Ziton ZP2-AF1-S-99 Addressable Fire Panel Small Cabinet 1 Loop English UK

Ziton ZP2-AF1-S-99 Addressable Fire Panel Small Cabinet 1 Loop English UK

Ziton ZP2-AF1-S-99 Addressable Fire Panel Small Cabinet 1 Loop English UKThe new ZP2-AF1-S-99 series life safety control systems bring the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. Based on ZP2 series learned experience and with complete backwards compatibility the new ZP2-AF1-S-99 features an attractive contemporary design that fits with any dcor. With improved robustness manufactured in metal special plastics and easy electronics removal it allows painting in any colour. The main controls are easily located using an improved and robust jog dial.With high power loop addressable detection a full line of easily configured option cards and modules as well as USB and Ethernet connectivity these quick-to configure systems offer versatility that benefits building owners and life safety system installers alike.The PanelThe fire panels supplied in local language with user interface with 1 loop that supports up to 254 devices 127 addresses in 512 zones have standard 2 supervised sounderfire-routing outputs which can be used as freely programmable outputs as well. In addition 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available.OptionsThe panel supports one network board to create a maximum of 64 nodes 256 loops network of fire panels and fire panel repeaters including conventional fire panels and fire repeater panels up to a maximum of 64 conventional zones. Last but not least in case separate zone indications are required a 20 or a 40 zone firefault LED indicator board can be mounted in the panel or repeater with ample space for custom text.Compatible with existing loop devices and network compatible with existing panels repeaters existing and new and conventional panels.EN54 compliant graphical LCD with icons and up to 256 zonesImproved Jog Dial with 4 soft buttons for simple and intuitive user controlAesthetic pleasing design with robust painted steel doorEasy removable door and chassis for quick and clean installationAll pluggable connectorsAuxiliary 24 VDC supply output with reset support3 USB ports with memory stick support and RS232 for printer supportCommunication via UltraSync cloud using EN 54-21 UC240 UltraSync communicatorIntegration in management softwareATS8600 allowing integration with security systems and CMS3 operator level menu structure 20 usernames and passwordsEmail notification for events directly from the panel 4 user accountsHistory log memory for 9999 eventsBackwards compatible supporting site retrofitupgrades expansions replacementCompatible with the Ziton loop powered soundersbeacons and base sounders and Ziton series detectors

GBP 584.87
1

Ziton ZP2-AF1-99 Addressable Fire Panel - 1 Loop - English UK

Ziton ZP2-AF1-99 Addressable Fire Panel - 1 Loop - English UK

Ziton ZP2-AF1-99 Addressable Fire Panel - 1 Loop - English UKThe new ZP2-A series life safety control systems bring the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. Based on ZP2 series learned experience and with complete backwards compatibility the new ZP2-A features an attractive contemporary design that fits with any dcor. With improved robustness manufactured in metal special plastics and easy electronics removal it allows painting in any colour. The main controls are easily located using an improved and robust jog dial.With high power loop addressable detection a full line of easily configured option cards and modules as well as USB and Ethernet connectivity these quick-to configure systems offer versatility that benefits building owners and life safety system installers alike.Key Features1 High Power Loop with 800 mA per loopUp to 512 zones and 300 output groupsUp to 40 LED Zone indicators for Fire and Fault with ample text spaceAuto configuration setup wizards and default regional setup modesEthernet port with TCPIP for remote diagnostics maintenance and programmingEN54 compliant graphical LCD with icons and up to 256 zonesImproved Jog Dial with 4 soft buttons for simple and intuitive user controlAesthetic pleasing design with robust painted steel doorEasy removable door and chassis for quick and clean installationAll pluggable connectorsAuxiliary 24 VDC supply output with reset support3 USB ports with memory stick support and RS232 for printer supportCommunication via UltraSync cloud using EN 54-21 UC240 UltraSync communicatorIntegration in management software ATS8600 allowing integration with security systems and CMS3 operator level menu structure 20 usernames and passwordsEmail notification for events directly from the panel 4 user accountsHistory log memory for 9999 eventsBackwards compatible supporting site retrofitupgrades expansions replacementCompatible with the Ziton loop powered soundersbeacons and base sounders and Ziton series detectors

