7 results (0,12418 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Scope RTESTPB Range Testing Kit For Pendant PEN4 Wave Track amp PB1BPB2B Panic Buttons With Transponder

Scope PTPRO2R PageTek Pro 2 Paging transmitter

Scope PTPRO2R PageTek Pro 2 Paging transmitter

Please note The image is for illustrative purposes only - thistransmitter does not come with an aerial included. Compatible aerials can bepurchased separately please see related products below.Scope PTPRO2R PageTek Pro 2 Paging transmitterThe PTPRO2R manufactured by Scope is a high-power pagetransmitter for hard of hearing.Scope PageTek Pro 2 Industrial Strength paging systems designed for use with professional Fire and Security systems installed in commercialindustrial premises. The system is primarily designed to alert the hearing impaired in the event of a fire or other emergency where an audible sounder is the normal means of indication. Main users include factories offices universities schools hospitals hotels and public buildings.The Pagetek Pro System is designed to comply with the recommendations detailed in BS5839-1 2013 for alerting the hearing impaired to the activation of a Fire Alarm System. The system can also be used in conjunction with a security alarm panel to alert guards who might be located remote from the main premises.The interface to the host Fire alarm system comprises of multiple prioritised Fire inputs and a further input to provide for fault indication from the Fire panel. For ease of installation a monitored interface cable is provided with the system which also includes a common fault relay output back to the host Fire alarm panel. This will activate if the PageTek Pro suffers a mains failure transmitter fault antenna mismatch link failure low battery or missing battery condition.Upon activation of any Fire Zone input the PageTek Pro system will enter the fire alert condition prioritising and transmitting the Fire message to all pagers. The transmissions will be repeated until the fire condition is reset. Special format Scope pagers ensure that users are alerted by distinct vibrate patterns and clear text messages.Key Features2.0W RF outputRequires aerial pagers 18Ah batteryBS5839-1 certifiedUHF radio link for maximum licensable protectionUnique coding avoids neighbouring system clashesSelf-monitoring of system healthRugged steel enclosure to IP65Backlit 2 line Text Display continuously reports system statusAdditional Visible Audible status indicatorsPrioritised Fire Alarm Inputs and Fault inputsAutomated test calls alert pagers to loss of radio signalFault notification to the host Control Equipment via monitored linkKey locked System Test facility for routine confidence checkingOver 90 hours backup operation with internally fitted batteryAdd on AnswerTek Pro receiver system for additional monitoring reporting of radio signal IntegrityRS232 serial input for other messagingOptional Ethernet card and additional RS232 inputHigh power transmitter provides 2w ERP RF output for enhanced coverage of large sites

GBP 1731.60
1

Scope PTPRO2RM PageTek Pro 2 High Power Paging Transmitter

Scope PTPRO2RM PageTek Pro 2 High Power Paging Transmitter

Please contact us to confirm panel compatibility andconfiguration before orderingScope PTPRO2RM PageTek Pro 2 High Power Paging TransmitterThe PTPRO2RM manufactured by Scope is a high-power pagetransmitter for hard of hearing.Scope PageTek Pro 2 Industrial Strength paging systems designed for use with professional Fire and Security systems installed in commercialindustrial premises. The system is primarily designed to alert the hearing impaired in the event of a fire or other emergency where an audible sounder is the normal means of indication. Main users include factories offices universities schools hospitals hotels and public buildings.The Pagetek Pro System is designed to comply with the recommendations detailed in BS5839-1 2013 for alerting the hearing impaired to the activation of a Fire Alarm System. The system can also be used in conjunction with a security alarm panel to alert guards who might be located remote from the main premises.The interface to the host Fire alarm system comprises of multiple prioritised Fire inputs and a further input to provide for fault indication from the Fire panel. For ease of installation a monitored interface cable is provided with the system which also includes a common fault relay output back to the host Fire alarm panel. This will activate if the PageTek Pro suffers a mains failure transmitter fault antenna mismatch link failure low battery or missing battery condition.Upon activation of any Fire Zone input the PageTek Pro system will enter the fire alert condition prioritising and transmitting the Fire message to all pagers. The transmissions will be repeated until the fire condition is reset. Special format Scope pagers ensure that users are alerted by distinct vibrate patterns and clear text messages.Key Features2.0W RF output with serial input from third-party panelRequires aerial pagers 18Ah batteryBS5839-1 certifiedUHF radio link for maximum licensable protectionUnique coding avoids neighbouring system clashesSelf-monitoring of system healthRugged steel enclosure to IP65Backlit 2 line Text Display continuously reports system statusAdditional Visible Audible status indicatorsPrioritised Fire Alarm Inputs and Fault inputsAutomated test calls alert pagers to loss of radio signalFault notification to the host Control Equipment via monitored linkKey locked System Test facility for routine confidence checkingOver 90 hours backup operation with internally fitted batteryAdd on AnswerTek Pro receiver system for additional monitoring reporting of radio signal IntegrityRS232 serial input for other messagingOptional Ethernet card and additional RS232 inputHigh power transmitter provides 2w ERP RF output for enhanced coverage of large sitesPlease note The image is for illustrative purposes only - thistransmitter does not come with an aerial included. Compatible aerials can bepurchased separately please see related products below.

