20 results (0,14453 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Kentec K41102SST Disabled Refuge 2 Line Central Unit

Kentec K41108FST Disabled Refuge 8 Line Central Unit with OLED Display

Kentec K41108FST Disabled Refuge 8 Line Central Unit with OLED Display

Kentec K41108FST Disabled Refuge 8 Line Central Unit with OLED DisplayThe master panel can answer or call out to each multiple or all of the Safe-Point disabled refuge outstations by activating the corresponding fascia push-buttons. Once connected full duplex conversations can take place and calls are ended by simply replacing the integrated handset.Accompanying LED indicators and an internal buzzer notify of any disabled refuse alarms raised. A fascia located momentary push-button provides lamp-test and buzzer silence functionality. Added LEDs provide power health and system fault indications.The unit is available in two installation versions allowing wiring to disabled refuge outstations to be made either radially or over a loop. Any toilet alarm kit can be wired inline with an accompanying disable refuge callanswer point.Space for 7Ah batteries is provided within the cabinet these will provide 24 3 hours standby as specified by BS5839 Part 9.The unit is available in surface or flush mount enclosure options comprising a mild steel back box with stainless steel fascia plate including a tamper resistant vision window cover.Key FeaturesRadial WiredFlush mounting8x Callanswer outstation inputsSimple handset operationAlarm indicators and internal buzzerPower on and system fault indicatorsLamp test and silence buzzer push buttonLoop or radial Outstation connection optionsEnable In Fire input to prevent non-essential callsIntegrated display to show custom alarm informationTamper resistant vision window cover

GBP 2450.78
1

Kentec K41208FST Disabled Refuge 8 Line Central Unit with OLED Display - Loop Wired Flush Mounting

Kentec K41208FST Disabled Refuge 8 Line Central Unit with OLED Display - Loop Wired Flush Mounting

Kentec K41208FST Disabled Refuge 8 Line Central Unit with OLED Display - Loop Wired Flush MountingThe Disabled Refuge 8 Line Central Unit can answer or call out to each multiple or all of the Safe-Point disabled refuge outstations by activating the corresponding fascia push-buttons. Once connected full duplex conversations can take place and calls are ended by simply replacing the integrated handset.Accompanying LED indicators and an internal buzzer notify of any disabled refuse alarms raised. A fascia located momentary push-button provides lamp-test and buzzer silence functionality. Added LEDs provide power health and system fault indications.The unit is wired to disabled refuge outstations by a loop type circuit. Any toilet alarm kit can be wired in line with an accompanying disable refuge callanswer point.There is space for 7Ah batteries provided within the cabinet these will provide 24 3 hours standby as specified by BS5839 Part 9.The unit is available in surface or flush mount enclosure options comprising a mild steel back box with stainless steel fascia plate including a tamper resistant vision window cover.Key Features8x Callanswer outstation inputsSimple handset operationAlarm indicators and internal buzzerPower on and system fault indicatorsLamp test and silence buzzer push buttonLoop or radial Outstation connection optionsEnable In Fire input to prevent non-essential callsIntegrated display to show custom alarm informationTamper resistant vision window cover

GBP 2371.82
1

Kentec K41232FST Disabled Refuge 32 Line Central Unit with OLED Display - Loop Wired Flush Mounting

Kentec K41232FST Disabled Refuge 32 Line Central Unit with OLED Display - Loop Wired Flush Mounting

Kentec K41232FST Disabled Refuge 32 Line Central Unit with OLED Display - Loop Wired Flush MountingThe Disabled Refuge 32 Line Central Unit can answer or call out to each multiple or all of the Safe-Point disabled refuge outstations by activating the corresponding fascia push-buttons. Once connected full duplex conversations can take place and calls are ended by simply replacing the integrated handset.Accompanying LED indicators and an internal buzzer notify of any disabled refuse alarms raised. A fascia located momentary push-button provides lamp-test and buzzer silence functionality. Added LEDs provide power health and system fault indications.Outstations are wired to the refuge master panel in a loop configuration reducing installation time and costs. Any toilet alarm kit can be wired in-line with an accompanying disable refuge callanswer point.Space for 17Ah batteries is provided within the cabinet these will provide 24 3 hours standby as specified by BS5839 Part 9.The unit is available in surface or flush mount enclosure options comprising a mild steel back box with stainless steel fascia plate including a tamper resistant vision window cover.Key FeaturesDisable Refuge Combined Master Panel32x Callanswer outstation inputsSimple handset operationAlarm indicators and internal buzzerPower on and system fault indicatorsLamp test and silence buzzer push buttonLoop wired outstationsEnable In Fire input to prevent non-essential callsIntegrated display to show custom alarm informationTamper resistant vision window cover

