Kidde Airsense 34quot Large Check Valve 9-10978

Kidde Airsense 34quot Large Check Valve 9-10978

Kidde Airsense 34 Large Check Valve 9-10978When the aspirating smoke detection system is installed in a dirty or dusty environment the sampling pipes and sampling holes can get obscured over a period of time by the various airborne particles. As a result it is recommend to clean the sampling pipes and holes by blowing low pressure compressed air in the reverse direction through the sampling pipes. The connection of the compressed air to the sampling pipe and the release of excess air at the end of the sampling pipe can be cumbersome.With the Quick Release Airline Valve 9-30976 the Large Check Valve 9-10978 and Large 2 Way Ball Valve 9-10980 this does not need to be the case anymore. The quick release airline valve is installed close to the detector. During maintenance the detector can be switched-off and the valve closed to prevent any damage to the detector during the clearing process.The low pressure compressed air can now be easily connected to the quick release. At the far end of the sampling pipe the large check valve or large 2 way ball valve can be used. The check value is the easiest to use as it will automatically open to release excess pressure during the cleaning process and does not require any human interaction. In some cases the check valve might not be suitable and then the 2 way ball valve can be used to manually open the far end of the sampling pipe.Key FeaturesEasy maintenanceRobust valve which automatically release excess pressureFor use with 9-10976 - quick release airline valve

GBP 57.94
1

Kidde Airsense Command Module Without Stratos-HSSD 2

Kidde Airsense Stratos-HSSD 2 - Minimum Display Version 9-30710

Kidde Airsense Stratos-HSSD 2 Standard Detector 9-30621

Kidde Airsense Stratos-HSSD 2 Detector Fitted With Command Module 9-30620

Kidde DP721RT Dx700 Series Conventional Multisensor Fire Detector With Relay

Kidde DP721RT Dx700 Series Conventional Multisensor Fire Detector With Relay

Kidde DP721RT Dx700 Series Conventional Multisensor Fire Detector With RelayAll Aritech 700 series smoke detectors continuously monitor their sensitivity and operational status. Background drift is daily compensated to maintain the original calibrated sensitivity within the required limits.Once a day the detector performs a full diagnostic test that includes dynamically testing the sensing chamber and internal electronics. If a detector drifts out of sensitivity range or fails the internal diagnostics test this is reported back to the panel and indicated on the detector with a yellow fault LED.Maintenance friendly sensitivity level test modeThe 700 Series photoelectric detectors include a sensitivity test mode that may be activated by simply holding a magnet near the detectors test point. This initiates a self-diagnostic routine and provides visual indication if service is required. This test mode allows field sensitivity testing without the requirement for external meters or test gas.Field cleaning and serviceThe photoelectric sensing chamber unclips from the detector for easy field cleaning and service. During regular maintenance the detector cover can be removed the optical chamber removed and replaced by a low cost new chamber. On power up the detector auto-calibrates and returns to normal operating mode without any further intervention.The right detector for the right jobFor a truly fast and broad-spectrum detection the DP721RTA offers both optical and heat sensors. The interaction of both the smoke and heat algorithms ensure a quick response to both flaming and smouldering fires.All bases are provided with an integral locking tab for extra security if required. Bases are equipped with a shorting bar between IN and OUT that opens when the head is installed and that may be manually restored when removing the head. This simplifies cable continuity testing.Key FeaturesAutomatic self diagnostics with dynamic full detector and sensitivity testHigh false alarm immunity with floating background with drift compensationSeparate fire and fault LEDs for unambiguous alarm reportingWide operating voltage for use on most conventional systemsPolarity insensitive for carefree installationCOMNONC contacts for easy supervision on any systemManual self diagnostic with visual sensitivity indicationField exchangeable and disposable optical chamber

