25 results (0,13898 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Notifier NFS 4 Zone Conventional Fire Alarm Panel

Notifier NFS 8 Zone Conventional Fire Alarm Panel

Notifier NFS 2 Zone Conventional Fire Alarm Panel

Notifier 843090-0210 Bose FreeSpace 3 Series II Acoustimass Bass Module - White - Flush Mount

Notifier ECO1000BREL12NL Detector Base - System Sensor - Eco Relay

Notifier Honeywell DCSF1 Firemans Emergency Microphone Single Button 583504.RE

Notifier ECO Photoelectric Smoke Temperature Detector ECO1002A

Notifier WWL-PC-I02 Addressable EN54-23 Wall VAD - White Body amp White Flash

Notifier Honeywell ABT-DMS Zone Microphone

Notifier NFX-MM1M Addressable Mini Monitor input module

Notifier NFS3-EXT Single Area 3 Zone Extinguishant Control Panel

Notifier Honeywell 15 Watt Horn Loudspeaker 582479

Notifier Honeywell ABT-DMS-LCD Zone Microphone with LCD

Notifier NFS-10LU 10 Lamp Extinguishant Control Repeater

Notifier Honeywell SCU System Communication Unit 583381.31

Notifier ID3002 2 Loop Intelligent Fire Alarm Control Panel

Notifier ID3002 2 Loop Intelligent Fire Alarm Control Panel

Notifier ID3002 2 Loop Intelligent Fire Alarm Control PanelThe Notifier ID3000 family of fire alarm control panels deliver the power and flexibility to meet the even the most demanding of requirements. From 2 to 8 loops in a single ID3000 panel to over 500 loops on a network an ID3000 system offers unrivalled stability versatility and capacity. When it comes to giving you the earliest possible warning of a potential fire threat the ID3000 supports Notifiers comprehensive range of detectors advanced fire detection sensors and loop devices delivering you the most complete and versatile fire alarm system in the market place.The ID3000 can be programmed to adapt to the different uses of the areas where smoke detectors are installed. A total of 9 different sensitivity levels can be assigned to individual smoke sensors thereby allowing the system designer to closely match the sensors response to the environment in which the device is located. This even allows smoke detection to be turned off leaving heat detection active.Key Features2-8 Analogue Addressable Loops each of up to 198 devices255 Fire zones per panelFully approved peer to peer network of up to 63 panels maintains 3 second call point response time over the networkFlexible timer functions system sensitivity and functionality can be tailored for the time of day or day of weekSophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems.Convenience features for commissioning and maintenance engineers such as auto-learn of loops walk test and double address detection.CPD approved by LPCB BRE VdS

GBP 2933.30
1

Notifier ID60 Single Loop Intelligent Fire Alarm Panel 002-456

Notifier ID60 Single Loop Intelligent Fire Alarm Panel 002-456

Notifier ID60 Single Loop Intelligent Fire Alarm Panel 002-456The NOTIFIER ID60 Series Single Loop intelligent fire alarm panel has been developed for both installers and end users with efficiency in mind offering a technically advanced range of facilities and functions while remaining easy to install program and operate. Three models are available in the ID60 series. The compact ID60 the ID61 with internal printer option and a larger separate power supply and the ID62 with internal printer option a larger separate power supply and added space for 72 hours battery back-up.The ID60 series supports NOTIFIERs unique Very Intelligent Early Warning VIEW technology. Combined with the patented AWACS Advance Warning Addressable Combustion Sensing and DIG Dynamic Intelligent Grouping algorithms the ID60 series provides the most cost-effective stable and reliable early warning systems without the need to use costly aspirating detection systems.With A compact enclosure 380mm x 365mm x 110mm and a single PCB with on-board power supply 1.5A the ID60 provides the user with an easy to installmaintain Fire Alarm System.Key FeaturesLPCB approved to EN54 Parts 2 and 4One loop capacity 99 sensors and 99 modules16 fire zones 16 non fire zonesSupports advanced detection such as VIEW HARSH OptiPlex HAZARD64 CBE rules10 Pre-alarm levels per sensor9 Alarm levels per sensorDrift compensationMaintenance alertAutomatic High TestDay Night mode facilityTime programsClass ChangeAutolearn facilityOne man walk test2 x 40 character backlit LCDActive and passive repeatersProgrammable from the panel keypad or PCSupports loop powered sounders relaysTwo on board sounder circuitsTwo on board configurable outputs

