56 results (0,13983 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Kidde DP721RT Dx700 Series Conventional Multisensor Fire Detector With Relay

Kidde DP721RT Dx700 Series Conventional Multisensor Fire Detector With Relay

Kidde DP721RT Dx700 Series Conventional Multisensor Fire Detector With RelayAll Aritech 700 series smoke detectors continuously monitor their sensitivity and operational status. Background drift is daily compensated to maintain the original calibrated sensitivity within the required limits.Once a day the detector performs a full diagnostic test that includes dynamically testing the sensing chamber and internal electronics. If a detector drifts out of sensitivity range or fails the internal diagnostics test this is reported back to the panel and indicated on the detector with a yellow fault LED.Maintenance friendly sensitivity level test modeThe 700 Series photoelectric detectors include a sensitivity test mode that may be activated by simply holding a magnet near the detectors test point. This initiates a self-diagnostic routine and provides visual indication if service is required. This test mode allows field sensitivity testing without the requirement for external meters or test gas.Field cleaning and serviceThe photoelectric sensing chamber unclips from the detector for easy field cleaning and service. During regular maintenance the detector cover can be removed the optical chamber removed and replaced by a low cost new chamber. On power up the detector auto-calibrates and returns to normal operating mode without any further intervention.The right detector for the right jobFor a truly fast and broad-spectrum detection the DP721RTA offers both optical and heat sensors. The interaction of both the smoke and heat algorithms ensure a quick response to both flaming and smouldering fires.All bases are provided with an integral locking tab for extra security if required. Bases are equipped with a shorting bar between IN and OUT that opens when the head is installed and that may be manually restored when removing the head. This simplifies cable continuity testing.Key FeaturesAutomatic self diagnostics with dynamic full detector and sensitivity testHigh false alarm immunity with floating background with drift compensationSeparate fire and fault LEDs for unambiguous alarm reportingWide operating voltage for use on most conventional systemsPolarity insensitive for carefree installationCOMNONC contacts for easy supervision on any systemManual self diagnostic with visual sensitivity indicationField exchangeable and disposable optical chamber

GBP 46.97
1

Kidde Airsense Stratos Capillary Sample Point Kit Flush

Kidde Airsense Stratos Capillary Sample Point Kit Conical

Kidde Airsense Stratos-HSSD 2 - Minimum Display Version 9-30710

Kidde Airsense Command Module Without Stratos-HSSD 2

Kidde Airsense Stratos-HSSD 2 Standard Detector 9-30621

Kidde Airsense Stratos-HSSD 2 Detector Fitted With Command Module 9-30620

Kidde AirSense Stratos HSSD 2 Detector in Steel Enclosure 9-30706

Kidde AirSense Stratos HSSD 2 Detector in Steel Enclosure 9-30706

Kidde AirSense Stratos HSSD 2 Detector in Steel Enclosure 9-30706Stratos HSSD2 is designed to provide very high sensitivity smoke detection ensuring the very earliest warning of incipient fire with minimum rate of nuisance alarms. ClassiFire Perceptive Artificial Intelligence ensures that the detector operates at optimum sensitivity for the protected environment without the need for complex setup.This means the product will configure itself to provide high sensitivity in a computer room or reduced sensitivity in a smoky area. Upgradable volt-free Fire and Fault relay outputs are available for remote monitoring by local fire detection or BMS systems. Command module available for central monitoring and display.Typical ApplicationsData storage unitsPrison cellsPlant roomsAir conditioning unitsEquipment racksComputer roomsAir duct protectionHeritage property protectionCritical equipmentAnti-smoking enforcementMotor roomsKey FeaturesHigh sensitivity provided by laser based forward light scatter for reliable early warningCombined sampling pipe up to 200m in length still airUnique ClassiFire Perceptive Artificial Intelligence system that dynamically adjusts the detectors operating parameters allowing for day to day changes in the protected environment and dust separation system contaminationUnwanted alarms from dust are avoided using patented Dual Technology LDD 3D3 Laser Dust Discrimination and elimination systemRS485 communications built in as standard for networking and remote communicationsLarge area aspirating smoke detector up to 2000m2 coverageCPR LPCB VdS NF CSIRO UL FM approved

GBP 2231.89
1

Kidde AirSense Stratos HSSD 2 Detector with Command Module in Steel Enclosure 9-30707