GBP 46.97
1

Kidde AirSense Stratos HSSD 2 Detector in Steel Enclosure 9-30706

Kidde AirSense Stratos HSSD 2 Detector in Steel Enclosure 9-30706

Kidde AirSense Stratos HSSD 2 Detector in Steel Enclosure 9-30706Stratos HSSD2 is designed to provide very high sensitivity smoke detection ensuring the very earliest warning of incipient fire with minimum rate of nuisance alarms. ClassiFire Perceptive Artificial Intelligence ensures that the detector operates at optimum sensitivity for the protected environment without the need for complex setup.This means the product will configure itself to provide high sensitivity in a computer room or reduced sensitivity in a smoky area. Upgradable volt-free Fire and Fault relay outputs are available for remote monitoring by local fire detection or BMS systems. Command module available for central monitoring and display.Typical ApplicationsData storage unitsPrison cellsPlant roomsAir conditioning unitsEquipment racksComputer roomsAir duct protectionHeritage property protectionCritical equipmentAnti-smoking enforcementMotor roomsKey FeaturesHigh sensitivity provided by laser based forward light scatter for reliable early warningCombined sampling pipe up to 200m in length still airUnique ClassiFire Perceptive Artificial Intelligence system that dynamically adjusts the detectors operating parameters allowing for day to day changes in the protected environment and dust separation system contaminationUnwanted alarms from dust are avoided using patented Dual Technology LDD 3D3 Laser Dust Discrimination and elimination systemRS485 communications built in as standard for networking and remote communicationsLarge area aspirating smoke detector up to 2000m2 coverageCPR LPCB VdS NF CSIRO UL FM approved

GBP 2231.89
1

Kidde AirSense Stratos HSSD 2 Detector with Command Module in Steel Enclosure 9-30707

Kidde AirSense Stratos HSSD 2 Detector with Command Module in Steel Enclosure 9-30707

Kidde AirSense Stratos HSSD 2 Detector with Command Module in Steel Enclosure 9-30707Stratos HSSD2 is designed to provide very high sensitivity smoke detection ensuring the very earliest warning of incipient fire with minimum rate of nuisance alarms. ClassiFire Perceptive Artificial Intelligence ensures that the detector operates at optimum sensitivity for the protected environment without the need for complex setup.This means the product will configure itself to provide high sensitivity in a computer room or reduced sensitivity in a smoky area. Upgradable volt-free Fire and Fault relay outputs are available for remote monitoring by local fire detection or BMS systems. Command module available for central monitoring and display.Typical ApplicationsData storage unitsPrison cellsPlant roomsAir conditioning unitsEquipment racksComputer roomsAir duct protectionHeritage property protectionCritical equipmentAnti-smoking enforcementMotor roomsKey FeaturesHigh sensitivity provided by laser based forward light scatter for reliable early warningCombined sampling pipe up to 200m in length still airUnique ClassiFire Perceptive Artificial Intelligence system that dynamically adjusts the detectors operating parameters allowing for day to day changes in the protected environment and dust separation system contaminationUnwanted alarms from dust are avoided using patented Dual Technology LDD 3D3 Laser Dust Discrimination and elimination systemRS485 communications built in as standard for networking and remote communicationsLarge area aspirating smoke detector up to 2000m2 coverageCPR LPCB VdS NF CSIRO UL FM approved

GBP 3320.40
1

Kidde Airsense Micra 10 Single Pipe Aspiration Smoke Detector 9-30725

Kidde Airsense Micra 10 Single Pipe Aspiration Smoke Detector 9-30725

Kidde Airsense Micra 10 Single Pipe Aspiration Smoke Detector 9-30725The AirSense Micra 10 is designed to provide very high sensitivity smoke detection in a small package. ClassiFire Perceptive Artificial Intelligence ensures that the detector operates at optimum sensitivity for the protected environment without the need for complex setup. This means the product will configure itself to provide high sensitivity in a computer room or reduced sensitivity in a smoky area.The detector is designed to fit into a Docking Station. All sampling pipes and cables are connected to the Docking Station as a first fix operation leaving the detector to be fitted during the final commissioning phase if required. This ensures that detectors are less likely to be damaged during the installation. Upgradable volt-free Fire and Fault relay outputs are available for remote monitoring by local fire detection or BMS systems.ApplicationsData storage unitsPrison cellsPlant roomsAir conditioning unitsEquipment racksComputer roomsAir duct protectionHeritage property protectionCritical equipmentAnti-smoking enforcementMotor roomsKey FeaturesUltra-small low-cost aspirating smoke detector for easy and discreet installationHigh sensitivity provided by laser based forward light scatter for reliable early warningSingle sampling pipe up to 50m in length still airUnique ClassiFire Perceptive Artificial Intelligence system that dynamically adjusts the detectors operating parameters allowing for day to day changes in the protected environment and dust separation system contaminationUnwanted alarms from dust are avoided using patented Dual Technology LDD 3D3 Laser Dust Discrimination and elimination system