GBP 5441.84
1

Kentec K41108SST Disabled Refuge 8 Line Central Unit with OLED Display

Kentec K41108SST Disabled Refuge 8 Line Central Unit with OLED Display

Kentec K41108SST Disabled Refuge8 Line Central Unit with OLED DisplayThe Disabled Refuge8 Line Central Unit can answer or call out to each multiple or all of the Safe-Point disabled refuge outstations by activating the corresponding fascia push-buttons. Once connected full duplex conversations can take place and calls are ended by simply replacing the integrated handset.Accompanying LED indicators and an internal buzzer notify of any disabled refuse alarms raised. A fascia located momentary push-button provides lamp-test and buzzer silence functionality. Added LEDs provide power health and system fault indications.The unit is available in two installation versions allowing wiring to disabled refuge outstations to be made either radially or over a loop. Any toilet alarm kit can be wired in line with an accompanying disable refuge callanswer point.Space for 7Ah batteries is provided within the cabinet these will provide 24 3 hours standby as specified by BS5839 Part 9.The unit is available in surface or flush mount enclosure options comprising a mild steel back box with stainless steel fascia plate including a tamper resistant vision window cover.Key FeaturesDisable Refuge Combined Master Panel8x Callanswer outstation inputsSimple handset operationAlarm indicators and internal buzzerPower on and system fault indicatorsLamp test and silence buzzer push buttonLoop or radial Outstation connection optionsEnable In Fire input to prevent non-essential callsIntegrated display to show custom alarm informationTamper resistant vision window cover

GBP 2404.33
1

Kentec K41216FST Disabled Refuge 16 Line Central Unit with OLED Display - Loop Wired Flush Mounting

Kentec K41216FST Disabled Refuge 16 Line Central Unit with OLED Display - Loop Wired Flush Mounting

Kentec K41216FST Disabled Refuge 16 Line Central Unit with OLED Display - Loop Wired Flush MountingThe Disabled Refuge 16 Line Central Unit can answer or call out to each multiple or all of the Safe-Point disabled refuge outstations by activating the corresponding fascia push-buttons. Once connected full duplex conversations can take place and calls are ended by simply replacing the integrated handset.Accompanying LED indicators and an internal buzzer notify of any disabled refuse alarms raised. A fascia located momentary push-button provides lamp-test and buzzer silence functionality. Added LEDs provide power health and system fault indications.Outstations are wired to the refuge master panel in a loop configuration reducing installation time and costs. Any toilet alarm kit can be wired in-line with an accompanying disable refuge callanswer point.Space for 7Ah batteries is provided within the cabinet these will provide 24 3 hours standby as specified by BS5839 Part 9.The unit is available in surface or flush mount enclosure options comprising a mild steel back box with stainless steel fascia plate including a tamper resistant vision window cover.Key Features16x Callanswer outstation inputsSimple handset operationAlarm indicators and internal buzzerPower on and system fault indicatorsLamp test and silence buzzer push buttonLoop wired outstationsEnable In Fire input to prevent non-essential callsIntegrated display to show custom alarm informationTamper resistant vision window cover

GBP 4072.82
1

Kentec K41232SST Disabled Refuge 32 Line Central Unit with OLED Display - Loop Wired Surface Mounting

Kentec K41232SST Disabled Refuge 32 Line Central Unit with OLED Display - Loop Wired Surface Mounting

