351 results (0,13952 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Ziton 2010-2-DACT Digital Alarm Communicator Transmitter

Ziton 2010-2-PAK-RMMB Modbus PAK

Ziton ZP1-F4-MB ZP1 Main Board - 4 Zone Replacement Main PCB for the ZP1-F4-xx

Ziton ZP1-F2-MB ZP1 Main Board - 2 Zone Replacement Main PCB for the ZP1-F2-xx

Ziton ZP1-F2-MB ZP1 Main Board - 2 Zone Replacement Main PCB for the ZP1-F2-xx

Ziton ZP1-F2-MB ZP1 Main Board - 2 Zone Replacement Main PCB for the ZP1-F2-xxThe ZP1-F2-MB is a ZP1 Main Board - 2 Zone Replcement Main PCB designed for theZP1-F2 range.ZP1 fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mid-sized conventional applications. They feature an attractive contemporary design that fits with any decor. The gently curved door front offers a distinctive flair. Operator controls are inset in a striking blue lexan.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.The PanelThe ZP1-F2 is a conventional fire alarm control panel. It is supplied in local language with 2 zones that support up to 32 devices per zone as well as up to 2 supervised relay outputs dedicated to sounder control. In addition 2 conventional relay outputs dedicated to common fire and fault conditions as well as two user configurable inputs for monitoring and control are available.OptionsThe panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 8 additional outputs.Approvals ComplianceThe product line carries the following accreditationsRoHS compliantWEEE compliantNEN2535 NBNS21-100 and BS5839-1 compliantCPD certifiedEN542 EN544 and CE approvedType class conditions 3K5 of IEC 60721-3-3Key FeaturesModern elegant designEasy removable parts for quick and clean installationDefault regional setup modesNormal head-out intrinsically safe zone supportSupervised alarm notification outputsEN54 compliant potential free fire fault relaysClass change daynight remote reset facilitiesAuxiliary 24VDC supply output with reset supportDefault support for special functions such as - EN54 compliant user access levels - mixed zones - full front panel diagnostics - one-man walk testAuxiliary standard supervised relay output boardsNetworkable up to 64 zones

GBP 180.13
1

Ziton A50E-2 Addressable Line Relay Module

Ziton A50E-2 Addressable Line Relay Module

Ziton A50E-2 Addressable Line Relay ModuleThe A50E-2 is an addressable relay providing single pole volt free change over contacts. The unit is intended for installation within the equipment to be switched thereby offering savings in installation costs when compared to long auxiliary circuit wiring runs out from the control panel. Complying with EN54 Part 18 the relay can be located anywhere on the two core ZP loop and is designed for power up or shut down of building services for example air conditioning plant in fire conditions. The unit is ideal for the control of associated system equipment such as door release circuits or the emergency shutdown of high risk services for instance gas or oil supply valves in boiler rooms.The relay can be programmed to be activated by any single device groups of devices or all system devices. All types of system input signals can be arranged to operate the A50E-2 which can include control panel indicators zonal outputs callpoints or sensors. Housed in a low profile double width moulding the interface is designed to clip directly onto a standard DIN rail fixing or be installed in a SMB-DIN100 box one unit capacity or a SMB-DIN200 box two unit capacity.A red LED indicator positioned on the front moulding flashes when the interface has operated providing clear identification of the input signal source. Installed as part of an analogue addressable system up to 127 line devices sensors callpoints or interface units can be connected to each of the control panel loops. All loop devices incorporate switch settings enabling them to be assigned a unique address which is polled by the panel every two seconds.Key FeaturesAddressable interface unitComplies with EN54 Part18Low profileDIN rail mountedLoop wired - adjacent to equipment to be switchedOperated from any combination of input addressesVolt free change over contacts

