35 results (0,17349 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Hochiki EL-GRAPH FIREscape Graphics Software

Talentum UV Dual IR Flame Detector Head Unit 16591

Gent 805593.10 Wireless Detector Base

Talentum Dual IR Flame Detector 16581

Talentum 16579-00 Triple IR Intrinsically Safe Flame Detector Head Unit

Talentum Dual IR Hazardous Area Flameproof Detector 16511

International Gas Detectors TOC-635-PLUS Plus Gas Detection Control Panel

Klaxon TEA-0001 Inferno Internal Security Sounder

Kidde Airsense Air Heat Box 9-30422

Fireray 3000 Exd Explosion Proof Infrared Beam Smoke Detector 3000-115

Fireray 3000 Exd Explosion Proof Detector 3000-026

Talentum 16571-00 Dual IR Intrinsically Safe Detector

Advanced ADVLIVENW11-20 AdvancedLive Annual Connection - Networked Panels - 11-20 Panels

Advanced ADVLIVENW21-30 AdvancedLive Annual Connection - Networked Panels - 21-30 Panels

Advanced MXP-642 Commander BACnet Modbus IP Interface StandardBasic

Advanced MXP-642 Commander BACnet Modbus IP Interface StandardBasic

Advanced MXP-642 Commander BACnet Modbus IP Interface StandardBasicThe Advanced Commander is a powerful IP-based solution for customers requiring protocol translation between their Advanced Fire Control Equipment and a Building Management SystemBMS. The device can be used as a simple bridge between manufacturers components providing seamless integration and delivering guaranteed performance. The conversion protocols supported by the Advanced Commander are those generally found in use by the most common Building Management Systems on the market today and are currently BACNet or Modbus.The Advanced Commander supports up to 640 ObjectsTags of information which can be configured and passed between network components and delivered to the Building Managements Systems BMS using TCPIP technology. The Advanced Commander has powerful Windows- based software management suite built-in to provide engineers with the ability to write Cause Effect strategy check data logging calendar and timer functions. TCPIP connectivity permits the Advanced Commander to be located locally to the distributed network of Fire Control Panels but at the same time caters for remote programming and Building Management System BMS accessKey FeaturesBacNetModbus Protocol Integration640 Configurable ObjectTagsWindows-based ProgrammingPowerful IP ControllerConfigurable on a ZonePoint basis per Object for Fire Fault Alarm IsolationEngineer configurable over TCPIPSupports a single Ad-Net networkSmall CompactLow Voltage 12vDC - 24vDCPlease Note This unit requires MXP-510 BMS Interface.

GBP 2569.94
1

Advanced ADVLIVE1 AdvancedLive Annual Connection - 1 Panel

Aritech ATS1500A-IP-MM-HK KIT ATS1500A-IP-MM Including ATS1135 Keypad

Advanced ADVLIVENW2-10 AdvancedLive Annual Connection - Networked Panels - 2-10 Panels

Advanced ADVLIVENW30 AdvancedLive Annual Connection - Networked Panels - 30 Panels

Advanced MXP-642C Commander BACnet Modbus IP Interface Configured

Advanced MXP-642C Commander BACnet Modbus IP Interface Configured

Advanced MXP-642C Commander BACnet Modbus IP Interface ConfiguredThe Advanced Commander is a powerful IP-based solution for customers requiring protocol translation between their Advanced Fire Control Equipment and a Building Management SystemBMS. The device can be used as a simple bridge between manufacturers components providing seamless integration and delivering guaranteed performance. The conversion protocols supported by the Advanced Commander are those generally found in use by the most common Building Management Systems on the market today and are currently BACNet or Modbus.The Advanced Commander supports up to 640 ObjectsTags of information which can be configured and passed between network components and delivered to the Building Managements Systems BMS using TCPIP technology. The Advanced Commander has powerful Windows- based software management suite built-in to provide engineers with the ability to write Cause Effect strategy check data logging calendar and timer functions. TCPIP connectivity permits the Advanced Commander to be located locally to the distributed network of Fire Control Panels but at the same time caters for remote programming and Building Management System BMS accessKey FeaturesBacNetModbus Protocol Integration640 Configurable ObjectTagsWindows-based ProgrammingPowerful IP ControllerConfigurable on a ZonePoint basis per Object for Fire Fault Alarm IsolationEngineer configurable over TCPIPSupports a single Ad-Net networkSmall CompactLow Voltage 12vDC - 24vDCConfigurable using specialised Cause EffectPlease Note This unit requires MXP-510 BMS Interface.