GBP 888.07
1

Kidde Airsense Wire Burn Test Rig 9-30051

Kidde Airsense Air Heat Box 9-30422

Kidde Airsense Quick Release Airline Valve 9-10976

Kidde Airsense Quick Release Airline Valve 9-10976

Kidde Airsense Quick Release Airline Valve 9-10976When the aspirating smoke detection system is installed in a dirty or dusty environment the sampling pipes and sampling holes can get obscured over a period of time by the various airborne particles. As a result it is recommend to clean the sampling pipes and holes by blowing low pressure compressed air in the reverse direction through the sampling pipes. The connection of the compressed air to the sampling pipe and the release of excess air at the end of the sampling pipe can be cumbersome.With introduction of the Quick Release Airline Valve 9-30976 the Large Check Valve 9-10978 and Large 2 Way Ball Valve 9-10980 this does not need to be the case anymore. The quick release airline valve is installed close to the detector. During maintenance the detector can be switched-off and the valve closed to prevent any damage to the detector during the clearing process. The low pressure compressed air can now be easily connected to the quick release.At the far end of the sampling pipe the large check valve or large 2 way ball valve can be used. The check value is the easiest to use as it will automatically open to release excess pressure during the cleaning process and does not require any human interaction. In some cases the check valve might not be suitable and then the 2 way ball valve can be used to manually open the far end of the sampling pipe.Key FeaturesEasy connection of airlineRobust ball valve to protect ASDFor use with 9-10978 - check valve

GBP 82.97
1

Kidde Airsense 34quot Large 2 Way Ball Valve 9-10980

Kidde Airsense 34quot Large 2 Way Ball Valve 9-10980

Kidde Airsense 34 Large 2 Way Ball Valve 9-10980When the aspirating smoke detection system is installed in a dirty or dusty environment the sampling pipes and sampling holes can get obscured over a period of time by the various airborne particles. As a result it is recommend to clean the sampling pipes and holes by blowing low pressure compressed air in the reverse direction through the sampling pipes. The connection of the compressed air to the sampling pipe and the release of excess air at the end of the sampling pipe can be cumbersome.With the Quick Release Airline Valve 9-30976 the Large Check Valve 9-10978 and Large 2 Way Ball Valve 9-10980 this does not need to be the case anymore. The quick release airline valve is installed close to the detector. During maintenance the detector can be switched-off and the valve closed to prevent any damage to the detector during the clearing process.The low pressure compressed air can now be easily connected to the quick release. At the far end of the sampling pipe the large check valve or large 2 way ball valve can be used. The check value is the easiest to use as it will automatically open to release excess pressure during the cleaning process and does not require any human interaction. In some cases the check valve might not be suitable and then the 2 way ball valve can be used to manually open the far end of the sampling pipe.Key FeaturesEasy maintenanceRobust ball valveFor use with 9-10976 - quick release airline valve

GBP 53.64
1

NC-DBO Conventional Beam Detector - Reflective

NC-DBO Conventional Beam Detector - Reflective

NC-DBO Conventional Beam Detector - ReflectiveThe NC-DBO is a reflective infrared beam smoke detector for use in conventional fire detection systems. Being microprocessor based the detector offers extensive algorithms for analysis and decision making. Taking ambient operating conditions into consideration system adjustments such as drift compensation and alarm and fault analysis are automatic. The sensitivity of the detector is adjustable to suit various application conditions.InstallationThe number of reflectors in a system varies depending on the required operating distance detection range of the detector. Optical reflectors from 1 to 4 provide an effective range of the detector between 5 and 100m. Four reflectors are supplied with the beam. The detection range of the beam can be selected from 4 levels with the hand held programmer NC-D-PT. For very short range detection 10 m a non reflective mask NRM9105 is recommended to attenuate the reflector.Key FeaturesWide operating voltage rangeLarge protection areaCombination of transmitter receiver in one housingallows for easy installation and optical alignmentIntelligent microprocessor based decision making on fire andfault statusesEasy alignment and commissioning with onboard laser andsignal level indicationSelf-diagnostics for monitoring reporting internalfailuresAutomatic drift compensation compensates for changingenvironmental conditions dust and dirt accumulation building movement andchanging internal component specifications due to ageingOnboard NO fire and NC fault dry contact outputs for easysupervisionFour selectable sensitivity levels for wideapplication coverage