GBP 56.08
1

Ziton ZP3AB-NLM3 Class-A Network Loop Module

Ziton ZP3AB-NLM3 Class-A Network Loop Module

Ziton ZP3AB-NLM3 Class-A Network Loop ModuleThe ZP3AB-NLM network loop module enables individual ZP3 control panels to be connected in a peer to peer secure loop network. If there is an open or short circuit present on the network wiring the NLMs determine where the fault lies isolate the faulty section of wiring and maintain full loop integrity.Total cable length throughout the network can be up to a maximum of two kilometres and may be extended by setting designated NLM modules as booster units contact Ziton technical support department for full details. Communication between loop modules operates by RS485 protocol over screened twisted pair wiring.Unique address on the network loopZP3AB-NLM3 modules connect to ZP3 control panels via a ZP3AB-NET1 card and are designed to fit onto an auxiliary chassis inside each control panel or auxiliary equipment cabinet. Each ZP3 control panel is connected to the loop network through an ZP3AB-NLM3 module. All modules incorporate switch settings enabling them to be assigned a unique loop address. An output fault signal is provided by a volt free changeover relay with contacts rated at 1A at 230VDC30VAC.Diagnostic and system indicationIn each network loop one module must be set to address 1 and designated as the master. This device manages the healing sequence and monitors loop integrity. All other modules are connected to the network loop in slave mode.In slave mode modules can operate in multiple modesBoost - serving as an interconnection between panels at distances over 1000 metresHealing establishing the condition of the loop and isolating sections if necessaryRecovered normal condition after a section isolationDiagnostic system interrogation to establish the location of a break in the loop wiringIn addition to indications of data being transmitted and received from each port LED indicators are also provided for System OK Loop Fault Loop Open and Data Error.Key FeaturesProvides a secure loop networkEnhanced LED diagnosticsBoost mode for long cable runsPropagation time periods for third party equipment operationCommunications screen isolation between input and output channels

GBP 277.06
1

Ziton ZP3AB-NET1 Network Board Optional Facility Card

Ziton ZP3AB-NET1 Network Board Optional Facility Card

Ziton ZP3AB-NET1 Network Board Optional Facility CardThe ZP3AB-NET1 enables ZP3 control panels to be connected together to form networks. The interface card is attached directly onto the ZP3 main control board inside the panel enclosure. Up to 64 standalone control panels can be linked to form the ZP network allowing the integration of over 32 000 system devices.Networks can be designed as peer to peer systems where all control panels are connected to form a single coordinated fire detection and alarm system. Each panel controls its own devices and displays its own system information but is capable of cross panel cause and effect operation. The ZP3AB-NET1 network board also enables hierarchical networks to be easily configured where one or more control panels can be assigned as masters displaying complete system status.RS485 protocolCommunication between ZP3 fire alarm panels operates by RS485 protocol over twisted screened pair wiring. Total cable length throughout the network can be up to a maximum of 2 kilometres. On larger sites where wiring runs to remote systems may exceed this maximum cable lengths can be extended by the addition of RS485 booster units or optical fibre connection.Designed to provide flexible system configuration system wiring can be daisy chained or teed off with spurs. Network connections are in data quality cable with a minimum core diametre of 0.5 mm. Jumper terminating switches are provided on all network interface boards which are set at the system commissioning stage.Cost effective optionsThe ZP3AB-NET1 network board is part of the range of optional facility boards which can be added cost effectively to any ZP3 control panel in order to provide extra facilities that may not be a requirement of every system.Housed within the ZP3 panel options can simply be added during panel manufacture to meet particular specifications or subsequently fitted on site should a particular requirement become necessary during the life of the system.Key FeaturesUp to 64 panel networkingHoused inside main panel enclosureComplete cross panel communicationsInter panel cause and effect operation

GBP 277.07
1

Ziton A51E-1 Addressable Mains Relay Module

Ziton A51E-1 Addressable Mains Relay Module

Ziton A51E-1 Addressable Mains Relay ModuleThe A51E is an addressable relay providing double pole volt free change over contacts rated to switch local mains supplies. The unit is intended for installation within the equipment to be switched thereby offering savings in installation costs when compared to long auxiliary circuit wiring runs out from the control panel. Complying with EN54 Part 18 the relay can be located anywhere on the two core ZP loop and is designed for power up or shut down of the mains electrical supply to ancillary equipment The unit is ideal for the control of associated system equipment such as mains fed magnetic door release circuits extract fans and dampers.The relay can be programmed to be activated by any single device groups of devices or all system devices. All types of system input signals can be arranged to operate the A51E which can include control panel indicators zonal outputs callpoints or sensors. Terminals 1-2 and 5-6 provide normally closed relay connections opening on alarm terminals 2-3 and 4-5 provide normally open relay connections closing on alarm. Housed in a low profile moulding the relay is designed to clip directly onto a standard DIN 35 mounting rail or equipment panel chassis. Alternatively the relay can be installed in a SMB-DIN100 box one unit capacity or SMB-DIN200 box two unit capacity - care should be taken to prohibit casual entry into the enclosure.A red LED indicator positioned on the front moulding flashes when the interface contacts have operated. For system test and commissioning the relay contacts can be operated manually enabling control circuits to be tested. Installed as part of an analogue addressable system up to 127 line devices sensors callpoints or interface units can be connected to each of the control panel loops. All loop devices incorporate switch settings enabling them to be assigned a unique address which is polled by the panel every two seconds.Key FeaturesAddressable mains rated unitComplies with EN54 Part 18Miniature sizeDIN 35 mounting rail fixingLoop wired - adjacent or internal to equipment to be switchedOperated from any combination of input addressesDouble pole volt free change over contacts