GBP 1825.20
1

Scope PTPRO2L PageTek Pro 2 Paging Transmitter For The Hard Of Hearing - 1.0W RF Output

Scope PTPRO2L PageTek Pro 2 Paging Transmitter For The Hard Of Hearing - 1.0W RF Output

Please note The image is for illustrative purposes only - this transmitter does not come with an aerial included. Compatible aerials can be purchased separately please see related products below.Scope PTPRO2L PageTek Pro 2 Paging Transmitter For The Hard Of Hearing - 1.0W RF OutputThe PTPRO2L is a PageTek Pro 2 Paging Transmitter For The Hard Of Hearing - 1.0W RF Output.Scope PageTek Pro 2 Industrial Strength paging systems designed for use with professional Fire and Security systems installed in commercialindustrial premises. The system is primarily designed to alert the hearing impaired in the event of a fire or other emergency where an audible sounder is the normal means of indication. Main users include factories offices universities schools hospitals hotels and public buildings.The Pagetek Pro System is designed to comply with the recommendations detailed in BS5839-1 2013 for alerting the hearing impaired to the activation of a Fire Alarm System. The system can also be used in conjunction with a security alarm panel to alert guards who might be located remote from the main premises.The interface to the host Fire alarm system comprises of multiple prioritised Fire inputs and a further input to provide for fault indication from the Fire panel. For ease of installation a monitored interface cable is provided with the system which also includes a common fault relay output back to the host Fire alarm panel. This will activate if the PageTek Pro suffers a mains failure transmitter fault antenna mismatch link failure low battery or missing battery condition.Upon activation of any Fire Zone input the PageTek Pro system will enter the fire alert condition prioritising and transmitting the Fire message to all pagers. The transmissions will be repeated until the fire condition is reset. Special format Scope pagers ensure that users are alerted by distinct vibrate patterns and clear text messages.Key FeaturesUHF radio link for maximum licensable protectionUnique coding avoids neighbouring system clashesSelf-monitoring of system healthRugged steel enclosure to IP65Backlit 2 line Text Display continuously reports system statusAdditional Visible Audible status indicatorsPrioritised Fire Alarm Inputs and Fault inputsAutomated test calls alert pagers to loss of radio signalFault notification to the host Control Equipment via monitored linkKey locked System Test facility for routine confidence checkingOver 90 hours backup operation with internally fitted batteryAdd on AnswerTek Pro receiver system for additional monitoring reporting of radio signal IntegrityRS232 serial input for other messagingOptional Ethernet card and additional RS232 inputHigh power transmitter provides 2w ERP RF output for enhanced coverage of large sites

GBP 1638.00
1

Scope PTPRO2LM PageTek Pro 2 Paging Transmitter For The Hard Of Hearing - With Serial

Scope PTPRO2LM PageTek Pro 2 Paging Transmitter For The Hard Of Hearing - With Serial

Please note The image is for illustrative purposes only - thistransmitter does not come with an aerial included. Compatible aerials can bepurchased separately please see related products below.Scope PTPRO2LM PageTek Pro 2 Paging Transmitter For The Hard Of Hearing - With SerialThe PTPRO2LM is a PageTek Pro 2 Paging Transmitter For The Hard Of Hearing - With Serial.Scope PageTek Pro 2 Industrial Strength paging systems designed for use with professional Fire and Security systems installed in commercialindustrial premises. The system is primarily designed to alert the hearing impaired in the event of a fire or other emergency where an audible sounder is the normal means of indication. Main users include factories offices universities schools hospitals hotels and public buildings.The Pagetek Pro System is designed to comply with the recommendations detailed in BS5839-1 2013 for alerting the hearing impaired to the activation of a Fire Alarm System. The system can also be used in conjunction with a security alarm panel to alert guards who might be located remote from the main premises.The interface to the host Fire alarm system comprises of multiple prioritised Fire inputs and a further input to provide for fault indication from the Fire panel. For ease of installation a monitored interface cable is provided with the system which also includes a common fault relay output back to the host Fire alarm panel. This will activate if the PageTek Pro suffers a mains failure transmitter fault antenna mismatch link failure low battery or missing battery condition.Upon activation of any Fire Zone input the PageTek Pro system will enter the fire alert condition prioritising and transmitting the Fire message to all pagers. The transmissions will be repeated until the fire condition is reset. Special format Scope pagers ensure that users are alerted by distinct vibrate patterns and clear text messages.Key FeaturesUHF radio link for maximum licensable protectionUnique coding avoids neighbouring system clashesSelf-monitoring of system healthRugged steel enclosure to IP65Backlit 2 line Text Display continuously reports system statusAdditional Visible Audible status indicatorsPrioritised Fire Alarm Inputs and Fault inputsAutomated test calls alert pagers to loss of radio signalFault notification to the host Control Equipment via monitored linkKey locked System Test facility for routine confidence checkingOver 90 hours backup operation with internally fitted batteryAdd on AnswerTek Pro receiver system for additional monitoring reporting of radio signal IntegrityRS232 serial input for other messagingOptional Ethernet card and additional RS232 inputHigh power transmitter provides 2w ERP RF output for enhanced coverage of large sites

