103 results (0,14649 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Vesda Xtralis Tamper Proof Sampling Point VSP-610

Vesda Xtralis PIP-027 Air Sampling Test Point with Cap

Vesda Xtralis Tamper Proof Sampling Point - 8mm Tube Inlet VSP-620-02

Vesda Xtralis Tamper Proof Sampling Point - 6mm Tube Inlet VSP-620-01

Vesda Xtralis Tamper Proof Sampling Point - 10mm Tube Inlet VSP-620-03

Vesda Xtralis 25mm Air Sampling Test Point - Pack of 10

Vesda Xtralis Smoke Pen VSP-810

Vesda Xtralis Smoke Pen REFILL VSP-811

Vesda Xtralis REDFLEXI25B 25mm Flexible 1m Long Bend

Vesda Xtralis REDFLEXI25B 25mm Flexible 1m Long Bend

Vesda Xtralis REDFLEXI25B 25mm Flexible 1m Long BendWith over 250000 aspirating smoke detectors installed worldwide the VESDA name has become synonymous with high quality and outstanding performance. An aspirating smoke detection system however only performs at its best with a well designed and installed quality pipework system. Xtralis manufacturer of VESDA detectors recognised this requirement and in 1997 launched its VESDA Pipe and Fittings range.Always use tools specifically designed forplastic pipe.Protective gloves are recommended for usewhen solvent cementing. If hands come into contact with cement use a waterless abrasive soap.Avoid sources of heat or open flames when solvent cementing. Do not smoke.Always chamfer and deburr pipe ends.Use the proper solvent cement note air shipments of solvent cement are forbidden by law.Always replace lids on cans when not in use.Never dilute solvent cement.Keep jointing surfaces dry in wet weather.Avoid direct inhalation of fumes. Use in a well-ventilated area.Wipe up spills or leaks immediately with clean lint free cloth or paper towels.Follow recommended cure times prior to testing the system.Prevent excessive solvent cement from running into the pipe or fitting socket.The Integrity of air sampling systems may be affected if proper CPVC solvent cement is not used. The Safety Crewdisclaims responsibility for any air sampling pipe system constructed with cements other than those recommended.Please note The PIP-021 is equivalent to the REDFLXI25B.

GBP 24.38
1

Vesda Xtralis 25mm Flexible 1m Long Bend

Vesda Xtralis 25mm Flexible 1m Long Bend

Vesda Xtralis 25mm Flexible 1m Long BendWith over 250000 aspirating smoke detectors installed worldwide the VESDA name has become synonymous with high quality and outstanding performance. An aspirating smoke detection system however only performs at its best with a well designed and installed quality pipework system. Xtralis manufacturer of VESDA detectors recognised this requirement and in 1997 launched its VESDA Pipe and Fittings range.Always use tools specifically designed forplastic pipe.Protective gloves are recommended for usewhen solvent cementing. If hands come into contact with cement use a waterless abrasive soap.Avoid sources of heat or open flames when solvent cementing. Do not smoke.Always chamfer and deburr pipe ends.Use the proper solvent cement note air shipments of solvent cement are forbidden by law.Always replace lids on cans when not in use.Never dilute solvent cement.Keep jointing surfaces dry in wet weather.Avoid direct inhalation of fumes. Use in a well-ventilated area.Wipe up spills or leaks immediately with clean lint free cloth or paper towels.Follow recommended cure times prior to testing the system.Prevent excessive solvent cement from running into the pipe or fitting socket.The Integrity of air sampling systems may be affected if proper CPVC solvent cement is not used. The Safety Crewdisclaims responsibility for any air sampling pipe system constructed with cements other than those recommended.Please note The PIP-021 is equivalent to the REDFLXI25B.

GBP 24.38
1

Vesda-E VEA VEA-040-A10 40-Tube Addressable Detector with 3.5quot Touchscreen Display

Vesda-E VEA VEA-040-A10 40-Tube Addressable Detector with 3.5quot Touchscreen Display

Vesda-E VEA VEA-040-A10 40-Tube Addressable Detector with 3.5 Touchscreen DisplayThe VESDA-E VEA-040-A10 is an aspirating smoke detector ASD that provides early warning of fire conditions by drawing air samples through a multi-hole addressable microbore tube air-sampling network.The detector easily interfaces with fire warning and fire suppression release systems and can be integrated into a building management system BMS.Key FeaturesThe VEA-040-A10 detector contains the following featuresPinpoint addressability with superior detection compared to spot detectors40 addressable microbore tubes with individual sampling pointsAssured detection with end to end system integrity monitoringInterruption-free business operation with centralized testing and maintenanceSingle sampling point or single tube blockage detectionAutomatic sampling point cleaningThree sensitivity settings for the sampling pointsVariable length capillary tubes up to 100 m 328 ftLaser-based absolute smoke detectionDual stage filtering and clean air barrier for optics protectionReliable linear pump technologyLEDs for alarm and fault signalling3.5 colour touch screen for status reviewSeven programmable relaysTwo GPIs monitored and unmonitoredPC software supportiVESDA app for system monitoring on mobile devicesIP 40 enclosure not UL testedEasy mounting with steel support bracketField replaceable filter smoke sensor module pump and rotary valveVESDAnet networkingEthernet 100 base TWiFi 802.11 bgnLocal host-mode USB portEasy cable termination accessEvent Log 20000 events

