26 results (0,17055 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Zeta 10-070 Survey Kit

Zeta 10-070 Survey Kit

Zeta 10-070 Survey KitThe Wi-Fyre Wireless Survey Head is to be used when conducting a wireless survey prior to installation. A Wi-Fyre survey is carried out using a standard LCD Transponder together with a purpose designed Wireless Survey-head. For consistency the test-head has an identical performance to that of a standard wireless detector base and is fitted with an 8-way colour coded rotary LED array to indicate the signal strength received at the Transponder fromIntegral Survey ModeOur goal from the beginning was to create a user-friendly experience for both the engineer and end-user. Simple configuration and maintenance through a highly intuitive menu structure allows Wi-Fyre to perform tasks such as adding removing or viewing the status of a wireless device in a minimal amount of button presses.A Wi-Fyre survey is carried out using a standard LCD Transponder together with a purpose designed Wireless Survey-head. For consistency the test-head has an identical performance to that of a standard wireless detector base and is fitted with an 8-way colour coded rotary LED array to indicate the signal strength received at the Transponder from its current location.Whether you are the installer or specifier a site survey is essential prior to installation. This will not only speed up the time taken to complete installation and commissioning but will ensure that a reliable trouble-free system is in place afterwards without any surprises.Key FeaturesBattery Operated Wi-Fyre Universal Wireless Transponder with LCD Indication ControlWi-Fyre Wireless Survey Test Head with Small Extension PoleWi-Fyre Wireless Survey GuideWi-Fyre Site Survey FormWi-Fyre Product Guide

GBP 968.76
1

Zeta IN4 Infinity 4 Zone Conventional Fire Alarm Panel

Zeta IN2 Infinity 2 Zone Conventional Fire Alarm Panel

Zeta ID2-MCP Infinity ID2 Indoor Manual Call Point cw Surf Backbox Bezel and Cover

Zeta IN6 Infinity 6 Zone Conventional Fire Alarm Panel

Zeta IN8 Infinity 8 Zone Conventional Fire Alarm Panel

Zeta IN1 Infinity 1 Zone Conventional Fire Alarm Panel

Zeta ZT-MAINS-H5 Mains Heat Detector with 9V Battery Back-Up

Zeta ZT-MAINS-5 Mains Photoelectric Smoke Alarm with 9V Battery Back-Up

Zeta GS-220.BC.V.ZETA.404A.2000 R-404A Refrigerant Gas Detector

Zeta GS-220.BC.V.ZETA.410A.2000 R-410A Refrigerant Gas Detector

Zeta GS-220.BC.V.ZETA.290.2000 R-290 Refrigerant Gas Detector

Zeta GS-220.BC.V.ZETA.134A.2000 R-134A Refrigerant Gas Detector

Zeta GS-220.BC.V.ZETA.407C.2000 R-407C Refrigerant Gas Detector

Zeta ZIS-OSD Intrinsically Safe Optical Smoke Detector

Zeta SP-REP Simplicity Plus Addressable Full Function Repeater

Zeta ZAIO230 Mains IO 1 Channel InputOutput Module - Fyreye MKII Protocol

Zeta ZAIO230 Mains IO 1 Channel InputOutput Module - Fyreye MKII Protocol

Zeta ZAIO230 Mains IO 1 Channel InputOutput Module - Fyreye MKII Protocol -8A 230V ACThe Mains IO Modules are fully monitored loop powered devices which permit the interfacing of third-party equipment with the Fire Alarm Control panel using normally open dry contact connections.The connection to the input is monitored for fault open or short circuit and Alarm conditions.The interface is used to monitor the contacts of an external system which must be interfaced to the Fire Alarm System for example a Flow Switch in a sprinkler system to indicate if the sprinklers have been activated or extinguishant level monitoring in Gas Extinguishing systems etc.Module is provided with a loop short-circuit isolator and with a voltage free single pole change over mains rated output. The output relay is always powered directly from the detection loop. It is not required to use an external 24V DC power supply. Relay operation is confirmed by an on-board red LED.An 8-way D.I.L switch is provided to configure the modules address. This value can be set in the range 1 to 125.The following programmable functions are available Input Activation Mode Delayed Input Alarm Activation Output Delayed Activation.The Simplicity CO 8 range is designed to detect monitor CO concentrations in places such as warehouses car parks tunnels and enclosed buildings where forklifts cars and delivery trucks can produce deadly amounts of carbon monoxide in high traffic areas Carbon Monoxide can accumulate in these areas and can be a serious safety and health concern.Key FeaturesFast Activation ResponseLoop PoweredFive Status LEDs providedLow Power ConsumptionModule features an integral short-circuit loop isolatorSingle mains rated relay contact