GBP 68.09
1

Ziton 2010-2-PAK-RMBN BacNet PAK

Ziton 2010-2-PAK-RMOH Contact ID PAK

Ziton FAW350 VAD Beacon Red Shallow Base Wall Mount Red Flash

Ziton FAW350 VAD Beacon Red Shallow Base Wall Mount Red Flash

Ziton FAW350 VAD Beacon Red Shallow Base Wall Mount Red FlashThe FAW350 is a general purpose wall mount LED beacon for fire alarm applications. It features a special base containing all wiring connections and allow for easy removalplacement of the device. With an EN54-23 approved coverage pattern of W-2.4-7.5 each FAW350 may be mounted up to 2.4m high and cover a square room of 7.5 x 7.5m with a single device.Easy and Fast InstallationThe FAx350 beacons allow faster installation and maintenance thanks to an innovative mounting base. Dispensing with the need for locking screws these beacons use TimeSaver bases from the 630 series detectors. Heads are simply locked onto the base with a twist and click action allowing fitting or removal at any time because the base is the only component that needs to be wired. As the cabling requirement is reduced commissioning time and costs are naturally reduced as well.Efficient and VersatileThe FAx350 beacons utilise a specially designed lens giving a uniformed light output over the specified coverage area. The flash rate of the beacon may be adjusted during installation with a selection of 0.5Hz or 1Hz.The mechanism for locking the device to the base may be activated if required. Once activated a special tool is required to remove the beacon from the base.Key FeaturesAutomatic syncronisationAnti-Tamper locking mechanismShallow mouting baseWiring directly to baseFlash rate selectable

GBP 61.79
1

Ziton AD88SS-0500 Alarmline 88 Degree Alarm Temperature Digital Sensor Cable PVC and Stainless Steel

Ziton AD88SS-0100 Alarmline 88 Degree Alarm Temperature Digital Sensor Cable PVC and Stainless Steel

Ziton AD105SS-0100 Alarmline 105 Degree Alarm Temperature Digital Sensor Cable PVC and Stainless Steel

Ziton AD105SS-0500 Alarmline 105 Degree Alarm Temperature Digital Sensor Cable PVC and Stainless Steel

Ziton FAC355 VAD Beacon Red Deep Base Ceiling Mounted Red Flash

Ziton FAC355 VAD Beacon Red Deep Base Ceiling Mounted Red Flash

Ziton FAC355 VAD Beacon Red Deep Base Ceiling Mounted Red FlashThe FAC350 is a general purpose ceiling mount LED beacon for fire alarm applications. It features a special base containing all wiring connections and allow for easy removalplacement of the device. With an EN54-23 approved coverage pattern of C-3-8.9 each FAC350 may be mounted up to 3m high and provide a 8.9m cylinder diameter coverage. A room size of 6.3 x 6.3m square room may therefore be covered with a single device.Easy and Fast InstallationThe FAx350 beacons allow faster installation and maintenance thanks to an innovative mounting base. Dispensing with the need for locking screws these beacons use TimeSaver bases from the 630 series detectors. Heads are simply locked onto the base with a twist and click action allowing fitting or removal at any time because the base is the only component that needs to be wired. As the cabling requirement is reduced commissioning time and costs are naturally reduced as well.Efficient and versatileThe FAx350 beacons utilise a specially designed lens giving a uniformed light output over the specified coverage area. The flash rate of the beacon may be adjusted during installation with a selection of 0.5Hz or 1Hz.The mechanism for locking the device to the base may be activated if required. Once activated a special tool is required to remove the beacon from the base.Key FeaturesAutomatic syncronisationAnti-Tamper locking mechanismShallow mouting baseWiring directly to baseFlash rate selectable