Kentec K41232SST Disabled Refuge 32 Line Central Unit with OLED Display - Loop Wired Surface MountingThe Disabled Refuge 32 Line Central Unit can answer or call out to each multiple or all of the Safe-Point disabled refuge outstations by activating the corresponding fascia push-buttons. Once connected full duplex conversations can take place and calls are ended by simply replacing the integrated handset.Accompanying LED indicators and an internal buzzer notify of any disabled refuse alarms raised. A fascia located momentary push-button provides lamp-test and buzzer silence functionality. Added LEDs provide power health and system fault indications.Outstations are wired to the refuge master panel in a loop configuration reducing installation time and costs. Any toilet alarm kit can be wired in-line with an accompanying disable refuge callanswer point.Space for 17Ah batteries is provided within the cabinet these will provide 24 3 hours standby as specified by BS5839 Part 9.The unit is available in surface or flush mount enclosure options comprising a mild steel back box with stainless steel fascia plate including a tamper resistant vision window cover.Key FeaturesDisable Refuge Combined Master Panel32x Callanswer outstation inputsSimple handset operationAlarm indicators and internal buzzerPower on and system fault indicatorsLamp test and silence buzzer push buttonLoop wired outstationsEnable In Fire input to prevent non-essential callsIntegrated display to show custom alarm informationTamper resistant vision window cover

GBP 5784.11
1

Kentec K41216SST Disabled Refuge 16 Line Central Unit with OLED Display - Loop Wired Surface Mounting

Kentec K41216SST Disabled Refuge 16 Line Central Unit with OLED Display - Loop Wired Surface Mounting

Kentec K41216SST Disabled Refuge 16 Line Central Unit with OLED Display - Loop Wired Surface MountingThe Disabled Refuge 16 Line Central Unit can answer or call out to each multiple or all of the Safe-Point disabled refuge outstations by activating the corresponding fascia push-buttons. Once connected full duplex conversations can take place and calls are ended by simply replacing the integrated handset.Accompanying LED indicators and an internal buzzer notify of any disabled refuse alarms raised. A fascia located momentary push-button provides lamp-test and buzzer silence functionality. Added LEDs provide power health and system fault indications.Outstations are wired to the refuge master panel in a loop configuration reducing installation time and costs. Any toilet alarm kit can be wired in-line with an accompanying disable refuge callanswer point.Space for 7Ah batteries is provided within the cabinet these will provide 24 3 hours standby as specified by BS5839 Part 9.The unit is available in surface or flush mount enclosure options comprising a mild steel back box with stainless steel fascia plate including a tamper resistant vision window cover.Key Features16x Callanswer outstation inputsSimple handset operationAlarm indicators and internal buzzerPower on and system fault indicatorsLamp test and silence buzzer push buttonLoop wired outstationsEnable In Fire input to prevent non-essential callsIntegrated display to show custom alarm informationTamper resistant vision window cover

GBP 4415.09
1

Kentec K41208SST Disabled Refuge 8 Line Central Unit with OLED Display - Loop Wired Surface Mounting

Kentec K41208SST Disabled Refuge 8 Line Central Unit with OLED Display - Loop Wired Surface Mounting

Kentec K41208SST Disabled Refuge 8 Line Central Unit with OLED Display - Loop Wired Surface MountingThe Disabled Refuge 8 line Central Unit can answer or call out to each multiple or all of the Safe-Point disabled refuge outstations by activating the corresponding fascia push-buttons. Once connected full duplex conversations can take place and calls are ended by simply replacing the integrated handset.Accompanying LED indicators and an internal buzzer notify of any disabled refuse alarms raised. A fascia located momentary push-button provides lamp-test and buzzer silence functionality. Added LEDs provide power health and system fault indications.The unit is available in two installation versions allowing wiring to disabled refuge outstations to be made either radially or over a loop. Any toilet alarm kit can be wired in line with an accompanying disable refuge callanswer point.Space for 7Ah batteries is provided within the cabinet these will provide 24 3 hours standby as specified by BS5839 Part 9.The unit is available in surface or flush mount enclosure options comprising a mild steel back box with stainless steel fascia plate including a tamper resistant vision window cover.Key FeaturesDisable Refuge Combined Master Panel8x Callanswer outstation inputsSimple handset operationAlarm indicators and internal buzzerPower on and system fault indicatorsLamp test and silence buzzer push buttonLoop or radial Outstation connection optionsEnable In Fire input to prevent non-essential callsIntegrated display to show custom alarm informationTamper resistant vision window cover