GBP 57.38
1

Zeta ID28 Infinity ID2 Intelligent 2 Wire 8 Zone Fire Panel

Zeta ID28 Infinity ID2 Intelligent 2 Wire 8 Zone Fire Panel

Zeta ID28 Infinity ID2 Intelligent 2 Wire 8 Zone Fire PanelZeta Alarm Systems is proud to introduce the most advanced 2 wire system on the market. We can now provide a system that gives all of the benefits associated with a 2 Wire installation less cable quicker installation cost savings on labourproduct and has the facility to I.D. the devices.The system is built on the proven communication protocol developed by Zeta Alarm Systems and shares the same platform as our largest most powerful system.The ID2 can be used for new installations as a retrofit for any conventional system or as a replacement for existing 2 wire systems when the extra features are deemed to be desirablenecessary. This is possible because the ID2 devices sit on radial circuits thus making it easy to upgrade a system with the facility to I.D. devices without the need to re-wire.Key Features The system meets the full requirements of BSEN5839 parts 1 and 6.The control panel has been designed to meet EN54 parts 2 and 4.Each device can be uniquely identified by the panelDevice Count VerificationAlarm Verification2048 Event HistoryID2 Smartphone App available for iOS and AndroidCable Break protectionCable Short Circuit ProtectionOne man walk test facilityAuto configuration for easy set upSafer than a traditional 2 wireconventional system as it tells you exactly where the event is - no time wasted searching a whole zonePlease note This product requires 2 xNP7-12 Batteries.

GBP 392.72
1

Zeta ID28M Infinity ID2 Intelligent 2 Wire 8 Zone Fire Panel in Metal Enclosure

Zeta ID28M Infinity ID2 Intelligent 2 Wire 8 Zone Fire Panel in Metal Enclosure

Zeta ID28M Infinity ID2 Intelligent 2 Wire 8 Zone Fire Panel in Metal EnclosureZeta Alarm Systems is proud to introduce the most advanced 2 wire system on the market. We can now provide a system that gives all of the benefits associated with a 2 Wire installation less cable quicker installation cost savings on labourproduct and has the facility to I.D. the devices.The system is built on the proven communication protocol developed by Zeta Alarm Systems and shares the same platform as our largest most powerful system.The ID2 can be used for new installations as a retrofit for any conventional system or as a replacement for existing 2 wire systems when the extra features are deemed to be desirablenecessary. This is possible because the ID2 devices sit on radial circuits thus making it easy to upgrade a system with the facility to I.D. devices without the need to re-wire.Key FeaturesThe system meets the full requirements of BSEN5839 parts 1 and 6.The control panel has been designed to meet EN54 parts 2 and 4.Each device can be uniquely identified by the panelDevice Count VerificationAlarm Verification2048 Event HistoryID2 Smartphone App available for iOS and AndroidCable Break protectionCable Short Circuit ProtectionOne man walk test facilityAuto configuration for easy set upSafer than a traditional 2 wireconventional system as it tells you exactly where the event is - no time wasted searching a whole zone

