibility to extend the system keeping the human interface access only available at specific locations.In addition to this each NODE has provision to communicate with a remote Repeater unit using any of the networking interfaces.The Cause and Effect programming as well as customer specific Configurations can be uploaded to any OCTO panel in the network using the CHAMELEON CONNECTOR software tool. This is done by USB connection. Later the updated panel can broadcast the same configuration to all other Chameleon Network panels.Key Features1 to 4 loops panelUp to 250 devices per loop 125 address limitUp to 95 VULCAN 2 addressable ultra low current base sounders 32 address limitSupports connection to Repeaters via RS422 Fibre-Optic or TCPIPNetworked system up to 128 loopsChameleon Peer-to-Peer Advanced Networking Protocol with up to 32 NODE32 individually programmable sounder addressesSupport of Non-European languages Mandarin Arabic Hindu Urdu Farsi etc.Full Self-Addressable Devices supportBuilt in Fire Fault relays2 conventional alarm outputs individually programmableDetection loops monitored for integrity384 fully programmable multi loop zones512 fully programmable sounder groups512 IO groupsEvent log rolling 10000 entriesRemovable ChassisBlack version

GBP 1518.88
1

Global Fire OCTO-2BLK OCTO 2 Loop Control Panel - Black

Global Fire OCTO-2BLK OCTO 2 Loop Control Panel - Black

Global Fire OCTO-2BLK OCTO 2 Loop Control Panel - BlackThe OCTO Fire Alarm Control Panel is built on the pedigree of the worldwide known JUNO NET. Now featuring a fully peer-to-peer multi-master networking solution.This new Chameleon Network solution enables extreme resilience in very large distributed systems. On a Chameleon Network system each network NODE has in its internal configuration memory the whole system information i.e. in the unlikely event of a communication loss there is no performance degradation of individual NODE.The network layout is usually configured in a closed loop or having physical multi-paths for communications redundancy which can use either RS422 or Fibre-Optic mediums.It can also use Ethernet interfaces which can use the existing networking infrastructure.A Chameleon Network can accommodate up to 32 NODE. Each OCTO panel can support from 1 to 4 addressable loops giving a total of 128 loops in a single systemNaturally it also supports remote access with our proprietary ODYSSEY Graphics Interface as well as integration with third party Building Management Systems through a Modbus output.The graphic backlit LCD display accommodates any type of custom characters or graphic symbols allowing multi-language support as well as pictorial and customisable elements.Housed in an aluminium back box with a reversible plastic lid it comprises a PSU a Front End Display for visualisation of the CI equipment status a NODE unit with the loop card fitted and networking interfaces if necessary.For each 4 loops there is space for installing up to 12 AH 24V DC Sealed Lead Acid backup batteries more than enough to provide up to 24 H battery supply to the NODE and ZEOS associated devices which boast extremely low current consumption.Take into account that all networked panels share the complete system knowledge. On a multi OCTO networked panels as far as the network architecture is concerned if no human-machine Interface is needed at a specific location instead of using a complete OCTO panel with display built in a simple NODE panel can be used.By having the same 4 Loops available and housed in the same aluminium back box without the Front End Display built in the lid the NODE offers the possibility to extend the system keeping the human interface access only available at specific locations.In addition to this each NODE has provision to communicate with a remote Repeater unit using any of the networking interfaces.The Cause and Effect programming as well as customer specific Configurations can be uploaded to any OCTO panel in the network using the CHAMELEON CONNECTOR software tool. This is done by USB connection. Later the updated panel can broadcast the same configuration to all other Chameleon Network panels.Key Features1 to 4 loops panelUp to 250 devices per loop 125 address limitUp to 95 VULCAN 2 addressable ultra low current base sounders 32 address limitSupports connection to Repeaters via RS422 Fibre-Optic or TCPIPNetworked system up to 128 loopsChameleon Peer-to-Peer Advanced Networking Protocol with up to 32 NODE32 individually programmable sounder addressesSupport of Non-European languages Mandarin Arabic Hindu Urdu Farsi etc.Full Self-Addressable Devices supportBuilt in Fire Fault relays2 conventional alarm outputs individually programmableDetection loops monitored for integrity384 fully programmable multi loop zones512 fully programmable sounder groups512 IO groupsEvent log rolling 10000 entriesRemovable ChassisColour Black

