161 results (0,14026 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Aritech VT705P Self Contained Internally Mounted Test Transmitter

Ziton SC008CO CO Fire Detector Test Spray

Gent S4-34741-50 Obscuration Test Card Set

Gent S4-34741-50 Obscuration Test Card Set

Gent S4-34741-50 Obscuration Test Card SetThe S4-34741-50 is an Obscuration Test Card Set designed for use with Gent Beam Detectors.Honeywell Gents S-Quad Beam Sensors provides an enhanced solution for linear beam detection for applications where point detection is either not practical or economic.Powered and controlled via the loop the beam is a market leading device with features such as one man alignment and commissioning which is achieved using the auto gain setting this ensure the optimum alignment is reached.Maintenance of the beam is enhanced with a key operated test feature which simulates the obscuration of the beam in a fire. The Gent loop powered beam is certified to EN54 parts 12 and 17.Key FeaturesS-Quad Beam pairs are loop powered supporting 16 pairs per loopEach beam can be set to one of 6 sensitivity states to provide a best fi t for individual applicationsThe beam provides increased resilience to interference from the sun and other light sourcesRemote key switch provides test facility at ground level without the need to gain access to beams mounted in high areasThe beam incorporates an LED array to indicate signal strength allowing accurate alignment during one person commissioningOptimum sensitivity is maintained by automatic gain setting triggered at the beam during alignmentThe optical lens design is intended to minimise build-up of dust to reduce the maintenance and cleaning requiredThe S-Quad beam is compatible with early versions of the Vigilon Beam using the S-Quad programming base avoiding the need to upgrade to latest control software

GBP 32.03
1

No Climb SoloC6-001 CO Test Aerosol Non-Flammable

Solo A10S Smoke Detector Test Gas Canister 250ml Non-Flammable

Solo A5 Smoke Detector Test Gas Canister 250ml Flammable

Solo A5 Smoke Detector Test Gas Canister 250ml Flammable

Solo A5 Smoke Detector Test Gas Canister 250ml FlammableThe new Solo A5 and Solo A10 have been designed to replace the Solo A3 and are suitable for testing all types of smoke detectors installed into buildings all around the world. Solo A5 is positioned very much as the every day tester. If a non-flammable solution is essential there is the Solo A10.The Solo A5 fits directly into the Solo 330332 but can also be used as a hand-held test gas canister. Test gas works by delivering smoke particles to the detector under test replicating the conditions of smoke from a fire in a safe and clean manner.Solo A5 and Solo A10 have been created to use different gasses to the Solo A3 this is because a gas within the A3 called HFC 134a has been identified in recent years by world governing bodies as harmful to the environment. Therefore as of the 31st December 2017 No Climb will no longer be able to manufacture Solo A3 stock already produced can still be used and a limited quantity can be bought from us while stock lasts.What No Climb products are affectedThe new regulations mean that Solo A3 Solo A7 Aero 300 Chekkit Smoke gas canisters will be phased out.When will they be phased outThe manufacturer No Climb will no longer be able to manufacture these products after 31st December 2017 however we do still have very limited stock of these products but once theyre all gone we will not be ordering any surplus stock up please Contact Us to find out more.Key FeaturesDetector manufacturer approvedDesigned for use with Solo 330332 dispenserCompliant with regulationsUL certified

GBP 20.28
1

Solo A10 Smoke Detector Test Gas Canister 150ml Non-Flammable

Solo A10 Smoke Detector Test Gas Canister 150ml Non-Flammable

Solo A10 Smoke Detector Test Gas Canister 150ml Non-FlammableThe new Solo A5 and Solo A10 have been designed to replace the Solo A3 and are suitable for testing all types of smoke detectors installed into buildings all around the world. Solo A10 is positioned very much as the every day tester. If a flammable solution is essential there is the Solo A5.The Solo A10 is available in a 150ml bottle and can be used as a hand-held test gas canister. Test gas works by delivering smoke particles to the detector under test replicating the conditions of smoke from a fire in a safe and clean manner.Solo A5 and Solo A10 have been created to use different gasses to the Solo A3 this is because a gas within the A3 called HFC 134a has been identified in recent years by world governing bodies as harmful to the environment. Therefore as of the 31st December 2017 No Climb will no longer be able to manufacture Solo A3 stock already produced can still be used and a limited quantity can be bought from us while stock lasts.What No Climb products are affectedThe new regulations mean that Solo A3 Solo A7 Aero 300 Chekkit Smoke gas canisters will be phased out.When will they be phased outThe manufacturer No Climb will no longer be able to manufacture these products after 31st December 2017 however we do still have very limited stock of these products but once theyre all gone we will not be ordering any surplus stock up please Contact Us to find out more.Will They be replacedTwo aerosols are being brought out Solo A5 and Solo A10 which can be used in the Solo 330 dispensers both products will offer a comparable performance to Solo A3. The Solo A10 offers a 150ml version which will be suitable for replacing the Aero 300 hand-held smoke gas canister alternatively the SmokeSabre will also be a relevant replacement. Unfortunately the Solo A7 detector air duster is not going to have a replacement.