GBP 63.60
1

Ziton FAW355WC VAD Beacon White Deep Base Wall Mounted Clear Flash

Ziton FAW355WC VAD Beacon White Deep Base Wall Mounted Clear Flash

Ziton FAW355WC VAD Beacon White Deep Base Wall Mounted Clear FlashThe FAW355W is a general purpose wall mount LED beacon for fire alarm applications. It features a special deep base containing all wiring connections and allow for easy removalplacement of the device. With an EN54-23 approved coverage pattern of W-3.1-11.3 each FAW355WC may be mounted up to 3.5m high and cover a square room of 11.3 x 11.3m with a single device.Easy and Fast InstallationThe FAx350 beacons allow faster installation and maintenance thanks to an innovative mounting base. Dispensing with the need for locking screws these becons use a deep base version of the TimeSaver bases from the 630 series detectors. Heads are simply locked onto the base with a twist and click action allowing fitting or removal at any time because the base is the only component that needs to be wired. As the cabling requirement is reduced commissioning time and costs are naturally reduced as well.Efficient and VersatileThe FAx350 beacons utilise a specially designed lens giving a uniformed light output over the specified coverage area. The flash rate of the beacon may be adjusted during installation with a selection of 0.5Hz or 1Hz.The mechanism for locking the device to the base may be activated if required. Once activated a special tool is required to remove the beacon from the base.Please note Tool is required to remove the beacon from the base.Key FeaturesAutomatic syncronisationAnti-Tamper locking mechanismDeep mouting baseWiring directly to baseFlash rate selectableIP65 Ingress protection

GBP 60.58
1

Ziton ASW366 Sounder VAD Beacon Red Shallow Base Wall Mount Red Flash

Ziton ASW366 Sounder VAD Beacon Red Shallow Base Wall Mount Red Flash

Ziton ASW366 Sounder VAD Beacon Red Shallow Base Wall Mount Red FlashThe ASW366 is a RED general purpose wall mount electronic sounder and beacon for fire alarm applications. It features a special base containing all wiring connections allowing for easy placement or removal of the device. With an EN54-23 approved coverage pattern of W-2.4-7.5 for the beacon each ASW366 may be mounted up to 2.4m high and cover a square room of 7.5 x 7.5m with a single device.The ASx360 series sounders provide high sound output at a low current thus reducing power requirements and system cost. They are supplied with a volume control as standard allowing final audio adjustments to be made during installation. With a choice of 32 different tones see tones table in manual which are switch selectable the required tone can be selected during installation.The ASx360 series beacons utilise a specially designed lens giving a uniformed light output over the specified coverage area.The mechanism for locking the device to the base may be activated if required. Once activated a special tool is required to remove the sounder from the base.The ASx360 series alarm sounderbeacons allow faster installation and maintenance thanks to an innovative mounting base. Dispensing with the need for locking screws these devices use TimeSaver bases from the 630 series detector lines. Heads are simply locked onto the base with a twist and click action allowing fitting or removal at any time because the base is the only component that needs to be wired. As the cabling requirement is reduced commissioning time and costs are naturally reduced as well.Key FeaturesHigh sound output with Pulse Alert technology32 Tones user selectableAutomatic synchronisationVolume control and adjustable flash rateAnti-Tamper locking mechanismShallow mounting base with wiring to the baseSeparate sounder and beacon and controlEN543 and EN5423 approved CPR Certified

GBP 95.54
1

Ziton ASW367W Sounder VAD Beacon White Deep Base Wall Mount Red Flash

Ziton ASW367W Sounder VAD Beacon White Deep Base Wall Mount Red Flash

Ziton ASW367W Sounder VAD Beacon White Deep Base Wall Mount Red FlashThe ASW367W is a white general purpose wall mount electronic sounder and beacon for fire alarm applications. It features a special base containing all wiring connections allowing for easy placement or removal of the device. With an EN54-23 approved coverage pattern of W-2.4-7.5 for the beacon each ASW367W may be mounted up to 2.4m high and cover a square room of 7.5 x 7.5m with a single device.The ASx360 series sounders provide high sound output at a low current thus reducing power requirements and system cost. They are supplied with a volume control as standard allowing final audio adjustments to be made during installation. With a choice of 32 different tones see tones table in manual which are switch selectable the required tone can be selected during installation.The ASx360 series beacons utilise a specially designed lens giving a uniformed light output over the specified coverage area.The mechanism for locking the device to the base may be activated if required. Once activated a special tool is required to remove the sounder from the base.The ASx360 series alarm sounderbeacons allow faster installation and maintenance thanks to an innovative mounting base. Dispensing with the need for locking screws these devices use TimeSaver bases from the 630 series detector lines. Heads are simply locked onto the base with a twist and click action allowing fitting or removal at any time because the base is the only component that needs to be wired. As the cabling requirement is reduced commissioning time and costs are naturally reduced as well.Key FeaturesHigh sound output with Pulse Alert technology32 Tones user selectableAutomatic synchronisationVolume control and adjustable flash rateAnti-Tamper locking mechanismDeep mounting base with side cable entry and wiring to the baseWeather-proofSeparate sounder and beacon and controlEN543 and EN5423 approved CPR Certified