Kidde AirSense Stratos HSSD 2 Detector with Command Module in Steel Enclosure 9-30707

Kidde AirSense Stratos HSSD 2 Detector with Command Module in Steel Enclosure 9-30707Stratos HSSD2 is designed to provide very high sensitivity smoke detection ensuring the very earliest warning of incipient fire with minimum rate of nuisance alarms. ClassiFire Perceptive Artificial Intelligence ensures that the detector operates at optimum sensitivity for the protected environment without the need for complex setup.This means the product will configure itself to provide high sensitivity in a computer room or reduced sensitivity in a smoky area. Upgradable volt-free Fire and Fault relay outputs are available for remote monitoring by local fire detection or BMS systems. Command module available for central monitoring and display.Typical ApplicationsData storage unitsPrison cellsPlant roomsAir conditioning unitsEquipment racksComputer roomsAir duct protectionHeritage property protectionCritical equipmentAnti-smoking enforcementMotor roomsKey FeaturesHigh sensitivity provided by laser based forward light scatter for reliable early warningCombined sampling pipe up to 200m in length still airUnique ClassiFire Perceptive Artificial Intelligence system that dynamically adjusts the detectors operating parameters allowing for day to day changes in the protected environment and dust separation system contaminationUnwanted alarms from dust are avoided using patented Dual Technology LDD 3D3 Laser Dust Discrimination and elimination systemRS485 communications built in as standard for networking and remote communicationsLarge area aspirating smoke detector up to 2000m2 coverageCPR LPCB VdS NF CSIRO UL FM approved

GBP 3320.40
1

Kidde Airsense Micra 10 Single Pipe Aspiration Smoke Detector 9-30725

Kidde Airsense Micra 10 Single Pipe Aspiration Smoke Detector 9-30725

Kidde Airsense Micra 10 Single Pipe Aspiration Smoke Detector 9-30725The AirSense Micra 10 is designed to provide very high sensitivity smoke detection in a small package. ClassiFire Perceptive Artificial Intelligence ensures that the detector operates at optimum sensitivity for the protected environment without the need for complex setup. This means the product will configure itself to provide high sensitivity in a computer room or reduced sensitivity in a smoky area.The detector is designed to fit into a Docking Station. All sampling pipes and cables are connected to the Docking Station as a first fix operation leaving the detector to be fitted during the final commissioning phase if required. This ensures that detectors are less likely to be damaged during the installation. Upgradable volt-free Fire and Fault relay outputs are available for remote monitoring by local fire detection or BMS systems.ApplicationsData storage unitsPrison cellsPlant roomsAir conditioning unitsEquipment racksComputer roomsAir duct protectionHeritage property protectionCritical equipmentAnti-smoking enforcementMotor roomsKey FeaturesUltra-small low-cost aspirating smoke detector for easy and discreet installationHigh sensitivity provided by laser based forward light scatter for reliable early warningSingle sampling pipe up to 50m in length still airUnique ClassiFire Perceptive Artificial Intelligence system that dynamically adjusts the detectors operating parameters allowing for day to day changes in the protected environment and dust separation system contaminationUnwanted alarms from dust are avoided using patented Dual Technology LDD 3D3 Laser Dust Discrimination and elimination system

GBP 888.07
1

Kidde Airsense Wire Burn Test Rig 9-30051

Kidde KE-DM3010R-KIT 3000 Series Intelligent Addressable Manual Call Point - Surface Mount - Red

Kidde KE-DM3010R-KIT 3000 Series Intelligent Addressable Manual Call Point - Surface Mount - Red