GBP 1219.99
1

Global Fire GFE-A-REM-IND GFE Advanced Remote Indicator

Global Fire Equipment MAMYEL-VAD Manually Addressed Module for Conventional VADs

Global Fire Equipment GFE-IO-3 Addressable 3-Channel IO Module CW Isolator

GBP 82.61
1

Global Fire Equipment GFE-IO-2 Addressable 2-Channel IO Module CW Isolator

GBP 65.52
1

Global Fire Equipment GFE-IO-1 Addressable 1-Channel IO Module CW Isolator

GBP 48.43
1

Global Fire Equipment GEKKO-2BLK GEKKO 2 Loop Control Panel Anthracite

Global Fire Equipment GEKKO-2BLK GEKKO 2 Loop Control Panel Anthracite

Global Fire Equipment GEKKO-2BLK GEKKO 2 Loop ControlPanel AnthraciteThe GEKKO Fire Alarm Control Panel is the successor to GFEswell-known JUNIOR V4 panel.The GEKKO can have from 1 to 4 addressable loops. It ishoused in a functional ABS plastic enclosure with only two screws used toclose and secure the lid.The new graphic backlit LCD display can accommodate any typeof custom characters or graphic symbols allowing multi-language support aswell as visual and customisable elements.It can communicate with our proprietary ODYSSEY GraphicsInterface as well as with third party Building Management Systems through aModbus output. It is also capable of communicating with a repeater unit usingany of the networking interfaces of the CHAMELEON protocol.Inside the cabinet there is space to install up to 7 AH 24VDC Sealed Lead Acid backup batteries providing battery supply to the GEKKO andZEOS associated devices which boast extremely low energy consumption.The Cause and Effect programming as well as allcustomer-specific configuration is introduced in the GEKKO using the CHAMELEONCONNECTOR software which is then downloaded to the flash memory of the unit.Key FeaturesSuccessor to GFEs JUNIOR V4 panel1 to 4 loop panel 2 loop cards installedSupports connection to Repeaters via RS422 Fibre-Optic orTCPIPNetworkable panel compatible with OCTO and NODE range ofpanelsUp to 250 devices per loop only 125 addresses availableUp to 95 VULCAN 2 addressable ultra low current basesounders 32 address limit32 individually programmable sounder addressesFull self-addressable devices support2 Fire output relays change-over and 1 fault relay NC -opens on fault2 conventional alarm outputs Individually programmableBoth detection loops monitored for integrity512 fully programmable sounder and IO groups384 fully programmable zonesEvent log rolling 10000 entriesAvailable only with ZEOS protocolCompatible with all GFE manufactured ancillary modulesBacklit graphical LCD display of 240x64 pixelsProgramming by integrated keypad or Loader PC softwareMultiple language support menu selectableIntegrated 16 zone LED fire zone indicationEN54-13 EN54-2 EN54-4 1328-CPR-0737 certified

GBP 671.47
1

Global Fire Valkyrie ASI IP65 Addressable Red Sounder with Isolator

Global Fire Valkyrie ASBI IP65 Addressable Red Sounder Beacon with Isolator

Global Fire Equipment VULCAN2-ABI Vulcan 2 ABI Addressable Base Beacon with Isolator

Global Fire Equipment VULCAN2-ABI Vulcan 2 ABI Addressable Base Beacon with Isolator

