785 results (0,14602 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Advanced CNLEDNM3AU Cine-LED Escape Sign Wall Mount Non-Addressable Non-Maintained Single Sided - EC Arrow Up

Advanced CNLEDNM3AL Cine-LED Escape Sign Wall Mount Non-Addressable Non-Maintained Single Sided - EC Arrow Left

Advanced CNLEDNM3AR Cine-LED Escape Sign Wall Mount Non-Addressable Non-Maintained Single Sided - EC Arrow Right

Advanced CNLEDNM3AD Cine-LED Escape Sign Wall Mount Non-Addressable Non-Maintained Single Sided - EC Arrow Down

Morley MI-DCZRM Non-Addressable Zone Monitor Module

Morley MI-DCZRM Non-Addressable Zone Monitor Module

Please note This product is now obsolete however we may still have some in stock. The replacement is theMorley MI-DCZRME Analogue Addressable Monitor Module.Morley MI-DCZRM Non-Addressable Zone Monitor ModuleThe MI-DCZRM addressable zone monitor module allows a zone of non-addressable devices to communicate with a Morley-IAS protocol analogue addressable system. As a result existing non-addressable zones can be integrated into a Morley-IAS protocol system. The module monitors a zone of two-wire non-addressable devices.Each MI-DCZRM uses one of 99 available module addresses on a loop. A fault signal will be transmitted to the panel in case of an open circuit or short circuit on the non-addressable zone wiring or when the external fault input is pulled low can be used for power supply monitoring. A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm subject to current limitations.Key FeaturesConnection of a zone of non-addressable detectors to an analogue addressable fire systemBuilt in isolation allowing system installation in stages without loss of protectionMonitors open circuit and short circuit faultsTRI-Colour Status LEDZone powered from addressable loop wiring or external 24V PSURemote reset of non-addressable zoneMonitoring of external power supplyExternal fault inputCPD approval to EN54-17 and EN54-18 LPCB and VdSDIN rail mountable consistent with all other modulesSupport for an extended power supply range as low as 18Vdc 60mA with an External PSU

GBP 82.21
1

Morley RSV-R25 Non Return Valve

Advanced LLED3NM3 SURCBK LED-Lite Downlighter Recessed Non-Addressable Non-Maintained Corridor

Advanced LLED3NM3 SURCBK LED-Lite Downlighter Recessed Non-Addressable Non-Maintained Corridor

Advanced LLED3NM3SURCBK LED-Lite Downlighter Recessed Non-Addressable Non-Maintained CorridorThe LED-Lite range of recessed luminaires offers a simple method of providing discrete emergency lighting in areas that require a self-contained solution. Available with a symmetrical wide-angle lens or an asymmetrical corridor lens for escape routes or a narrow 20 degree high level beam for highlighting points of emphasis the luminaire simply requires a permanent 230 Volt supply and addressable wiring to provide effective non-maintained emergency lighting with a 3-hour duration. It is available in a maintained version for such applications as night lighting in hospital wards. This version comes complete with a robust remote enclosure which houses all the control components. An alternative LED head is available that uses three 1W LEDs in a dichroic housing complete with a through hole flame-retardant pack to allow installation into solid ceilings such as plaster. The LED-Lite fully supports all features of the LuxIntelligent test system. IP65 weatherproof versions available for outside usage.OperationThe LED-Lite is supplied with integral non-maintained emergency lighting control gear. The self-contained unit offers 3-hour emergency lighting duration from integral nickel-metal hydride batteries. The LED-Lite incorporates a green LED to provide battery charge indication. The luminaires will automatically provide emergency lighting in the event of a loss of local mains supply. The benefits of modern LEDs are well documented.InstallationThe LED-Lite recessed units can be discretely mounted in a 45mm cut-out. When the corridor lens is specified the LED can easily be rotated to align the distribution along the escape route.

GBP 398.18
1

Advanced LLED3NM3 CWH LED-Lite Downlighter Recessed Non-Addressable Non-Maintained Corridor

Advanced LLED3NM3 CWH LED-Lite Downlighter Recessed Non-Addressable Non-Maintained Corridor

Advanced LLED3NM3CWH LED-Lite Downlighter Recessed Non-Addressable Non-Maintained CorridorThe LED-Lite range of recessed luminaires offers a simple method of providing discrete emergency lighting in areas that require a self-contained solution. Available with a symmetrical wide-angle lens or an asymmetrical corridor lens for escape routes or a narrow 20 degree high level beam for highlighting points of emphasis the luminaire simply requires a permanent 230 Volt supply and addressable wiring to provide effective non-maintained emergency lighting with a 3-hour duration. It is available in a maintained version for such applications as night lighting in hospital wards. This version comes complete with a robust remote enclosure which houses all the control components. An alternative LED head is available that uses three 1W LEDs in a dichroic housing complete with a through hole flame-retardant pack to allow installation into solid ceilings such as plaster. The LED-Lite fully supports all features of the LuxIntelligent test system. IP65 weatherproof versions available for outside usage.OperationThe LED-Lite is supplied with integral non-maintained emergency lighting control gear. The self-contained unit offers 3-hour emergency lighting duration from integral nickel-metal hydride batteries. The LED-Lite incorporates a green LED to provide battery charge indication. The luminaires will automatically provide emergency lighting in the event of a loss of local mains supply. The benefits of modern LEDs are well documented.InstallationThe LED-Lite recessed units can be discretely mounted in a 45mm cut-out. When the corridor lens is specified the LED can easily be rotated to align the distribution along the escape route.

GBP 321.95
1

Advanced LLED3NM3 CBLK LED-Lite Downlighter Recessed Non-Addressable Non-Maintained Corridor

Advanced LLED3NM3 CBLK LED-Lite Downlighter Recessed Non-Addressable Non-Maintained Corridor

Advanced LLED3NM3CBLK LED-Lite Downlighter Recessed Non-Addressable Non-Maintained CorridorThe LED-Lite range of recessed luminaires offers a simple method of providing discrete emergency lighting in areas that require a self-contained solution. Available with a symmetrical wide-angle lens or an asymmetrical corridor lens for escape routes or a narrow 20 degree high level beam for highlighting points of emphasis the luminaire simply requires a permanent 230 Volt supply and addressable wiring to provide effective non-maintained emergency lighting with a 3-hour duration. It is available in a maintained version for such applications as night lighting in hospital wards. This version comes complete with a robust remote enclosure which houses all the control components. An alternative LED head is available that uses three 1W LEDs in a dichroic housing complete with a through hole flame-retardant pack to allow installation into solid ceilings such as plaster. The LED-Lite fully supports all features of the LuxIntelligent test system. IP65 weatherproof versions available for outside usage.OperationThe LED-Lite is supplied with integral non-maintained emergency lighting control gear. The self-contained unit offers 3-hour emergency lighting duration from integral nickel-metal hydride batteries. The LED-Lite incorporates a green LED to provide battery charge indication. The luminaires will automatically provide emergency lighting in the event of a loss of local mains supply. The benefits of modern LEDs are well documented.InstallationThe LED-Lite recessed units can be discretely mounted in a 45mm cut-out. When the corridor lens is specified the LED can easily be rotated to align the distribution along the escape route.

GBP 321.95
1

Crowcon C01875 Calibration Flow Plate for Non-Pumped Tetra

Advanced NLS8NM3230 Cine-LiTe Fluorescent Escape Sign Wall Mount Non-Maintained Non-Addressable