2.071 results (0,15846 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Nitrogen Regulator and Hose NRH

Solo 330 Aerosol Smoke and CO Dispenser

Fireclass FC490ST Handheld Service and Programming Tool

Aico EI1020 Temperature and Humidity Environmental Sensor

Cooper MDP201 Duct Probe requires detector and base

Aico EI1025 Temperature Humidity and CO2 Environmental Sensor

Carrier VV600PS1 Seismic Detector For Safe And Vault ANPI

Carrier VV600PS1 Seismic Detector For Safe And Vault ANPI

Carrier VV600PS1 Seismic Detector For Safe And Vault ANPIThe VV600 Plus series seismic detectors are designed to detect attempts to break into vaults safes night deposit boxes automatic teller machines ATMs and other reinforced physical areas such as data storages and filing cabinets. These seismic detectors react to the characteristic vibration patterns of all breaking-and-entering tools such as hammers drills diamond saws hydraulic pressure tools and thermal tools like welding torch and thermal lance. They sense vibrations that occur within a 3-to-14-meter radius of where they are mounted depending on the material and design of the protected object.At the same time the seismic detectors allow for normal human activity around the protected area without the risk of creating unwanted alarms. To achieve this high level of accuracy each detector features three detectors in one. All three channels counting integration and explosion analyse the signal frequencies duration and amplitude in order to differentiate between random environmental disturbances and real intruder attack. The end result is detectors with excellent detection and false alarm immunity.The VV600 Plus series provides two different test functions automatic or manual activated. You can choose between internal test of the detector electronics or by using the test transmitter VT705P do a functional test of the detector and its physical contact to the protected object. A complete range of accessories is provided for all kinds of applications to achieve the highest security.Key FeaturesDetects all known methods of attacksAdvanced signal processing differentiates between ambient noise and real attacksExtremely low current drawTwo options of testingAdjustable sensitivityFull-scale tamper protectionComplete line of accessoriesEasy to install

GBP 189.83
1

Aritech CDC-2DWIF CDC 2 Door Controller With Wiegand Interface And 2 Relays And 4 Inputs PCB Only Accommodated By CDC4

Carrier FE371-N Magnetic Lock 5400N - MegaLED And Relay

Aritech DB995IVAS 990 Series Mounting Base w SounderVAD and Isolator

Aritech DB995IVAS 990 Series Mounting Base w SounderVAD and Isolator

Aritech DB995IVAS 990 Series Mounting Base with SounderVAD and IsolatorThe DB995IVAS is a loop-powered 990 series compatible sounderbeacon combined with a standard 900 series mounting base. It contains a built in short circuit isolator for overload protection. The DB995IVAS is used to signal a fire alarm in enclosed areas and may be used either with a detector fitted or with a cap for operation as a stand-alone alarm device.Sounder SupportThe DB995IVAS sounders support 15 tone pairs both evacuation and alert configurable at installation time. Seven volume settings allow the sounder to be set between 60 and 90 dBA tone dependant. Country specific regulatory tones are supported for Australia Germany New Zeeland Sweden The Netherlands and the UK.SynchronisationSynchronisation of audio-visual devices ensures the integrity of the signal and is supported on the DB995IVAS. Tones from different sounders do not merge into one signal that could be mistaken for a different tone. It is also possible to synchronise with the sound and visual outputs of any other sounders and beacons connected to the same fire panel loop.Self-TestThe beacon self-test is achieved by means of an LED monitoring circuit whilst the acoustic self-test means that the sounder listens to itself when it is switched on. If the LED fails during operation or no sound is detected within 5 seconds of the sounder being switched on a fault signal is transmitted to the control panel.Sounder VAD or BothUnder normal conditions the DB995IVAS turns on the sounder and VAD at the same time but it is also possible to control sounder to VAD separately from each other simply by controls from the fire CIE.Key Features15 Alarmevacuation and 15 alertwarning tonesSeven volume levelsCPR certified under EN543 EN5417 and EN5423 Open ClassIndividual addressing and controlIndependent control of sounder and VADSetup and test at point of installationUnique beacon and acoustic self-testNEN2575 and DIN0833 compliantBuilt-in isolator with status informationSynchronisation of VAD flash alert and evacuate tonesApollo equivalent 45681-393

GBP 191.38
1

Cygnus SN.FAP100.2 SmartNet Integrated MCP And Sounder Beacon IP67

Morley HON-CGW-MBB Fixed CLSS Gateway Ethernet and Wifi

Solo Spare 727 High Capacity Car Charger and 220 240v Mains

Gent S4-34741-01 34740 Angle Bracket and Base

STI STI-7523 Alarmed Enclosure with Backplate and Thumb Lock