GBP 584.87
1

Ziton ZP755WV-2R Addressable Weatherproof Sounder Beacon

Ziton ZP755WV-2R Addressable Weatherproof Sounder Beacon

Ziton ZP755WV-2R Addressable Weatherproof Sounder BeaconThe ZP755WV-2R is an addressable weatherproof sounderbeacon designed for use on ZP addressable fire detection and alarm systems. The device is developed for outdoor applications.Installed directly onto and powered by the ZP wiring loop the ZP755 range enables the system designer to offer a complete ZP addressable system on a single pair of wires. Installation costs are greatly reduced whilst system integrity sounder options and programmed alarm organisation are significantly increased.High efficiency low energy designHigh efficiency acoustic design low energy sound gun transducer and low current Light Emitting Diode LED visual element enables up to 24 sounder beacons to be connected to a one kilometer loop of 1.5 mm cable with a wiring run of 50 m to the first device.In systems where loop lengths or current requirements are excessive ZP755WV-2R sounder beacons can be powered directly from an external power supply.Range of sound outputsContinuous intermittent and two-tone audible outputs are available from which any combination can be chosen to provide alert and evacuate two stage alarms. All sound types comply with most local codes for example BS 5839 Part 1 recommended frequencies in the UK. The ZP755WV-2R produces a sound output of 95 dBA measured at 1 m. A volume control is included for areas where a reduced sound output is required.Molded in high impact red thermoplastic the sounder beacon features a red lens.Key FeaturesWeatherproofSounder with visual indicator in a single unitHigh sound outputLow current LED based visual elementHigh efficiency sound gun transducerUp to 30 devices powered directly from loop wiringEN543 approved and CPR certified

GBP 163.42
1

Ziton Anti-Condensation Heater FD310 Series FD-CH3

Ziton AAI-0100 Interposing Cable

Ziton AAI-0100 Interposing Cable

Ziton AAI-0100 Interposing CableThe AAI-0100 is a non-detecting interconnection cable for use with linear heat detection cable and is supplied in 100m lengths. It is used in conjunction with analogue or digital linear heat detection cable where the interface unit and the protected area is not at the same location thus this cable is connecting the interface unit with the detection cable which is located in the protected area.InstallationThe ACA-JBW junction box must be used for the connection between the linear heat detection cable and the non-detecting cable. This is crucial to ensure that environmental conditions and materials dont affect the connection which in turn will affect the detection capability of the system.ApplicationIn some applications due to site requirements or layout it might not be possible to install the linear heat detection interface in or next to the protected area. As a result it will be installed at a different location with the requirement to connected the linear heat detection cable in the protected area with the remote interface unit.The non-detecting interconnect cable is specifically designed for this scenario. It ensures that detection is only active in the protected area and not in the area in between the interface unit and the protected area. Additionally it offers a cost-effective alternative to using more expensive linear hear detection cable.Key FeaturesNo detection propertiesFor use with analogue and digital linear heat detection systemsCost-effective

GBP 301.19
1

Ziton Anti-Condensation Heater FD800 Series FD-CH2

Ziton 1-B6782-170 Retractable Cable 30m

Ziton ZP755-COV-P Cover For All ZP755B Base Sounders With No Detector - Polar White

Ziton ZR4-RL Wireless Remote Indicator For Use On Ziton 868MHz Wireless Fire Alarm Systems

Ziton ZR4-RL Wireless Remote Indicator For Use On Ziton 868MHz Wireless Fire Alarm Systems

Ziton ZR4-RL Wireless Remote Indicator For Use On Ziton 868MHz Wireless Fire Alarm SystemsThe ZR4-RL Wireless Remote Indicator is a wireless remote indicator for use on Ziton 868MHz wireless fire alarm systems. The siting of field devices in confined or concealed spaces often results in the alarm indicator on the device moulding becoming obscured or hidden.In order to show the state of an alarm clearly when installed in areas such as ceiling or floor voids the ZR4-RL Wireless Remote Indicator can be programmed to indicate any alarm in the system and installed in any prominent position.The ZR4-RL has a high intensity red LED indicator positioned centrally on its white round plastic moulding together with the standard house on fire alarm symbol. The unit is designed to fit onto its wireless surface mounting base which also houses the batteries and the receivertransmitter for the wireless interface.An easy to mount first fix base is included where the orientation for wall mounting is clearly indicated allowing the unit to always be installed in the correct orientation when wall mounted.Key FeaturesHigh intensity red LED indicationCompatible with all ZP 868 MHz wireless fire alarm systemsBuilt-in locking mechanism preventing unauthorised removalFully supervised including removal and battery statusFully programmable - may be linked to any single or combination of system alarmsEN5425 Approved