Global Fire Equipment VULCAN2-ABI Vulcan 2 ABI Addressable Base Beacon with IsolatorThe addressable VULCAN 2 A is available as an Addressable Beacon which may be field configured to operate in either SHADOW or AUXILIARY modes. There are also versions available incorporating a loop isolator. Up to 64 VULCAN 2 A Beacon devices can be connected to a single Loop depending on Loop Loading. All VULCAN 2 A devices have dip-switch Address setting while Tone and Mode selection is via a jumper. There is also a potentiometer which may be used to adjust the sound level if required. Normally the VULCAN 2 A will be used in conjunction with a detector however a lid is available as an option for the VULCAN 2 A.Shadow Beacon A Shadow Beacon does not have an individual address thus freeing up addresses for more detection devices. Shadow Beacons do not report back to the control panel so their presence on the Loop is not monitored. Auxiliary Beacon When the VULCAN 2 A is configured as an Auxiliary device it shares the same address as the detector with which it is co-located. When operating in this mode the VULCAN 2 A monitors the Address loop for the command from the control Panel to the detector to illuminate its LED. When this command is received the VULCAN 2 A is also activated.If a Fire is confirmed the remaining sounders may be activated using the Evacuate command. This reduces the inconvenience to other guests in the event of a false alarm while at the same time giving early warning to the occupant of the room in the case of an actual Fire event. Pressing Sounder silence at the panel silences all active sounders. The maximum number of Auxiliary Beacons is 63 and they can be allocated between address 1 and 63.

GBP 40.98
1

Global Fire VULCAN2-ABIBLK VULCAN 2 Addressable Base Beacon cw Isolator - Black

Global Fire VULCAN2-ABIBLK VULCAN 2 Addressable Base Beacon cw Isolator - Black

Global Fire VULCAN2-ABIBLK VULCAN 2 Addressable Base Beacon cw Isolator - BlackThe addressable VULCAN 2 A is available as an Addressable Beacon which may be field configured to operate in either SHADOW or AUXILIARY modes. There are also versions available incorporating a loop isolator. Up to 64 VULCAN 2 A Beacon device can be connected to a single Loop depending on Loop Loading. All VULCAN 2 A devices have dip-switch Address setting while Tone and Mode selection is via a jumper. There is also a potentiometer which may be used to adjust the sound level if required. Normally the VULCAN 2 A will be used in conjunction with a detector however a lid is available as an option for the VULCAN 2 A.Shadow Beacon A Shadow Beacon does not have an individual address thus freeing up addresses for more detection devices. Shadow Beacons do not report back to the control panel so their presence on the Loop is not monitored. Auxiliary Beacon When the VULCAN 2 A is configured as an Auxiliary device it shares the same address as the detector with which it is co-located. When operating in this mode the VULCAN 2 A monitors the Address loop for the command from the control Panel to the detector to illuminate its LED. When this command is received the VULCAN 2 A is also activated.If a Fire is confirmed the remaining sounders may be activated using the Evacuate command. This reduces the inconvenience to other guests in the event of a false alarm while at the same time giving early warning to the occupant of the room in the case of an actual Fire event. Pressing Sounder silence at the panel silences all active sounders. The maximum number of Auxiliary Beacons is 63 and they can be allocated between address 1 and 63.

GBP 61.48
1

Global Fire GEKKO-0 Loop Control Panel

Global Fire GEKKO-0 Loop Control Panel

Global Fire GEKKO-0 Loop Control PanelThe GEKKO Fire Alarm Control Panel is the successor of the enormously popular GFE JUNIOR panel.The GEKKO can have from 1 to 4 addressable loops. It is housed in a functional ABS plastic enclosure with only two screws used to close and secure the lid.The new graphic backlit LCD display can accommodate any type of custom characters or graphic symbols allowing multi-language support as well as pictorial and customisable elements.It can naturally also communicate with our proprietary ODYSSEY Graphics Interface as well as with third party Building Management Systems through a Modbus output. It is also capable to communicate with a Repeater unit using any of the networking interfaces of the CHAMELEON protocol.Inside the cabinet there is space for installing up to 7 AH 24V DC Sealed Lead Acid backup batteries providing battery supply to the GEKKO and ZEOS associated devices which boast extremely low current consumption.The Cause and Effect programming as well as all customer specific configuration is introduced in the GEKKO using the CHAMELEON CONNECTOR software which is then downloaded to the Flash Memory of the unit.Key Features1 to 4 loops panelNetworkable panel compatible with OCTO and NODE range of panelsSupports connection to Repeaters via RS422 Fibre-Optic or TCPIP250 devices per loop 125 address limitUp to 95 VULCAN 2 addressable ultra low current base sounders 32 address limit32 individually programmable sounder addressesFull Self-Addressable Devices support2 Fire output relays change-over and 1 Fault relay NC - opens on fault2 conventional alarm outputs individually programmableBoth detection loops monitored for integrity384 fully programmable zones512 fully programmable sounder groups512 IO groupsEvent log rolling 10000 entriesAvailable only with ZEOS protocolCompatible with all our own low cost ancillary modulesBacklit graphical LCD display of 240x64 pixelsProgramming by integrated keypad or Loader PC softwareMultiple language support menu selectableIntegrated 16 zone LED fire zone indication