GBP 1015.62
1

Notifier ID61 Single Loop Intelligent Fire Alarm Panel 002-463

Notifier ID61 Single Loop Intelligent Fire Alarm Panel 002-463

Notifier ID61 Single Loop Intelligent Fire Alarm Panel 002-463The NOTIFIER ID60 Series Single Loop intelligent fire alarm panel has been developed for both installers and end users with efficiency in mind offering a technically advanced range of facilities and functions while remaining easy to install program and operate. Three models are available in the ID60 series. The compact ID60 the ID61 with internal printer option and a larger separate power supply and the ID62 with internal printer option a larger separate power supply and added space for 72 hours battery back-up.The ID60 series supports NOTIFIERs unique Very Intelligent Early Warning VIEW technology. Combined with the patented AWACS Advance Warning Addressable Combustion Sensing and DIG Dynamic Intelligent Grouping algorithms the ID60 series provides the most cost-effective stable and reliable early warning systems without the need to use costly aspirating detection systems.The ID61 is housed in a slightly larger enclosure 500mm x 400mm x 110mm than the ID60 to accommodate for an internal mounted printer. A larger separate power supply 3A is fitted in the ID61 to cater for the more power hungry applications.Key FeaturesLPCB approved to EN54 Parts 2 and 4One loop capacity 99 sensors and 99 modules16 fire zones 16 non fire zonesSupports advanced detection such as VIEW HARSH OptiPlex HAZARD64 CBE rules10 Pre-alarm levels per sensor9 Alarm levels per sensorDrift compensationMaintenance alertAutomatic High TestDay Night mode facilityTime programsClass ChangeAutolearn facilityOne man walk test2 x 40 character backlit LCDActive and passive repeatersProgrammable from the panel keypad or PCSupports loop powered sounders relaysTwo on board sounder circuitsTwo on board configurable outputs

GBP 1808.16
1

Notifier ID62 Single Loop Intelligent Fire Alarm Panel 002-461

Notifier ID62 Single Loop Intelligent Fire Alarm Panel 002-461

Notifier ID62 Single Loop Intelligent Fire Alarm Panel 002-461The NOTIFIER ID60 Series Single Loop intelligent fire alarm panel has been developed for both installers and end users with efficiency in mind offering a technically advanced range of facilities and functions while remaining easy to install program and operate. Three models are available in the ID60 series. The compact ID60 the ID61 with internal printer option and a larger separate power supply and the ID62 with internal printer option a larger separate power supply and added space for 72 hours battery back-up.The ID60 series supports NOTIFIERs unique Very Intelligent Early Warning VIEW technology. Combined with the patented AWACS Advance Warning Addressable Combustion Sensing and DIG Dynamic Intelligent Grouping algorithms the ID60 series provides the most cost-effective stable and reliable early warning systems without the need to use costly aspirating detection systems.The ID62 is housed in a large enclosure 500mm x 620mm x 208mm to accommodate for an internal mounted printer and space for up to 42AH batteries for 72 hours battery backup. A larger separate power supply 3A is fitted in the ID62 to cater for the more power hungry applications and to provide enough power to support72 hours of battery 42AH backup should the mains AC power fail. Two front covers are provided on the ID62. One is fitted at the top part of the enclosure and one is fitted at the bottom part of the enclosure thereby allowing for easy installation and maintenance of the panel printer and batteries.Key FeaturesLPCB approved to EN54 Parts 2 and 4One loop capacity 99 sensors and 99 modules16 fire zones 16 non fire zonesSupports advanced detection such as VIEW HARSH OptiPlex HAZARD64 CBE rules10 Pre-alarm levels per sensor9 Alarm levels per sensorDrift compensationMaintenance alertAutomatic High TestDay Night mode facilityTime programsClass ChangeAutolearn facilityOne man walk test2 x 40 character backlit LCDActive and passive repeatersProgrammable from the panel keypad or PCSupports loop powered sounders relaysTwo on board sounder circuitsTwo on board configurable outputs