Kidde KE-DM3010R-KIT 3000 Series Intelligent Addressable Manual Call Point - Surface Mount - RedThe KE-DM3000 Series is an intelligent range of addressable Excellence Series manual call points.The KE-DM3010R-KIT is a red single action indoor MCP with a House-on-Fire functional indicator. It is delivered complete with back box resettable element test connector and test key. Multiple optional accessories are available to facilitate most indoor installation requirements.AestheticsThis single action MCP is a standard profile indoor MCP suitable for surface and recess mount installations using standard or legacy European electrical boxes. With its designer dual tricolour LEDs it offers 180 clear local indication of its operational status even from a side view in a passage installation. The clean face of the MCP is further enhanced by a front access test key facility.CompatibilityThe KE-DM3000 range may be used on all Kidde Excellence Series fire systems and are also compatible with legacy Aritech fire systems. They can in many cases be deployed into existing systems without CIE configuration changes.Key FeaturesReliable single action manual call point for recess or surface mountingDual tri-colour status indicators offers 180 alarm visibilityTamper resistant design with resettable or frangible elementUnobtrusive front facing test facilityStandard mounting options facilitates easy retrofitting to existing installationsBack box with rear top and bottom cable entryScreen connection terminal in the back box for electrically noisy installationsPluggable connector with link through facility for ease of installation and pre-commissioning testingAn alarm flag on the face of the manual call point allows alarm indication even without alarm LEDsFast no-tools-required maintenance using the test keyUp to 128 devices supported per loop

GBP 43.28
1

Kidde Airsense 9-30797 Modulaser Accessory Pack

NC-DBO Conventional Beam Detector - Reflective

NC-DBO Conventional Beam Detector - Reflective

NC-DBO Conventional Beam Detector - ReflectiveThe NC-DBO is a reflective infrared beam smoke detector for use in conventional fire detection systems. Being microprocessor based the detector offers extensive algorithms for analysis and decision making. Taking ambient operating conditions into consideration system adjustments such as drift compensation and alarm and fault analysis are automatic. The sensitivity of the detector is adjustable to suit various application conditions.InstallationThe number of reflectors in a system varies depending on the required operating distance detection range of the detector. Optical reflectors from 1 to 4 provide an effective range of the detector between 5 and 100m. Four reflectors are supplied with the beam. The detection range of the beam can be selected from 4 levels with the hand held programmer NC-D-PT. For very short range detection 10 m a non reflective mask NRM9105 is recommended to attenuate the reflector.Key FeaturesWide operating voltage rangeLarge protection areaCombination of transmitter receiver in one housingallows for easy installation and optical alignmentIntelligent microprocessor based decision making on fire andfault statusesEasy alignment and commissioning with onboard laser andsignal level indicationSelf-diagnostics for monitoring reporting internalfailuresAutomatic drift compensation compensates for changingenvironmental conditions dust and dirt accumulation building movement andchanging internal component specifications due to ageingOnboard NO fire and NC fault dry contact outputs for easysupervisionFour selectable sensitivity levels for wideapplication coverage

GBP 426.44
1

NC-DPO-W Conventional Point Detector - Optical White

Kidde Airsense Relay Input Card 9-30436

NC-DPM-W Conventional Point Detector - OpticalHeat White

NC-DPM-B Conventional Point Detector - OpticalHeat Black

Kiddie NC-MC-IP-100-R Intelligent conventional weatherproof manual call point 100 red

Kidde NC-PF2 Conventional Fire Panel With UI - 2 Zone

Kidde NC-PF2 Conventional Fire Panel With UI - 2 Zone

The New Conventional fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mid-sized conventional applications. With their clean and attractive contemporary design they fits with any dcor. The basic and intuitive user interface with icons make easy their application everywhere without an additional language kit required.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.The panelThe NC-PF2 is a conventional fire alarm control panel. It is supplied with 2 zones that support up to 32 devices per zone as well as up to 2 supervised relay outputs dedicated to sounder control. In addition 2 conventional relay outputs dedicated to common fire and fault conditions as well as two user configurable inputs for monitoring and control are available.No Language Kit required for localization.OptionsThe panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 8 additional outputs.Approvals ComplianceThe product line carries the following accreditationsEN542 EN544 and CE approvedCPD certifiedWEEE compliantRoHS compliantType class conditions 3K5 of IEC 60721-3-3Key FeaturesModern elegant design with basic and intuitive user interface with icons.Easy removable parts for quick and clean installationDefault regional setup modesNormal head-out intrinsically safe zone supportSupervised alarm notification outputsEN54 compliant potential free fire fault relaysClass change daynight remote reset facilitiesAuxiliary 24 VDC supply output with reset supportDefault support for special functions such as - EN54 compliant user access levels - mixed zones - full front panel diagnostics - one-man walk test - CleanMeAuxiliary standard supervised relay output boardsNetworkable up to 64 zonesNo language kit inserts required

GBP 226.60
1