GBP 426.44
1

NC-DPO-W Conventional Point Detector - Optical White

Kidde Airsense Relay Input Card 9-30436

NC-DPM-B Conventional Point Detector - OpticalHeat Black

NC-DPM-W Conventional Point Detector - OpticalHeat White

Kidde KE-DP3021W Excellence Series Intelligent Addressable Dual Optical SmokeHeat Detector - White

Kidde KE-DP3021W Excellence Series Intelligent Addressable Dual Optical SmokeHeat Detector - White

Kidde KE-DP3021W Excellence Series Intelligent Addressable Dual Optical SmokeHeat Detector - WhiteThe innovative Excellence range of intelligent addressable devices offers advanced features for reliability and peace of mind. Coupled with features for ease of installation and maintenance on new fire detection systems its a perfect match for exceptional overall performance.The DP3021B is a Kidde Excellence series graphite black addressable dual optical and heat detector. It combines a low profile design with tri-colour status indication with 360 visibility. A remote indicator output is available as standard that supports a remote indicator up to 30 m away.Detection reliability is ensured by combining dual optical wavelengths with multiple detection angles. This allows for state-of-the-art particle size detection that differentiates between real sources of alarm or nuisance sources such as dust and steam. As a temperature detector Class A static and rate-of-rise modes are supported to further widen the application footprint.Key FeaturesRemote indicator output with short circuit isolation for additional device protectionNuisance alarm steam dust discrimination for peace of mindStatic and rate-of-rise temperature supportTri-colour indicators for alarm pre alarm isolation fault. ItsMe and communications takes the guesswork out of operational status360 indicator visibility means no device alignment to ensure visibilityNew mechanical rotary addressing for easy addressingEvent logging in the device for diagnostics purposes when neededAll levels sensitivity EN54 certified

GBP 40.76
1

Kidde KE-DP3021B Excellence Series Intelligent Addressable Dual Optical SmokeHeat Detector - Black

Kidde KE-DP3021B Excellence Series Intelligent Addressable Dual Optical SmokeHeat Detector - Black

Kidde KE-DP3021B Excellence Series Intelligent Addressable Dual Optical SmokeHeat Detector - BlackThe innovative Excellence range of intelligent addressable devices offers advanced features for reliability and peace of mind. Coupled with features for ease of installation and maintenance on new fire detection systems its a perfect match for exceptional overall performance.The DP3021B is a Kidde Excellence series graphite black addressable dual optical and heat detector. It combines a low profile design with tri-colour status indication with 360 visibility. A remote indicator output is available as standard that supports a remote indicator up to 30 m away.Detection reliability is ensured by combining dual optical wavelengths with multiple detection angles. This allows for state-of-the-art particle size detection that differentiates between real sources of alarm or nuisance sources such as dust and steam. As a temperature detector Class A static and rate-of-rise modes are supported to further widen the application footprint.Key FeaturesRemote indicator output with short circuit isolation for additional device protectionNuisance alarm steam dust discrimination for peace of mindStatic and rate-of-rise temperature supportTri-colour indicators for alarm pre alarm isolation fault. ItsMe and communications takes the guesswork out of operational status360 indicator visibility means no device alignment to ensure visibilityNew mechanical rotary addressing for easy addressingEvent logging in the device for diagnostics purposes when neededAll levels sensitivity EN54 certified

GBP 55.85
1

Kidde KE-DP3121W Excellence Series Intelligent Addressable Dual Optical SmokeHeat Detector With ISO - White

Kidde KE-DP3121W Excellence Series Intelligent Addressable Dual Optical SmokeHeat Detector With ISO - White