GBP 1872.25
1

Notifier ID3000 4 Loop Addressable Control Panel with 4.5A Power Supply 020-727

Notifier ID3000 4 Loop Addressable Control Panel with 4.5A Power Supply 020-727

Notifier ID3000 4 Loop Addressable Control Panel with 4.5A Power Supply 020-727The Notifier ID3000 family of fire alarm control panels deliver the power and flexibility to meet the even the most demanding of requirements. From 2 to 8 loops in a single ID3000 panel to over 500 loops on a network an ID3000 system offers unrivalled stability versatility and capacity. When it comes to giving you the earliest possible warning of a potential fire threat the ID3000 supports Notifiers comprehensive range of detectors advanced fire detection sensors and loop devices delivering you the most complete and versatile fire alarm system in the market place.The ID3000 can be programmed to adapt to the different uses of the areas where smoke detectors are installed. A total of 9 different sensitivity levels can be assigned to individual smoke sensors thereby allowing the system designer to closely match the sensors response to the environment in which the device is located. This even allows smoke detection to be turned off leaving heat detection active.Key Features2-8 Analogue Addressable Loops each of up to 198 devices255 Fire zones per panelFully approved peer to peer network of up to 63 panels maintains 3 second call point response time over the networkFlexible timer functions system sensitivity and functionality can be tailored for the time of day or day of weekSophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems.Convenience features for commissioning and maintenance engineers such as auto-learn of loops walk test and double address detection.CPD approved by LPCB BRE VdSKit Includes1 x 020-538 - Basic Equipment kit 2-8 Loops1 x 020-579 - 7A PSU 4.5A or 7A User selectable1 x 020-543- Dual transmittion path board kit1 x 020-588 - Dual loop board kit1 x 020-474-009 - Extended deep back-box kit Space for up to 38Ah batteries. H620mm W500mm D220mm.1 x 020-480-009 - Main cover kit1 x 020-485-009 - Extension cover blanking kit1 x 020-481-009 - Extension cover kit

GBP 4722.00
1

Notifier ID3000 4 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-730

Notifier ID3000 4 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-730

Notifier ID3000 4 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-730The Notifier ID3000 family of fire alarm control panels deliver the power and flexibility to meet the even the most demanding of requirements. From 2 to 8 loops in a single ID3000 panel to over 500 loops on a network an ID3000 system offers unrivalled stability versatility and capacity. When it comes to giving you the earliest possible warning of a potential fire threat the ID3000 supports Notifiers comprehensive range of detectors advanced fire detection sensors and loop devices delivering you the most complete and versatile fire alarm system in the market place.The ID3000 can be programmed to adapt to the different uses of the areas where smoke detectors are installed. A total of 9 different sensitivity levels can be assigned to individual smoke sensors thereby allowing the system designer to closely match the sensors response to the environment in which the device is located. This even allows smoke detection to be turned off leaving heat detection active.Key Features2-8 Analogue Addressable Loops each of up to 198 devices255 Fire zones per panelFully approved peer to peer network of up to 63 panels maintains 3 second call point response time over the networkFlexible timer functions system sensitivity and functionality can be tailored for the time of day or day of weekSophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems.Convenience features for commissioning and maintenance engineers such as auto-learn of loops walk test and double address detection.CPD approved by LPCB BRE VdSKit Contains1 x 020-538 - Basic Equipment kit 2-8 loops1 x 020-588 - Dual loop board kit1 x 020-579 - PSU 7A power supply 4.5A or 7A user selectable1 x 020-543 - Dual transmission path board kit1 x 020-474-009 - Extended deep back-box kit Space for up to 38Ah batteries. H620mm W500mm D220mm.1 x 020-480-009 - Main cover kit1 x 020-481-009 - Extension cover kit1 x 020-559-001 - Extension chassis kit. LED indications for zones 1-64. Space for internal printer

GBP 4599.50
1

Notifier ID3000 6 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-734

Notifier ID3000 6 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-734

Notifier ID3000 6 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-734The Notifier ID3000 family of fire alarm control panels deliver the power and flexibility to meet the even the most demanding of requirements. From 2 to 8 loops in a single ID3000 panel to over 500 loops on a network an ID3000 system offers unrivalled stability versatility and capacity. When it comes to giving you the earliest possible warning of a potential fire threat the ID3000 supports Notifiers comprehensive range of detectors advanced fire detection sensors and loop devices delivering you the most complete and versatile fire alarm system in the market place.The ID3000 can be programmed to adapt to the different uses of the areas where smoke detectors are installed. A total of 9 different sensitivity levels can be assigned to individual smoke sensors thereby allowing the system designer to closely match the sensors response to the environment in which the device is located. This even allows smoke detection to be turned off leaving heat detection active.Key Features2-8 Analogue Addressable Loops each of up to 198 devices255 Fire zones per panelFully approved peer to peer network of up to 63 panels maintains 3 second call point response time over the networkFlexible timer functions system sensitivity and functionality can be tailored for the time of day or day of weekSophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems.Convenience features for commissioning and maintenance engineers such as auto-learn of loops walk test and double address detection.CPD approved by LPCB BRE VdSKit Contains1 x 020-538 - Basic Equipment kit 2-8 loops2 x 020-588 - Dual loop board kit1 x 020-579 - PSU 7A power supply. 4.5A or 7A user selectable1 x 020-543- Dual transmission path board kit1 x 020-474-009 - Extended deep back-box kitspace for up to 38Ah batteries. H620mm W500mm D220mm.1 x 020-480-009 - Main cover kit1 x 020-481-009 - Extension cover kit1 x 020-559-001 - Extension chassis kit. LED indications for zones 1-64. Space for internal printer