GBP 3253.97
1

Protec Cirrus Pro 200 Aspiration Detector EN54-20 Approved

Protec Cirrus Pro 200 Aspiration Detector EN54-20 Approved

Protec Cirrus Pro 200 Aspiration Detector EN54-20 ApprovedCirrus Pro Series Aspirating Fire Detectors provide a solution for almost any aspirating system project from a simple single pipe detector with minimum Fire and Fault LED indications to a multiple pipe scanning detector with multifunction quarter VGA backlit LCD display. Programming for each detector is via a laptop computer or from an onboard or remotely mounted LCD display.The sensitivity range is the key feature that makes the Cirrus Pro Series Fire Detector the worlds most versatile fire detection device. For over 20 years Cloud Chamber detectors have been known as the most sensitive fire detection device able to detect at the true incipient stage of a developing fire. The New Cirrus Pro Series Detectors have a vast sensitivity range capable of being even more sensitive than previous versions. In addition the detector may now be configured to be installed in heavily contaminated environments such as polluted production and warehousing facilities.High Sensitivity Applications includeComputer Rooms Clean Rooms Control Rooms Data Centres Valve Halls Archive Storage Anechoic Chambers EDP areas.General Sensitivity Applications includeHistoric Buildings Museums Hospitals Cathedrals Theatres Art Galleries Clean Warehouses Atria Indoor Stadiums.Harsh Environment Applications includeCold Storage Facilities Specialist Production Facilities Food Industry Facilities Paper Production Facilities Transportation Terminals Flight Simulators Aircraft Hangers Prisons Inaccessible Voids Dirty Warehouses.Key FeaturesCloud Chamber Detection PrincipleUp to 200 mtrs Sampling PipeProgrammable Pre-Alarm warning condition3 Programmable Fire warning conditionsAirflow MonitoringFault Diagnostic featureImmune to dust humidity temperature changesEN54-20 ApprovedFor use with up to a total of 200mtrs of 25mm diameter sampling pipeFour sampling pipe inlet ports single sampling pipe exhaust portLED status indication of Common Fault Power Pre-alarm Fire 1 Fire 2 Fire 3 alarm conditionsInternal buzzer Silence button detector alarm Reset ButtonMay be networked with other Cirrus Pro Series aspirating detectors

GBP 3223.80
1

Solo 613 Urban Lightweight Backpack amp Poles Kit

Solo 613 Urban Lightweight Backpack amp Poles Kit

Solo 613 Urban Lightweight Backpack Poles KitA lightweight practical kit that provides the perfect balance of carrying test equipment for testing up to 4.5 meters alongside your other on-site essentials. A flexible backpack ideal for use on large sites or city working. Includes space for your essential test kit devices small tools accessories. Designed for allowing engineers to move easily around towns large sites or buildings without the need to carry bulk poles and bags.The kit includes a pole bag which comes complete with 1 x 110 1.75m telescopic 3 x 111 0.5m extension poles. The poles are designed to work in conjunction with each other and are used to test detectors up to a maximum working height of 4.5 metres. The pole bag is fastened onto the backpack using adjustable clips.Key FeaturesCustomisable main interior for test equipment battery batons accessoriesPadded compartment for Laptop or tabletLarge zipped pockets for cartridges smaller essentialsFront pocket for A4 notepad small tool sets etc.Clear pocket to promote your own brand or businessAdjustable quick-release clips for Solo 612 Pole bagWide shoulder straps and padded backChest strap for weight balanceLightweight design allows fast and efficient testingPoles are design from a pull-wound glass fibre constructionSimple locking mechanism on the polesUrban telescopic and extension poles are half the length of conventional polesCabin luggage compatible - Based on backpack dimensions. Please check with your individual airline as baggage allowances vary. Poles length 620mm may be allowed when held diagonallyKit Contains1 x Solo 611 Urban Lightweight Backpack1 x Solo 612 Urban Pole Bag1 x Solo 110 Urban 4-section Telescopic Pole 1.75m3 x Solo 111 Urban Extension Poles 0.5m