Kidde KE-DP3121W Excellence Series Intelligent Addressable Dual Optical SmokeHeat Detector With ISO - WhiteThe innovative Excellence range of intelligent addressable devices offers advanced features for reliability and peace of mind. Coupled with features for ease of installation and maintenance on new fire detection systems its a perfect match for exceptional overall performance.The DP3121W is a Kidde Excellence series addressable dual optical and heat detector with integrated short circuit isolation. It combines a low profile design with tri-colour status indication with 360 visibility. A remote indicator output is available as standard that supports a remote indicator up to 30 m away.Detection reliability is ensured by combining dual optical wavelengths with multiple detection angles. This allows for state-of-the-art particle size detection that differentiates between real sources of alarm or nuisance sources such as dust and steam. As a temperature detector Class A static and rate-of-rise modes are supported to further widen the application footprint.Key FeaturesIntegrated loop short circuit isolation ensures operation during a single short circuit on the loopShort circuit isolation on remote output for additional device protectionNuisance alarm steam dust discrimination for peace of mindStatic and rate-of-rise temperature supportTri-colour indicators for alarm pre alarm isolation fault. ItsMe and communications takes the guesswork out of operational status360 indicator visibility means no device alignment to ensure visibilityNew mechanical rotary addressing for easy addressingEvent logging in the device for diagnostics purposes when neededAll levels sensitivity EN54 certified

GBP 48.86
1

Kidde KE-DP3121B Excellence Series Intelligent Addressable Dual Optical SmokeHeat Detector With ISO - Black

Kidde KE-DP3121B Excellence Series Intelligent Addressable Dual Optical SmokeHeat Detector With ISO - Black

Kidde KE-DP3121B Excellence Series Intelligent Addressable Dual Optical SmokeHeat Detector With ISO - BlackThe innovative Excellence range of intelligent addressable devices offers advanced features for reliability and peace of mind. Coupled with features for ease of installation and maintenance on new fire detection systems its a perfect match for exceptional overall performance.The DP3121B is a Kidde Excellence series graphite black addressable dual optical and heat detector with integrated short circuit isolation. It combines a low profile design with tri-colour status indication with 360 visibility. A remote indicator output is available as standard that supports a remote indicator up to 30 m away.Detection reliability is ensured by combining dual optical wavelengths with multiple detection angles. This allows for state-of-the-art particle size detection that differentiates between real sources of alarm or nuisance sources such as dust and steam. As a temperature detector Class A static and rate-of-rise modes are supported to further widen the application footprint.Key FeaturesIntegrated loop short circuit isolation ensures operation during a single short circuit on the loopShort circuit isolation on remote output for additional device protectionNuisance alarm steam dust discrimination for peace of mindStatic and rate-of-rise temperature supportTri-colour indicators for alarm pre alarm isolation fault. ItsMe and communications takes the guesswork out of operational status360 indicator visibility means no device alignment to ensure visibilityNew mechanical rotary addressing for easy addressingEvent logging in the device for diagnostics purposes when neededAll levels sensitivity EN54 certified

GBP 63.95
1

Kidde Airsense Stratos-Micra 25 Relay Input Card

Kidde Airsense Stratos-Micra 25 Relay Input Card

Stratos-Micra 25 Relay Input CardStratos-Micra 25 is intended to provide LOCALISED incipient fire detection only. This means that it is suitable for the substantial range of applications typified by small non-compartmentalised rooms warehouse racking or pieces of electronic or electromechanical equipment where it is desirable to achieve individual incipient fire reporting. In compartmentalised rooms each compartment would normally use individual Stratos-Micra 25 detectors.This product employs a very low-power aspirator and the aspirating capability of the Stratos-Micra 25 detector is limited accordingly. Stratos-Micra 25 is NOT intended to protect large areas or to sample from areas where there may be any difference in airflow rates or pressure differentials. Application of Stratos-Micra 25 in these circumstances is not recommended. If detection in environments conforming to these descriptions is required alternative versions of Stratos products should be used.We recommend a maximum sampling pipe length of 25 metres to be used on the Stratos-Micra 25. Maximum single length of sampling pipe to be used on the Stratos-Micra 100 detector is 100 metres or 2 x 50 meter lengths in still air with 25 sampling holes or Capillary Remote Sampling Points. This will provide a transport time from the end of the sampling pipe within 120 seconds. If the protected area has airflow present the maximum permitted sampling pipe length will be reduced.Key FeaturesUltra small low cost aspirating smoke detector for easy and discreet installationHigh sensitivity provide by laser based forward light scatter for reliable early warningSignal sampling pipe up to 50m in lengthUnique ClassiFire perceptive artificial intelligent system that dynamically adjusts the detectors operating parameters allowing for day to day changes in the protect environment and dust separation system contaminationUnwanted alarm from dust are avoided using patented Dual TechnologyLDD 3D Laser Dust Discrimination and elimination system