GBP 154.46
1

Ziton Alarmline V Bracket Stainless Steel with Silicon Sleeve

Ziton A2S Weatherproof Heat Detector IP67 57C

Ziton A2S Weatherproof Heat Detector IP67 57C

Ziton A2S Weatherproof Heat Detector IP67 57CThe 6295 from Ziton is an enclosed conventional heat detector - weatherproof IP67.Heat detectors are normally used in rooms where the temperature can be expected to rise rapidly in case of a fire or in places where smoke detectors cannot be used. The 6000 series heat detectors are intended for outdoor or indoor use in high humidity areas.All detectors are latching i.e. they will not be automatically reset if the temperature after the alarm falls below the detectors static response temperature. The detectors LED and a connected remote LED will be lit until the detector is reset via the C.I.E.The 6000 series detectors are conventional fixed temperature heat detectors i.e. they will give an alarm within a response temperature range in accordance with EN54-52000. The sensing element is a heat pick-up shield and a bimetal switch. An LED on the detector not available on the 6298 will light up when the detector activates. All detectors support an output for a remote indicator.All electronic components are mounted in a grey waterproof detector housing and fitted to the supplied connection box. The connection box has three cable inlets. Three compression glands and a silicon gasket for IP67 protection are supplied with the product. All detectors are provided with three pairs of flying leads with female push-on connectors to connect the zone line cables in out and the remote indicator.Key FeaturesFixed temperature alarm levelATEX compliance 6295 and 6296Waterproof IP67

GBP 166.28
1

Ziton BS Weatherproof Heat Detector IP67 72C

GBP 188.52
1

Ziton 6297 CS Weatherproof Heat Detector IP67 87C

Ziton 6297 CS Weatherproof Heat Detector IP67 87C

Ziton 6297 CS Weatherproof Heat Detector IP67 87CHeat detectors are normally used in rooms where the temperature can be expected to rise rapidly in case of a fire or in places where smoke detectors cannot be used. The 6000 series heat detectors are intended for outdoor or indoor use in high humidity areas.All detectors are latching i.e. they will not be automatically reset if the temperature after the alarm falls below the detectors static response temperature. The detectors LED and a connected remote LED will be lit until the detector is reset via the C.I.E.The 6000 series detectors are conventional fixed temperature heat detectors i.e. they will give an alarm within a response temperature range in accordance with EN54-52000. The sensing element is a heat pick-up shield and a bimetal switch. An LED on the detector not available on the 6298 will light up when the detector activates. All detectors support an output for a remote indicator.All electronic components are mounted in a grey waterproof detector housing and fitted to the supplied connection box. The connection box has three cable inlets. Three compression glands and a silicon gasket for IP67 protection are supplied with the product.All detectors are provided with three pairs of flying leads with female push-on connectors to connect the zone line cables in out and the remote indicator.Key FeaturesFixed temperature alarm levelATEX compliance 6295 and 6296Waterproof IP67

GBP 223.27
1

Ziton ZP755-COV-R Cover for Base Sounder

Ziton GBX370 Intrinsically Safe Galvanic Isolator

Ziton Z-RL3 Remote LED Flush Mount with Fire Text 122301

Ziton ES Weatherproof Heat Detector IP67 117C

Ziton ES Weatherproof Heat Detector IP67 117C

Ziton ES Weatherproof Heat Detector IP67 117CHeat detectors are normally used in rooms where the temperature can be expected to rise rapidly in case of a fire or in places where smoke detectors cannot be used. The 6000 series heat detectors are intended for outdoor or indoor use in high humidity areas.Fixed Temperature Alarm LevelThe 6000 series detectors are conventional fixed temperature heat detectors i.e. they will give an alarm within a response temperature range in accordance with EN54-52000. The sensing element is a heat pick-up shield and a bimetal switch. An LED on the detector not available on the 6298 will light up when the detector activates. All detectors support an output for a remote indicator.The following types are available static response temperature class EN54-5 temperature range.6295 57C class A2 S 54 to 70C6296 72C class B S 69 to 85C6297 87C class C S 84 to 100C6298 117C class E S 114 to 130COperationAll detectors are latching i.e. they will not be automatically reset if the temperature after the alarm falls below the detectors static response temperature. The detectors LED and a connected remote LED will be lit until the detector is reset via the C.I.E.InstallationAll electronic componets are mounted in a grey waterproof detector housing and fitted to the supplied connection box. The connection box has three cable inlets. Three compression glands and a silicon gasket for IP67 protection are supplied with the product.All detectors are provided with three pairs of flying leads with female push-on connectors to connect the zone line cables in out and the remote indicator.Key FeaturesFixed temperature alarm levelWaterproof IP67

GBP 234.43
1

Ziton Tie Wrap PA66 110C 230F

Ziton DM700K-N Red Key Switch Manual Call Point