GBP 642.60
1

Zeta CO800G Fyreye Addressable Carbon Monoxide Detector IP54

Zeta CO800G Fyreye Addressable Carbon Monoxide Detector IP54

Zeta CO800G Fyreye Addressable Carbon Monoxide Detector IP54The CO800G is an analogue addressable Carbon Monoxide detector specifically designed for use with the Simplicity CO addressable carbon monoxide monitoring ventilation panel.The detector uses an electro-chemical sensor with the detection range of 0 to 600 ppm of carbon monoxide.The detectors address is set via a binary dipswitch on the rear of the detector. The optimum mounting height for this detector is between 1.5 2m from the floor.How is CO GeneratedCarbon Monoxide is a by-product of combustion. Any fuel burning appliance vehicle tool or other device has the potential to produce dangerous levels of Carbon Monoxide.The Simplicity CO 8 system is designed to detect monitor CO concentrations in places such as warehouses car parks tunnels and enclosed buildings where forklifts cars and delivery trucks can produce deadly amounts of carbon monoxide in high traffic areas Carbon Monoxide can accumulate in these areas and can be a serious safety and health concern.What is the Simplicity COThe Simplicity CO system was designed to be simple to use addressable carbon monoxide detection and ventilation system capable of detecting low concentrations of CO and automatically starting the buildings ventilation fans. Its features includeTrue analogue addressable systemEconomical 2 wire installationCan view the PPM reading of every detectorEach detector can be given a 20-character label to ease device identification optional.Loop of 126 devices divided into 8 zonesContinuously displays the maximum reading in each zoneOption for 2 ventilation relays per zone for systems with 2 speed fansZonal or common ventilation optionsEasy to use ventilation level selection Battery backup enables the system to give an alarm warning in the case of mains power failureSystem programming is determined by detector relay address settingsSuitable for small and large installationsDesigned Manufactured in the UK

GBP 87.97
1

Zeta SP-64M Simplicity Plus 1 Loop 64 Devices Addressable Fire Panel

Zeta SP-64M Simplicity Plus 1 Loop 64 Devices Addressable Fire Panel

Zeta SP-64M Simplicity Plus 1 Loop 64 Devices Addressable Fire PanelThe Simplicity Plus is the ideal introduction to the world of addressable fire alarm panels. As its name suggests it has been designed with ease of use in mind using pre-programmed values for its programming options. The installer simply needs to configure the loop and enter text labels via the built-in keypad optional.The Simplicity Plus has user definable zones option for zonal or common alarm operation options for IO operation alarm verification and user selectable languages. It can be connected to an RS232 desktop printer for real time event log printing Epson LQ300 recommended and it can also drive a serial repeater model SPREP Part No. 37-179.Alarm VerificationTo help prevent false alarm causing a full evacuation any smoke detector can be set to alarm verification mode with a time delay of between 30 seconds and 4 minutes. Should any of these detectors go into alarm then only the detectors LEDs and soundflasher base if connected will activate. Should the alarm not be cleared with this time delay then a common alarm will occur.Zonal AddressingAll devices are assigned to a specific zone based on their address. This removes a programming step and helps to streamline the commissioning process.Key FeaturesOne or Two loop addressable fire alarm panel 64 126 or 252 device capacityCertified to EN54 parts 2 4User definable zonesOption for zonal or common alarm operationOptions for IO operationAlarm verification help prevent false alarmsUser selectable languagesSet of changeover relay contacts for fault conditionSet of changeover relay contacts for fire condition2048 event log fire faultZone or device disablementOne-man test modePlug play no need for any special tools or laptop for commissioningFully integrated keypadAll associated devices are loop poweredSupply Voltage 230V AC - 10System Voltage 24V DC NominalEnclosure Size 375W x 335H x 128D

GBP 661.50
1

Zeta SP-126M Simplicity Plus 126 Addressable Fire Alarm Panel - 1 Loop 126 Devices

Zeta SP-126M Simplicity Plus 126 Addressable Fire Alarm Panel - 1 Loop 126 Devices