GBP 1731.60
1

Scope F-Link 1224v Additional Fully Monitored Telemetry Transceiver FLINK4

Scope F-Link 1224v Additional Fully Monitored Telemetry Transceiver FLINK4

Scope F-Link 1224v Additional Fully Monitored Telemetry Transceiver FLINK4The original Scope F-Link system has become a popular and secure way of remotely alerting and monitoring fire or security panels. The latest version adds even greater performance and improved functionality. F-Link is now housed in a larger case with plenty of cable entry points and an informative text display which provides status information and gives details of alarm messages.A system consists of two or more F-Link units working together to form a mesh network with each unit operating as both a transmitter and receiver. The radio link between units is monitored for faults in accordance with the relevant sections of BS5839-12017 24.2b and BSEN54-252008 4.2.6. There is an additional output on the Master unit for connection to an optional paging transmitter which sends alarm and fault messages to pocket pagers.Key FeaturesMesh network signalling technologyUp to 16 F-Link units can be networkedFully supervised with high immunitySelf-healing for quick and easy unit replacementInformative LCD text displayDIP switch configuration no bespoke factory programming necessaryLink monitoring in accordance with the relevant sections of BS5839-12017 24.2b and BSEN54-252008 4.2.6Comes with 14SMA quarter wave aerial - alternative aerials can be bought separatelyAdditional FeaturesThe front panel display indicates active zones unit status networkradio status and the received signal strength of incoming transmissions. A button is provided to mute the internal fault sounder and a key switch allows the unit to be reset or placed into test mode. The Identity and radio operating frequency of each unit is set using dip switches allowing for rapid and fuss-free installation.Software-configurable options include text descriptors for each Node and each zone event zone input type and output relay operating mode. Programmed settings are wirelessly distributed by the Master unit to all installed Nodes. An optional F-Link paging transmitter can be added to the system to send alarm and fault event descriptions to portable radio pagers. An optional interface can also be specified to provide a serial data output for logging purposes.

GBP 819.00
1

Scope F-Link 1224v Fully Monitored Telemetry Transceivers FLINK4KIT

Scope F-Link 1224v Fully Monitored Telemetry Transceivers FLINK4KIT

Scope F-Link FLINK4KIT 1224v Fully Monitored Telemetry TransceiversThe original Scope F-Link system has become a popular and secure way of remotely alerting and monitoring fire or security panels. The latest version adds even greater performance and improved functionality. F-Link is now housed in a larger case with plenty of cable entry points and an informative text display which provides status information and gives details of alarm messages.A system consists of two or more F-Link units working together to form a mesh network with each unit operating as both a transmitter and receiver. The radio link between units is monitored for faults in accordance with the relevant sections of BS5839-12017 24.2b and BSEN54-252008 4.2.6. There is an additional output on the Master unit for connection to an optional paging transmitter which sends alarm and fault messages to pocket pagers.Key FeaturesMesh network signalling technologyUp to 16 F-Link units can be networkedFully supervised with high immunitySelf-healing for quick and easy unit replacementInformative LCD text displayDIP switch configuration no bespoke factory programming necessaryLink monitoring in accordance with the relevant sections of BS5839-12017 24.2b and BSEN54-252008 4.2.6Comes with 14SMA quarter wave aerial - alternative aerials can be bought separatelyAdditional FeaturesThe front panel display indicates active zones unit status networkradio status and the received signal strength of incoming transmissions. A button is provided to mute the internal fault sounder and a key switch allows the unit to be reset or placed into test mode. The Identity and radio operating frequency of each unit is set using dip switches allowing for rapid and fuss-free installation.Software-configurable options include text descriptors for each Node and each zone event zone input type and output relay operating mode. Programmed settings are wirelessly distributed by the Master unit to all installed Nodes. An optional F-Link paging transmitter can be added to the system to send alarm and fault event descriptions to portable radio pagers. An optional interface can also be specified to provide a serial data output for logging purposes.

GBP 1638.00
1