GBP 388.99
1

Global Fire VULCAN2-ASIBLK VULCAN 2 Addressable Base Sounder cw Isolator - Black

Global Fire VULCAN2-ASIBLK VULCAN 2 Addressable Base Sounder cw Isolator - Black

Global Fire VULCAN2-ASIBLK VULCAN 2 Addressable Base Sounder cw Isolator - BlackThe addressable VULCAN 2 A is available as an Addressable Sounder Beacon which may be field configured to operate in either SHADOW or AUXILIARY modes.There are also versions available incorporating a loop isolator. Up to 64 VULCAN 2 A Sounder Beacon device can be connected to a single Loop depending on Loop Loading.All VULCAN 2 A devices have dip-switch Address setting while Tone and Mode selection is via a jumper.There is also a potentiometer which may be used to adjust the sound level if required. Normally the VULCAN 2 A will be used in conjunction with a detector however a lid is available as an option for the VULCAN 2 A.Shadow Sounder Beacon A Shadow Sounder Beacon does not have an individual address thus freeing up addresses for more detection devices.Shadow Sounder Beacons do not report back to the control panel so their presence on the Loop is not monitored.Auxiliary Sounder Beacon When the VULCAN 2 A is configured as an Auxiliary device it shares the same address as the detector with which it is co-located. When operating in this mode the VULCAN 2 A monitors the Address loop for the command from the control Panel to the detector to illuminate its LED.When this command is received the VULCAN 2 A is also activated. If a Fire is confirmed the remaining sounders may be activated using the Evacuate command.This reduces the inconvenience to other guests in the event of a false alarm while at the same time giving early warning to the occupant of the room in the case of an actual Fire event.Pressing Sounder silence at the panel silences all active sounders. The maximum number of Auxiliary Sounder Beacons is 63 and they can be allocated between address 1 and 63.

GBP 57.08
1

Global Fire Vulcan 2 ASBI Addressable White Sounder Beacon with Isolator

Global Fire Vulcan 2 ASBI Addressable White Sounder Beacon with Isolator

Global Fire Vulcan 2 ASBI Addressable White Sounder Beacon with IsolatorThe addressable VULCAN 2 A is available as an Addressable SounderBeacon which may be field configured to operate in either SHADOW or AUXILIARY modes. There are also versions available incorporating a loop isolator. Up to 64 VULCAN 2 A SounderBeacon device can be connected to a single Loop depending on Loop Loading. All VULCAN 2 A devices have dip-switch Address setting while Tone and Mode selection is via a jumper. There is also a potentiometer which may be used to adjust the sound level if required. Normally the VULCAN 2 A will be used in conjunction with a detector however a lid is available as an option for the VULCAN 2 A.Shadow SounderBeacon A Shadow SounderBeacon does not have an individual address thus freeing up addresses for more detection devices. Shadow SounderBeacons do not report back to the control panel so their presence on the Loop is not monitored. Auxiliary SounderBeacon When the VULCAN 2 A is configured as an Auxiliary device it shares the same address as the detector with which it is co-located.When operating in this mode the VULCAN 2 A monitors the Address loop for the command from the control Panel to the detector to illuminate its LED. When this command is received the VULCAN 2 A is also activated. If a Fire is confirmed the remaining sounders may be activated using the Evacuate command. This reduces the inconvenience to other guests in the event of a false alarm while at the same time giving early warning to the occupant of the room in the case of an actual Fire event. Pressing Sounder silence at the panel silences all active sounders. The maximum number of Auxiliary SounderBeacons is 63 and they can be allocated between address 1 and 63.