GBP 22.20
1

Solo C3 CO Detector Test Gas Canister 250ml

Solo C3 CO Detector Test Gas Canister 250ml

Solo C3 CO Detector Test Gas Canister Designed for functional testing of detector testers the Solo C3 Aerosol ensures that detectors that respond to smoke are in full working order. Non-flammable this product is the professionals choice for value in aerosol smoke.Carbon Monoxide CO detectors operate by using an electrochemical cell which is able to detect CO in the atmosphere and is set at a predetermined threshold. The only way to correctly test a CO detector is to introduce CO safely to the sensor from the outside demonstrating free flow from the atmosphere to the sensor.The CO contained within the Solo C3 CO canister is at a level which poses no threat to the user when used correctly. Solo CO is formulated for use with the Solo 330 Dispenser. This prevents dissipation of the CO which would occur if used handheld.CO detectors are less common that smoke and heat detectors however when installed they still need to be tested. With all our products we pride ourselves on offering genuine choice and CO testing is no different.The need for carbon monoxide testers has increased in recent years thanks to widespread media coverage focusing on the danger of CO often referred to as the silent killer. More and more domestic properties including rentals now have carbon monoxide alarms installed and these too should be tested.Key FeaturesDetector manufacturer endorsedNon-flammable CO stimulusEnables controlled delivery over short burstsCompatible with Solo 330332 dispenserPlease note Due to the nature of the contents it is usual for this can to feel very light as stated on the back of the can.

GBP 22.50
1

Apollo Series 65 Optical Smoke Detector with Flashing LED and Magnetic Test Switch 55000-315APO

Apollo Series 65 Optical Smoke Detector with Flashing LED and Magnetic Test Switch 55000-315APO

Apollo Series 65 Optical Smoke Detector with Flashing LED and Magnetic Test Switch 55000-315APOThe Series 65 Optical Smoke Detector incorporates a pulsing LED located within the housing of the detector. The external detector moulding is identical to that of the ionisation detector and has an indicator LED which is clear in quiescent state but produces a red light in alarm.OperationThe Series 65 Optical Smoke Detector has a moulded self-extinguishing white polycarbonate case with wind resistant smoke inlets. Nickel-plated stainless-steel wiper contacts connect the detector to the base. Inside the case a printed circuit board has the optical system mounted on one side and the signal processing electronics on the other. The sensing chamber is a black moulding configured as a labyrinth which prevents penetration of ambient light. The labyrinth has a fine gauze insect-resistant cover. The chamber houses an infrared light emitting diode LED and a photo-diode which has an integral visible-light filter as extra protection against ambient light. Every three seconds the LED emits a burst of collimated light modulated at 4kHz. In clear air light from the LED does not fall directly on the diode because the LED is positioned at an obtuse angle to the diode. When smoke enters the chamber a fraction of the collimated light is scattered onto the photo-diode. If the resulting signal from the photo-diode is above a pre-set threshold the LED emits two more bursts of light this time at two-second intervals. If light is scattered onto the photo-diode by both these pulses due to the presence of smoke the detector signals an alarm state by switching the alarm latch on increasing the current drawn from the supply from about 40A to a maximum of 75mA. This fall in the impedance of the detector is recognised by the control panel as an alarm signal. The alarm current also illuminates the detector integral LED. A remote indicator connected between the L1 IN terminal and the R terminal will have a voltage equal to the supply voltage less 1 volt across it and so will illuminate. To ensure correct operation of the detector the control panel must be arranged to supply a maximum of 33 Volts dc and a minimum of 9 Volts dc in normal operation. The supply may fall to 6 Volts dc in alarm conditions if a supply current of at least 10mA is available at this voltage. To ensure effective illumination of the integral LED and any remote indicator the supply to the detector should exceed 12 Volts. To restore the detector to quiescent condition it is necessary to expel any smoke and interrupt the electrical supply to the detector for a minimum of one second.Key FeaturesResponds well to slow-burning smouldering firesWell-suited to bedrooms and escape routesUnaffected by wind or atmospheric pressureFlashing LED and magnet operated test switch option