GBP 1398.04
1

Aritech FD2710R 2000 Series Addressable Reflective Beam Detector 100m

Aritech FD2710R 2000 Series Addressable Reflective Beam Detector 100m

Aritech FD2710R 2000 Series Addressable Reflective Beam Detector 100mThe FD2705R and FD2710R provides an integral loop powered analogue addressable reflective beam detector up to 100m distance. Wiring is restricted to a minimum as the transmitter and receiver are in the same housing. The detector is very easily aligned by means of checking the alignment LEDs. Easy alignment ensures optimum operation both electrically and mechanically. The unit is easily tested using the graduated obscuration test card supplied.The low power consumption of the units allows multiple beams to be powered on the same loop without compromising the systems autonomy. The FD2705R and FD2710R consist of an infrared transmitter and receiver in one single compact housing. The infrared signal is reflected by a prism and analysed for smoke presence. It is particularly designed to be use where point smoke detectors are not practical due to height or inaccessibility.The FD27xxR series units are loop powered for connection to 12002000 series fire panels. They use the Aritech 2000 series protocol. Various alarm thresholds may be selected from to suit the environment. If the signal reduces to below the selected threshold and is present for 10 seconds a fire condition is signalled. If the infrared beam is obscured rapidly to a level of 90 or greater for 10 seconds a fault condition is signalled. The detector monitors long term degradation of signal strength caused by component ageing or build-up of dirt on optical surfaces.Key FeaturesLoop Powered2000 series protocolArea coverage up to 600 mRange from 5 - 50 m and 50 - 100 mUp to ceiling heights of 25 mLow current consumption3 selectable alarm thresholdsSelf-check and automatic contamination compensationAutomatic discrimination between fire and faultVertical or horizontal mountEasy wiring and unique alignmentMicroprocessor controlledConforms to BS5839 part 5 and EN54

GBP 742.38
1

Aritech FD2705R 2000 Series Addressable Reflective Beam Detector 50m

Aritech FD2705R 2000 Series Addressable Reflective Beam Detector 50m

Aritech FD2705R 2000 Series Addressable Reflective Beam Detector 50mThe FD2705R and FD2710R provides an integral loop powered analogue addressable reflective beam detector up to 100m distance. Wiring is restricted to a minimum as the transmitter and receiver are in the same housing. The detector is very easily aligned by means of checking the alignment LEDs. Easy alignment ensures optimum operation both electrically and mechanically. The unit is easily tested using the graduated obscuration test card supplied.The low power consumption of the units allows multiple beams to be powered on the same loop without compromising the systems autonomy. The FD2705R and FD2710R consist of an infrared transmitter and receiver in one single compact housing. The infrared signal is reflected by a prism and analysed for smoke presence. It is particularly designed to be use where point smoke detectors are not practical due to height or inaccessibility.The FD27xxR series units are loop powered for connection to 12002000 series fire panels. They use the Aritech 2000 series protocol. Various alarm thresholds may be selected from to suit the environment. If the signal reduces to below the selected threshold and is present for 10 seconds a fire condition is signalled. If the infrared beam is obscured rapidly to a level of 90 or greater for 10 seconds a fault condition is signalled. The detector monitors long term degradation of signal strength caused by component ageing or build-up of dirt on optical surfaces.Key FeaturesLoop Powered2000 series protocolArea coverage up to 600 mRange from 5 - 50 m and 50 - 100 mUp to ceiling heights of 25 mLow current consumption3 selectable alarm thresholdsSelf-check and automatic contamination compensationAutomatic discrimination between fire and faultVertical or horizontal mountEasy wiring and unique alignmentMicroprocessor controlledConforms to BS5839 part 5 and EN54

GBP 581.88
1