GBP 1285.96
1

Kidde Airsense Stratos-Micra 25 Basic Detector 9-30671

Kidde Airsense Stratos-Micra 25 Basic Detector 9-30671

Stratos-Micra 25 Basic Detector9-30671Stratos-Micra 25 is intended to provide LOCALISED incipient fire detection only. This means that it is suitable for the substantial range of applications typified by small non-compartmentalised rooms warehouse racking or pieces of electronic or electromechanical equipment where it is desirable to achieve individual incipient fire reporting. In compartmentalised rooms each compartment would normally use individual Stratos-Micra 25 detectors.This product employs a very low-power aspirator and the aspirating capability of the Stratos-Micra 25 detector is limited accordingly. Stratos-Micra 25 is NOT intended to protect large areas or to sample from areas where there may be any difference in airflow rates or pressure differentials. Application of Stratos-Micra 25 in these circumstances is not recommended. If detection in environments conforming to these descriptions is required alternative versions of Stratos products should be used.We recommend a maximum sampling pipe length of 25 metres to be used on the Stratos-Micra 25. Maximum single length of sampling pipe to be used on the Stratos-Micra 100 detector is 100 metres or 2 x 50 meter lengths in still air with 25 sampling holes or Capillary Remote Sampling Points. This will provide a transport time from the end of the sampling pipe within 120 seconds. If the protected area has airflow present the maximum permitted sampling pipe length will be reduced.Key FeaturesUltra small low cost aspirating smoke detector for easy and discreet installationHigh sensitivity provide by laser based forward light scatter for reliable early warningSignal sampling pipe up to 50m in lengthUnique ClassiFire perceptive artificial intelligent system that dynamically adjusts the detectors operating parameters allowing for day to day changes in the protect environment and dust separation system contaminationUnwanted alarm from dust are avoided using patented Dual TechnologyLDD 3D Laser Dust Discrimination and elimination system

GBP 1163.99
1

Kidde AirSense Stratos ModuLaser Detector Module 9-30783

Kidde AirSense Stratos ModuLaser Detector Module 9-30783

Kidde AirSense Stratos ModuLaser Detector Module 9-30783ModuLaser is a scalable aspirating smoke detection solution that makes installation easier maintenance quicker and takes applications further than traditional air sampling detectors. Two basic module types comprise the ModuLaser solution a display module and a detector module. Each detector module can accommodate up to 250 meters combined sampling pipe. Display modules and detector modules communicate by RS-485 interconnections.Display modules are available in three configurations Standard with TFT colour display status LEDs and navigation buttons Minimum with only status LEDs and Command which is similar to the Standard but with the added functionality to control various modules over SenseNET. The Minimum and Standard Display Modules can each support up to 8 detector modules while the Command Display Module can support up to 127 modules across the SenetNET network.Thanks to advanced features that make it virtually impervious to dust and dirt ModuLaser is ideal for use in hostile environments that would disable other kinds of smoke detectors. Forward scattering optical detection adds early warning capability without the risk of nuisance alarms normally associated with high sensitivity smoke detection while exclusive environmental compensation technology adds a high degree of reliability to an already solid detection solution.Key FeaturesModular Design Separate centrally-controllable detector modules allow efficient piping and discrete zones with no overlap.Zoned aspirating smoke detection Individual detector modules provide detection for individual areas or zones specific zone alarm information can be transmitted to the main fire alarm panel via a common APIC address card in the display module or through dedicated alarm relays within each detector module.Simplified installation Ingenious docking station design allows detectors to be easily connected together as a group. Sensitive electronics are easily removed to ensure they will not be damaged during first fix installation. Aspirating pipework and cable entries can easily be made into either the top or the bottom of the unit.Intuitive user interface Bright easy-to-see colour TFT display and universal navigation and control buttons take the guesswork out of programming and diagnostics.Easy pipe connection The quick fit pipe adaptor system locks down securely yet leaves plenty of room for easy pipe connection and removal.Quick location of smoke Each detector module is self-contained which means no delays in determining in which zone sampling pipe smoke is present.

GBP 856.82