Zeta SP-126M Simplicity Plus 126 Analogue Addressable Fire Alarm Panel - 1 Loop 126 DevicesMetal EnclosureThe Simplicity Plus is the ideal introduction to the world of addressable fire alarm panels.As its name suggests it has been designed with ease of use in mind using pre-programmed values for its programming options. The installer simply needs to configure the loop and enter text labels via the built-in keypad optional.The Simplicity Plus has user definable zones option for zonal or common alarm operation options for IO operation alarm verification and user selectable languages.It can be connected to an RS232 desktop printer for real time event log printing Epson LQ300 recommended and it can also drive a serial repeater model SPREP Part No. 37-179.Alarm VerificationTo help prevent false alarm causing a full evacuation any smoke detector can be set to alarm verification mode with a time delay of between 30 seconds and 4 minutes. Should any of these detectors go into alarm then only the detectors LEDs and soundflasher base if connected will activate. Should the alarm not be cleared with this time delay then a common alarm will occur.Zonal AddressingAll devices are assigned to a specific zone based on their address. This removes a programming step and helps to streamline the commissioning process.Key Features1 Loop 126 DevicesCertified to EN54 parts 2 4User definable zonesOption for zonal or common alarm operationOptions for IO operationAlarm verification help prevent false alarmsUser selectable languagesSet of changeover relay contacts for fault conditionSet of changeover relay contacts for fire condition2048 event log fire faultZone or device disablementOne-man test modePlug play no need for any special tools or laptop for commissioningFully integrated keypadAll associated devices are loop poweredSupply Voltage 230V AC - 10System Voltage 24V DC NominalOperating Temperature -0C to 50CEnclosure Size 375mm x 335mm x 125mm

GBP 725.08
1

Zeta SP-252M Simplicity Plus 252 Addressable Fire Alarm Panel - 2 Loop 252 Devices

Zeta SP-252M Simplicity Plus 252 Addressable Fire Alarm Panel - 2 Loop 252 Devices

Zeta SP-252M Simplicity Plus 252 Analogue Addressable Fire Alarm Panel - 2 Loop 252 DevicesMetal EnclosureThe Simplicity Plus is the ideal introduction to the world of addressable fire alarm panels.As its name suggests it has been designed with ease of use in mind using pre-programmed values for its programming options. The installer simply needs to configure the loop and enter text labels via the built-in keypad optional.The Simplicity Plus has user definable zones option for zonal or common alarm operation options for IO operation alarm verification and user selectable languages.It can be connected to an RS232 desktop printer for real time event log printing Epson LQ300 recommended and it can also drive a serial repeater model SPREP Part No. 37-179.Alarm VerificationTo help prevent false alarm causing a full evacuation any smoke detector can be set to alarm verification mode with a time delay of between 30 seconds and 4 minutes. Should any of these detectors go into alarm then only the detectors LEDs and soundflasher base if connected will activate. Should the alarm not be cleared with this time delay then a common alarm will occur.Zonal AddressingAll devices are assigned to a specific zone based on their address. This removes a programming step and helps to streamline the commissioning process.Key Features2 Loop 252 DevicesCertified to EN54 parts 2 4User definable zonesOption for zonal or common alarm operationOptions for IO operationAlarm verification help prevent false alarmsUser selectable languagesSet of changeover relay contacts for fault conditionSet of changeover relay contacts for fire condition2048 event log fire faultZone or device disablementOne-man test modePlug play no need for any special tools or laptop for commissioningFully integrated keypadAll associated devices are loop poweredSupply Voltage 230V AC - 10System Voltage 24V DC NominalEnclosure Size 375mm x 335mm x 125mm

GBP 790.37
1

Zeta S64COM Simplicity CO 64 Addressable CO Panel - 4 Zone 64 Device in Metal Enclosure

Zeta S64COM Simplicity CO 64 Addressable CO Panel - 4 Zone 64 Device in Metal Enclosure