GBP 2714.06
1

Kentec K1848-11 Sigma A-CP 8 Zone Control Panel 240V Red

Kentec K1848-11 Sigma A-CP 8 Zone Control Panel 240V Red

Kentec K1848-11 Sigma A-CP 8 Zone Control Panel 240V RedThe Sigma A-CP is a range of conventional fire control panelswith an optional built-in communicator. With two four or eight initiatingcircuits all panels can be extensively configured via a simple front paneloperated programming method. The low standby power requirements and costeffective small batteries allow the panel to be mounted in a discrete enclosurewhich is available in red or grey. A simple programming method using just 3front panel buttons allows an extensive list of configuration options to be setand reviewed. Single board construction enables easy removal of all electronicparts by removing just two screws and ample provision of cable entry knockoutssimplify installation. 4 Amp notification appliance power and built-inselectable sync protocols provide ample power and control for a wide range ofstandard notification appliances. The built-in RS485 communications busprovides the facility to connect 4 wire annunciators or ancillary relay boardsto provide further indication and control options throughout a premises. Theoptional DACT allows dual line reporting to central stations and provides a500-event history buffer.Key Features8 Zone CircuitsInitiating circuits individually configurable as Fire Water Flow or SupervisoryTwo 2A notification appliance circuitsSelectable NAC sync protocols6.5A power supplyAlarm verification selectable by zoneResettable aux power output rated at 0.3AAux power configurable to power off on Fire conditionFire trouble and supervisory relaysSingle person walk test functionOptional DACTAdvanced configuration options72 hour standby with 7Ah batteriesCompact enclosureUL864 listed

GBP 466.76
1

Kentec MM-56-00-00-6PM3 Addressable Matrix Panel - Max 56 LEDs cw PSU

Kentec MM-56-00-00-6PM3 Addressable Matrix Panel - Max 56 LEDs cw PSU

Kentec MM-56-00-00-6PM3 Addressable Matrix Panel - Max 56 LEDs comes with PSU No ControlsThe Addressable Matrix system uses flexible fibre optic light guides to illuminate areas on a floor plan laid over a high-resolution grid. This unique system dispenses completely with wiring and enables indicators to be moved removed or added on site without the need for any wiring.Ideal for buildings such as hospitals where the building layout may evolve over a period. As the building changes so too can the addressable Matrix with very little cost or disruption.The Addressable Matrix can be supplied with or without common LEDs and controls. Optional LEDs indicate Power on Fire Fault and Disablement and optional controls are for Alarm silence Buzzer silence Lamp test and Reset.It provides a clear geographical indication of fire alarm or other system activation enabling speedy identification of the source of an alarm or other events.Up to 32 mimic PCBs can be connected to a single Syncro AS or Taktis Fire panel giving a total of 504 LEDs that can be individually configured via the standard loop explorer configuration software. To increase the flexibility of this product further the LED extension boards are available in with yellow or green indicators fitted.Key FeaturesFlexible fibre optic light guides to illuminate areas on a floor planHigh-resolution gridCompatible with Taktis and Syncro AS panelsUp to 24 LED indications no controlsM3 Surface mount enclosure 385mm W x 520mm H x 90mm DInternal PSU 230V AC input

GBP 1702.88
1

Kentec MM-56-00-00-6PS3 Addressable Matrix Panel - Max 56 LEDs cw PSU

Kentec MM-56-00-00-6PS3 Addressable Matrix Panel - Max 56 LEDs cw PSU

Kentec MM-56-00-00-6PS3 Addressable Matrix Panel - Max 56 LEDs comes with PSU No ControlsThe Addressable Matrix system uses flexible fibre optic light guides to illuminate areas on a floor plan laid over a high-resolution grid. This unique system dispenses completely with wiring and enables indicators to be moved removed or added on site without the need for any wiring.Ideal for buildings such as hospitals where the building layout may evolve over a period. As the building changes so too can the addressable Matrix with very little cost or disruption.The Addressable Matrix can be supplied with or without common LEDs and controls. Optional LEDs indicate Power on Fire Fault and Disablement and optional controls are for Alarm silence Buzzer silence Lamp test and Reset.It provides a clear geographical indication of fire alarm or other system activation enabling speedy identification of the source of an alarm or other events.Up to 32 mimic PCBs can be connected to a single Syncro AS or Taktis Fire panel giving a total of 504 LEDs that can be individually configured via the standard loop explorer configuration software. To increase the flexibility of this product further the LED extension boards are available in with yellow or green indicators fitted.Key FeaturesFlexible fibre optic light guides to illuminate areas on a floor planHigh-resolution gridCompatible with Taktis and Syncro AS panelsUp to 24 LED indications no controlsS3 Surface mount enclosure 500mm W x 355mm H x 120mm DInternal PSU 230V AC input

