264 results (0,14124 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Zeta AEMBR026 Z amp L Bracket For AEM10010 - Inward Open Door

Zeta ZIS-40 Base for Intrinsically Safe Smoke Detector

Zeta SCM-DLEM Datalog Editor For Multiple Sites

Zeta ZT-MNS-100BAS 100 Watt Voice Evacuation Panel With 4 Speaker Circuits

Zeta ZT-MNS-100BAS 100 Watt Voice Evacuation Panel With 4 Speaker Circuits

Zeta ZT-MNS-100BAS 100 Watt Voice Evacuation Panel With 4 Speaker CircuitsThe Zeta ZT-MNS-100BAS is a modular voice evacuation system ideally suited as an extension to an existing fire alarm system.The ZT- MNS-100BAS accommodates virtually any host alarm system integrating as quickly and easily as a single primary connection to an alarm circuit output from the FACP.Many of the pre-set configurations will provide a complete voice evacuation capability right out of the box.Additional activation is by a single supervised input from a dry contact closure.Numerous audio inputs are provided for maximum control flexibility and system access. A supervised remote microphone input is provided for central placement for emergency personnel.A high priority supervised audio input is provided that overrides lower priority activations. The system also provides a 25 VRMS speaker-level input to allow power booster operation.An additional non-supervised audio input provided this lowest- priority input can be used for paging or background music as application needs dictate.A highly efficient Class D 100-Watt digital audio power amplifier drives four selectable power-limited speaker circuits in the standard configuration.All speaker circuits are continuously supervised even while activated. Each speaker can be configured for Class A or B wiring without loss of speaker circuits. Amplifier output voltage is 25 VRMS standard. An optional transformer can be configured for 70 VRMS output for longer speaker runs with low signal loss.An audio power boost option is also available for additional output power in multiples of 100 Watts.The ZT-MNS-100BAS provides simple field programming of a variety of its features. These can be as simple as its response to contact closure inputs or to the setting of internal SIP switch banks.Key Features100 Watt highly efficient Class D digital audio Amplifier4 Speaker Circuits Class A or B wiringReverse polarity supervised FACP-Sounder Circuit primary inputSupervised dry contact primary activation input2 Standard messages preloaded ready to goPrioritise contact closure activation inputsRemote microphone inputAux audio inputs for paging background music and Remote system control

GBP 2793.77
1

Zeta SCM-DL64 Smart Datalog Alarm Manager Software for 1 - 64 Panels

Zeta SCM-DL32 Smart Datalog Alarm Manager Software for 1 - 32 Panels

Zeta SCM-DL8 Smart Datalog Alarm Manager Software for 1 - 8 Panels

Zeta SCM-DL16 Smart Datalog Alarm Manager Software for 1 - 16 Panels

Zeta PP-517 Premier Power Pack EN54-4 Power Supply 5.0 Amp With Space For Up To 2 X 17Ah 12Vdc SLA Batteries

Zeta PP-212 Premier Power Pack EN54-4 Power Supply 2.0 Amp With Space For Up To 2 X 12Ah 12Vdc SLA Batteries

Zeta ZAIO230STD Mains Switching IO Unit

Zeta ZAIO230MARK1 InputOutput Module Mains Voltage Rated

Zeta ZAIO230 Mains IO 1 Channel InputOutput Module - Fyreye MKII Protocol

Zeta ZAIO230 Mains IO 1 Channel InputOutput Module - Fyreye MKII Protocol

Zeta ZAIO230 Mains IO 1 Channel InputOutput Module - Fyreye MKII Protocol -8A 230V ACThe Mains IO Modules are fully monitored loop powered devices which permit the interfacing of third-party equipment with the Fire Alarm Control panel using normally open dry contact connections.The connection to the input is monitored for fault open or short circuit and Alarm conditions.The interface is used to monitor the contacts of an external system which must be interfaced to the Fire Alarm System for example a Flow Switch in a sprinkler system to indicate if the sprinklers have been activated or extinguishant level monitoring in Gas Extinguishing systems etc.Module is provided with a loop short-circuit isolator and with a voltage free single pole change over mains rated output. The output relay is always powered directly from the detection loop. It is not required to use an external 24V DC power supply. Relay operation is confirmed by an on-board red LED.An 8-way D.I.L switch is provided to configure the modules address. This value can be set in the range 1 to 125.The following programmable functions are available Input Activation Mode Delayed Input Alarm Activation Output Delayed Activation.The Simplicity CO 8 range is designed to detect monitor CO concentrations in places such as warehouses car parks tunnels and enclosed buildings where forklifts cars and delivery trucks can produce deadly amounts of carbon monoxide in high traffic areas Carbon Monoxide can accumulate in these areas and can be a serious safety and health concern.Key FeaturesFast Activation ResponseLoop PoweredFive Status LEDs providedLow Power ConsumptionModule features an integral short-circuit loop isolatorSingle mains rated relay contact

GBP 57.38
1

Zeta SMART63212Z Smart Connect Multiloop 12 Zone Panel With Zonal LED

Zeta SMART106430Z Smart Connect Multiloop 30 Zone Panel with Zonal LED

Zeta SMART63218Z Smart Connect Multiloop 18 Zone Panel with Zonal LED

Zeta SMART106424Z Smart Connect Multiloop 24 Zone Panel with Zonal LED