GBP 8241.78
1

Vesda-E VEA VEA-040-A00 40-Tube Addressable Detector with LEDs Display

Vesda-E VEA VEA-040-A00 40-Tube Addressable Detector with LEDs Display

Vesda-E VEA VEA-040-A00 40-Tube Addressable Detector with LEDs DisplayThe VESDA-E VEA-040-A10 is an aspirating smoke detector ASD that provides early warning of fire conditions by drawing air samples through a multi-hole addressable microbore tube air-sampling network.The detector easily interfaces with fire warning and fire suppression release systems and can be integrated into a building management system BMS.Key FeaturesThe VEA-040-A10 detector contains the following featuresPinpoint addressability with superior detection compared to spot detectors40 addressable microbore tubes with individual sampling pointsAssured detection with end to end system integrity monitoringInterruption-free business operation with centralized testing and maintenanceSingle sampling point or single tube blockage detectionAutomatic sampling point cleaningThree sensitivity settings for the sampling pointsVariable length capillary tubes up to 100 m 328 ftLaser-based absolute smoke detectionDual stage filtering and clean air barrier for optics protectionReliable linear pump technologyLEDs for alarm and fault signalling3.5 colour touch screen for status reviewSeven programmable relaysTwo GPIs monitored and unmonitoredPC software supportiVESDA app for system monitoring on mobile devicesIP 40 enclosure not UL testedEasy mounting with steel support bracketField replaceable filter smoke sensor module pump and rotary valveVESDAnet networkingEthernet 100 base TWiFi 802.11 bgnLocal host-mode USB portEasy cable termination accessEvent Log 20000 events

GBP 7487.12
1

Vesda VSP-001 VLP amp VLS Programmer Module

Vesda VHH-100 Hand Held Programmer Complete with Lead

Vesda VHH-100 Hand Held Programmer Complete with Lead

Vesda VHH-100 Hand Held Programmer Complete with LeadThe Programmer Module allows direct access to all VESDAnet devices on an VESDA smoke detection system. It allows configuration and status reporting of detectors displays and interfaces and is required when installing commissioning and maintaining a VESDA network. By incorporating a user friendly menu navigation through the comprehensive features of VESDAnet is convenient and simple.The programmer module is available as a hand-held device with included DB15 serial cable or can be mounted into a VESDA VLP or VESDA VLS detector a remote mounting box or a 19 inch sub rack.The two rows of large push buttons enable the user to log ON and navigate through the menu trees to the various command and parameter setting functions. The top row of keys are called Soft Keys and are assigned programming options appropriate to the screen being viewed.Some of the parameters that can be accessed via the programmer include device status reporting zone number and name allocation flow normalisation alarm threshold setting day night weekend initiation of AutoLearn wiring order relay testing and event log review.Up to 14 assigned Users or Administrators with an individual 4 digit Personal Identification Number PIN and one Distributor can log onto a VESDAnet system under one of three levels of access which are password protectedUser USR is only able to view parameters check status alarms and reset the system.Administrator ADM has access to most commands and programming parameters.Distributor DST is the topmost level and has unlimited access to all commands and parameters in the system.Lost PIN numbers can be overcome by obtaining a once only pass number from your Xtralis VESDA dealer.The programmer automatically logs OFF when not in use for more than 10 minutes. The user is prompted with a beeping sound at 1 minute and at 15 seconds before log OFF. Any key may be pressed to cancel the automatic log OFF process.Key FeaturesUser friendly menu systemSupports multiple languagesSingle point access to entire VESDAnet systemAlarm and fault simulationShows wiring orderLocates communications failuresPassword securityHand held or remote mountingAutomatic Logoff when inactiveBacklit LCD screen