GBP 19.98
1

Testifire XTR2 TESTIFIRE-MEM-001 Membrane

Testifire XTR2 TESTIFIRE-CPSU-001 Car PSU

Carrier DM3010R Intelligent Addressable Manual Call Point

Carrier DM3010R Intelligent Addressable Manual Call Point

Carrier DM3010R Intelligent Addressable Manual Call PointThe DM3000 Series is an intelligent range of addressable manual call points. The DM3010R is a red single action indoor MCPP with a House-on-Fire functional indicator. It is delivered complete with resettable element test connector and test key. Multiple optional accessories are available to facilitate most indoor installation requirements.AestheticsThis single action MCP is a standard profile indoor MCP suitable for surface and recess mount installations using standard or legacy European electrical boxes. With its designer dual tricolour LEDs it offers 180 clear local indication of its operational status even from a side view in a passage installation. The clean face of the MCP is further enhanced by a front access test key facility.Installation maintenance friendlyThe front facing access for an aesthetically matching test key allows unhindered access regardless of the installation location. The MCP key doubles as a test and disassembly tool allowing removal of the MCP front cover without the need for additional tools.CompatibilityThe DM3000 range may be used on compatible Aritech fire systems. They can in many cases be deployed into existing systems without CIE configuration changes.DetailsReliable single action manual call point for recess or surface mountingDual tri-colour status indicators offers 180 alarm visibilityTamper resistant design with resettable or frangible elementUnobtrusive front facing test facilityStandard mounting options facilitates easy retrofitting to existing installationsBack box with rear top and bottom cable entryScreen connection terminal in the back box for electrically noisy installationsPluggable connector with link through facility for ease of installation and pre-commissioning testingAn alarm flag on the face of the manual call point allows alarm indication even without alarm LEDsFast no-tools-required maintenance using the test keyUp to 128 devices supported per loop

GBP 41.57
1

Testifire XTR2 TESTIFIRE-USBC-001 USB-C to USB-C Cable

Kidde KE-DM3010RS27 Intelligent Addressable Manual Call Point - English - Red

Kidde KE-DM3010RS27 Intelligent Addressable Manual Call Point - English - Red

Kidde KE-DM3010RS27 Intelligent Addressable Manual Call Point - English - RedThe KE-DM3000 Series is an intelligent range of addressable Excellence Series manual call points. The KE-DM3010RS27 is a red single action indoor MCP with a House-on-Fire and FIRE functional indication. It is delivered complete with resettable element test connector and test key. Multiple optional accessories are available to facilitate most indoor installation requirements.AestheticsThis single action MCP is a standard profile indoor MCP suitable for surface and flush mount installations using standard or legacy European electrical boxes. With its designer dual tricolour LEDs it offers 180 clear local indication of its operational status even from a side view in a passage installation. The clean face of the MCP is further enhanced by a front access test key facility that allows access to the back box and cabling making additional fasting screw holes obsolete.Installation maintenance friendlyThe front facing access for an aesthetically matching test key allows unhindered access regardless of the installation location. The MCP key doubles as a test and disassembly tool allowing removal of the MCP front cover without the need for additional tools.CompatibilityThe KE-DM3000 range may be used on all Kidde Excellence Series fire systems and are also compatible with legacy Aritech fire systems. They can in many cases be deployed into existing systems without CIE configuration changes.

GBP 41.58
1

Kidde KE-DM3010OS99 3000 Series Intelligent Addressable Manual Call Point - Orange

Kidde KE-DM3010OS99 3000 Series Intelligent Addressable Manual Call Point - Orange

Kidde KE-DM3010OS99 3000 Series Intelligent Addressable Manual Call Point - OrangeThe KE-DM3000 Series is an intelligent range of addressable Excellence Series manual call points. The KE-DM3010OS99 is an orange single action indoor MCP with a SMOKE EXTRACTION functional indication. It is delivered complete with resettable element test connector and test key. Multiple optional accessories are available to facilitate most indoor installation requirements.AestheticsThis single action MCP is a standard profile indoor MCP suitable for surface and recess mount installations using standard or legacy European electrical boxes. With its designer dual tricolour LEDs it offers 180 clear local indication of its operational status even from a side view in a passage installation. The clean face of the MCP is further enhanced by a front access test key facility.CompatibilityThe KE-DM3000 range may be used on all Kidde Excellence Series fire systems and are also compatible with legacy Aritech fire systems. They can in many cases be deployed into existing systems without CIE configuration changes.Key FeaturesReliable single action manual call point for recess or surface mountingDual tri-colour status indicators offers 180 alarm visibilityTamper resistant design with resettable or frangible elementUnobtrusive front facing test facilityStandard mounting options facilitates easy retrofitting to existing installationsBack box with rear top and bottom cable entryScreen connection terminal in the back box for electrically noisy installationsPluggable connector with link through facility for ease of installation and pre-commissioning testingAn alarm flag on the face of the manual call point allows alarm indication even without alarm LEDsFast no-tools-required maintenance using the test keyUp to 128 devices supported per loop

GBP 38.77
1