GBP 1702.88
1

Kentec K1848-41 Sigma A-CP 8 Zone Control Panel 240V Grey

Kentec K1848-41 Sigma A-CP 8 Zone Control Panel 240V Grey

Kentec K1848-41 Sigma A-CP 8 Zone Control Panel 240V GreyThe Sigma A-CP is a range of conventional fire control panelswith an optional built-in communicator. With two four or eight initiatingcircuits all panels can be extensively configured via a simple front paneloperated programming method. The low standby power requirements and costeffective small batteries allow the panel to be mounted in a discrete enclosurewhich is available in red or grey. A simple programming method using just 3front panel buttons allows an extensive list of configuration options to be setand reviewed. Single board construction enables easy removal of all electronicparts by removing just two screws and ample provision of cable entry knockoutssimplify installation. 4 Amp notification appliance power and built-inselectable sync protocols provide ample power and control for a wide range ofstandard notification appliances. The built-in RS485 communications busprovides the facility to connect 4 wire annunciators or ancillary relay boardsto provide further indication and control options throughout a premises. Theoptional DACT allows dual line reporting to central stations and provides a500-event history buffer.Key Features8 Zone CircuitsInitiating circuits individually configurable as Fire Water Flow or SupervisoryTwo 2A notification appliance circuitsSelectable NAC sync protocols6.5A power supplyAlarm verification selectable by zoneResettable aux power output rated at 0.3AAux power configurable to power off on Fire conditionFire trouble and supervisory relaysSingle person walk test functionOptional DACTAdvanced configuration options72 hour standby with 7Ah batteriesCompact enclosureUL864 listed

GBP 466.76
1

Kentec K1848-10 Sigma A-CP 8 Zone Control Panel 115V Red

Kentec K1848-10 Sigma A-CP 8 Zone Control Panel 115V Red

Kentec K1848-10 Sigma A-CP 8 Zone Control Panel 115V RedThe Sigma A-CP is a range of conventional fire control panelswith an optional built-in communicator. With two four or eight initiatingcircuits all panels can be extensively configured via a simple front paneloperated programming method. The low standby power requirements and costeffective small batteries allow the panel to be mounted in a discrete enclosurewhich is available in red or grey. A simple programming method using just 3front panel buttons allows an extensive list of configuration options to be setand reviewed. Single board construction enables easy removal of all electronicparts by removing just two screws and ample provision of cable entry knockoutssimplify installation. 4 Amp notification appliance power and built-inselectable sync protocols provide ample power and control for a wide range ofstandard notification appliances. The built-in RS485 communications busprovides the facility to connect 4 wire annunciators or ancillary relay boardsto provide further indication and control options throughout a premises. Theoptional DACT allows dual line reporting to central stations and provides a500-event history buffer.Key Features8 Zone CircuitsInitiating circuits individually configurable as Fire Water Flow or SupervisoryTwo 2A notification appliance circuitsSelectable NAC sync protocols6.5A power supplyAlarm verification selectable by zoneResettable aux power output rated at 0.3AAux power configurable to power off on Fire conditionFire trouble and supervisory relaysSingle person walk test functionOptional DACTAdvanced configuration options72 hour standby with 7Ah batteriesCompact enclosureUL864 listed

GBP 466.76
1

Kentec K1848-40 Sigma A-CP 8 Zone Control Panel 115V Grey

Kentec K1848-40 Sigma A-CP 8 Zone Control Panel 115V Grey

Kentec K1848-40 Sigma A-CP 8 Zone Control Panel 115V GreyThe Sigma A-CP is a range of conventional fire control panelswith an optional built-in communicator. With two four or eight initiatingcircuits all panels can be extensively configured via a simple front paneloperated programming method. The low standby power requirements and costeffective small batteries allow the panel to be mounted in a discrete enclosurewhich is available in red or grey. A simple programming method using just 3front panel buttons allows an extensive list of configuration options to be setand reviewed. Single board construction enables easy removal of all electronicparts by removing just two screws and ample provision of cable entry knockoutssimplify installation. 4 Amp notification appliance power and built-inselectable sync protocols provide ample power and control for a wide range ofstandard notification appliances. The built-in RS485 communications busprovides the facility to connect 4 wire annunciators or ancillary relay boardsto provide further indication and control options throughout a premises. Theoptional DACT allows dual line reporting to central stations and provides a500-event history buffer.Key Features8 Zone CircuitsInitiating circuits individually configurable as Fire Water Flow or SupervisoryTwo 2A notification appliance circuitsSelectable NAC sync protocols6.5A power supplyAlarm verification selectable by zoneResettable aux power output rated at 0.3AAux power configurable to power off on Fire conditionFire trouble and supervisory relaysSingle person walk test functionOptional DACTAdvanced configuration options72 hour standby with 7Ah batteriesCompact enclosureUL864 listed