GBP 5150.30
1

Notifier Honeywell DCSF12 Firemans Emergency Microphone 12 Buttons 583503.RE

Notifier Honeywell DCSF12 Firemans Emergency Microphone 12 Buttons 583503.RE

Notifier Honeywell DCSF12 Firemans Emergency Microphone 12 Buttons 583503.REIn many installation codes it is necessary to have redundancy in critical signal routes like speaker cables Loop or AB cabling between fire panel and the PAVA system. In some installation codes this includes also the connection to the fire men paging microphone.For very good reason because if the connection to the call station is lost there is no way for any live announcement to people which are potential or actually in high danger. Our paging station also supports redundant cable connection to two separate Comprio not standalone Version of Comprio or DOMs which means its possible to connect two cables CAT5 to one paging station. The digital paging microphone DCSF12 serves for the selection of loudspeaker circuits and for setting off speech announcements as well as various gong or alarm sounds.It features 12 freely configurable keys 13 LED and a handheld microphone. The paging microphone is connected with our DAL Digital Audio Link bus to a Comprio or DOM by means of a standard CAT5 cable. All audio signals and all control signals are transmitted digitally. The function of the digital paging microphone is permanently acoustically monitored. Up to four DAL bus links can be connected to a DOM.Every digital call station in the system can simultaneously generate and receive different voice transmissions and control signals. A digital paging microphone can be offset up to 300 m by means of a CAT5 cable. Extension to a greater distance is possible with fiber optic FO cables - see respective FO converters which are needed additionally. Also a connection with FO cables can be done redundant. If more keys andor LEDs are needed it is possible to add up to six digital key modules DKM18 which allows the increase of the total number of available keys and LEDs to 120 per call station.Key FeaturesHigh failure safety due to redundant transmission routeHand-held microphone with built-in loudspeaker and acoustic microphone monitoringPermanent monitoring of the line to the next interface module24-bit ADDA converter12 freely configurable keysAdditional LED programmable in yellow or redCan be used redundantly as well as non- redundantly

GBP 2068.56
1

Notifier ID3000 8 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-738

Notifier ID3000 8 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-738

Notifier ID3000 8 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-738The Notifier ID3000 family of fire alarm control panels deliver the power and flexibility to meet the even the most demanding of requirements. From 2 to 8 loops in a single ID3000 panel to over 500 loops on a network an ID3000 system offers unrivalled stability versatility and capacity. When it comes to giving you the earliest possible warning of a potential fire threat the ID3000 supports Notifiers comprehensive range of detectors advanced fire detection sensors and loop devices delivering you the most complete and versatile fire alarm system in the market place.The ID3000 can be programmed to adapt to the different uses of the areas where smoke detectors are installed. A total of 9 different sensitivity levels can be assigned to individual smoke sensors thereby allowing the system designer to closely match the sensors response to the environment in which the device is located. This even allows smoke detection to be turned off leaving heat detection active.Key Features2-8 Analogue Addressable Loops each of up to 198 devices255 Fire zones per panelFully approved peer to peer network of up to 63 panels maintains 3 second call point response time over the networkFlexible timer functions system sensitivity and functionality can be tailored for the time of day or day of weekSophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems.Convenience features for commissioning and maintenance engineers such as auto-learn of loops walk test and double address detection.CPD approved by LPCB BRE VdSKit Contains1 x 020-538 - Basic Equipment kit 2-8 loops3 x 020-588 - Dual loop board kit1 x 020-579 - PSU 7A power supply. 4.5A or 7A user selectable1 x 020-543- Dual transmission path board kit1x 020-548 - Optional status indicator board kit for 7A PSU1 x 020-473-009 - Extended back-box kit Space for up to 17Ah batteries. H620mm W500mm D122mm.1 x 020-480-009 - Main cover kit1 x 020-481-009 - Extension cover kit1 x 020-559-001 - Extension chassis kit. LED indications for zones 1-64. Space for internal printer1 x 020-541-009 - 7A PSU78AH battery cabinet kit

GBP 6122.94
1