Zeta S64COM Simplicity CO 64 Addressable CO Panel - 4 Zone 64 Device in Metal EnclosureThe Simplicity CO system is a self-conditioned controller with a capacity to handle up to 110 CO monitors which are divided to 8 monitoring zones.Each Zone will permanently display on the Liquid Crystal Display LCD the highest concentration of CO in that zone in PPM Particles Per Million. This monitored value is updated every 10 seconds. The system will allow up to 2 interface modules ZIOUI-230 which are programmed to initiate a signal to Ventilation equipment to operate at pre-determined levels of concentration. Should the CO concentration keep rising while the Ventilation is still on an alarm is raised at a pre-determined level.The Simplicity CO system is ideal forUnderground car parking facilitiesWarehouses where non-electric fork lift vehicles are usedTunnelsFactoriesBoiler Rooms etcKey FeaturesAlarm Output 2 x 150mA 24 VdcPanel Size mm 370W x 311H x 113DSpace for Batteries Up to 2 x 7.0 AH SLA BatteriesHow is CO GeneratedCarbon Monoxide is a by-product of combustion. Any fuel burning appliance vehicle tool or other device has the potential to produce dangerous levels of Carbon Monoxide.The Simplicity CO 8 system is designed to detect monitor CO concentrations in places such as warehouses car parks tunnels and enclosed buildings where forklifts cars and delivery trucks can produce deadly amounts of carbon monoxide in high traffic areas Carbon Monoxide can accumulate in these areas and can be a serious safety and health concern.What is the Simplicity COThe Simplicity CO system was designed to be simple to use addressable carbon monoxide detection and ventilation system capable of detecting low concentrations of CO and automatically starting the buildings ventilation fans. Its features includeTrue analogue addressable systemEconomical 2 wire installationCan view the PPM reading of every detectorEach detector can be given a 20-character label to ease device identification optional.Loop of 126 devices divided into 8 zonesContinuously displays the maximum reading in each zoneOption for 2 ventilation relays per zone for systems with 2 speed fansZonal or common ventilation optionsEasy to use ventilation level selection Battery backup enables the system to give an alarm warning in the case of mains power failureSystem programming is determined by detector relay address settingsSuitable for small and large installationsDesigned Manufactured in the UKMeets latest low voltage directive CE marked

GBP 681.78
1

Zeta S32CO Simplicity CO 32 Addressable CO Panel - 2 Zone 32 Devices

Zeta S32CO Simplicity CO 32 Addressable CO Panel - 2 Zone 32 Devices

Zeta S32CO Simplicity CO 32 Addressable CO Panel - 2 Zone 32 DevicesThe Simplicity CO system is a self-conditioned controller with a capacity to handle up to 110 CO monitors which are divided to 8 monitoring zones.Each Zone will permanently display on the Liquid Crystal Display LCD the highest concentration of CO in that zone in PPM Particles Per Million. This monitored value is updated every 10 seconds. The system will allow up to 2 interface modules ZIOUI-230 which are programmed to initiate a signal to Ventilation equipment to operate at pre-determined levels of concentration. Should the CO concentration keep rising while the Ventilation is still on an alarm is raised at a pre-determined level.The Simplicity CO system is ideal forUnderground car parking facilitiesWarehouses where non-electric fork lift vehicles are usedTunnelsFactoriesBoiler Rooms etcKey FeaturesAlarm Output 2 x 150mA 24 VdcPanel Size mm 370W x 311H x 113DSpace for Batteries Up to 2 x 7.0 AH SLA BatteriesWeight 4KgHow is CO GeneratedCarbon Monoxide is a by-product of combustion. Any fuel burning appliance vehicle tool or other device has the potential to produce dangerous levels of Carbon Monoxide.The Simplicity CO 8 system is designed to detect monitor CO concentrations in places such as warehouses car parks tunnels and enclosed buildings where forklifts cars and delivery trucks can produce deadly amounts of carbon monoxide in high traffic areas Carbon Monoxide can accumulate in these areas and can be a serious safety and health concern.What is the Simplicity COThe Simplicity CO system was designed to be simple to use addressable carbon monoxide detection and ventilation system capable of detecting low concentrations of CO and automatically starting the buildings ventilation fans. Its features includeTrue analogue addressable systemEconomical 2 wire installationCan view the PPM reading of every detectorEach detector can be given a 20-character label to ease device identification optional.Loop of 126 devices divided into 8 zonesContinuously displays the maximum reading in each zoneOption for 2 ventilation relays per zone for systems with 2 speed fansZonal or common ventilation optionsEasy to use ventilation level selection Battery backup enables the system to give an alarm warning in the case of mains power failureSystem programming is determined by detector relay address settingsSuitable for small and large installationsDesigned Manufactured in the UKMeets latest low voltage directive CE marked

GBP 515.45
1