GBP 466.76
1

Kentec MM-152-00-00-6PS4 Addressable Matrix panel - Max 152 LEDs cw PSU

Kentec MM-152-00-00-6PS4 Addressable Matrix panel - Max 152 LEDs cw PSU

Kentec MM-152-00-00-6PS4 Addressable Matrix Panel - Max 152 LEDs comes with PSU No ControlsThe Addressable Matrix system uses flexible fibre optic light guides to illuminate areas on a floor plan laid over a high-resolution grid. This unique system dispenses completely with wiring and enables indicators to be moved removed or added on site without the need for any wiring.Ideal for buildings such as hospitals where the building layout may evolve over a period. As the building changes so too can the addressable Matrix with very little cost or disruption.The Addressable Matrix can be supplied with or without common LEDs and controls. Optional LEDs indicate Power on Fire Fault and Disablement and optional controls are for Alarm silence Buzzer silence Lamp test and Reset.It provides a clear geographical indication of fire alarm or other system activation enabling speedy identification of the source of an alarm or other events.Up to 32 mimic PCBs can be connected to a single Syncro AS or Taktis Fire panel giving a total of 504 LEDs that can be individually configured via the standard loop explorer configuration software. To increase the flexibility of this product further the LED extension boards are available in with yellow or green indicators fitted.Key FeaturesFlexible fibre optic light guides to illuminate areas on a floor planHigh-resolution gridCompatible with Taktis and Syncro AS panelsUp to 24 LED indications no controlsS4 Surface mount enclosure 500mm W x 650mm H x 140mm DInternal PSU 230V AC input

GBP 3464.50
1

Kentec MM-56-00-00-6PS4 Addressable Matrix Panel - Max 56 LEDs cw PSU

Kentec MM-56-00-00-6PS4 Addressable Matrix Panel - Max 56 LEDs cw PSU

Kentec MM-56-00-00-6PS4 Addressable Matrix Panel - Max 56 LEDs comes with PSU No ControlsThe Addressable Matrix system uses flexible fibre optic light guides to illuminate areas on a floor plan laid over a high-resolution grid. This unique system dispenses completely with wiring and enables indicators to be moved removed or added on site without the need for any wiring.Ideal for buildings such as hospitals where the building layout may evolve over a period. As the building changes so too can the addressable Matrix with very little cost or disruption.The Addressable Matrix can be supplied with or without common LEDs and controls. Optional LEDs indicate Power on Fire Fault and Disablement and optional controls are for Alarm silence Buzzer silence Lamp test and Reset.It provides a clear geographical indication of fire alarm or other system activation enabling speedy identification of the source of an alarm or other events.Up to 32 mimic PCBs can be connected to a single Syncro AS or Taktis Fire panel giving a total of 504 LEDs that can be individually configured via the standard loop explorer configuration software. To increase the flexibility of this product further the LED extension boards are available in with yellow or green indicators fitted.Key FeaturesFlexible fibre optic light guides to illuminate areas on a floor planHigh-resolution gridCompatible with Taktis and Syncro AS panelsUp to 24 LED indications no controlsS4 Surface mount enclosure 500mm W x 650mm H x 140mm DInternal PSU 230V AC input