GBP 50.70
1

Global Fire VULCAN2-ASBIBLK VULCAN 2 Addressable Base Sounder Beacon cw Isolator - Black

Global Fire VULCAN2-ASBIBLK VULCAN 2 Addressable Base Sounder Beacon cw Isolator - Black

Global Fire VULCAN2-ASBIBLK VULCAN 2 Addressable Base Sounder Beacon cw Isolator - BlackThe addressable VULCAN 2 A is available as an Addressable Beacon which may be field configured to operate in either SHADOW or AUXILIARY modes. There are also versions available incorporating a loop isolator. Up to 64 VULCAN 2 A Beacon device can be connected to a single Loop depending on Loop Loading. All VULCAN 2 A devices have dip-switch Address setting while Tone and Mode selection is via a jumper. There is also a potentiometer which may be used to adjust the sound level if required. Normally the VULCAN 2 A will be used in conjunction with a detector however a lid is available as an option for the VULCAN 2 A.Shadow Beacon A Shadow Beacon does not have an individual address thus freeing up addresses for more detection devices. Shadow Beacons do not report back to the control panel so their presence on the Loop is not monitored. Auxiliary Beacon When the VULCAN 2 A is configured as an Auxiliary device it shares the same address as the detector with which it is co-located. When operating in this mode the VULCAN 2 A monitors the Address loop for the command from the control Panel to the detector to illuminate its LED. When this command is received the VULCAN 2 A is also activated.If a Fire is confirmed the remaining sounders may be activated using the Evacuate command. This reduces the inconvenience to other guests in the event of a false alarm while at the same time giving early warning to the occupant of the room in the case of an actual Fire event. Pressing Sounder silence at the panel silences all active sounders. The maximum number of Auxiliary Beacons is 63 and they can be allocated between address 1 and 63.

GBP 79.55
1

Zeta ZIOU230 Interface Module Loop Powered 5.0A Rating

Zeta ZIOU230 Interface Module Loop Powered 5.0A Rating

Zeta ZIOU230 Interface Module Loop Powered 5.0A RatingThe Mains IO Modules are fully monitored loop powered devices which permit the interfacing of third-party equipment with the Fire Alarm Control panel using normally open dry contact connections.The connection to the input is monitored for fault open or short circuit and Alarm conditions.The interface is used to monitor the contacts of an external system which must be interfaced to the Fire Alarm System for example a Flow Switch in a sprinkler system to indicate if the sprinklers have been activated or extinguishant level monitoring in Gas Extinguishing systems etc.Module is provided with a loop short-circuit isolator and with a voltage free single pole change over mains rated output.The output relay is always powered directly from the detection loop. It is not required to use an external 24V DC power supply. Relay operation is confirmed by an on-board red LED. An 8 way D.I.L switch is provided to configure the modules address.This value can be set in the range 1 to 125. The following programmable functions are available Input Activation Mode Delayed Input Alarm Activation Output Delayed Activation.The Simplicity CO 8 range is designed to detect monitor CO concentrations in places such as warehouses car parks tunnels and enclosed buildings where forklifts cars and delivery trucks can produce deadly amounts of carbon monoxide in high traffic areas Carbon Monoxide can accumulate in these areas and can be a serious safety and health concern.Key FeaturesFast Activation ResponseLoop PoweredFive Status LEDs providedLow Power ConsumptionModule features an integral short-circuit loop isolatorSingle mains rated relay contact

GBP 78.77
1

Global Fire GFE-MCPE-AI Addressable Call Point with Isolator