Kentec K1620203 Battery Box to Match Syncro Styling Max 17 AH Battery Surface

Kentec K1630313 Battery Box to Match Syncro Styling Max 38 AH Battery Surface

Kentec K1619911 Battery Box to Match Syncro Styling Max 24 AH Battery Surface

Kentec K1610245 Battery Box to Match Syncro Styling Max 65 AH Battery Surface

Kentec Sigma XT Extinguishant Coincidence Unit 1 Area to EN12094-1 Surface

Kentec RIM100M-3-K InputOutput Module For RIM100-E Ethernet LinkTwo Inputs To Monitor

Kentec Sigma XT 3 Zone Single Area Extinguishant Control Panel to BS EN12094-1 K11031M2

Kentec Sigma XT 3 Zone Single Area Extinguishant Control Panel to BS EN12094-1 K11031M2

Kentec SigmaK11031M2XT 3 Zone Single Area Extinguishant Control Panel to BS EN12094-1Designed and manufactured to the highest standards in a quality controlled environment and with European EN12094-1 approvals the Sigma XT K11031M2 extinguishant releasing panel offers outstanding value and performance for all small to medium fixed fire-fighting installations. With three detection zones as standard extinguishant release can be configured to activate from any combination of detection zone inputs to allow among other combinations any two from three type activations such as would be required for detection in ceiling void room and floor void applications.The extensive configuration options of the Sigma XT K11031M2 allow the functionality of the system to be extensively modified while still complying with the requirements of the controlling standard for the equipment EN12094-1 EN54-2 and EN54-4. The panel contains a large LED display to enable easy configuration and control which also displays the time remaining until extinguishant release for added user safety. The countdown timer is duplicated on up to seven remote status units to provide local indication of the extinguishant system status. With all of the electronics mounted on a single easily removable steel plate Sigma XT panels are both robust and easy to install. Sigma XT is supplied in an enclosure that matches the design and colour of the Sigma CP range.Key FeaturesApproved to EN12094-1 EN54-2 and EN54-4Three detection zones as standardAny single zone or any combinations of zones can be configured to releaseConfigurable first stage sounder delaysConfigurable detection delaysZero time delay upon manual release optionCompatible with I.S. barriersNon-latching zone input option to receive signals from other systems such as aspirating equipmentConfigurable extinguishant delays up to 60 seconds in 5 second stepsConfigurable extinguishant duration up to 5 minutes in 5 second stepsCountdown timer shows time remaining until releaseSupports up to seven four wire status indicatorsBuilt in Extract Fan control

GBP 587.21
1

Kentec K16100M3 Battery Box to Match Sigma CPXT amp Syncro AS Styling Max 17 AH Battery Surface

Kentec K16100M2 Battery Box to Match Sigma CPXT amp Syncro AS Styling Max 7 AH Battery Surface

Kentec K16100D3 Battery Box to Match Sigma CPXT amp Syncro AS Styling Max 38 AH Battery Surface

Kentec Sigma XT Extinguishant Control Panel to BS EN12094-1 2 - 8 Zone

Kentec Sigma XT Extinguishant Control Panel to BS EN12094-1 2 - 8 Zone

Kentec Sigma XT Extinguishant Control Panel to BS EN12094-1 2 - 8 ZoneSigma XT control panels are multi-area extinguishant control panels complying with EN12094-1 EN54-2 and EN54-4. Up to 8 zones of conventional detection with up to 4 extinguishant areas are available. Stand-alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals from remote fire detection control panels or addressable modules. Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface.All extinguishant areas may have up to 7 serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple 4 core cable. The versatility of the control panel can be enhanced further by the fitting of up to 7 Sigma CP Ancillary boards K580 or Sigma CP Sounder boards K461 to the RS485 serial bus. See data sheet DS39 and DS48. For compatible status units see Sigma Si data sheet DS41.Key FeaturesApproved to EN12094-1 EN54-2 and EN54-42 4 or 8 detection zones1 to 4 extinguishant areasDual extinguishant outputs for each area configurable as MainReserveFirst and second stage sounder outputs for each areaFirst and second stage volt free changeover contacts for each areaReleased volt free contact per areaFault volt free contact per areaProgrammable extinguishant delaysProgrammable output durationExtract fan controlCountdown indicator shows time until release in secondsMode select and manual release controls per areaMonitored remote manual release inputMonitored remote Hold inputMonitored remote Mode select door interlock inputMonitored remote Released pressure switch inputMonitored remote Low Pressure switch inputMonitored Abort inputSerial connection for Sigma Si status units and ancillary boards. K588Part NumberDescriptionK21021M3Sigma XT 2 Zone Extinguishant Control Panel 1 Area SurfaceK21041M3Sigma XT 4 Zone Extinguishant Control Panel 1 Area SurfaceK21042M3Sigma XT 4 Zone Extinguishant Control Panel 2 Area SurfaceK21081M3Sigma XT 8 Zone Extinguishant Control Panel 1 Area SurfaceK21082M3Sigma XT 8 Zone Extinguishant Control Panel 2 Area SurfaceK21083M4Sigma XT 8 Zone Extinguishant Control Panel 3 Area Surface larger PSU 5.25AK21084M4Sigma XT 8 Zone Extinguishant Control Panel 4 Area Surface larger PSU 5.25A

GBP 734.00
1

Kentec K2580003 Power Supply Boxed To Match Syncro Styling 10.25 Amp PSU Max 17 AH Battery Surface

Kentec K25800M3 Power Supply Boxed To match Sigma CPXT Styling 10.25 Amp PSU Max 17 AH Battery Surface