GBP 1937.76
1

Kentec MM-104-00-00-6PS4 Addressable Matrix Panel - Max 104 LEDs cw PSU

Kentec MM-104-00-00-6PS4 Addressable Matrix Panel - Max 104 LEDs cw PSU

Kentec MM-104-00-00-6PS4 Addressable Matrix Panel - Max 104 LEDs comes with PSU No ControlsThe Addressable Matrix system uses flexible fibre optic light guides to illuminate areas on a floor plan laid over a high-resolution grid. This unique system dispenses completely with wiring and enables indicators to be moved removed or added on site without the need for any wiring.Ideal for buildings such as hospitals where the building layout may evolve over a period. As the building changes so too can the addressable Matrix with very little cost or disruption.The Addressable Matrix can be supplied with or without common LEDs and controls. Optional LEDs indicate Power on Fire Fault and Disablement and optional controls are for Alarm silence Buzzer silence Lamp test and Reset.It provides a clear geographical indication of fire alarm or other system activation enabling speedy identification of the source of an alarm or other events.Up to 32 mimic PCBs can be connected to a single Syncro AS or Taktis Fire panel giving a total of 504 LEDs that can be individually configured via the standard loop explorer configuration software. To increase the flexibility of this product further the LED extension boards are available in with yellow or green indicators fitted.Key FeaturesFlexible fibre optic light guides to illuminate areas on a floor planHigh-resolution gridCompatible with Taktis and Syncro AS panelsUp to 24 LED indications no controlsS4 Surface mount enclosure 500mm W x 650mm H x 140mm DInternal PSU 230V AC input

GBP 2642.40
1

Kentec K85000 Vizulinx Gateway Unit

Kentec K85000 Vizulinx Gateway Unit

Kentec K85000 Vizulinx Gateway UnitVizulinx is a fire alarm management solution which enables you to monitor your fire systems remotely. Highly configurable using an embedded web server and simple configuration wizard it can be used to pass fire system events via e-mail SMS Modbus and message format using an IP connection. Event notifications are triggered and processed immediately.Email or mobile phone messages can be routed to any number of recipients based on the fire alarm event types. These include fire pre-alarm fault disable in test technical alarm and security. As events are sent immediately this reduces false alarms as it allows alarms to be investigated before sounding to prevent unnecessary evacuation. Modbus connectivity enables a simple low-cost integration into building management systems.Through Mass Notification Vizulinx keeps the occupants and key emergency responders aware of alarm conditions with location description or area messages and required event actions. Connection to the fire panel can be either RS232 serial data from the Syncro family of panels or up to 16 switched GPIO inputs from other fire panels including Taktis. Provides building managers service organizations instant updates on any faults fire alarm activity thus providing convenience and time-saving efficiencies.Key FeaturesMonitor fire alarm activity on your workstation or deviceReceive alerts by email SMS or pagerEasy user subscription function - opt in opt out via textDefined message notification for managers engineers or building occupiersCompatible with Modbus protocolsConfiguration through embedded web serverQuick setup user friendly operationInternal memory event logIsolated RS232 portA convenient and cost-effective solutionHoused or module only optionsDIN rail mountable module only

GBP 1488.82
1

Kentec K85000M2 Vizulinx Gateway M2 Boxed Unit 110v AC

Kentec K85000M2 Vizulinx Gateway M2 Boxed Unit 110v AC

Kentec K85000M2 Vizulinx Gateway M2 Boxed Unit 110v ACVizulinx is a fire alarm management solution which enables you to monitor your fire systems remotely. Highly configurable using an embedded web server and simple configuration wizard it can be used to pass fire system events via e-mail SMS Modbus and message format using an IP connection. Event notifications are triggered and processed immediately.Email or mobile phone messages can be routed to any number of recipients based on the fire alarm event types. These include fire pre-alarm fault disable in test technical alarm and security. As events are sent immediately this reduces false alarms as it allows alarms to be investigated before sounding to prevent unnecessary evacuation. Modbus connectivity enables a simple low-cost integration into building management systems.Through Mass Notification Vizulinx keeps the occupants and key emergency responders aware of alarm conditions with location description or area messages and required event actions. Connection to the fire panel can be either RS232 serial data from the Syncro family of panels or up to 16 switched GPIO inputs from other fire panels including Taktis. Provides building managers service organizations instant updates on any faults fire alarm activity thus providing convenience and time-saving efficiencies.Key FeaturesMonitor fire alarm activity on your workstation or deviceReceive alerts by email SMS or pagerEasy user subscription function - opt in opt out via textDefined message notification for managers engineers or building occupiersCompatible with Modbus protocolsConfiguration through embedded web serverQuick setup user friendly operationInternal memory event logIsolated RS232 portA convenient and cost-effective solutionHoused or module only optionsDIN rail mountable module only

GBP 1665.64
1