GBP 101.92
1

Ziton ASW366W Sounder VAD Beacon White Shallow Base Wall Mount Red Flash

Ziton ASW366W Sounder VAD Beacon White Shallow Base Wall Mount Red Flash

Ziton ASW366W Sounder VAD Beacon White Shallow Base Wall Mount Red FlashThe ASW366W is a white general purpose wall mount electronic sounder and beacon for fire alarm applications. It features a special base containing all wiring connections allowing for easy placement or removal of the device. With an EN54-23 approved coverage pattern of W-2.4-7.5 for the beacon each ASW366W may be mounted up to 2.4m high and cover a square room of 7.5 x 7.5m with a single device.The ASx360 series alarm sounderbeacons allow faster installation and maintenance thanks to an innovative mounting base. Dispensing with the need for locking screws these devices use TimeSaver bases from the 630 series detector lines. Heads are simply locked onto the base with a twist and click action allowing fitting or removal at any time because the base is the only component that needs to be wired. As the cabling requirement is reduced commissioning time and costs are naturally reduced as well.The ASx360 series sounders provide high sound output at a low current thus reducing power requirements and system cost. They are supplied with a volume control as standard allowing final audio adjustments to be made during installation. With a choice of 32 different tones see tones table in manual which are switch selectable the required tone can be selected during installation.The ASx360 series beacons utilise a specially designed lens giving a uniformed light output over the specified coverage area.The mechanism for locking the device to the base may be activated if required. Once activated a special tool is required to remove the sounder from the base.Key FeaturesHigh sound output with Pulse Alert technology32 Tones user selectableAutomatic synchronisationVolume control and adjustable flash rateAnti-Tamper locking mechanismShallow mounting base with wiring to the baseSeparate sounder and beacon and controlEN543 and EN5423 approved CPR Certified

GBP 95.54
1

Ziton ASW367 Sounder VAD Beacon Red Deep Base Wall Mount Red Flash

Ziton ASW367 Sounder VAD Beacon Red Deep Base Wall Mount Red Flash

Ziton ASW367 Sounder VAD Beacon Red Deep Base Wall Mount Red FlashThe ASW367 is a red general purpose wall mount electronic sounder and beacon for fire alarm applications. It features a special base containing all wiring connections allowing for easy placement or removal of the device. With an EN54-23 approved coverage pattern of W-2.4-7.5 for the beacon each ASW367 may be mounted up to 2.4m high and cover a square room of 7.5 x 7.5m with a single device.The ASx360 series sounders provide high sound output at a low current thus reducing power requirements and system cost. They are supplied with a volume control as standard allowing final audio adjustments to be made during installation. With a choice of 32 different tones see tones table in manual which are switch selectable the required tone can be selected during installation.The ASx360 series beacons utilise a specially designed lens giving a uniformed light output over the specified coverage area.The mechanism for locking the device to the base may be activated if required. Once activated a special tool is required to remove the sounder from the base.The ASx360 series alarm sounderbeacons allow faster installation and maintenance thanks to an innovative mounting base. Dispensing with the need for locking screws these devices use TimeSaver bases from the 630 series detector lines. Heads are simply locked onto the base with a twist and click action allowing fitting or removal at any time because the base is the only component that needs to be wired. As the cabling requirement is reduced commissioning time and costs are naturally reduced as well.Key FeaturesHigh sound output with Pulse Alert technology32 Tones user selectableAutomatic synchronisationVolume control and adjustable flash rateAnti-Tamper locking mechanismDeep mounting base with side cable entry and wiring to the baseWeather-proofSeparate sounder and beacon and controlEN543 and EN5423 approved CPR Certified

GBP 101.92
1