GBP 919.70
1

Vesda VRT-100 Remote Mount Programmer

Vesda VRT-100 Remote Mount Programmer

Vesda VRT-100 Remote Mount ProgrammerThe Programmer Module allows direct access to all VESDAnet devices on an VESDA smoke detection system. It allows configuration and status reporting of detectors displays and interfaces and is required when installing commissioning and maintaining a VESDA network. By incorporating a user friendly menu navigation through the comprehensive features of VESDAnet is convenient and simple.The programmer module is available as a hand-held device with included DB15 serial cable or can be mounted into a VESDA VLP or VESDA VLS detector a remote mounting box or a 19 inch sub rack. The two rows of large push buttons enable the user to log ON and navigate through the menu trees to the various command and parameter setting functions. The top row of keys are called Soft Keys and are assigned programming options appropriate to the screen being viewed.Some of the parameters that can be accessed via the programmer include device status reporting zone number and name allocation flow normalisation alarm threshold setting day night weekend initiation of AutoLearn wiring order relay testing and event log review. Up to 14 assigned Users or Administrators with an individual 4 digit Personal Identification Number PIN and one Distributor can log onto a VESDAnet system under one of three levels of access which are password protectedUser USR is only able to view parameters check status alarms and reset the system.Administrator ADM has access to most commands and programming parameters.Distributor DST is the topmost level and has unlimited access to all commands and parameters in the system.Lost PIN numbers can be overcome by obtaining a once only pass number from your Xtralis VESDA dealer.The programmer automatically logs OFF when not in use for more than 10 minutes. The user is prompted with a beeping sound at 1 minute and at 15 seconds before log OFF. Any key may be pressed to cancel the automatic log OFF process.Key FeaturesUser friendly menu systemSupports multiple languagesSingle point access to entire VESDAnet systemAlarm and fault simulationShows wiring orderLocates communications failuresPassword securityHand held or remote mountingAutomatic Logoff when inactiveBacklit LCD screen

GBP 955.28
1

Vesda Xtralis OSID-WG OSID Wire Guard

Vesda Xtralis LT-ACC-HUB-PWR-HON Hub Direct Power LT Gen 3

Vesda VIC-010 VESDAnet Card for VLF-250 amp VLF-500

Vesda-E VEA VER-A40-40-STX 40-Relay Local StaX Silver

Vesda Xtralis 25mm Sight Glass with Condensation Drain PIP-033

Xtralis OSE-ACF OSID Anti-Condensation Film for Emitter Pack of 10

Xtralis OSE-ACF OSID Anti-Condensation Film for Emitter Pack of 10

Xtralis OSE-ACF OSID Anti-Condensation Film for Emitter Pack of 10Pack of 10 anti-condensation films designed for OSID Emitters.Emitters are equipped with an acrylic lens and are therefore not normally prone to condensation. However in some extremely moist environments condensation may nevertheless occur on the lens. Slow forming condensation can produce an unacceptably large loss of signal. To prevent that from occurring the Emitter lens can be fitted with an anti-condensation film. The film can be quickly and easily applied to the lens without the need for special tools or adhesives.The film prevents condensation from forming and keeps the lens clear. Note however that the film causes a 10 reduction in maximum detection distance. A damp cloth can be used to clean the film if it becomes contaminated. The combination of the film and the algorithms in the Imager offer a cost-effective solution for condensation susceptible areas. The OSID Imager has a built-in heater and the film should not be used on Imagers.In harsh environments where the OSID-EH environmental housings are used and condensation is expected both Emitter and Imager housing can be fitted with an anti-condensation film. When applied on Emitter and Imager housing there is a 20 reduction in maximum detection distance.Key FeaturesPrevents condensationFast and easy installationSimple maintenanceLong lifetimeHighly scratch resistantDoes not crack peel or discolour from exposure to sunlightEasy to clean using cleaning solvents

GBP 184.85
1

Vesda VHX-1200 VESDAnet Socket with HLI in Metal Enclosure

Vesda VHX-1200 VESDAnet Socket with HLI in Metal Enclosure

Vesda VHX-1200 VESDAnet Socket with HLI in Metal EnclosureThe VESDA Wall-Mounted High Level Interface HLI links your VESDAnet with PC software monitoring and configuring tools such as Xtralis VSM4 and Xtralis VSC. The HLI includes a built-in VESDAnet socket card.Direct Access to the NetworkBy interfacing with PC monitoring and configuring tools the Wall-mounted HLI allows you to easily configure manage and monitor your entire VESDA network. The built-in VESDAnet socket card makes the Wall-mounted HLI a cost effective solution to your interface requirements. The Wall-mounted HLI receives its voltage supply of 24VDC from the VESDAnet socket card. Therefore an additional power supply is not required.Remote InstallationConnecting to your VESDAnet is easy and convenient because the wall-mounted HLI does not need to be mounted near an VESDA smoke detector. The wall-mounted HLI can be mounted in an easy-to-access remote location away from your detectors such as on a wall near your PC.Simple Configuration and Seamless Data TransferYour HLI is easily configured using your PC and Xtralis VSC or Xtralis VSM4 software packages. The Wall-mounted HLI VHX-1200 provides seamless data transfer from your VESDAnet to your PC.Key FeaturesDirect access and monitoring of your entire VESDAnet systemBuilt-in VESDAnet Interface socket card provides communication and power to the HLIConvenient wall-mounted designSeamless data transfer on networks of up to 200 VESDA devicesEasily configured using Xtralis configuring and monitoring software packages

GBP 1222.97