Kentec RIM100E-K Ethernet Link Module For Fire And Fault Reporting

Kentec RIM100E-K Ethernet Link Module For Fire And Fault Reporting

Kentec RIM100E-K Ethernet Link Module For Fire And Fault ReportingThe RIM100E-K provides a protocol independent Ethernet communication channel. The module supports TCP Server TCP Client UDP and UDP Server Ethernet protocols. The RIM100E-K is designed to provide a selectable RS485RS232 interface to Ethernet. The module supports airing of modules to introduce a transparent data link which can be set to monitor the link and indicate loss of the link via an output relay.The module is housed in a DIN rail mountable enclosure with LED status indication visible on the front fascia of the module. The equipment is designed to include an activity heartbeat signal for monitoring by any third-party application to which it is interfaced.The RIM100E-K is approved for use with the IVIEW fire system monitoring application tool.Key FeaturesInstalled in conjunction with the RIM100M-3-K they work together as a pair to provide bidirectional monitoring of fire and fault relays across an Ethernet linkOnce fitted the module is transparent to the userProvides a simple LAN communication channel easy to install and debugRouting of data between RS232RS485 is selectable and configured using a simple USB interfaceProduct is DIN rail mountableSerial port baud rates supported range from 300bps to 1024Kbpsstatus on data activityFront fascia LEDs system status indicationThe RIM100E-K has a built-in web page for configuring the deviceAn RJ45 status indicator light is used to provide Wireless Connectivity for remote monitoring using a Bluetooth or WiFi communication connectionDiagnostic information available via a USB interface support for Auto-MIDX function discretionary connect cross-over or direct network cable automatic switching

GBP 1022.52
1

Kentec Main Reserve Duty Extinguishant Key Switch Unit K13480M10

Kentec K85001BLU BMS License Upgrade

Kentec Line Continuity Monitoring Unit K14060

Kentec K41700FST Disabled Toilet Alarm Kit

Kentec K41400SST Type B Weather Resistant Outstation

Kentec K41700SWP Disabled Toilet Alarm Kit

Kentec DNP-R-2FFC-K Passive RS485Fibre amp Dual Fibre Dynamic Network Analyser

Kentec DNP-R-2FFC-K Passive RS485Fibre amp Dual Fibre Dynamic Network Analyser

Kentec DNP-R-2FFC-K Passive RS485Fibre Dual Fibre Dynamic Network AnalyserThe DNP-R-2FFC-K is a full fibre or hybrid copperfibre modem developed for use with fire panels in the life safety industry. The equipment is designed to improve the Quality of Service QoS of critical communication networks while operating under the performance criteria required by EN54-13 and BS5839 part 1.DNP-R-2FFC-K is designed to support dual fibre connectivity Fibre in Fibre out using the range of INS Small Form-factor Pluggable fibre optic transceivers. INS transceivers are available to support single-mode multimode and Bi-Directional fibre optic cables with distances of up to 160km.DNP-R-2FFC-K is also designed to support fibre optic to RS485 copper wiring which allows sections of an RS485 network to be converted to fibre optic cables either for enhanced transmission distances or to overcome problems with EMI Electro-Magnetic Interference.Configuring the module for fibre or RS485 fibre configurations is done through a single switch option. Simple LED indications provide detailed information regarding the communication status of each port signal quality transceiver status etc.Key FeaturesSupport Full Fibre or RS485Fibre configurationsOnly one module required per panelSimple LED status indications provide detailed diagnostic infoSupports INS Small Form-factor Pluggable SFP Fibre Optic transceiversRedundant power supply connections for increased reliabilityBaud rate selectable 9600 - 115200 bitssecDIN rail mountingSupport of single and dual port industrial equipment

GBP 1399.07
1

Kentec Anti-Tamper Resistant Vision Window M2 Size - K18002

Kentec K04000M2 Sigma CP Sounder PCB - Boxed

Kentec K04000M2 Sigma CP Sounder PCB - Boxed

Kentec K04000M2 Sigma CP Sounder PCB - BoxedThe Sigma K04000M2 is a sounder controller PCB in a steel enclosure which requires a 24v DC power source.The Kentec Sigma CP Sounder Board is compatible with all Sigma CP control panels which have operating software version V3.0 or above.The board provides 8 additional sounder outputs which can be configured as zoned 2-stage or common alarm.All sounder outputs are open and short circuit monitored and any faults on the sounder outputs will be announced at the main fire alarm panel as a sounder fault.A class change input is provided which when activated by a volt free contact closing will switch all sounder outputs on.Mains powered units require only a two core data cable from the main control panel. 24V DC versions require an additional two cores from another 24V DC source which is suitably rated to supply the total sounder current. 230V versions have their own power supply which is rated to supply sounder loads up to 5.25 Amps.Up to 7 Sounder boards can be connected to a control panel and each is allocated an address from 1 to 7 using a binary coded DIL switch. Sounder boards may be connected to the Sigma CP serial bus in addition to Sigma CP ancillary boards and Sigma CP-R repeater panels.The total length of the data cable from the main panel to the last repeater must not exceed 1200 metres. Once Sounder boards have been recognised by the main panel a fault will be announced at the main panel if any become disconnected.Key FeaturesTwo wire serial connectionUp to 7 sounder boards per system24V DC powered - in steel enclosureZoned 2-stage or common alarmAll outputs monitored for open and short circuit faultsIndividual open and short circuit fault indicatorsFully monitored by main control panelClass change input facilityUp to 8 outputs with 1A available from eachCan be connected to serial bus with Ancillary boards and repeatersPower fault input for monitoring remote power supplies

GBP 246.64
1